Roland KS-G8B Owner’s Manual

Owner’s Manual
002a 003 004 007 013 014
other countries.
201a
Before using this stand, carefully read the sections entitled “USING THE UNIT SAFELY” and “IMPORTANT NOTES.” These sections provide important information concerning the proper operation of the stand. This owner’s manual should be saved and kept on hand as a convenient reference.
202
Copyright © 2013 ROLAND CORPORATION All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION.
Checking the Included Items
The following items are packed with the KS-G8B.
As soon as you open the package, check to make sure that all of these included items are present. If anything is missing, contact your dealer.
• KS-G8B (Stand body)
• Connecting bar x 4• Cable clip x 4• Drum key
Parts Descriptions
Support bar fastening screw
Support bar
Connecting bar
Memory lock
Support column fastening screw ‘B’
Support column fastening screw ‘A’
Arm
Assembly Procedure
First, lay the packing material on the  oor and place the stand on it as shown in the following illustration.
* Place the rubber feet
downward.
Adjusting the Height
You can adjust the height of the KS-G8B in three levels: height 1 (645 mm), height 2 (730 mm), and height 3 (815 mm).
* When the stand is shipped, it is adjusted to height 1 (645 mm). If
you don’t need to change the height, proceed to “Provisionally
Assembling the Leg and Arm”.
1. Use the drum key to remove the two height adjustment screws.
Height adjustment screws
Provisionally Assembling the Leg and Arm
To prevent the screw holes from becoming misaligned, only tighten the screws  nger-tight; don’t tighten them completely.
1. Use the drum key to remove the support column fastening
screw ‘A’.
Drum key
Support column fastening screw ‘A’
2. Raise the support column, and hold it in place with your hand.
3. Insert the previously-removed column fastening screws ‘A’
into their original location, and  nger-tighten the screws to provisionally fasten the support column.
Adjusting the Support Bars
1. Use the drum key to remove the support bar fastening screws
located at the end of the left and right support bars.
NOTE
The support bar fastening screws will be used when assembling the support bars. Take care not to lose them.
Support bar fastening screw
2. If you will be using the stand at height 2 (730 mm), attach one
Connecting bar to each side, left and right. If you will be using the stand at height 3 (815 mm), attach two Connecting bars to each side, left and right.
* If you have not adjusted the height in “Adjusting the Height,” proceed to
“Provisionally Assembling the Support Bars and Memory Locks”.
Provisionally Assembling the Support Bars
Support column
Adjuster
Cable clip
Leg
Rubber feet
Before Assembling
• Be careful not to pinch your  ngers when setting up the stand.
• Do not adjust the height of the stand while the keyboard is resting on it.
• Do not put your  ngers into the pipes of the stand. Doing so may cause injury.
• Firmly tighten screws before using the stand. In particular, check that everything is secure before a performance. If any parts are loose, your keyboard may fall down, causing injury.
• Place your keyboard so that it is centered on the middle of the stand.
• Use the included cable clip to secure any cables connected to your keyboard.
• Do not move the stand with the keyboard resting on it. Doing so may cause the keyboard to overturn or fall.
Main Speci cations
Weight Capacity Maximum 70 kg, 154 lbs 6 oz
1,210 (W) x 710 (D) x 645–815 (H) mm 47-11/16 (W) x 28 (D) x 25-7/16–32-1/8 (H) inches
1,210 (W) x 730–920 (D) x 125 (H) mm 47-11/16 (W) x 28-3/4–36-1/4 (D) x 4-15/16 (H) inches
9.7 kg 21 lbs 7 oz
975 (W) x 265 (D) mm 38-7/16 (W) x 10-7/16 (D) inches
Dimensions
Weight
Minimum Keyboard Size for Installation
962a
*
In the interest of product improvement, the speci cations and/or appearance of this unit are subject to change without prior notice.
Unfolded
Folded
2. Adjust the support column by sliding it to the desired height.
Setting Height Remarks
Position where two holes are visible
Align the holes accurately
Height 2 730 mm
Position where four holes are visible
Align the holes accurately
Height 3 815 mm
3. Verify that the holes are aligned, and then use the drum key
to securely fasten the two height adjustment screws that you removed.
HINT
While fastening the height adjustment screws, gently lift up the support column that you slid; this will let you tighten the screws smoothly.
