WARNING: Product installation & operation
This equipment must be installed and operated in accordance
with the Raymarine instructions provided. Failure to do so could
result in personal injury, damage to your boat and/or poor
product performance.
WARNING: Electrical safety
Make sure you have switched off the power supply before you
start installing this product.
WARNING: Navigational safety
Although we have designed this product to be accurate and
reliable, many factors can affect its performance. Therefore, it
should serve only as an aid to navigation and should never
replace commonsense and navigational judgement. Always
maintain a permanent watch so you can respond to situations as
they develop.
EMC conformance
All Raymarine equipment and accessories are designed to the best industry
standards for use in the recreational marine environment.
The design and manufacture of Raymarine equipment and accessori es conform to
the appropriate Electromagnetic Compatibility (EMC) standards, but correct
installation is required to ensure that performance is not compromised.
Handbook information
To the best of our knowledge, the information in this handbook was correct when
it went to press. However, Raymarine cannot accept liability for any inaccuracies
or omissions it may contain.
In addition, our policy of continuous product improvement may change
specifications without n otice. Therefore, Raymarine cannot ac cept liability for any
differences between the product and the handbook.
Page 4
iiST60+ Tridata Instrument Owner’s Handbook
Product disposal
Waste Electrical and Electronic (WEEE) Directive
The WEEE Directive requires the recycling of waste electrical and
electronic equipment.
Whilst the WEEE Directive does not apply to some of Raymarine's products, we
support its policy and ask you to be aware of how to dispose of this product.
The crossed out wheelie bin symbol, illustrated above, and found on our products
signifies that this product should not be disposed of in general waste or landfill.
Please contact your local dealer, national distributor or Raymarine Technical
Services for information on product disposal.
Page 5
iii
Contents
Important information.................................................................................................. i
Safety notices .......................................................................................................... i
WARNING: Product installation & operation.......................................... i
WARNING: Electrical safety.......................................................................... i
WARNING: Navigational safety................................................................... i
EMC conformance ................................................................................................... i
Handbook information ............................................................................................ i
Product disposal ..................................................................................................... ii
Contents ............................................................................................................... iii
Index ................................................................................................................................. 45
Page 8
viST60+ Tridata Instrument Owner’s Handbook
Page 9
Preface vii
Preface
Introduction
Thank you for purchasing a Raymarine product. We are sure your ST60+
instrument will give you many years of trouble-free operation.
This handbook describes how to install and use the Raymarine ST60+
Tridata instrument. This instrument provides accurate depth, speed, trip and timer
information, on a high quality Liquid Crystal Display (LCD). The instrument is
constructed in a rugged weather-proofed case to provide reliable performance,
even under the most demanding conditions.
ST60
+
TRIDATA
D
E
P
T
H
S
P
E
E
D
T
R
IP
R
ESE
T
D8169-1
Data inputs
The ST60+ Tridata instrument can fulfil master and/or repeater roles by receiving
data either from the appropriate transducers and/or from a SeaTalk
instrumentation system.
SeaTalk
SeaTalk enables a number of compatible instruments to operate as a single,
integrated navigational system. Instruments in a SeaTalk system are linked by
means of a single cable, which feeds both power and data. Instruments can
therefore be added to the system by plugging them into the network. SeaTalk is
flexible enough to adapt to any number of compatible instruments without
requiring a central processor. SeaTalk can also communicate via an interface, with
non-SeaTalk equipment using the internationally-accepted National Marine
Electronics Association (NMEA) protocol.
Page 10
viiiST60+ Tridata Instrument Owner’s Handbook
In a SeaTalk system, each instrument can be either a master or dedicated repeater
unit. A master instrument is directly connected to a transducer (the device that
provides the raw data), and provides data and control appropriate to its function,
to all other equipment on the SeaTalk network. A repeater instrument is not
directly connected to a transducer but displays information provided by other
equipment in the SeaTalk network.
Stand alone operation
In Stand alone operation, the ST60+ Tridata instrument is connected only to the
relevant transducer and does not display information from, or provide
information to, any other instruments.
Remote control
When connected to SeaTalk, the ST60+ Tridata instrument can be controlled
remotely by a SeaTalk Remote Keypad Unit, to provide instant remote access to
the various display readouts.
Mounting options
A standard ST60+ instrument is surface-mounted at the required location. If you
do not want to surface mount your ST60+ instrument, options are available for:
• Flush mounting. If you have ordered the flush mounting option a flush mount
bezel and four fixing screws are also provided.
• Bracket mounting.
Page 11
Preface ix
Parts supplied
Unpack your ST60+ instrument and check that the following items are present:
• Item 1, ST60+ Tridata instrument fitted with standard bezel for surface
mounting.
•Item 2, Fixing studs (2).
• Item 3, Thumb nuts (2).
•Item 4, Gasket.
• Item 5, Depth transducer.
• Item 6, Speed transducer, plus bung (not illustrated).
• Item 7, SeaTalk interconnection cable.
• Item 8, Power cable.
• Item 9, Instrument Cover.
• Item 10, Owner’s Handbook. A Warranty document and fitting templates are
included in this Handbook.
• Item 11, Cue Card.
Spare spade terminals are also provided, to re-terminate the transducer cable if it
has to be cut to facilitate installation.
Note:
The above packing list is for an ST60+ Tridata system. Where an instrument is pur-
chased separately, Speed and Depth transducers are not included.
Page 12
xST60+ Tridata Instrument Owner’s Handbook
DEPTH
SPEED
RESET
TRIP
1
4
32
32
56
7
9
ST60+
Tridata
Instrument
Owner's
Handbook
8
ST60+ Tridata
Instrument
ST60+TRIDATA
RESET
DEPTH
TRIP
SPEED
Quick Start Guide
1110
D8170-1
Page 13
Chapter 1: Operation
1.1Getting started
This handbook describes how to operate, maintain and install the Raymarine
ST60+ Tridata instrument.
WARNING: Calibration requirement
To ensure this product performs at its best on your boat, you
MUS T c ali brat e it be fore u se, i n accordance with the instructions
in
Chapter 4, Calibration
successfully calibrated it.
Switching on and off
All the time that power is applied to the instrument, you can use the depth
button to switch the instrument off and on as follows:
• To switch the instrument off, hold down the
5 seconds. After this time, a switch off count down of 4 seconds occurs. Keep
the
depth button pressed during this period, to switch off the instrument.
• To switch the instrument back on, hold down the
mately 1 second.
When the power supply is switched off, none of the instrument buttons (including
depth) has any effect.
Notes: (1)
Each time power to the instrument is switched on, the instrument is initially in the on condition. You do not need to use the
switch the instrument on.
(2)
When the instrument is on, the operation of the
perform other operating functions, as described below.
. Do NOT use the product until you have
depth button for approximately
depth button for approxi-
depth
button to
depth
button will
1
Displayed information
The ST60+ Tridata instrument screen is divided into three separate areas, each of
which displays a separate type of information, as shown in the following
illustration.
Page 14
2ST60+ Tridata Instrument Owner’s Handbook
Depth
Speed
Trip, log, water
temperature & timer
Screen layout
1.2Normal operation
Use the flow charts in this Chapter to operate your ST60+ Tridata instrument.
