Quadra-Fire 43M-ACC-MBK, 43ST-ACC-B Installation Manual

Installation Manual
Installation & Appliance Set-Up
INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.
NOTICE: DO NOT DISCARD THIS MANUAL
WARNING
If the information in these instruc-
4300 WOOD APPLIANCE SERIES
Automatic Combustion Control (ACC)
tions is not followed exactly, a
re could result causing property
damage, personal injury, or death.
Model: 43M-ACC-MBK
43ST-ACC-B
Tested and
Listed by
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may over re and generate
poisonous gases (i.e. carbon monoxide).
O-T L
US
C
OMNI-Test Laboratories, Inc.
Portland
Oregon USA
• Do not store or use gasoline or other am­mable vapors and liquids in the vicinity of this or any other appliance.
• Do not over re - If appliance or chimney connector glows, you are over ring. Over ring will void your warranty.
• Comply with all minimum clearances to
combustibles as specied. Failure to comply may cause a house re.
WARNING
HOT SURFACES! Glass and other surfaces are hot
during operation AND cool down.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as appliance.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
ammable materials.
Keep clothing, furniture, draperies and other ammable materials away.
Installation and service of this appliance should be performed by quali ed personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.
1 7037-172 September 26, 2016
NOTE
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrare.com
Pour obtenir une traduction française de ce manuel, s’il vous
plaît contacter votre revendeur ou visitez www.quadrare.com
4300 Wood Appliance Series ACC
Safety Alert Key:
DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury.
CAUTION! Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.
NOTICE: Indicates practices which may cause damage to the appliance or to property.
TABLE OF CONTENTS
1 Important Safety Information ...........3
A. Appliance Certication .............................................3
B. BTU & Efciency Specications ..............................3
C. Mobile Home Approved ...........................................3
D. Glass Specications ................................................3
E. Non-Combustible Materials ......................................3
F. Combustible Materials ..............................................3
2 Getting Started ..................................4
A
. Design and Installation Considerations ....................... 4
B. Fire Safety ................................................................4
C. Negative Pressure .................................................5
D. Tools And Supplies Needed ....................................5
E. Inspect Appliance and Components ........................5
F. Install Checklist .........................................................6
3 Dimensions and Clearances ............7
A. Appliance Dimensions .............................................7
B. Hearth Protection Requirements .............................10
C. Clearances to Combustibles ...................................12
4 Chimney Systems ...........................13
A. Locating Your Appliance & Chimney .......................13
B. Chimney Termination Requirements .......................14
C. 2-10-3 Rule ............................................................14
D. Chimney Height/Rise and Run ...............................15
E. Venting Components ..............................................15
F. Chimney Systems ....................................................15
G. Installing Chimney Components ..............................17
H. Proper Draft ...........................................................17
5 Appliance Set-Up ............................18
A. Pedestal Assembly and
Ash Removal System (ARS) Installation .................18
B. Access Cover Handle ..............................................20
C. Leg Kit and Ash Removal
System (ARS) Installation........................................20
D. Traditional Leg Installation ......................................22
E. Door Handle Assembly ............................................23
F. Outside Air Kit Installation ........................................23
G. Blower (Optional) ....................................................24
H. Adjusting the Blower Speed Control .......................24
6 Mobile Home Installation ................25
7 Reference Materials ........................ 26
8 Accessory List ................................27
Quadra-Fire is a registered trademark of Hearth & Home Technologies.
2 7037-172 September 26, 2016
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products, their
specications and/or price without notice.
1 Important Safety Information
A. Appliance Certication
4300 Wood Appliance Series ACC
Model: 4300 Millennium & Step Top (ACC)
Uni-Body
Laboratory: OMNI Test Laboratories, Inc.
Report No & Date: 061-S-67-6
Type: Listed Room Heater, Solid Fuel Type
Standard: UL1482 and ULC S627-00 and (UM)
84-HUD, Mobile Home Approved.
The Quadra-Fire 4300 Series Wood Appliance meets the U.S. Environmental Protection Agency’s crib wood emission limits for wood appliances sold after May 15, 2015.
B. BTU & Efciency Specications
EPA Certication #: 656
EPA Certied Emissions: 1.00 grams per hour
*LHV Tested Efciency: 80.2 %
**HHV Tested Efciency: 74.2 %
***EPA BTU Output: 11,800 to 38,300 / hr.
****Peak BTU/Hour Output: 63,700
Vent Size: 6 inches
Firebox Size: 2.30 cubic feet
Recommended Wood Length: 18 inches
Fuel Orientation: Front-to-Back
Fuel Seasoned Cord Wood
*Weighted average LHV (Low Heating Value) efciency using
Douglas Fir dimensional lumber and data collected during EPA emission test.
**Weighted average HHV (High Heating Value) efciency using
Douglas Fir dimensional lumber and data collected during EPA emission test.
***A range of BTU outputs based on EPA Default Efciency and
the burn rates from the low and high EPA tests, using Douglas Fir dimensional lumber.
****A peak BTU out of the appliance calculated using the max-
imum rst hour burn rate from the High EPA Test and the BTU content of cord wood (8600) times the efciency.
