The Kinetix® 6000M integrated drive-motor system transmits network signals across a series of
network cables between each integrated drive-motor (IDM) unit in the system.
The network terminator is a male M12 connector with a backshell cover that seals the connector.
The network terminator is installed on the last IDM unit in the system, where it terminates the
network by returning the data signals through the daisy-chained network that connects the IDM
units to the IPIM module.
2090-CTSRP Network Terminator
2 Kinetix 6000M Network Terminator
Important User Information
Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for
the Application, Installation and Maintenance of Solid State Controls, publication SGI-1.1
Automation sales office or online at http://www.rockwellautomation.com/literature
between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the
wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that
each intended application of this equipment is acceptable.
In no event will Rockwell Automation, Inc. be responsible or li able for indirect or consequential damages resulting from the use or
application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibilit y or liability for
actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software
described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is
prohibited.
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNIN G: Identifies information about practices or circumstances that can cause an explosion in a
hazardous environment, which may lead to personal injury or death, property damage, or economic
loss.
, is available from your local Rockwell
) describes some important differences
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or
death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard and
recognize the consequences.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, drive or motor, to alert
people that dangerous voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, drive or motor, to alert
people that surfaces may reach dangerous temperatures.
IMPORTANTIdentifies information that is critical for successful application and understanding of the product.
Publication 2090-IN036B-EN-P - March 2012
Kinetix 6000M Network Terminator 3
Before You Begin
Observe the following precautions when installing the connector in a servo system. Failure to
observe these safety notices could result in personal injury or damage to the motor and
equipment.
SHOCK HAZARD: To avoid the hazard of electrical shock, be sure to ground any cable providing
power at a minimum of one point. To prevent the build-up of electrical energy, factory-supplied
cables use one of these grounding techniques:
• Bond the overall shield to the connector housing.
• Make sure there is a dire ct connect ion-to-ground for each cable shield.
• Connect an exposed cable braid or a ground wire, if present, to the power cable clamp,
housing, or another suitable chassis ground.
Failure to observe these safety procedures could result in personal injury or equipment damage.
ATT EN TI ON : Arcing or unexpected motion can occur if cables are connected or disconnected while
power is applied to the IDM sy stem. Before working on an IDM system, disconnect power and wait
the full time interval as indicated in the warning on the IPIM module or verify the DC bus voltage at
the IPIM module measures less than 50V DC.
Failure to observe this precaution could result in severe bodily injury or loss of life, and damage to
the product will occur.
Install the Network Terminator
Follow these steps when installing the 2090-CTSRP network terminator.
1. Verify power to the IPIM module is removed before making any connections or
disconnecting any components of the system.
ATT EN TI ON : Arcing or unexpected motion can occur if cables are connected or disconnected while
power is applied to the IDM sy stem. Before working on an IDM system, disconnect power and wait
the full time interval as indicated in the warning on the IPIM module or verify the DC bus voltage at
the IPIM module measures less than 50V DC.
Failure to observe this precaution could result in severe bodily injury or loss of life, and damage to
the product will occur.
2. Attach the network terminator to the network-out connector on the last IDM unit in
the system.
ATTENTION: The network terminator mounts on the connector in a fixed position, and cannot be
moved to a different position.
Attempting to rotate the network terminator could result in damage to the motor and equipment.
Publication 2090-IN036B-EN-P - March 2012
4 Kinetix 6000M Network Terminator
2094-SEPM-B24-S
IPIM Module
2090-CHBIFS8-12AAxx
IPIM-to-IDM Hybrid Cable
Connects the IPIM Module to the First IDM Unit
2090-CHBP8S8-12AAxx
Hybrid Cable
2090-CTHP8
Hybrid Terminator
MDF-SB1xxx
Last IDM Unit
2090-CTSRP
Network Terminator
2090-CNSSPSS-12AAxx
or 2090-CNSSPRS-AAxx
Network Cable
2090-CNSRPRS-AAxx
Network Cable
MDF-SB1xxx
First IDM Unit
DATA OUT +
DATA OUT -
DATA IN +
DATA IN -
3. Apply 0.8…1.2 N•m (7…11 lb•in) of torque to fully seat the contacts and secure the
connection.
Kinetix 6000M Cable Routing Diagram
R
G
R
G
R
G
R
G
PORT 1 PORT 2 NETWORK
2090-CTSRP Network Terminator Outline, Pinout, and Schematic
Publication 2090-IN036B-EN-P - March 2012
1
2
3
4
5
Kinetix 6000M Network Terminator 5
Specifications
Additional specifications for each cable are available in the Kinetix Motion Accessories Technical
Data, publication GMC-TD004.
Attribute 2090-CTSRP
Wire si ze 22 AWG
Connector install torque 0.8…1.2 N•m (7…11 lb•in)
Additional Resources
These documents contain additional information concerning related products from Rockwell
Automation.
Resource Description
Kinetix 6000M Integrated Drive-Motor System User
Manual, publication 2094-UM003
Kinetix Motion Control Selection Guide,
publication GMC-SG001
Information on installing, configuring, starting, and
troubleshooting a servo drive system with a servo motor.
Information on the installation of your Kinetix 6000M
integrated drive-motor.
A glossary of industrial automation terms and abbreviations.
Information, examples, and techniques designed to minimize
system failures caused by electrical nois e.
Catalog numbers and product specifications, including
performance, environmental, certifications, load force, and
dimension drawings for Allen-Bradley rotary motors.
Catalog numbers, specifications, and dimensions for
Allen-Bradley servo drive accessories.
General product specifications for Kinetix motion control
products.
You can view or download publications at http://www.rockwellautomation.com/literature
.
To order paper copies of technical documentation, contact your Allen-Bradley® distributor or
Rockwell Automation® sales representative.
Publication 2090-IN036B-EN-P - March 2012
6 Kinetix 6000M Network Terminator
Notes:
Publication 2090-IN036B-EN-P - March 2012
Notes:
Kinetix 6000M Network Terminator 7
Publication 2090-IN036B-EN-P - March 2012
Rockwell Automation Support
Rockwell Automation provides tec hnical information on the Web to assist you in using its products.
At http://www.rockwellautomation.com/support
links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. You can also visit
our Knowledgebase at http://www.rockwellautomation.com/knowledgebase
forums, software updates, and to sign up for product notification updates.
For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect support
programs. For more information, contact your local distributor or Rockwell Automation representative, or visit
http://www.rockwellautomation.com/support/
Installation Assistance
If you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual.
You can also contact a special Customer Support number for initial help in getting your product up and running.
Rockwell Automation tests all o f its products to ensure that they are fully operational when shipped from the manufacturing facility.
However, if your product is not functioni ng and needs to be returned, follow these procedures.
, you can find technical manuals, technical and application notes, sample code and
for FAQs, technical information, support chat and
.
at
, or contact your local
United States
Outside United StatesPlease contact your local Rockwell Automation representative for the return procedure.
Contact your distributor. You must provide a Customer Support case number (call the phone number
above to obtain one) to your distributor to complete the return process.
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document,
complete this form, publication RA-DU002
Allen-Bradley, Kinetix, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 2090-IN036B-EN-P - March 2012PN-143961