Flow charts are provided for:
•Using the
master instruments, this also gives access to depth alarm level information,
and allows you to set the alarm levels.
•Using the
and Velocity Made Good (VMG) to windward.
•Using the
information.
All button presses are momentary unless otherwise stated.
Depth information
Use the depth button to select the required information, as shown in the
the depth button
metres, as selected during user calibration (see
Using with fishfinder products
Depth information is normally obtained from the Depth transducer, fitted as part
of an ST60+ Depth or Tridata system. However, when the ST60+ Tridata
instrument is connected to a SeaTalk system, to which a compatible fishfinder is
also connected, the depth information is provided by the fishfinder a ll the time the
fishfinder is switched on.
depth button. This gives access to current depth information. On
speed button. This gives access to maximum speed, average speed
trip button to gain access to log, trip, water temperature and timer
illustration. The depth measurement units are either feet or
D8171-1
Chapter 4, Calibration
Using
).
Current depth display
The current depth screen shows the title DEPTH, the selected depth units and the
depth measurement. It also shows a depth trend indicator, which is either an up
arrow to show seabed rising or a down arrow to show seabed falling.
If for any reason depth information is lost, the DEPTH title will flash once per
second and the displayed depth value will be the last good reading.
Page 15
Chapter 1: Operation3
Depth alarm level displays
Alarm displays are available if the instrument is operating as a master. Each
display is identified by the presence of an alarm symbol ( )and either an up
depth trend arrow for a shallow alarm or a down depth trend arrow for a
deep alarm. The shallow and deep anchor alarms are identified by means of an
additional anchor symbol ( ).
Current depth
Anchor deep
alarm threshold
depth
Anchor
shallow alarm
threshold
Using the depth button
depth
To enable/disable an alarm:
select the relevant screen then hold down
reset
for 2 seconds
To enter/leave alarm adjust mode
Select relevant
screen then press
resettrip
+
To adjust an alarm level:
In adjust mode, use
either
or
resettrip
to set the alarm level
depth
depth
depth
Shallow alarm
threshold
Deep
alarm
threshold
D8172-1
You can enable and disable individual alarms by pressing the reset button for
2 seconds, while the relevant alarm screen is displayed.
Each alarm screen is displayed for a nominal 7 seconds, and if no action is taken
during that time, the display will timeout to the current depth display.
Page 16
4ST60+ Tridata Instrument Owner’s Handbook
An alarm condition occurs if:
• The depth is less than the SHALLOW or SHALLOW anchor level.
• The depth is greater than the DEEP anchor level.
• The depth crosses the DEEP level.
An alarm condition is indicated by an alarm buzzer and a flashing alarm symbol
( ) on the display. SHALLOW or DEEP alarms are indicated by up and down
arrows respectively, and for anchor alarms, the anchor symbol ( ) is displayed.
When the instrument is operating as a master, you can check the alarm levels and
if necessary set them up. If an alarm is not enabled, the associated display shows
an OFF legend.
Adjusting alarm levels
To adjust the alarm levels:
1. Use the
2. Press the
3. When you have set the required value, press the
Note:
ment is disabled, you cannot enter adjust mode.
depth button to display the alarm screen you want to adjust
trip and reset buttons simultaneously to enter adjust mode, then
use either the
level.
again, to save the alarm setting and exit the adjust mode.
Adjustment of the shallow alarm level can be disabled during calibration. If adjust-
trip button (to decrease) or the reset button (to increase) the
trip and reset buttons
Speed information
Use the speed button to select the required information, as shown in the
the speed button
(KTS), miles per hour (MPH) or kilometres per hour (KMH), as selected during
user calibration (see
The maximum speed, average speed and VMG to windward are each displayed
for 7 seconds, and if no action is taken during that time, the display will timeout to
the Boat speed display.
Boat speed
Shows the current speed and selected speed units. The speed information is
obtained either from a speed transducer, or derived from Speed Over Ground
(SOG). SOG is available if you are connected to a SeaTalk system to which a
compatible GPS is also connected.
The source of speed information (transducer or SOG) is selected during Dealer
calibration (see
illustration. The speed measurement units are either knots
Chapter 4, Calibration
Chapter 4 , Calibration
).
).
Using
Page 17
Chapter 1: Operation5
Boat speed
VMG to
windward
speed
speed
Average
speed
2 s
reset
Resets to
zero
Resets to
current boat
speed
speed
speed
Maximum
speed
Using the speed button
Maximum speed
The screen shows the maximum speed attained since the last reset.
The maximum speed value is reset automatically at power-up. If the instrument is
operating as a master, the maximum speed can also be reset manually by pressing
the
reset button for 2 seconds.
Average speed
The screen shows the average speed since the last reset.
The average speed value is reset automatically at power-up. If the instrument is
operating as a master, the average speed can also be reset manually by pressing
the
reset button for 2 seconds.
D8173-1
Velocity made good (to windward)
Velocity made good (VMG) information is available if your instrument is part of a
SeaTalk system to which a SeaTalk-compatible wind instrument is also
connected.
Distance, temperature & timer information
The trip button gives access to log, trip, water temperature and timer displays, as
shown in the
Using the trip button
illustration.
Page 18
6ST60+ Tridata Instrument Owner’s Handbook
Water temperature
The water temperature is shown in either degrees Celsius (°C) or Fahrenheit (°F),
as set during calibration (see
Chapter 4, Calibration
).
Timers
The count-up timer and the two race-start timer times are either in seconds (S) or
minutes (M), depending on the counter values.
Refer to the
Once you have done this, press the
a timer is running, the delimiter (
the
Using the trip button
flow diagram to display the required timer.
reset button to start the timer running. When
. or : ) flashes. When a timer is running, press
reset button for lap times. To stop a timer, press the reset button.
trip
Trip
Log
trip
Race start
timer 2*
Hold down
reset
for 1 s to reset timer
to start value.
trip
Water
temperature
trip
Count-up
timer*
trip
Race start
timer 1*
*When timer stopped
reset
starts timer*When timer running
reset
gets lap time
Using the trip button
To reset a timer to the start value, stop it then hold down the reset button for
1 second.
Once a timer is running, you can leave the timer page and select any other display.
The counter will continue to run in the background.
D8174-1
Page 19
Chapter 1: Operation7
Race-start timers
You can set each race-start timer to any whole-minute value from 1 to 15 minutes.
Note:
When the instrument is first installed, the race-start timers are set to 4 and 5 min-
utes respectively.
To set a race-start timer:
1. Use the trip button as shown in the
Using trip button
flow diagram to select
the required race-start timer.
2. Simultaneously press the
trip and reset buttons to enter the race-start timer
adjust mode.
3. Use either the
4. Simultaneously press the
trip or reset button to set the required value.
trip and reset buttons to save the value and leave
the race-start timer adjust mode.
Increase time
reset
+
trip
Set race-start timer
Timer adjust mode
reset
+
trip
reset
OR
trip
Decrease time
If you are using one of the race-start timers and the timer buzzer is enabled, the
buzzer will:
• Double-beep every minute.
