Roland SYSTEM-500 Complete Set Parameter Guide

The Parameters of the 521
The 521 is a module containing two VCF (Voltage Controlled Filter) blocks.
521
Copyright © 2015 ROLAND CORPORATION
SIG IN 1/2/3
These jacks input audio signals.
FREQ (Cuto frequency)
* At a setting of 10, the original waveform passes
through without change. As you lower the value, less of the high-frequency region passes through.
HPF (High pass lter)
Adjusts the cuto frequency of the HPF (High Pass Filter).
* At the OFF setting, the original waveform passes
through without change. As you raise the setting to 1 or 2, the cuto frequency rises, allowing only the high­frequency portion of the signal to pass through.
MOD IN KEY/2/3
These jacks input a voltage that controls the VCF color.
SIG IN level controls
These sliders adjust the level of the signals that are input from the SIG IN jacks.
RES (Resonance)
Boosts the frequency components in the region of the cuto frequency.
* By raising the resonance you can make the VCF
oscillate. You can use this as an audio source for sound eects, or use KYBD CV to control the VCF and play pitches from the keyboard.
OUT
These are output jacks. These jacks output the signal from the VCF.
Attenuator for CV input 2/ 3
These sliders adjust the gain of the voltage that is input from the MOD IN KEY/2/3 jacks.
01