MEMO
If the support column is raised insu ciently or too high, you won’t be able to tighten the screws smoothly.
Make  ne adjustments to the angle of the support column to  nd the point at which the screws can be tightened smoothly.
4. Use the drum key to remove the support column fastening
screw ‘B’.
Support column
fastening screw ‘B’
Drum key
5. Use one hand to hold the tip of the arm, and rotate it so that the
arm is horizontal.
6. Use the other hand to hold support column screw ‘B’, and insert
it at a right angle to the support column. Finger-tighten the screw to provisionally fasten the arm.
MEMO
If you are unable to smoothly tighten the screw, make  ne adjustments to the angle of the arm to  nd the point at which you can tighten the screw smoothly.
and Memory Locks
1. Use the drum key to loosen the
memory locks.
Memory lock
2. Raise each support bar.
3. While lightly pressing the arm upward, insert the support bar
into the hole located at the end of the arm.
Insert support bar into the hole near the end of arm.
4. Finger-tighten the support bar fastening screw to provisionally
fasten the support bar.
MEMO
If you are unable to smoothly tighten the screw, move the support column slightly forward or backward to  nd the point at which the screw can be tightened smoothly.
5. Change the position of the memory lock as appropriate for the
height of the support column.
Height 1 Height 2 Height 3
Securely Tightening the Screws
1. Use the drum key to securely tighten the screws in the order
shown in the illustration below.
1
3
4
2
2. Gently rock the KS-G8B to see whether there is any instability.
If there is any instability, turn the adjusters to stabilize the stand.
Adjuster
This completes assembly of the KS-G8B.
If you want to change the height of the stand
1. Loosen support column fastening screw ‘A’, support
column fastening screw ‘B’, and the memory locks.
2. Remove the left and right support bar fastening screws.
3. While grasping the support bar, detach the support
bars from the arm and fold them down as shown in the illustration below.
4. In order to change the height safely, lay down the stand as
shown in the illustration.
5. Adjust the height of the support column as described in
“Adjusting the Height”.
6. Using both hands to hold the support column, slowly raise
the stand upright.
7. Adjust the length of the support bars as described in
“Adjusting the Support Bars”.
8. Provisionally fasten the support bars and the memory
locks as described in “Provisionally Assembling the Support Bars and Memory Locks”.
9. Firmly tighten the screws as described in “Securely
Tightening the Screws”.
10. Gently rock the KS-G8B to see whether there is any
instability.
USING THE UNIT SAFELY
About WARNING and CAUTION Notices
Used for instructions intended to alert the user to the risk of death or severe injury should the unit be used improperly.
Used for instructions intended to alert the user to the risk of injury or material damage should the unit be used improperly.
* Material damage refers to damage or
other adverse effects caused with respect to the home and all its furnishings, as well to domestic animals or pets.
ALWAYS OBSERVE THE FOLLOWING
WARNING CAUTION
Do not disassemble or modify by yourself
Do not carry out anything unless you are instructed to do so in the owner’s manual. Otherwise, you risk causing malfunction.
Do not repair or replace parts by yourself
Refer all servicing to your retailer, the nearest Roland Service Center, or an authorized Roland distributor, as listed on the “Information.”
Do not use or store in the following types of locations
• Subject to temperature extremes (e.g., direct sunlight in an enclosed vehicle, near a heating duct, on top of heat­generating equipment); or are
• Damp (e.g., baths, washrooms, on wet  oors); or are
• Exposed to steam or smoke; or are
• Subject to salt exposure; or are
• Exposed to rain; or are
• Dusty or sandy; or are
• Subject to high levels of vibration and shakiness.
Do not place in an unstable location
Otherwise, you risk injury as the result of the stand toppling over or dropping down.
Be cautious to protect children from injury
Always make sure that an adult is on hand to provide supervision and guidance when using the stand in places where children are present, or when a child will be using the stand.
Do not drop or subjec t to strong impact
Otherwise, you risk causing damage or malfunction.
About the Symbols
The symbol alerts the user to important instructions or warnings.The specific meaning of the symbol is determined by the design contained within the triangle. In the case of the symbol at left, it is used for general cautions, warnings, or alerts to danger.
The symbol alerts the user to items that must never be carried out (are forbidden). The specific thing that must not be done is indicated by the design contained within the circle. In the case of the symbol at left, it means that the unit must never be disassembled.
