DRYER INSTALLATION INSTRUCTIONS
29" and 27" Wide Models
Gas (U.S.A. and Canada) & Electric (Canada Only) INSTRUCTIONS D’INSTALLATION DE LA SÉCHEUSE Modèles de 29" et de 27" de largeur
À gaz (É.-U. et Canada) et Électrique (Canada uniquement)
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite: www.whirlpool.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta.
Table of Contents |
Table des matières |
DRYER SAFETY................................................................. |
2 |
INSTALLATION REQUIREMENTS.................................... |
4 |
Tools and Parts.................................................................... |
4 |
Location Requirements....................................................... |
5 |
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY......... |
7 |
Electrical Requirements...................................................... |
7 |
Install Leveling Legs............................................................ |
7 |
GAS DRYER POWER HOOKUP.................................................. |
8 |
Gas Supply Requirements................................................... |
8 |
Electrical Requirements...................................................... |
9 |
VENTING.................................................................................... |
10 |
Venting Requirements....................................................... |
10 |
Plan Vent System............................................................... |
11 |
Venting Kits........................................................................ |
11 |
Install Vent System............................................................ |
12 |
Make Gas Connection....................................................... |
13 |
Connect Vent...................................................................... |
13 |
LEVEL DRYER........................................................................... |
14 |
COMPLETE INSTALLATION CHECKLIST................................ |
14 |
REVERSE DOOR SWING (OPTIONAL)..................................... |
14 |
TROUBLESHOOTING................................................................ |
22 |
SÉCURITÉ DE LA SÉCHEUSE........................................ |
23 |
EXIGENCES D’INSTALLATION....................................... |
25 |
Outillage et pièces............................................................. |
25 |
Exigences d’emplacement................................................ |
26 |
RACCORDEMENT À L’ALIMENTATION ÉLECTRIQUE |
|
DE LA SÉCHEUSE ÉLECTRIQUE – CANADA SEULEMENT.... |
28 |
Spécifications électriques................................................. |
28 |
Installation des pieds de nivellement............................... |
29 |
RACCORDEMENT D’UNE SÉCHEUSE À GAZ........................ |
29 |
Spécifications de l’alimentation en gaz........................... |
29 |
Spécifications électriques................................................. |
31 |
L’ÉVACUATION.......................................................................... |
32 |
Exigences concernant l’évacuation................................. |
32 |
Planification du système d’évacuation............................ |
33 |
Trousses d’évacuation....................................................... |
33 |
Installation du circuit d’évacuation.................................. |
35 |
Raccordement au gaz....................................................... |
35 |
Raccordement du conduit d’évacuation......................... |
36 |
RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE......................... |
36 |
ACHEVER L’INSTALLATION – LISTE DE VÉRIFICATION....... |
37 |
INVERSION DU SENS DE L’OUVERTURE DE LA PORTE |
|
(FACULTATIF)............................................................................. |
37 |
DÉPANNAGE.............................................................................. |
47 |
INSTALLATION NOTES |
NOTES CONCERNANT L’INSTALLATION |
Date of purchase:_________________________________ |
Date d’achat :_____________________________________ |
Date of installation:_ _______________________________ |
Date d’installation :_ ________________________________ |
Installer:_________________________________________ |
Installateur :_______________________________________ |
Model number:____________________________________ |
Numéro de modèle :_________________________________ |
Serial number:____________________________________ |
Numéro de série :___________________________________ |
W10115228C |
1 |
|
W10115229C-SP |
||
|
DRYER SAFETY
2
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Adjustable wrench that |
Caulking gun and compound |
|
opens to 1" (25 mm) or |
(for installing new exhaust vent) |
|
hex-head socket wrench |
|
|
Flat-blade screwdriver |
#2 Phillips screwdriver |
Utility knife |
Putty knife |
Tools needed for gas installations:
1/4" nut driver or socket |
Tin snips (new vent |
wrench (recommended) |
installations) |
8" or 10" pipe wrench |
8" or 10" adjustable wrench |
|
(for gas connections) |
Tape measure |
Vent clamps |
Pipe-joint compound resistant to LP gas
Level |
Pliers |
4
Parts supplied:
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts are included.
Parts needed:
Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the “Assistance or Service” section of the Use and Care Guide.
Optional Equipment: (Not supplied with dryer)
Refer to your Use and Care Guide for information about accessories available for your dryer.