• Beep three times at the start of the last 30 seconds.
• Beep once for each of the last 10 seconds.
• Beep for 2 seconds at zero.
The timer buzzer is enabled or disabled as part of the calibration procedure (see
Chapter 4, Calibration
Note:
After a race-start timer has counted-down to zero, it will then start counting up.
).
Log
The Log screen shows the total distance covered by the vessel since the
instrument was fitted.
D8175-1
Page 20
8ST60+ Tridata Instrument Owner’s Handbook
Trip screen
The trip screen shows the distance covered since the trip value was last reset.
The trip value is reset automatically at power-up, and if the instrument is
operating as a master, the trip value can also be reset manually by pressing the
reset button for 3 seconds.
1.3Display settings
Illumination
When the instrument is first powered up, the display illumination is set to its
lowest (courtesy) level, to facilitate initial access to the button s.
To adjust the level of display illumination:
1. Hold down the
mination-adjust mode.
2. There are four preset illumination levels. Use the
through these levels until you reach the level you want.
3. Press any other button to leave the illumination-adjust mode.
Note:
The display will also return to normal operation 7 seconds after the last button
press.
depth button for approximately one second, to enter the illu-
depth button to cycle
Contrast
To adjust the display contrast:
1. Hold down the
contrast-adjust mode.
2. There are four preset contrast settings. Use the
these settings until you achieve optimum display quality.
3. Press any other button to leave the contrast-adjust mode.
Note:
The display will also return to normal operation 7 seconds after the last button
press.
depth button for approximately two seconds, to enter the
1.4Remote control
When it is connected to SeaTalk, the ST60+ Tridata instrument can be controlled
remotely with a SeaTalk Remote Keypad Unit. Remote control of an instrument is
indicated by a REMOTE legend on the display, to indicate that the button pad
has control.
Details on how to use the remote control facility are given in the
Keypad Owner’s Handbook
depth button to cycle through
SeaTalk Remote
.
Page 21
Chapter 2:Maintenance & Troubleshooting
2.1Maintenance
Servicing and safety
• Raymarine equipment should be serviced only by authorised Raymarine service technicians. They will ensure that servicing procedures and replacement
parts used will not affect performance. There are no user-serviceable parts in
any Raymarine product.
• Some products generate high voltages, and so never handle the cables/connectors when power is being applied to the equipment.
• When powered up, all electrical equipment produces electromagnetic fields.
These can cause adjacent pieces of electrical equipment to interact with one
another, with a consequent adverse effect on operation. In order to minimise
these effects and enable you to get the best possible performance from your
Raymarine equipment, guidelines are given in the installation instructions, to
enable you to ensure minimum interaction between different items of equipment, i.e. ensure optimum Electromagnetic Compatibility (EMC).
• Always report any EMC-related problem to your nearest Raymarine dealer.
We use such information to improve our quality standards.
• In some installations, it may not be possible to prevent the equipment from
being affected by external influences. In general this will not damage the
equipment but it can lead to spurious resetting action, or momentarily may
result in faulty operation.
9
Instrument
Certain atmospheric conditions may cause condensation to form on the
instrument window. This will not harm the instrument and can be cleared by
increasing the illumination setting to Level 3.
Periodically clean your ST60+ instrument with a soft damp cloth. Do NOT use
chemical and abrasive materials to clean the instrument.
Transducers
Refer to the Installation and Maintenance instructions supplied with the
transducers.
Page 22
10ST60+ Tridata Instrument Owner’s Handbook
Cabling
Examine all cables for chafing or other damage to the outer shield, and where
necessary, replace and re-secure.
2.2Troubleshooting
Preliminary procedures
Changes in the electronic environment may adversely affect the oper-ation of
your ST60+ equipment. Typical examples of such changes are:
• Electrical equipment has recently been installed or moved aboard your vessel.
• You are in the vicinity of another vessel or shore station emitting radio signals.
If you appear to have a problem, first ensure that the EMC requirements (see
Chapter 3, Installation
problem.
Fixing faults
CAUTION: Prevention of flooding
If you need to remove the transducer insert, have the transducer
bung to hand and secure it in the transducer body immediately
after the insert has been removed, to prevent excessive ingress
of water.
All Raymarine products are subjected to comprehensive test and quality
assurance programmes prior to packing and shipping. However, if a fault occurs,
the following table may help to identify and rectify the problem.
FaultCauseRemedy
) are still being met before further investigating the
Instrument display
blank.
No speed or temperature information.
No speed information.Speed transducer
No power supply.Check power supply.
Speed transducer
cabling problem.
paddle wheel
fouled.
Check SeaTalk cabling and connector
security.
Check fuse/circuit breaker.
Check cabling and security of transducer connections.
Clean paddle wheel.
See CAUTION below.
Page 23
Chapter 2: Maintenance & Troubleshooting11
FaultCauseRemedy
No exchange of information between SeaTalk
instruments.
Failure of group of
instruments in SeaTalk
chain.
LAST flashes or dashes
displayed continuously
(depth greater than 3
feet).
LAST flashes while under
way.
SeaTalk cabling
problem.
SeaTalk cabling or
connector problem.
Depth transducer
or connection p roblem.
Aerated water
Boat wake
Prop wash etc
Check the security of SeaTalk connectors.
Disconnect instruments one by one,
to isolate faulty unit.
Check the security of SeaTalk connections between functioning and
non-functioning instruments.
Check depth transducer cable and
security of transducer connections.
Ensure readings stabilise when clear
of disturbed water.
Technical support
Raymarine provides a comprehensive customer support service, on the world
wide web and by telephone help line. Please use either of these facilities if you are
unable to rectify a problem.
World wide web
Please visit the Customer Support area of our web site at:
www.raymarine.com
As well as providing a comprehensive Frequently Asked Questions section and
servicing information, it also gives e-mail access to the Raymarine Technical
Support Department and a details of the locations of Raymarine agents,
worldwide.
Telephone help line
If you do not have access to the world wide web, please call:
• 1-800-539-5539, extension 2444 or
• (603) 881-5200 extension 2444
Page 24
12ST60+ Tridata Instrument Owner’s Handbook
Help us to help you
When requesting service, please quote the following product information:
•Equipment type.
• Model number.
• Serial number.
• Software issue number.
To find out the software version number of your ST60+ Tridata instrument:
1. During normal operation, hold down the
approximately 4 seconds, to display the software version (VEr) screen.
depth and speed buttons for
Software version
D8247_1
2. Note the software version number, then hold down the depth and speed
buttons for approximately 2 seconds, to return to normal operation.
Page 25
Chapter 3: Installation
This chapter describes how to install the ST60+ Tridata instrument, and
associated Speed and Depth transducers. The transducers are fitted in the hull of
the vessel and connected to the rear of the instrument. The actual type of
transducers depends on the type of hull in which they are to be installed.
For advice, or further information regarding the installation of this equipment,
please contact the Raymarine Product Support Department or your own National
Distributor.
3.1Planning your installation
Before starting the installation, spend some time considering the best positions
for both transducer and instrument, such that the
Guidelines
Site requirements
Transducers
Depth
(below) are satisfied.