The symbol alerts the user to things that must be carried out. The specific thing that must be done is indicated by the design contained within the circle. In the case of the symbol at left, it means that the power-cord plug must be unplugged from the outlet.
101e 101f 106 118d
Use only stand manufactured by Roland
This stand for use only with speci c Roland musical instruments. See apparatus instructions. Use with other models is capable of resulting in instability causing possible injury.
Evaluate safety issues before using stands
Even if you observe the cautions given in the owner’s manual, certain types of handling may allow keyboard to fall from the stand, or cause the stand to overturn. Please be mindful of any safety issues before using this product.
Avoid climbing on top of the unit, or placing heavy objects on it
Otherwise, you risk injury as the result of the unit toppling over or dropping down.
Keep small items out of the reach of children
To prevent accidental ingestion of the parts listed below, always keep them out of the reach of small children.
• Removable Parts Screws
IMPORTANT NOTES
Placement
360 401a 402
• Depending on the material and temperature of the surface on which you place the stand, its rubber feet may discolor or mar the surface.
Maintenance
• For everyday cleaning wipe the stand with a soft, dry cloth or one that has been slightly dampened with water. To remove stubborn dirt, use a cloth impregnated with a mild, non-abrasive detergent. Afterwards, be sure to wipe the stand thoroughly with a soft, dry cloth.
• Never use benzine, thinners, alcohol or solvents of any kind, to avoid the possibility of discoloration and/or deformation.
Trademarks
• Roland is a registered trademark of Roland Corporation in the United States and/or
Information
AFRICA
REUNION
MARCEL FO-YAM Sarl
25 Rue Jules Hermann, Chaudron - BP79 97 491 Ste Clotilde Cedex, REUNION ISLAND TEL: (0262) 218-429
SOUTH AFRICA
Paul Bothner(PTY)Ltd.
Royal Cape Park, Unit 24 Londonderry Road, Ottery 7800 Cape Town, SOUTH AFRICA TEL: (021) 799 4900
ASIA
CHINA
Roland Shanghai Electronics Co.,Ltd.
5F. No.1500 Pingliang Road, Yangpu Shanghai 200090, CHINA TEL: (021) 5580-0800
Roland Shanghai Electronics Co.,Ltd. (BEIJING OFFICE)
3F, Soluxe Fortune Building 63 West Dawang Road, Chaoyang Beijing, CHINA TEL: (010) 5960-2565/0777
HONG KONG
Tom Lee Music
11/F Silvercord Tower 1 30 Canton Rd Tsimshatsui, Kowloon, HONG KONG TEL: 852-2737-7688
Parsons Music Ltd.
8th Floor, Railway Plaza, 39 Chatham Road South, T.S.T, Kowloon, HONG KONG TEL: 852-2333-1863
INDIA
Rivera Digitec (India) Pvt. Ltd.
411, Nirman Kendra Mahalaxmi Flats Compound O . Dr. Edwin Moses Road, Mumbai-400011, INDIA TEL: (022) 2493 9051
INDONESIA
PT. Citra Intirama
Ruko Garden Shopping Arcade Unit 8 CR, Podomoro City Jl.Letjend. S.Parman Kav.28 Jakarta Barat 11470, INDONESIA TEL: (021) 5698-5519/5520
KAZAKHSTAN
Alatau Dybystary
141 Abylai-Khan ave, 1st  oor, 050000 Almaty, KAZAKHSTAN TEL: (727) 2725477 FAX: (727) 2720730
KOREA
Cosmos Corporation
1461-9, Seocho-Dong, Seocho Gu, Seoul, KOREA TEL: (02) 3486-8855
MALAYSIA/SINGAPORE
Roland Asia Paci c Sdn. Bhd.
45-1, Block C2, Jalan PJU 1/39, Dataran Prima, 47301 Petaling Jaya, Selangor, MALAYSIA TEL: (03) 7805-3263
PHILIPPINES
G.A. Yupangco & Co. Inc.
339 Gil J. Puyat Avenue Makati, Metro Manila 1200, PHILIPPINES TEL: (02) 899 9801
TAIWAN
ROLAND TAIWAN ENTERPRISE CO., LTD.
9F-5, No. 112 Chung Shan North Road Sec. 2 Taipei 104, TAIWAN R.O.C. TEL: (02) 2561 3339
This product contains chemicals known to cause cancer, birth defects and other reproductive harm, including lead.