Location Requirements
You will need:
■■ A location allowing for proper exhaust installation. See “Venting Requirements.”
■■ A separate 30-amp circuit for electric dryers. ■■ A separate 15or 20-amp circuit for gas dryers.
■■ If you are using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”
■■ A sturdy floor to support dryer and a total weight (dryer and load) of 200 lbs. (90.7 kg). The combined weight of a companion appliance should also be considered.
■■ Level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.
5
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
29" Wide Models |
27" Wide Models |
|
Dryer Dimensions |
Dryer Dimensions |
|
|
|
23¾" |
|
|
(603 mm) |
|
43" |
43" |
|
(1092 mm) |
(1092 mm) |
13¾" (349 mm)
*29 |
1/2" |
|
*29 |
1/2" |
|
(749 mm) |
27" |
(749 mm) |
27" |
||
|
|
|
|
||
|
|
(687 mm) |
|
|
(687 mm) |
|
|
A |
|
|
B |
A. Large opening side-swing door
B. Wide opening hamper door
|
|
|
|
|
|
|
Installation Spacing |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3"* |
|
|
|
|
|
|
|
|
|
|
|
|
14"max.* |
48 in.2* |
(76 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
(356 mm) |
|
|
|
|
|
|
|
|
|
18"* |
|
|
|
|
(310 cm )2 |
|
|
|
|
|
|
|
|
|
(457 mm) |
|
|
|
|
|
|
|
|
|
A. Large opening side-swing door |
|
|
|
|
|
|
|
24 in2.* |
3"* |
|||
|
|
|
|
|
|
|
|
|
2 |
(76 mm) |
||||
|
|
B. Large opening side-swing door |
|
|
|
|
|
|
|
(155 cm ) |
||||
|
|
|
1" |
27" |
1" |
1"* |
29¼" |
5½"* |
|
|
||||
|
|
C. Wide opening side-swing door |
|
|
|
|||||||||
|
|
D. Wide opening hamper door |
|
(25 mm) |
(686 mm) |
(25 mm) (25mm) (743mm) (140mm) |
|
|||||||
Installation Spacing |
|
|
|
|
|
A |
|
|
B |
|
C |
|||
|
|
|
|
|
|
A. Recessed area |
|
|
||||||
|
|
|
|
|
|
3"* |
|
|
|
|
||||
|
|
|
|
|
|
|
|
B. Side view – closet or confined area |
||||||
|
|
|
|
14"max.* |
48 in.2* |
(76 mm) |
|
|
C. Closet door with vents |
|
||||
|
|
|
|
(356 mm) |
|
*Required spacing |
|
|
|
|
|
|
||
18"* |
|
|
|
2 |
|
|
|
|
|
|
|
|||
|
|
|
|
(310 cm ) |
|
|
|
|
|
|
|
|
|
|
(457 mm) |
|
|
|
|
|
|
Installation spacing for recessed area or closet |
|||||||
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
The dimensions shown are for the minimum spacing allowed. |
|||||||
|
|
|
|
|
24 in.2 * |
3"* |
■■ Additional spacing should be considered for ease of |
|||||||
|
|
|
|
|
(155 cm )2 |
(76 mm) |
installation and servicing. |
|
|
|
|
|||
1" |
29" |
1" |
1"* |
27¾" |
|
|
■■ Additional clearances might be required for wall, door, and |
|||||||
(25 mm) |
(737 mm) |
(25 mm) (25mm) (705 mm) |
|
|
floor moldings. |
|
|
|
|
|
|
|||
|
A |
|
|
B |
|
C |
■■ Additional spacing of 1" (25 mm) on all sides of the dryer is |
|||||||
|
|
A. Recessed area |
|
|
recommended to reduce noise transfer. |
|
||||||||
|
|
B. Side view – closet or confined area |
■■ For closet installation, with a door, minimum ventilation |
|||||||||||
|
|
C. Closet door with vents |
|
openings in the top and bottom of the door are required. |
||||||||||
*Required spacing |
|
|
|
|
|
|||||||||
|
|
|
|
|
Louvered doors with equivalent ventilation openings are |
|||||||||
|
|
|
|
|
|
|
acceptable. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
■■ Companion appliance spacing should also be considered. |
Mobile home – Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or the Canadian Manufactured Home Standard CAN/CSA-Z240 MH.
■■ Metal exhaust system hardware, available for purchase. For further information, please reference the “Assistance or Service” section of the Use and Care Guide.
