Rockwell Automation Kinetix 5100 Installation Manual

Installation Instructions
Original Instructions
Kinetix 5100 AC Line Filter
Catalog Numbers 2198-DB111-F, 2198-DB127-F, 2198-DB310-F, 2198-DB324-F, 2198-DB335-F, 2198-DB356-F,
Top ic Pa ge
Summary of Changes 1
Before You Begin 2
Install the AC Line Filter 2
AC Line Filter Dimensions 3
AC Line Filter Specifications 5
Additional Resources 6
This publication provides installation instructions for the AC line filters used with Kinetix® 5100 servo drives. Use these instructions for installing and wiring your AC line filter. For more information on installing and wiring your AC line filter, see Kinetix 5100 Single-axis EtherNet/IP™ Servo Drives Users Manual, publication 219 8-UM0 04.

Summary of Changes

2198-DB418-F, 2198-DB433-F
This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes.
Top ic Pa ge
Added new Kinetix 5100 AC line filter catalog numbers. Throughout Updated drawings in the AC Line Filter Dimensions section. 3 Updated the AC Line Filter Specifications table. 5
Kinetix 5100 AC Line Filter Installation Instructions

Before You Begin

For general guidelines when laying out your panel and mounting your AC line filter, refer to the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001.
For guidelines specific to your application, refer to the Kinetix 5100 Single-axis EtherNet/IP Servo Drives Users Manual, publication 2198 -UM004.
ATTENTION: To avoid personal injury or damage to equipment due to hazardous voltages, follow these guidelines when installing your AC line filter. NEC and local regulations always take precedence.
• Disconnect mains power before installation.
• Verify that the rated voltage is compatible with the local supply voltage.
• Connect the earth ground connection first when you make connections.

Install the AC Line Filter

Mount the line filter to the cabinet panel with hardware as specified in this table.
Cat. No. Mounting Bolt
2198 -DB111 -F
2198 -DB12 7-F
2198-DB310-F
2198-DB324-F
2198-DB335-F
2198 -DB35 6-F
2198-DB418-F M5 (#10-24) 1.6…2.0 (13.9…17.70)
2198-DB433-F
(1) Piggyback mounting of the drive to the line filter is available only for 2198-DB418-F and hardware Rev 1.1 or later of 2198-DB111-F,
2198-DB127-F, 2198-DB310-F, 2198-DB324-F.
M5 (#10-24) 1.6…2.0 (13.9…17.70)
Tor que Val ue N•m (lb•in)
Mounting Bolt
(for piggyback mounting of the drive)
M5 (#10-24) 1.6…2.0 (13.9…17.70)
See the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001,
(1)
Tor que Val ue N•m (lb•in)
(1)
for techniques on how
to make proper high-frequency (HF) bonds to improve overall system performance.
For wiring guidelines specific to your application, see the Kinetix 5100 Single-axis EtherNet/IP Servo Drives User Manual, publication 2
198-UM004.
2 Rockwell Automation Publication 2198-IN017C-EN-P - August 2020
Kinetix 5100 AC Line Filter Installation Instructions
54.0
(2.13)
6.5
(0.26)
223.0 (8.78)
234.0 (9.21)
72.0
(2.83)
54.0
(2.13)
5.5
(0.22)
270
(10.63)
(Minimum)
30.0
(1.18)
5.5
(0.22)
55.0
(2.17)
223.0 (8.78)
23.0
(0.91)
20.0
(0.79)
5.5
(0.22)
5.5
(0.22)
54.0
(2.13)
6.5
(0.26)
223.0 (8.78)
234.0 (9.21)
72.0
(2.83)
54.0
(2.13)
5.5
(0.22)
270
(10.63)
(Minimum)
30.0
(1.18)
5.5
(0.22)
55.0
(2.17)
223.0 (8.78)
23.0
(0.91)
20.0
(0.79)
5.5
(0.22)
5.5
(0.22)
Dimensions are in mm (in.).

AC Line Filter Dimensions

For line filter dimensions specific to your application, see the Kinetix Servo Drives Specifications Technical Data, publication KNX-TD003.
AC Line Filter Dimensions (Catalog numbers 2198-DB111-F and 2198-DB310-F)
Rockwell Automation Publication 2198-IN017C-EN-P - August 2020 3