2.94 in (75 mm )
diameter
Speed
Site Requirements
2.94 in (75 mm )
diameter
and the
13
EMC
2.0 in (51 mm )
diameter
2.94 in (75 mm )
diameter
3.75 in (95 mm )
0.19 in (5 mm)
2.0 in (51 mm)
diameter
2.94 in (75 mm)
diameter
4.69 in (119 mm)
0.19 in (5 mm)
D8686-1
Page 26
14ST60+ Tridata Instrument Owner’s Handbook
The transducer types required for the various hull types are as follows:
Hull materialSpeed transducerDepth transducer
Glass reinforced
plastic (GRP)
E26031 Through hull plastic31-188-4-02 Through hull plastic or
M78718 Retractable through hull
SteelE26031 Through hull plastic31-188-4-02 Through hull plastic or
M78718 Retractable through hull
AluminiumE26031 Through hull plastic31-188-4-02 Through hull plastic or
M78718 Retractable through hull
WoodM78716 Through hull bronze M78714 Through hull bronze or
M78719 Retractable through hull
bronze
Other transducer types are also available for specific requirements. For further
details, contact your local Raymarine dealer.
For accurate speed and depth readings the transducers should be sited within the
clear water flow areas indicated by the shaded areas in the following diagram.
Sailing vessel
Transducer siting
Planing power
vessel
Displacement power
vessel
D4349-1
Page 27
Chapter 3: Installation15
The transducers should also:
• Be ahead of the propellers (by a minimum of 10% of the water line length).
• Be at least 150 mm (6 in) away from the keel (ideally ahead of the keel if a sailing yacht).
• Be as near as possible to the centre line of the vessel.
• Be clear of other through-hull fittings or projections.
• Have sufficient clearance inside the hull to fit the nut.
• Have 100 mm (4 in) of headroom to allow for withdrawal.
In addition to the above requirements, the depth transducer must be mounted
within 10
0
of the vertical, forward, aft and athwart ships.
10˚ maximum
Maximum transducer angle
D4350-3
Instrument
CAUTION: Keep the rear of the instrument dry
Keep the rear of instrument dry. Failure to observe this caution
could result in damage if water enters the instrument through
the breathing hole or comes into contact with the electrical
connectors.
ST60+ instruments can be fitted either above or below deck, provided the rear of
the instrument is sited where it is protected from contact with water.
Page 28
16ST60+ Tridata Instrument Owner’s Handbook
Each instrument must also be positioned where:
• It is easily read by the helmsman
• It is protected against physical damage
• It is at least 230 mm (9 in) from a compass
• It is at least 500 mm (20 in) from radio receiving equipment
• There is reasonable rear access for installation and servicing
With standard bezel
(surface mount)
diameter
3.54 in (90 mm)
4.53 in (115 mm)
With low profile bezel
(flush mount)
4.33 in (110 mm)
4.90 in (124 mm)
0.25 in
(6.50 mm)
0.93 in
(23.5 mm)
1.4 in
(35 mm)
0.6 in
(15 mm)
3.54 in (90 mm)
ST60+ instrument dimensions
EMC Installation Guidelines
All Raymarine equipment and accessories are designed to the best industry
standards for use in the recreational marine environment.
Their design and manufacture conforms to the appropriate Electromagnetic
Compatibility (EMC) standards, but correct installation is required to ensure that
performance is not compromised. Although every effort has been taken to ensure
that they will perform under all conditions, it is important to understand what
factors could affect the operation of the product.
The guidelines given here describe the conditions for optimum EMC performance,
but it is recognized that it may not be possible to meet all of these conditions in all
situations. To ensure the best possible conditions for EMC performance within the
diameter
490 in (124 mm)
D8146-1
Page 29
Chapter 3: Installation17
constraints imposed by any location, always ensure the maximum separation
possible between different items of electrical equipment.
For optimum EMC performance, it is recommended that wherever possible:
• Raymarine equipment and cables connected to it are:
• At least 3 ft (1 m) from any equipment transmitting or cables carrying
radio signals e.g. VHF radios, cables and antennas. In the case of SSB
radios, the distance should be increased to 7 ft (2 m).
• More than 7 ft (2 m) from the path of a radar beam. A radar beam can nor-
mally be assumed to spread 20 degrees above and below the radiating
element.
• The equipment is supplied from a separate battery from that used for engine
start. Voltage drops below 10 V in the power supply to our products, and
starter motor transients, can cause the equipment to reset. This will not damage the equipment, but may cause the loss of some information and may
change the operating mode.
• Raymarine specified cables are used. Cutting and rejoining these cables can
compromise EMC performance and must be avoided unless doing so is
detailed in the installation manual.
• If a suppression ferrite is attached to a cable, this ferrite should not be
removed. If the ferrite needs to be removed during installation it must be reassembled in the same position.
Suppression Ferrites
The following illustration shows typical cable suppression ferrites used with
Raymarine equipment. Always use the ferrites supplied by Raymarine.
D3548-2
Connections to Other Equipment
If your Raymarine equipment is to be connected to other equipment using a cable
not supplied by Raymarine, a suppression ferrite MUST always be attached to the
cable near the Raymarine unit.
Page 30
18ST60+ Tridata Instrument Owner’s Handbook
3.2Procedures
As it is not practical to describe procedures for all possible installation scenarios,
the procedures given here describe the broad requirements for installing the
Speed and Depth transducers and the ST60+ Tridata instrument. Adapt these
procedures as appropriate, to suit your individual requirement.
CAUTION: Maintain structural safety
Where it is necessary to cut holes (e.g. for cable routing and
instrument mounting), ensure that these will not cause a hazard
by weakening critical parts of the vessel’s structure.
Unpacking
Unpack your ST60+ equipment and check that the items described in
are present.
Each ST60+ instrument is supplied with a standard bezel for surface mounting.
Optional mounting kits are available for flush mounting and bracket mounting
the instrument. If you have ordered the flu sh mounting option a flush mount bezel
and four fixing screws are also provided.
Fitting the instrument
The ST60+ Tridata instrument can be installed using one of a number of different
mounting options:
• Surface mounting. Gives a profile of approximately 24 mm.
• Flush mounting. Gives a profile of approximately 6 mm.
• Bracket mounting.
The ST60+ instruments can also be mounted behind a panel with just the
instrument dial and buttons visible.
Introduction
Surface mounting
To surface mount your ST60+ instrument (see the
1. Ensure that:
• The selected location is clean, smooth and flat.
• There is sufficient space behind the selected location to accommodate the
rear of the instrument and connectors.
Surface mounting
illustration):
Page 31
Chapter 3: Installation19
Surface mounting
41213552
D8147-1
2. Apply the surface mount template (supplied at the rear of this handbook) to
the selected location and mark the centres for the fixing studs (1) and the
aperture (3) that will take the rear casing of the instrument.
3. Drill out the two 5 mm fixing stud clearance holes (2).
4. Cut out the clearance hole (3) then remove the template.
5. Peel off the protective sheet from the self-adhesive gasket (4) then stick the
gasket into position on the rear of the instrument.