■■ Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
6
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY
Electrical Requirements
It is your responsibility:
■■ To contact a qualified electrical installer.
■■ To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1 – latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
■■ To supply the required 4-wire, single-phase, 120/240 volt, 60 Hz., AC-only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
■■ This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.
4-wire receptacle (14-30R)
■■ Do not use an extension cord.
If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 8579325. For further information, please reference the “Assistance or Service” section of the Use and Care Guide.
GROUNDING INSTRUCTIONS
■ For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.
SAVE THESE INSTRUCTIONS
Install Leveling Legs
1. Prepare dryer for leveling legs
To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.
7
2. Screw in leveling legs
diamond marking
Examine leveling legs and find diamond marking. Screw legs into leg holes by hand. Use a wrench to finish turning legs until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is close to its final location. Leave enough room to connect the exhaust vent.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation Hold-down Kit. For ordering information please reference the Use and Care Guide.
GAS DRYER POWER
HOOKUP
Gas Supply Requirements
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is designcertified by CSA International for LP (propane or butane) gases with appropriate conversion.
■■ Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, please reference the “Assistance or Service” section of the Use and Care Guide.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the dryer from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier.
IMPORTANT: The gas installation must conform with local codes, or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
Gas supply line
■■ 1/2" NPT pipe is recommended.
■■ 3/8" approved tubing is acceptable for lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.
■■ Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).
■■ Must include a shut-off valve:
In the U.S.A.:
An individual manual shut-off valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shut-off valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shut-off valve be installed within six (6) feet (1.8 m) of the dryer.
The shut-off valve location should be easy to reach for opening and closing.
E
C
A
D
B
A.3/8" flexible gas connector
B.3/8" pipe to flare adapter fitting
C.1/8" NPT minimum plugged tapping
D.1/2" NPT gas supply line
E.Gas shut-off valve
Gas supply connection requirements
There are many methods by which your gas dryer can be connected to the gas supply. Listed here are some guidelines for two different methods of connection.
This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
8
Option 1 (Recommended Method)
Flexible stainless steel gas connector:
■■ If local codes permit, use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
■■ Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing (if codes and gas supplier permit).
■■ If you are using Natural Gas, do not use copper tubing.
■■ 3/8" flare x 3/8" NPT adapter fitting between dryer pipe and 3/8" approved tubing.
■■ Lengths over 20 ft. (6.1 m) should use larger tubing and a different size adapter fitting.
■■ If your dryer has been converted to use LP gas, 3/8" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.
Dryer gas pipe
■■ The gas pipe that comes out through the rear of your dryer has a 3/8" male pipe thread.
29" Wide Model
|
1¼" |
|
(32 mm) |
A |
9¼" |
|
(235 mm) |
A. 3/8" NPT dryer pipe |
|
27" Wide Model |
|
*5 3/4" |
A |
|
|
(159 mm) |
|
1 1/2"
(38 mm)
A. 3/8" NPT dryer pipe
Burner input requirements
Elevations up to 10,000 ft. (3,048 m):
■■ The design of this dryer is certified by CSA International for use at altitudes up to 10,000 ft. (3,048 m), above sea level at the B.T.U. rating indicated on the model/serial number plate. Burner input adjustments are not required when the dryer is operated up to this elevation.
Elevations above 10,000 ft. (3,048 m):
■■ When installed above 10,000 ft. (3,048 m) a 4% reduction of the burner B.T.U. rating shown on the model/serial number plate is required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
■■ The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than 1/2 psi.
Electrical Requirements
■■ 120 Volt, 60 Hz., AC only, 15or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
■ For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.
SAVE THESE INSTRUCTIONS
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
9
VENTING
Venting Requirements
Exhaust hoods:
■■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).
Recommended Styles:
WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.
4" (102 mm)
4" (102 mm) heavy metal exhaust vent
■■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.
■■ Do not use plastic or metal foil vent.
Rigid metal vent:
■■ Recommended for best drying performance and to avoid crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location.
■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.
■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should not exceed 73/4 ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review “Vent System Chart” and, if necessary, modify existing vent system to achieve best drying performance.
Louvered hood |
Box hood |
Acceptable Style:
Angled hood
Elbows:
■■ 45° elbows provide better airflow than 90° elbows.
Good Better
Clamps:
■■ Use clamps to seal all joints.
■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.
Improper venting can cause moisture and lint to collect indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
Housecleaning problems and health problems.