When you need repair service, call your nearest Roland Service Center or authorized Roland distributor in your country as shown below.
THAILAND
Theera Music Co. , Ltd.
100-108 Soi Verng Nakornkasem, New Road, Sumpantawong, Bangkok 10100, THAILAND TEL: (02) 224-8821
VIET NAM
VIET THUONG CORPORATION
386 CACH MANG THANG TAM ST. DIST.3, HO CHI MINH CITY, VIET NAM TEL: (08) 9316540
OCEANIA
AUSTRALIA/ NEW ZEALAND
Roland Corporation Australia Pty.,Ltd.
38 Campbell Avenue, Dee Why West. NSW 2099, AUSTRALIA
For Australia TEL: (02) 9982 8266
For New Zealand TEL: (09) 3098 715
CENTRAL/LATIN
AMERICA
ARGENTINA
Instrumentos Musicales S.A.
Av.Santa Fe 2055 (1123) Buenos Aires, ARGENTINA TEL: (011) 4508-2700
BARBADOS
A&B Music Supplies LTD
12 Webster Industrial Park Wildey, St.Michael, BARBADOS TEL: (246) 430-1100
BRAZIL
Roland Brasil Ltda.
Rua San Jose, 211 Parque Industrial San Jose Cotia - Sao Paulo - SP, BRAZIL TEL: (011) 4615 5666
CHILE
Comercial Fancy II S.A.
Rut.: 96.919.420-1 Nataniel Cox #739, 4th Floor Santiago - Centro, CHILE TEL: (02) 384-2180
COLOMBIA
CENTRO MUSICAL S.A.S.
Parque Industrial del Norte Bodega 130 GIRARDOTA - ANTIOQUIA, COLOMBIA TEL: (454) 57 77 EXT 115
COSTA RICA
JUAN Bansbach Instrumentos Musicales
Ave.1. Calle 11, Apartado 10237, San Jose, COSTA RICA TEL: 258-0211
CURACAO
Zeelandia Music Center Inc.
Orionweg 30 Curacao, Netherland Antilles TEL: (305) 5926866
DOMINICAN REPUBLIC
Instrumentos Fernando Giraldez
Calle Roberto Pastoriza #325 Sanchez Naco Santo Domingo, DOMINICAN REPUBLIC TEL: (809) 683 0305
ECUADOR
Mas Musika
Rumichaca 822 y Zaruma Guayaquil - ECUADOR TEL: (593-4) 2302364
EL SALVADOR
OMNI MUSIC
75 Avenida Norte y Final Alameda Juan Pablo II, Edi cio No.4010 San Salvador, EL SALVADOR TEL: 262-0788
GUATEMALA
Casa Instrumental
Calzada Roosevelt 34-01,zona 11 Ciudad de Guatemala, GUATEMALA TEL: (502) 599-2888
HONDURAS
Almacen Pajaro Azul S.A. de C.V.
BO.Paz Barahona 3 Ave.11 Calle S.O San Pedro Sula, HONDURAS TEL: (504) 553-2029
MARTINIQUE
Musique & Son
Z.I.Les Mangle 97232 Le Lamentin, MARTINIQUE F.W.I. TEL: 596 596 426860
MEXICO
Casa Veerkamp, s.a. de c.v.
Av. Toluca No. 323, Col. Olivar de los Padres 01780 Mexico D.F., MEXICO TEL: (55) 5668-6699
Faly Music
Sucursal Capu Blvd. Norte N.3213 Col. Nueva Aurora Cp.72070 Puebla, Puebla, MEXICO TEL: 01 (222) 2315567 o 97 FAX: 01 (222) 2266241
Gama Music S.A. de C.V.
Madero Pte. 810 Colonia Centro C.P. 64000 Monterrey, Nuevo León, MEXICO TEL: 01 (81) 8374-1640 o 8372-4097 www.gamamusic.com
Proscenia
Morelos No. 2273 Col. Arcos Sur C.P. 44120 Guadalajara, Jalisco, MEXICO TEL: 01(33) 3630-0015
NICARAGUA
Bansbach Instrumentos Musicales Nicaragua
Altamira D'Este Calle Principal de la Farmacia 5ta.Avenida 1 Cuadra al Lago.#503 Managua, NICARAGUA TEL: (505) 277-2557
PANAMA
SUPRO MUNDIAL, S.A.