6. Screw the two fixing studs into the threaded sockets on the rear of the instrument.
7. Mount the assembled instrument, studs, bezel and gasket into the panel.
Secure from behind with the thumb nuts (5).
Flush mounting
The Flush Mounting Kit uses a flush mount bezel to reduce the fitted profile of the
instrument, to approximately 0.25 in (6 mm) above the panel fascia.
Fitting the flush mount bezel
In order to flush-mount your ST60+ instrument, you must first replace the
standard bezel with the flush mount bezel as follows:
1. Hold the instrument in both hands with the display towards you.
Page 32
20ST60+ Tridata Instrument Owner’s Handbook
2. Using both thumbs, gently press an upper corner of the instrument from the
bezel, then remove the bezel from the instrument. Retain the rubber keypad
which is released when the bezel is removed.
3. Referring to the
Fitting the flush mount bezel
illustration, insert the panel
seal (8) in the corresponding recess on the back of the flush mount bezel (7).
D8148-1
Fitting the flush mount bezel
879101112
D8149-1
Page 33
Chapter 3: Installation21
4. Place the instrument (11) face upwards on a flat surface, then place the rubber keypad (10) in position around the display window (i.e. so that each button outline is located over its associated button on the instrument).
5. Place the keypad seal (9) in position on the keypad (i.e. so that the holes in the
seal accept the appropriate keypad buttons).
6. Place the assembled flush mount bezel and panel seal, in position on the
instrument, so that the rubber keys are correctly located in the holes on the
bezel, then clip the bezel and instrument together.
CAUTION: Use the correct screws
It is essential that only screws of the correct size are used to
secure the instrument to the bezel. Failure to observe this caution
could result in damage to both the instrument and the bezel.
7. Using the four, self-tapping screws (12) provided, secure the instrument and
bezel together. Fit the screws from the rear of the instrument and tighten
them sufficiently to secure the instrument and bezel together. DO NOT OVERTIGHTEN.
Flush mounting procedure
Flush mount your instrument (see the
Flush mounting
illustration) as follows:
1. Assemble the ST60+ instrument and flush mount bezel as described under
Fitting the flush mount bezel
.
2. Ensure that:
• The panel on which you intend to mount the instrument is between 3 mm
and 20 mm thickness.
• The selected location is clean, smooth and flat.
• There is sufficient space behind the selected loca tion to accommodate the
rear of the instrument and connectors.
3. Apply the flush mount template (supplied at the rear of this handbook) to the
selected location and mark out the aperture into which the assembled instrument and bezel will sit.
4. Cut out the aperture (3) for the assembled instrument and bezel and remove
the template.
5. Peel off the protective sheet from the self-adhesive gasket (4) then stick the
gasket into position on the rear of the bezel.
6. Screw the two fixing studs (1) into the threaded sockets on the rear of the
instrument.
7. Mount the assembled instrument, studs, bezel and gasket into the panel.
Page 34
22ST60+ Tridata Instrument Owner’s Handbook
Flush mounting
4135651
8. Locate the flush mount bracket (6) onto the fixing studs and secure the assembly to the panel with the thumb-nuts (5).
Bracket mounting
A Control Unit Mounting Bracket (Part No. E25009) enables you to mount your
ST60+ instrument in locations where other forms of mounting are impractical.
Although this provides a useful alternative method for securing your instrument,
it is only suitable for use in positions where the instrument will not be exposed to
water.
To bracket mount your ST60+ instrument, do so in accordance with the Control
Unit Mounting Bracket
Instruction Sheet
.
Fitting transducer
The ST60+ Tridata instrument is supplied, with appropriate through-hull Speed
and Depth transducers.
Each transducer is supplied with detailed instructions for installation and
maintenance. Before attempting to install a transducer, read these instructions
and the
Site requirements
for transducers described in this Chapter.
D8150-1
Page 35
Chapter 3: Installation23
Once you are satisfied you can meet all the installation requirements, install the
transducer in accordance with the accompanying installation instructions.
Running transducer cable
Each transducer type has a 14 m (45 ft) cable fitted with spade terminals for
connection to the ST60+ Tridata instrument. The manner in which you run the
cable will depend on the locations of the transducers and instrument. The
following guidelines are provided:
• If the cable has to be fed through the deck, always use a proprietary deck
gland.
• Where cables are fed through holes, always use grommets to prevent chafing.
• Secure long cable runs so they do not present a hazard.
• Do not route the cable through bilges.
• Wherever possible, route the cable away from fluorescent lights, engines,
radio transmitting equipment, as these may cause interference.
• The transducer cables are fitted with spade connectors for direct connection
to the rear of the instrument. However, it may be necessary to remove these to
facilitate installation, e.g. if a cable has to be routed through narrow apertures. Extra spade connectors are provided, to replace any that are removed
when running transducer cables. When fitting spade connectors, prepare the
cable as at (a) in the following illustration, then fold back the wire strands and
insert into the spade connector as at (b). Ensure the wire strands do not
extend beyond the rear of the spade connector insulation, then crimp the connector to the wire.
50 mm
6 mm
(a)
3 mm
(b)
D4467-6
Observing the above guidelines, run the transducer cables to the ST60+ Tridata
instrument.
Page 36
24ST60+ Tridata Instrument Owner’s Handbook
Connecting the instrument
Types of connection
The ST60+ Tridata instrument, can be connected:
• As a stand-alone, master instrument connected directly to a Speed and/or
Depth transducer.
• As a SeaTalk repeater.
• To fulfil both repeater and master roles by being connected both to the transducer and to SeaTalk.
If instruments are connected to SeaTalk, no separate power connection is
necessary. Where a SeaTalk system includes an autopilot, the power for the
system is provided by the autopilot.
A range of Raymarine SeaTalk extension cables is available to connect separated
instruments. These cables are supplied with a SeaTalk connector fitted to each
end. A junction box can be used to join cables.
Fitting ferrites
If you are going to connect a Depth transducer to an ST60+ Tridata instrument, fit
suppression ferrites near the instrument end of the SeaTalk and Depth transducer
cables, as follows.
1. Release the catch on the ferrite, open it up then snap it closed around the
cable.
2. Position the ferrite as close as possible to the instrument end of the cable
(maximum 1 foot (300 mm) from the end) and fit a tie-wrap on the cable
either side of the ferrite, to hold it in position.
Note:
It is NOT necessary to fit a ferrite to the Speed transducer cable.
<1 ft (300 mm)
SeaTalk cable
Ferrites
SeaTalk cable
Depth transducer cable
Tie-wraps
D8804-1
Page 37
Chapter 3: Installation25
Signal connections
Make the necessary connections to your ST60+ instrument (see the
ST60+ Tridata instrument
illustration).
SeaTalk cableSeaTalk cable
D
E
P
T
H
D
E
E
P
S
Connection to
Black
Blue
Cable from Depth transducer
Cable from Speed transducer
Connections to ST60+ Tridata instrument
Screen
Brown
White
Screen
Green
Red
D8176-1
Power supply connections
CAUTION: Protect the power supply
Ensure that the 12 V power supply for the instrument is
protected by a suitably rated fuse or protective circuit breaker.