See “Venting Kits” for more information.
10
Plan Vent System
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
|
|
B |
|
|
C |
|
|
D |
|
|
E |
A |
|
F |
|
|
|
|
|
G |
|
|
B |
|
I |
H |
|
|
A. Dryer |
F. Rigid metal or flexible metal vent |
B. Elbow |
G.Vent length necessary to connect elbows |
C. Wall |
H. Exhaust outlet |
D. Exhaust hood |
I. Optional side exhaust outlet |
E. Clamps |
|
Optional exhaust installations:
27" Wide Models can be converted to exhaust out the right side, left side, or through the bottom (4-way vent kit). Each kit includes step-by-step instructions. For ordering information, see “Venting Kits.”
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate installations are available for purchase.
A B C
A.Standard rear offset exhaust installation
B.Leftor right-side exhaust installation (27" wide models only)
C.Bottom exhaust installation (27" wide models only)
Venting Kits
For more information, call 1-800-901-2042, or visit us at www.applianceaccessories.com. In Canada, call 1-800-807-6777 or visit us at www.whirlpoolparts.ca.
Part Number |
Description |
|
|
8171587RP |
0–5" Metal vent periscope |
|
|
4396037RP |
0"–18" Metal vent periscope |
|
|
4396011RP |
18"–29" Metal vent periscope |
|
|
4396014 |
29"–50" Metal vent periscope |
|
|
4392892 |
In-Wall metal DuraVent™ Periscope |
|
|
W10470674 |
4-way vent kit – universal grey (27" Dryers Only) |
|
|
4396028 |
Sure Connect™ venting kit |
|
(over-the-top installation) |
|
|
4396009RP |
5' Universal connect vent, flexible dryer venting |
|
|
4396010RP |
6' SecureConnect™ vent, flexible dryer venting |
|
|
4396013RB |
Dryer vent installer’s kit |
|
|
4396033RP |
5' flexible dryer venting with clamps |
|
|
4396727RP |
8' flexible dryer venting with clamps |
|
|
4396004 |
Dryer offset elbow |
|
|
4396005 |
Wall offset elbow |
|
|
4396006RW |
DuraSafe™ close elbow |
|
|
4396007RW |
Through-the-wall vent cap |
|
|
4396008RP |
4" steel dryer venting clamps – 2 pack |
|
|
8212662 |
Flush mounting louvered vent hood 4" |
11
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
The “Vent System Chart” provides venting requirements that will help achieve best drying performance.
Vent System Chart
|
Number of |
Type |
Box/louvered |
Angled |
|
|
90° turns or |
of vent |
hoods |
hoods |
|
|
elbows |
|
|
|
|
|
0 |
Rigid metal |
64 ft. (20 m) |
58 ft. (17.7 m) |
|
|
|
|
|
|
|
|
1 |
Rigid metal |
54 ft. (16.5 m) |
48 ft. (14.6 m) |
|
|
|
|
|
|
|
|
2 |
Rigid metal |
44 ft. (13.4 m) |
38 ft. (11.6 m) |
|
|
|
|
|
|
|
|
3 |
Rigid metal |
35 ft. (10.7 m) |
29 ft. (8.8 m) |
|
|
|
|
|
|
|
|
4 |
Rigid metal |
27 ft. (8.2 m) |
21 ft. (6.4 m) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Determine vent path:
■■ Select route that will provide straightest and most direct path outdoors.
■■ Plan installation to use fewest number of elbows and turns.
■■ When using elbows or making turns, allow as much room as possible.
■■ Bend vent gradually to avoid kinking. ■■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
■■ Use following “Vent System Chart” to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in “Vent System Chart.” Exhaust systems longer than those specified will:
■■ Shorten life of dryer.
■■ Reduce performance, resulting in longer drying times and increased energy usage.
NOTE: Side and bottom exhaust installations for 27" wide models have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Vent System Chart
(29" Wide Long Vent Models Only)
|
Number of |
Type |
Box/louvered, or |
|
|
|
90° turns |
of vent |
Angled hoods |
|
|
|
or elbows |
|
|
|
|
|
|
|
|
|
|
|
0 |
Rigid metal |
120 ft. (36.6 m) |
|
|
|
|
|
|
|
|
|
1 |
Rigid metal |
110 ft. (33.5 m) |
|
|
|
|
|
|
|
|
|
2 |
Rigid metal |
100 ft. (30.5 m) |
|
|
|
|
|
|
|
|
|
3 |
Rigid metal |
90 ft. (27.4 m) |
|
|
|
|
|
|
|
|
|
4 |
Rigid metal |
80 ft. (24.4 m) |
|
|
|
|
|
|
|
|
|
5 |
Rigid metal |
70 ft. (21.3 m) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Install Vent System
1. Install exhaust hood
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.