Boulevard Andrews, Albrook, Panama City, REP. DE PANAMA TEL: 315-0101
PARAGUAY
WORLD MUSIC
Jebai Center 2018, Centro CIUDAD DE ESTE, PARAGUAY TEL: (595) 615 059
PERU
AUDIONET DISTRIBUCIONES MUSICALES SAC
Jr. Ramon Dagnino N°201- Jesús María DISTRITO DE JESUS MARIA LIMA, PERU TEL: 9 983 47 301 - 51 433 80 83
TRINIDAD
AMR Ltd
Ground Floor Maritime Plaza Barataria TRINIDAD W.I. TEL: (868) 638 6385
URUGUAY
Todo Musica S.A.
Francisco Acuna de Figueroa 1771 C.P.: 11.800 Montevideo, URUGUAY TEL: (02) 924-2335
VENEZUELA
Instrumentos Musicales Allegro,C.A.
Av.las industrias edf.Guitar
#7 zona Industrial de
import Turumo Caracas, VENEZUELA TEL: (212) 244-1122
EUROPE
BELGIUM/FRANCE/ HOLLAND/ LUXEMBOURG
Roland Central Europe N.V.
Houtstraat 3, B-2260, Oevel (Westerlo) BELGIUM TEL: (014) 575811
BOSNIA AND HERZEGOVINA
Mix-AP Music
78000 Banja Luka, Veselina Maslese 3, BOSNIA AND HERZEGOVINA TEL: 65 403 168
CROATIA
ART-CENTAR
Degenova 3. HR - 10000 Zagreb, CROATIA TEL: (1) 466 8493
CZECH REP.
CZECH REPUBLIC DISTRIBUTOR s.r.o
Pod Bání 8 180 00 Praha 8, CZECH REP. TEL: 266 312 557
DENMARK/ESTONIA/ LATVIA/LITHUANIA
Roland Scandinavia A/S
Skagerrakvej 7 Postbox 880 DK-2100 Copenhagen, DENMARK TEL: 39166222
FINLAND
Roland Scandinavia As, Filial Finland
Vanha Nurmijarventie 62 01670 Vantaa, FINLAND TEL: (0) 9 68 24 020
GERMANY/AUSTRIA
ROLAND Germany GmbH.
Adam-Opel-Strasse 4, 64569 Nauheim, GERMANY TEL: 6152 95546-00
GREECE/CYPRUS
STOLLAS S.A. Music Sound Light
155, New National Road Patras 26442, GREECE TEL: 2610 435400
HUNGARY
Roland East Europe Ltd.
2045. Törökbálint, FSD Park 3. ép., Budapest, HUNGARY TEL: (23) 511 011
IRELAND
Roland Ireland
E2 Calmount Park, Calmount Avenue, Dublin 12, Republic of IRELAND TEL: (01) 4294444
ITALY
Roland Italy S. p. A.
Viale delle Industrie 8, 20020 Arese, Milano, ITALY TEL: (02) 937-78300
MACEDONIA
MK MJUZIK
Alekso Demnievski-Bauman 9-3, 1400 Veles, MACEDONIA TEL: 70 264 458
MONTENEGRO
MAX-AP
Przno, Kamenovo bb., 86000 Budva, MONTENEGRO TEL: 68 050 112
NORWAY
Roland Scandinavia Avd. Kontor Norge
Lilleakerveien 2 Postboks 95 Lilleaker N-0216 Oslo, NORWAY TEL: 2273 0074
POLAND
ROLAND POLSKA SP. Z O.O.
ul. Kty Grodziskie 16B 03-289 Warszawa, POLAND TEL: (022) 678 9512
PORTUGAL
Roland Systems Group EMEA, S.L. Branch O ce Porto
Edifício Tower Plaza Rotunda Eng. Edgar Cardoso 23, 4-B 4400-676 Vila Nova de Gaia, PORTUGAL TEL: (+351) 22 608 00 60
ROMANIA
Pro Music Concept SRL
440221 Satu Mare B-dul Independentei nr. 14/a., ROMANIA TEL: (0361) 807-333
RUSSIA
Roland Music LLC
Dorozhnaya ul.3,korp.6 117 545 Moscow, RUSSIA TEL: (495) 981-4967
SERBIA
Music AP
Sutjeska br. 5 XS - 24413 PALIC, SERBIA TEL: (0) 24 539 395
SLOVAKIA
DAN Acoustic s.r.o.