SeaTalk systems
Ensure that the power supply for the SeaTalk bus is protected by a 5 A fuse or
circuit breaker.
Systems with a large number of instruments on the SeaTalk bus may require
connections to the power supply from each end of the system (‘ring-main’ style),
to maintain sufficient voltage throughout the system.
Page 38
26ST60+ Tridata Instrument Owner’s Handbook
This requirement depends on the total length of the cable run and the total
number of instruments in the system, as follows:
Cable runNo. of instrumentsPower connections
Up to 10 m13 maximum
26 maximum
Up to 20 m7 maximum
13 maximum
Red
5 A fused,
12 V dc supply
(typically provided
by autopilot)
Screen
Red
Screen
1234
20
SeaTalk power connections
19
1
2
1
2
Instruments
5 to 16
18
17
D4311-1
Stand alone instruments
Stand-alone instruments are not connected to SeaTalk and therefore need to be
connected to an alternative 12 V power source. Power cables are available in 2 m
and 9 m lengths.
To fit a pow er cab le:
1. Ensure the intended power source is switched off. If you are using a 12 V battery, ensure the power cable is not connected to the battery.
2. Run the power cable from the instrument to a suitable 12 V dc power source.
3. If the cable has not already been trimmed at the power supply end:
• Cut the cable to length and trim back an appropriate amount of the outer
sheath.
• Cut back and insulate the yellow wire.
4. Connect the screen to the power supply 0 V terminal.
5. Connect the red wire, via a 3 A fuse or protective circuit breaker, to the power
supply +12 V terminal.
Page 39
Chapter 3: Installation27
3 A over-current
circuit breaker
12 V dc
supply
Red
Screen
Power connections for stand-alone instrument
3.3Switching on
Switch on the power to your ST60+ instrument. When the power is on, you can
use the
depth button to switch the instrument on and off as described in
Chapter 1, Operation
Use the procedures in
how you want them
WARNING: Calibration requirement
To ensure this product performs at its best on your boat, you
MUS T c ali brat e it be fore u se, i n accordance with the instructions
in
Chapter 4, Calibration
successfully calibrated it.
EMC conformance
Always check the installation before going to sea to make sure that it is not
affected by radio transmissions, engine starting etc.
.
Chapter 1, Operation
. Do NOT use the product until you have
D4310-7
to set the backlighting and contrast
Page 40
28ST60+ Tridata Instrument Owner’s Handbook
Page 41
Chapter 4: Calibration
4.1Introduction
The ST60+ Tridata instrument is set up with factory-programmed default settings,
so in order to optimise the performance of the instrument on board a particular
vessel, the procedures in this Chapter must be carried out immediately after the
completion of installation and before the equipment is used for navigational
purposes.
Where practicable, the calibration procedures are presented diagrammatically to
show the sequence of button presses and the resulting displays. Adjustment
instructions are given as applicable.
4.2User calibration
The User calibration procedures enable you to:
• Set the required units for depth readings.
• Set the offset for depth readings, i.e. determine whether depth readings are
from the keel of the vessel or from the water line.
• Lock the shallow alarm.
• Set the required units for speed readings.
• Set the speed resolution.
• Select the log distance units
• Set the speed readings on the instrument to be a true indication of the actual
speed of the vessel.
• Select temperature units.
• Calibrate for correct temperature readings.
• Set timer alarm buzzer on or off.
Separate routines are provided for the User calibration of the depth and speed
functions. To carry out either of these routines:
1. Power up the ST60+ Tridata instrument.
2. Hold down the
that the User calibration entry screen is displayed.
3. Carry out the User calibration procedures for
depth and speed buttons for approximately 2 seconds so
Depth
and
Speed
29
.
Page 42
30ST60+ Tridata Instrument Owner’s Handbook
To start User calibration
hold down
speed
and
depth
for approximately 2 seconds
User calibration
entry screen
Press
either
User calibration - depth
see illustration
depth
or
User calibration - speed
see illustration
speed
Starting User calibration
Depth
To calibrate the depth functions:
1. With the User calibration entry screen displayed, press the
2. Referring to the
procedure. Use the
and
reset buttons to set the required values at each screen.
User calibration - depth
depth button to cycle from screen to screen and the trip
Set depth
units
depth
Shallow
From User calibration
entry screen
alarm
lock
tripreset
to set required values
illustration, carry out the calibration
Set depth
offset
Use
or
D8177-1
depth button.
depth
depth
User calibration - depth
D8178-1
Page 43
Chapter 4: Calibration31
Depth units
You can set either FEET or METRES.
Depth offset
Depths are measured from the transducer to the sea bed. However, you can use
the depth offset screen to apply offsets to this distance, so that the displayed
depth reading represents either the depth from the keel or the depth from the
water line. In order to do this, you need to know the vertical separation between
the transducer position and:
• The bottom of the keel.
• The water line.
Depth offsets
+ve offset
values
Offset value
of 0.0
-ve offset
values
D4352-2
Page 44
32ST60+ Tridata Instrument Owner’s Handbook
Setting offset values
WARNING: Use the correct depth offset
The use of the correct depth offset is critical to the safety of the
vessel. If incorrect offset values are applied, this could result in
misleading depth information being displayed with a
consequent risk of running aground. Take great care to ensure
you set the correct value.
Use the trip (decrement) and reset (incremen t) buttons to set the required offset
value:
• If you want to display the depth reading from the transducer, set a value of
0.0.
• If you want to apply a water line offset, adjust the displayed reading until the
appropriate positive offset value is shown.
• If you want to apply a keel offset, adjust the displayed reading until the appropriate negative offset value is shown.
Shallow alarm lock
When set to on, prevents alteration to the shallow depth alarm level.
Speed
An important reason for speed calibration is to ensure that speed readings
displayed on the instrument are a true indication of the actual speed of the vessel.
In
User calibration, Speed
• Automatically set the displayed speed reading to be the same as the Speed
Over Ground (SOG) (if SOG data is available).
• Manually apply a calibration factor, to set the displayed speed to the required
value.
If neither of the above methods are suitable, you can carry out a speed calibration
run over a measured distance, to enable the instrument to calculate the correct
calibration factor. This is described as part of
, you can:
Intermediate
calibration.
To calibrate the speed functions:
1. With the User calibration entry screen displayed, press the
2. Referring to the
User calibration - speed
illustration, carry out the calibration
speed button.
procedure. Use the speed button to move from screen to screen and the trip
and reset buttons to set the required values at each screen (except Adjust to
SOG display).
Page 45
Chapter 4: Calibration33
From User calibration
entry screen
Set speed
units
speed
Set speed
resolution
speed
Set timer
alarm
Temperature
calibration
Set
temperature
units
speed
speed
speed
Set log
units
Set correct
speed
If SOG available from
SeaTalk
Adjust
to SOG
speed
reset
+
timer
If SOG NOT
available
Adjust
Cal Factor
speedspeed
User calibration - speed
Set speed units
Select either KTS (knots), MPH (miles per hour) or KMH (kilometres per hour),
as required.
D8170-1
Page 46
34ST60+ Tridata Instrument Owner’s Handbook
Set speed resolution
Select resolution of either 0.01 or 0.1 as required.