12
2. Connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.
Make Gas Connection
1. Connect gas supply to dryer
3. Open shut-off valve
Closed Avalve
OpenB valve
Open shut-off valve in supply line; valve is open when handle is parallel to gas pipe. Then, test all connections by brushing on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
Connect Vent
1. Connect vent to exhaust outlet
Flared |
Non-flared |
maleA fitting |
B |
male fitting |
Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint compound resistant to action of LP gas. Do not use TEFLON®† tape.
2. Plan pipe fitting connection
A
B
A.3/8" flexible gas connector
B.3/8" dryer pipe
D
C
C.3/8" to 3/8" pipe elbow
D.3/8" pipe-to-flare adapter fitting
A combination of pipe fittings must be used to connect dryer to existing gas line. A recommended connection is shown. Your connection may be different, according to supply line type, size, and location.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.
2. Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent. |
|
After dryer is in place, remove corner posts and cardboard |
13 |
from under the dryer. |
Level Dryer
1. Level dryer
Check levelness of dryer from side to side. Repeat from front to back.
NOTE: The dryer must be level for the moisture sensing system to operate correctly.
Not Level |
LEVEL |
Not Level |
2. Tighten and adjust leveling legs
If dryer is not level, prop up using a wood block. Use wrench to adjust legs up or down, and check again for levelness. Once legs are level, make sure all four legs are snug against the floor before tightening them.
Complete Installation Checklist
qCheck that all parts are now installed. If there is an extra part, go back through steps to see what was skipped.
qCheck that you have all of your tools.
qDispose of/recycle all packaging materials.
qCheck dryer’s final location. Be sure vent is not crushed or kinked.
qCheck that dryer is level. See “Level Dryer.”
qRemove film on console and any tape remaining on dryer.
qWipe dryer drum interior thoroughly with a damp cloth to remove any dust.
qRead “Dryer Use” in your Use and Care Guide.
q
If the dryer will not start, check the following:
■■ Dryer is plugged into a grounded 3-prong outlet. ■■ Electrical supply is connected.
■■ Household fuse is intact and tight, or circuit breaker has not tripped.
■■ Dryer door is closed.
qWhen the dryer has been running for 5 minutes, open
the dryer door and feel for heat. If you feel heat, cancel cycle and close the door.
If you do not feel heat, turn the dryer off and check to see whether gas supply line shut-off valve is open.
■■ If the gas supply line shut-off valve is closed, open it, then repeat the 5-minute test as outlined above.
■■ If the gas supply line shut-off valve is open, contact a qualified technician.
NOTE: You may notice an odor when the dryer is first heated. This odor is common when the heating element is first used. The odor will go away.
Reverse Door Swing (Optional)
If your door is the 29" Large Side-Swing Door, follow steps 1–6.
If your door is the 29" Super Wide Side-Swing Door, follow steps 1–13.
If your door is the 27" Wide Side-Swing Door, follow steps 1–11.
If your door is the 27" Wide Side-Swing Door with Glass, follow steps 1–14.
NOTE: Magnetized screwdriver is helpful.
14
29" Wide Model Large Side-Swing Door
1. Place towel on dryer
Place towel on top of dryer to avoid damaging the surface.
2. Remove bottom screws
Open dryer door. Remove bottom screws from dryer cabinet side of hinges. Loosen (do not remove) top screws from dryer cabinet side of hinges.
3. Lift door off top screws
Lift door until top screws in cabinet are in large part of hinge slot. Pull door forward off screws. Set door on top of dryer. Remove top screws from dryer cabinet.
4. Remove and transfer hinge hole plugs
Use a small, flat-blade screwdriver to gently remove 4 hinge hole plugs on left side of dryer cabinet. Insert plugs into hinge holes on opposite side of dryer cabinet.
5. Insert screws in hinge holes on dryer cabinet
NOTE: Two people may be needed to reinstall door.
Insert screws into bottom holes on left side of dryer cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges.
6. Check door strike alignment
Close door and check that door strike aligns with door catch. If needed, slide door catch left or right within slot to adjust alignment.
15