Povazská 18. SK - 940 01 Nové Zámky, SLOVAKIA TEL: (035) 6424 330
SPAIN
Roland Systems Group EMEA, S.L.
Paseo García Faria, 33-35 08005 Barcelona, SPAIN TEL: 93 493 91 00
SWEDEN
Roland Scandinavia A/S SWEDISH SALES OFFICE
Mårbackagatan 31, 4 tr. SE-123 43 Farsta, SWEDEN TEL: (0) 8 683 04 30
SWITZERLAND
Roland (Switzerland) AG
Landstrasse 5, Postfach, CH-4452 Itingen, SWITZERLAND TEL: (061) 975-9987
TURKEY
ZUHAL DIS TICARET A.S.
Galip Dede Cad. No.33 Beyoglu, Istanbul, TURKEY TEL: (0212) 249 85 10
UKRAINE
EURHYTHMICS Ltd.
P.O.Box: 37-a. Nedecey Str. 30 UA - 89600 Mukachevo, UKRAINE TEL: (03131) 414-40
UNITED KINGDOM
Roland (U.K.) Ltd.
Atlantic Close, SWANSEA SA7 9FJ, UNITED KINGDOM TEL: (01792) 702701
MIDDLE EAST
BAHRAIN
Moon Stores
No.1231&1249 Rumaytha Building Road 3931, Manama 339, BAHRAIN TEL: 17 813 942
EGYPT
Al Fanny Trading O ce
9, EBN Hagar Al Askalany Street, ARD E1 Golf, Heliopolis, Cairo 11341, EGYPT TEL: (022)-417-1828
IRAN
MOCO INC.
Jadeh Makhsous Karaj (K-9), Nakhe Zarin Ave. Jalal Street, Reza Alley No.4 Tehran 1389716791, IRAN TEL: (021)-44545370-5
ISRAEL
Halilit P. Greenspoon & Sons Ltd.
8 Retzif Ha'alia Hashnia St. Tel-Aviv-Yafo ISRAEL TEL: (03) 6823666
JORDAN
MUSIC HOUSE CO. LTD. FREDDY FOR MUSIC
P. O. Box 922846 Amman 11192, JORDAN TEL: (06) 5692696
KUWAIT
EASA HUSAIN AL-YOUSIFI & SONS CO.
Al-Yousi Service Center P.O.Box 126 (Safat) 13002, KUWAIT TEL: 00 965 802929
LEBANON
Chahine S.A.L.
George Zeidan St., Chahine Bldg., Achra eh, P.O.Box: 16-5857 Beirut, LEBANON TEL: (01) 20-1441
OMAN
TALENTZ CENTRE L.L.C.
Malatan House No.1 Al Noor Street, Ruwi SULTANATE OF OMAN TEL: 2478 3443
QATAR
AL-EMADI TRADING & CONTRACTING CO.
P.O. Box 62, Doha, QATAR TEL: 4423-554
SAUDI ARABIA
Adawliah Universal Electronics APL
Behind Pizza Inn Prince Turkey Street Adawliah Building, PO BOX 2154, Al Khobar 31952, SAUDI ARABIA TEL: (03) 8643601
SYRIA
Technical Light & Sound Center
PO Box 13520 Bldg No.49 Khaled Abn Alwalid St. Damascus, SYRIA TEL: (011) 223-5384
U.A.E.
Adawliah Universal Electronics APL
Omar bin alkhattab street,  sh round about, nayef area, deira, Dubai, U.A.E. TEL: (04) 2340442
NORTH AMERICA
CANADA
Roland Canada Ltd. (Head O ce)
5480 Parkwood Way Richmond B. C., V6V 2M4, CANADA TEL: (604) 270 6626
Roland Canada Ltd. (Toronto O ce)
170 Admiral Boulevard Mississauga On L5T 2N6, CANADA TEL: (905) 362 9707
U. S. A.
Roland Corporation U.S.
5100 S. Eastern Avenue Los Angeles, CA 90040-2938, U. S. A. TEL: (323) 890 3700
As of Apr. 1, 2013 (ROLAND)
For C.A. US (Proposition 65
WARNING
)
* 5 1 0 0 0 3 7 4 8 6 - 0 1 *
Loading...