Set log units
Select either NM (nautical miles), SM (statute miles) or KM (kilometres), as
required.
Setting the correct speed
Set the displayed (current) speed using one of the following methods:
• If SOG is available from SeaTalk, use the Adjust to SOG screen to automatically set the current speed to. You must be running in slack tide conditions to
successfully use this method.
• Manually apply a calibration factor by means of the Cal factor adjust screen,
to set the displayed speed value to your best estimate of the vessel’s speed.
If neither of the above methods is suitable, use the
described under
a measured distance. This enables the instrument to calculate the correct
calibration factor.
Adjust to SOG
The Adjust to SOG screen is displayed only if SOG data is available from SeaTalk.
The current SOG is displayed in the bottom section of the display (SG12.8 in the
illustration), and the current speed registered by the instrument, as large figures
in the middle section of the display (12.3 in the illustration).
It is recommended that, if you are running in slack tide conditions, you press the
reset button for 3 seconds, to accept the SOG as the current speed.
If you do not wish to accept SOG as the current speed, press the
buttons together to select the Cal factor adjust display.
Intermediate calibration
to carry out a speed calibratio n run over
Speed calibration
trip and reset
procedure
Cal factor adjust
The Cal factor adjust screen enables you to manually adjust the calibration factor.
It shows the current calibration factor in the bottom section of the display (CF
1.00 in the illustration), and the current speed as large figures (12.3 in the
illustration).
Use the
trip or reset button to adjust the calibration factor so that the current
speed is the speed through the water.
If SOG data is available from SeaTalk, you can turn to the Adjust to SOG screen by
pressing the
Note:
bration procedure (part of Intermediate calibration).
trip and reset button s.
If neither of the above methods gives satisfactory results, carry out the Speed cali-
Page 47
Chapter 4: Calibration35
Set temperature units
Select either °C or °F, as required.
Temperature calibration
Set the display to show the current water temperature.
Timer alarm buzzer
Switches the count-up and race-start timer audible alarm on the ST60+ Tridata
instrument being calibrated, on and off.
Leaving User calibration
Hold down the depth and speed buttons for 2 seconds, to save your settings,
exit User calibration and resume normal operation.
4.3Intermediate calibration
Intermediate calibration enables you to:
• Check the instrument software version.
• Check the instrument status - either YES (master) or NO (repeater). You can
also change the depth status, as required. This feature is particularly useful in
preventing interference when using another product (e.g. a fishfinder) that
operates at 200 kHz.
• Carry out a calibration run over a measured distance to ensure accurate speed
readings.
To start Intermediate calibration, hold down the
approximately 4 seconds (see
Intermediate calibration
depth and speed buttons for
flow chart).
Hold downfor approximately 4 seconds
Intermediate calibration
depthspeed
Software
version
and
speed
speed
Instrument
status
Carry out speed calibration
Speed calibration - sheets 1 & 2
(or NO for repeater)
speed
as detailed in
D8180-1
Page 48
36ST60+ Tridata Instrument Owner’s Handbook
To set the instrument status:
1. Press the
depth button to select the Instrument status screen.
2. Press the trip and reset buttons simultaneously to enter the depth adjust
mode, then press either
trip or reset to set the required status, i.e. either
YES (for master operation) or NO (for repeater operation).
Note:
You must not allocate more than one master depth instrument in any system.
3. Press the trip and reset buttons simultaneously again, to leave the adjust
mode.
Note:
If a fishfinder is connected to the same SeaTalk system as your ST60+ Tridata instrument and is switched on, all ST60+ Depth and Tridata instruments in the system will
display FISHFINDER depth information from SeaTalk. Under these conditions, a master
YES
ST60+ Tridata instrument will act as a slave, and in Intermediate calibration, the
legend will change to
SLA
wh en n ot in ad jus t mo de.
Speed calibration
The speed calibration procedure involves carrying out two runs over a measured
distance, to enable a calibration factor to be determined and applied to your
ST60+ Tridata instrument, to ensure optimum accuracy. Each calibration run
comprises outward and return legs, to minimise the affect of tidal drift when the
calibration factor is determined.
Note:
It is recommended that the speed calibration procedure is carried out in conditions
of minimum tidal drift.
To carry out a speed calibration, start the Intermediate calibration procedure and
use the
speed button to proceed to the Calibration run length screen (see
of the
Speed calibration
flow chart). Proceed with the speed calibration as
follows:
1. With the Calibration Run Length screen displayed, simultaneously press the
trip and reset buttons, to enter adjust mode. In this mode, the displayed run
length flashes on and off.
2. Set the length of the intended calibration run, using either the
decrement or the
reset button to increment the run length value. You can set
any value between 0.25 and 2.50.
3. Press trip and reset buttons together to commence the speed calibration. The
Cal status screen is displayed. The information at the bottom of the screen
alternates between Strt 1 and the calibration factor (CF) currently applied.
4. Start the outward leg of the calibration run and as you pass the start point,
press the
speed button, so that the text out shows at the bottom of the
screen. As the calibration run proceeds, the displayed value will increment.
sheet 1
trip button to
Page 49
Chapter 4: Calibration37
from Intermediate calibration
(Instrument status display )
Calibration
run
length
At the end
of the
outward cal
run press
speed
trip
+
reset
Complete the
outward leg of
the first cal run
At the start of
the return leg
press
speed
Use either
resettrip
or
to set length of calibration run
outward leg
trip
+
reset
At the start
of the
press
speed
Complete the
return leg of
the first cal run
This is the
end of the
first cal run
You can now either carry
out a second cal run or
exit speed calibration
Speed calibration, sheet 1
Exit speed
calibration
At the end of the
return leg press
speed
Carry out
second
calibration run
depth
+
speed
to save the
cal factor
Go to sheet 2
Exit to Instrument
status display
(Intermediate
calibration)
D8181-1
Page 50
38ST60+ Tridata Instrument Owner’s Handbook
5. At the end of the outward leg, press the speed button again so that:
•The text rEtrn is flashing at the bottom of the screen.
• The displayed distance freezes. Note that this value may not be the same
as the measured distance due to errors introduced by tidal flow.
6. Turn the vessel round, start the return leg and as you do so, press the
speed
button so the rEtrn legend stops flashing and the displayed value increments.
7. At the end of the return leg, press the
speed button to end the calibration
run. At this point:
•The text Strt 2 alternating with the new calibration factor is displayed
at the bottom of the screen.
• The displayed distance freezes. This value should be very close to the
actual (measured) distance of the calibration run.
From sheet 1
At the end of
the return leg
speed
Complete the
return leg of
the second cal run
press
speed
Speed calibration, sheet 2
8. Carry out one of the following actions:
• If you are satisfied with the results of the first calibration run, press the
depth and speed buttons together, to store the new calibration factor,
exit speed calibration and return to the Instrument status screen.
