Rockwell Automation 40CA4 User Manual

INSTALLATION INSTRUCTIONS
or
22 Seri
5000
+
PHOTOSWITCH
MINIATURE SIDE VIEW
TRANSMITTED BEAM CONTROL, BULLETIN 40CA4/47CN4-4000
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION REFER TO PUBLICATION PGĆ9000
BULLETIN NUMBER TYPE RESPONSE TIME
40CA4-4000
+
47CN4-4002
40CA4-4000
+
47CN4-4003
40CA4-4000
+
47CN4-4004
40CA4-4000
+
47CN4-4003
Light Source
Receiver
Light Source
Receiver
Light Source 75(22.8m) Not Recommended Not Recommended
Receiver
Diffuse 1.5(.45m) 5 (1.52m)
Refer to
22 Series 4000
or
es
OPERATING DISTANCE
15(4.57m) 40 (12.2m) 26 (7.92m)
25(7.62m) 75 (22.8m) 49 (14.93m)
40(12.2m) 110 (33.5m) 72 (21.94m)
75(22.8m) 200 (70m) 130 (39.62m)
140(42.68m) Not Recommended Not Recommended
22DJ9-4000 22DJ9-4001
With 60-1711 Extended Lens
With 60-1711 Extend Lens
With 60-1711 Extended Lens
22DJ4-5000 22DJ9-5000
SPECIFICATIONS
Field of View 5°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
with 60–1711 4.5°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmitting LED Infrared, 880nm. . . . . . . . . . . . . . . . . . . . . . . .
Ambient Temperature Range –40°F to 185°F (–40°C to 85°C). .
Approvals UL Listed and CSA Certified. . . . . . . . . . . . . . . . . . . .
Operating Environment NEMA 3, 4, 12, 13 and IP66 (IEC529). .
Housing High impact chemically resistant Housing. . . . . . . . . . . .
Cable
Light Source 2 conductor vinyl jacketed cable 10 (3m). . . . . . .
Receiver 2 conductor vinyl jacketed cable 10 (3m). . . . . . . . . .
OPERATING DISTANCE SELECTION
The maximum operating distance is based on installing the control in a relatively clean environment. Normal industrial environment ac­tually ranges from moderately dusty to extremely dirty. Greater oper- ating margin (excess gain) may be required, which can be obtained by reducing the operating distance of the control. (optics should be cleaned regularly.)
TYPICAL RESPONSE CURVE
100X
50x 40x
30x
20x
10x
5x 4x
3x
OPERATING MARGIN
2x
1x
Recommended Operating Range Derating For normal" Industrial Environments
10% 20% 30% 40% 50% 100%
Percent of Maxium Operating Range
T
Transmitted Beam Operating
Range Selection
2
Recommended Operating Range Derating For dirty" Industrial Environments
T
1
INSTALLATION
The control must be securely mounted on a firm, stable surface or support. A mounting which is subject to excessive vibration or shift­ing may cause intermittent operation.
DIMENSIONS
NO. (60Ć1711) EXTENDED
LENDS ACCESSORY (IF
USED)
61/64 (24.1)
VISIBLE LED
ALIGNMENT AND
OPERATION
INDICATOR ON
40CA4
1
/4-18NPSM
9/16 (14.3)
11/16 (17.5)
13/16 (20.6)
1"
(25.4)
1ă17/32 (38.9)
5/8 (15.9)
13/64 O.D. (5.16)
P.V.C. JACKETED
57/64 (22.6)
2ă27/32 (72.2)
CABLE
WIRING
All external wiring should conform to the National Electric Code and applicable local codes. See wiring diagrams for external connec­tions. For maximum electric shielding, rigid conduit is recommended for extensions of scanner wiring. DO NOT RUN PHOTODETEC­TOR WIRES AND LINE VOLTAGES IN THE SAME CONDUIT.
WIRING DIAGRAMS
PLUGĆIN
CONTROL MODULE
47CN4 AND 47SN1
RECEIVERS
40CA4 AND 40SA1
LED SOURCES
Notes:
1. Ground receiver housing (machine ground O.K.)
2. Ground terminal 4.
BLK
RED
SH
RED
WHT
SH
1
2
3
4
GROUND THIS
TERMINAL
22 SERIES 4000
CONTROL BASE
WIRING DIAGRAMS
WITH UNIVERSAL FUNCTION BASE #60–2120
OPEN COLLECTOR (NPN) CURRENT SINK
OUTPUT TO POWER EXTERNAL LOADS
OR TO #61-2124 OUTPUT BASE
SERIES
5000
L1
L2
OUT
PS( -)
120VAC
1 2 3
BLK RED RED
WHT
RECEIVER
LED SOURCE
#60–2120 BASE
CONNECT ALL SHIELDS TO TERMINAL PS (-)
WITH MULT–MODULE FUNCTION BASE #60–2123
OPEN COLLECTOR (NPN) CURRENT SINK
OUTPUT TO POWER EXTERNAL LOADS
OR TO #61-2124 OUTPUT BASE
OUTPUT
RECEIVER
LED SOURCE
BLK RED RED
WHT
OUT 1 2 3 PS (-)
#60-2123
SERIES
5000
PS (+) PS (-)
OUT
1
24VDC
( + ) ( - )
#60–2123 BASE
CONNECT ALL SHIELDS TO TERMINAL PS (-)
ALIGNMENT
Set the amplifier to the light operate mode. Adjust the sensitivity to the maximum setting, turning the sensitivity potentiometer clock­wise. Aim the light source at the receiver until the alignment indicator on the amplifier turns on.
To be certain that the beam is centered, sweep the receiver at the light source in the horizontal plane and determine the position where the alignment indicator turns on and then off. Do the same in the verti­cal plane. Set the beam halfway between both positions.
It may be necessary to reduce the sensitivity to a lower setting for transparent or translucent materials or to detect objects smaller that the effective beam.
Publication PA–9200(A)
November 1992
Supercedes Publication PA–7913
Loading...