Speed
calibration is
now complete
Complete the
outward leg of
the second cal run
At the end of the
outward leg, press
At the start of the
return leg press
speed
Press
depth
speed
+
to save the
cal factor
speed
Exit to Instrument
status display
(Intermediate
calibration)
D8182-1
Page 51
Chapter 4: Calibration39
• If you want to carry out a second calibration run:
i. Press
ii. Use the procedure described above in steps 4 to 7, to complete the
iii. Press the
speed to start the second calibration run (see
Speed calibration
second run. At the end of the second run, the text END alternating
with the new calibration factor is displayed at the top of the screen.
depth and speed buttons together, to store the new cali-
bration factor, exit speed calibration and return to the Instrument status screen.
flow chart).
sheet 2
of the
Leaving Intermediate calibration
Hold down the depth and speed buttons for 2 seconds, to save your settings,
exit Intermediate calibration and resume normal operation.
4.4Dealer calibration
The Dealer calibration procedures enable the following parameters to be set:
• User calibration on/off.
• Data source for speed information.
• Speed response.
• Depth response.
• Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This enables
you to re-apply the factory settings if you want to reset the instrument to a known
operating condition.
To commence Dealer calibration, hold down the
together for approximately 12 seconds, to select the Dealer calibration entry page
(see
Dealer calibration
together, to enter the calibration screen sequence.
diagram). Then press the trip and reset buttons
depth and speed buttons
Use the
depth button to move from screen to screen and the trip or the rest
button to set the required values at each screen.
User calibration on/off
Press either the trip or reset button to toggle the User calibration on or off as
required. With off selected, User calibration and Intermediate calibration are
both disabled.
Page 52
40ST60+ Tridata Instrument Owner’s Handbook
Speed select (SOG on/off)
Use this screen to select the data source for displayed speed information.Press
either the
SOG OFF selected, speed information is obtained from the speed transducer.
This is the recommended setting if you have a speed transducer fitted.
With SOG ON selected, speed information is obtained from the SOG input.
trip or reset button to toggle SOG ON or OFF as required. With
speeddepth
Hold down
for approximately 12 seconds
Entry screen
+
resettrip
+
Factory defaults
depth
Boat Show
Dealer calibration
Calibration
on/off
depth
Use
resettrip
or
to set required values
Mode
Depth response
depthdepth
To leave calibration,
hold down
speeddepth
+
for approximately 2 seconds
depth
Speed
select
Speed
response
depth
Page 53
Chapter 4: Calibration41
Response settings
The response values for both SPEED and DEPTH determine the frequency at
which information is updated. A low number provides a smooth response and a
high number a much livelier update.
Use the
trip (decrement) and reset (increment) buttons to set the required value.
Response values are from 1 to 15.
Boat show mode
CAUTION: Do NOT enable Boat Show Mode
Do NOT enable Boat Show Mode. This must be used only for
demonstration purposes.
Ensure that the Boatshow Mode Use is set to OFF. If necessary, use the trip or
reset button to achieve this.
Factory defaults
You can use this screen to reset the operating parameters to the factory default
values. Use the
Note that the selection you make at this screen will be applied when you exit the
screen, so be sure you make the correct selection.
To retain the current values,ensure that the display shows
trip and reset buttons to make the required selection.
NO.
If you want to apply the factory defaults, change the display to YES. If you do
this, the values you have set up will be overwritten by the factory defaults when
you leave this screen.
Leaving Dealer calibration
Hold down the depth and speed buttons for 2 seconds to save y our settings, exit
Dealer calibration and resume normal operation.
Page 54
42ST60+ Tridata Instrument Owner’s Handbook
Page 55
Glossary
APPApparent
AVEA verage
AWAApparent Wind Angle (relative to the vessel)
AWSApparent Wind Speed
BTWBearing To Waypoint
CMGCourse Made Good
COGCourse Over Ground
DMGDistance Made Good
DTWDistance To Waypoint
EMCElectro Magnetic Compatibility
43
ETAEstimated Time of Arrival
GPSGlobal Positioning System
HDGHeading
KMKilometer(s)
KMHKilometers per hour
KTSKnot(s)
LATLatitude
LCDLiquid Crystal Display
LONLongitude
LT RL it er (s )
Page 56
44ST60+ Tridata Instrument Owner’s Handbook
MMagnetic or meters
MAGMagnetic
MOBMan Overboard
MPHMiles per hour
NMNautical mile(s)
ResponseThe sensitivity of an instrument, to data changes.
RFRadio Frequency
SeaTalkRaymarine proprietary communication system which links products, to provide a
SMStatute mile(s)
SOGSpeed Over Ground
SPDSpeed
TTrue
TTGTime To Go
TWATrue Wind Angle relative to the vessel, taking into account the speed of the vessel.
TWDTrue Wind Direction.
TWSTrue Wind Speed.
VMGVelocity Made Good.
WPWaypoint
XTECross Track Error
single, integrated system sharing power and data.
Page 57
Index
45
A
Average speed, 5
B
Backlighting adjustment, 8
, 7
Boat log
Boat show mode
Boat speed
, 7
Buzzer
C
Calibration requirement, 1, 27
Cleaning
Condensation
Contrast adjustment
Current depth
D
Dealer calibration, 39
Depth alarms
adjusting levels
Depth information
current depth
Depth offset
Display setup
Disposing of the product
E
EMC information, i, 9, 16, 27
F
Factory de faults, 41
H
Help lines, 11
I
Installing
instrument
bracket mounting
flush mounting
requirements
signal connections
surface mounting
applying factory defaults
backlighting
contrast
correct speed
depth offset
depth units
distance units
instrument response
race start timer
resolution
selecting speed data source
speed units
temperature reading
temperature units
User calibration access
Shallow alarm lock
Site requirements
instrument
transducers
Software version
Software version number
Speed calibration
methods, 34
procedure
purpose
Speed information
average speed
boat speed
maximum speed
VMG
Switching on/off
, 8
, 8
, 34, 36
, 31
, 31
, 34
, 7
, 34
, 33
, 35
, 32
, 15
, 13
, 35
, 36
, 32
, 5
, 4
, 5
, 5
, 1, 27
, 41
, 35
, 12
, 39
, 41
, 40
T
Technical support, 11
Temperature (water)
Timer buzzer
switch on/off
Timers
, 6
, 7
buzzer
race start timers
setting
Tri p d istanc e
Troubleshooting
U
User calibration, 29
V
Velo city Made Good, 5
W
Water temperature, 6
, 6
, 35
, 7
, 7
, 8
, 10
Page 59
SURFACE MOUNT
Template
from shaded areas only
Instrument edge
1.185 in (30.1 mm)1.18 in (30.0 mm)
TOP
Cut hole
3.54 in (90 mm)
diameter
Remove material
Drill hole, 3/16 in (5 mm)
diameter in 2 positions
Sun cover edge
1.77 in (45.0 mm)1.76 in (44.6 mm)
D8157-1
SURFACE MOUNT template for
ST60+ Instruments
Page 60
Page 61
TOP
Control Unit
FLUSH MOUNT
Template
Remove material from shaded area only
4.47 in (113.5 mm)
4.3 in (109 mm)
Drill hole,
1/4 in (6.5 mm)
diameter in
4 positions
Instrument edge
Sun cover edge
FLUSH MOUNT template for
ST60+ Instruments
Page 62
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.