C. Mobile Home Approved
This appliance is approved for mobile home installa­tions; when not installed in a sleeping room and when an outside combustion air inlet is provided.
The structural integrity of the mobile home oor, ceil- ing, and walls must be maintained.
The appliance must be properly grounded to the frame of the mobile home with #8 copper ground wire.
Outside Air Kit, part OAK-ACC must be installed in a
mobile home installation.
NOTE: This installation must conform with local codes.
In the absence of local codes you must comply with the
UL1482-07, (UM) 84-HUD and NFPA211 in the U.S.A. and the ULC S627-00 and CAN/CSA-B365 Installation Codes
in Canada.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
For assistance or additional information, consult a qualied
installer, service agency or your dealer.
Hearth & Home Technologies WILL NOT warranty appli­ances that exhibit evidence of over-ring. Evidence of over-ring includes, but is not limited to:
• Warped air tube
• Deteriorated refractory brick retainers
• Deteriorated bafe and other interior components
D. Glass Specications
This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please con­tact your dealer for replacement glass.
E. Non-Combustible Materials
Material which will not ignite and burn, composed of any
combination of the following:
- Steel - Plaster
- Brick - Iron
- Concrete - Tile
- Glass - Slate
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C.
F. Combustible Materials
Material made of/or surfaced with any of the following ma­terials:
- Wood - Compressed Paper
- Plant Fibers - Plastic
- Plywood/OSB - Sheet Rock (drywall)
Any material that can ignite and burn: ame proofed or not,
plastered or non-plastered.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products, their
specications and/or price without notice.
September 26, 2016 7037-172 3
4300 Wood Appliance Series ACC
Install Guide
2 Getting Started
A. Design and Installation Considerations
Consideration must be given to:
• Safety
• Convenience
• Trafc ow
• Chimney and chimney connector required
It is a good idea to plan your installation on paper, using exact
measurements for clearances and oor protection, before
actually beginning the installation. If you are not using an existing chimney, place the appliance where there will be a clear passage for a factory-built listed chimney through the ceiling and roof.
We recommend that a qualied building inspector and your
insurance company representative review your plans before and after installation.
If this appliance is in an area where children may be near it is recommended that you purchase a decorative barrier to go in front of the appliance. away while it is operating and do not let anyone operate this appliance unless they are familiar with these operating instructions.
Remember to always keep children
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national codes and regulations.
• Consult insurance carrier, local building, re ofcials or authori­ties having jurisdiction about restrictions, installation inspection, and permits.
B. Fire Safety
To provide reasonable re safety, the following should be given serious consideration:
1. Install at least one smoke detector on each oor of
your home to ensure your safety. They should be located away from the heating appliance and close to the sleeping areas. Follow the smoke detector manufacturer’s placement and installation instructions, and be sure to maintain regularly.
2. A conveniently located Class A fire extinguisher to
contend with small res resulting from burning embers.
3. A CO detector should be installed in the room with the
appliance.
4. A practiced evacuation plan, consisting of at least two escape routes.
5. A plan to deal with a chimney re as follows:
In the event of a chimney re:
a Evacuate the house immediately
b. Notify re department.
NOTICE: HEARTH & HOME TECHNOLOGIES ASSUMES NO
RESPONSIBILITY FOR THE IMPROPER PERFORMANCE OF THE APPLIANCE SYSTEM CAUSED BY:
• Inadequate draft due to environmental conditions
• Down drafts
• Tight sealing construction of the structure
• Mechanical exhausting devices
• Over drafting caused by excessive chimney heights
• Ideal performance is with height of chimney between 14-16 feet (4.26-4.88m) measured from the base of the appliance.
WARNING
Asphyxiation Risk.
• DO NOT CONNECT THIS APPLIANCE TO A CHIM­NEY FLUE SERVICING ANOTHER APPLIANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
May allow ue gases to enter the house.
4 7037-172 September 26, 2016
C. Negative Pressure
4300 Wood Appliance Series ACC
WARNING
WARNING
Asphyxiation Risk.
• Negative pressure can cause spillage of com­bustion fumes, soot and carbon monoxide.
• Appliance needs to draft properly for safety.
Negative pressure results from the imbalance of air avail­able for the appliance to operate properly. It can be stron­gest in lower levels of the house.
Causes include:
• Exhaust fans (kitchen, bath, etc.)
• Range hoods
• Combustion air requirements for furnaces, water appliances and other combustion appliances
• Clothes dryers
• Location of return-air vents to furnace or air conditioning
• Imbalances of the HVAC air handling system
• Upper level air leaks such as:
- Recessed lighting
- Attic hatch
- Duct leaks
To minimize the effects of negative air pressure:
• Install optional outside air kit with the intake facing prevailing winds during the heating season
• Ensure adequate outdoor air for all combustion appliances and exhaust equipment
• Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance
• Avoid installing the appliance near doors, walkways or small isolated spaces
• Recessed lighting should be a “sealed can” design
• Attic hatches weather stripped or sealed
• Attic mounted duct work and air handler joints and seams taped or sealed
• Basement installations should be avoided
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
• Installation and use of any damaged appliance.
• Modication of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved by Hearth & Home Technologies.
• Operating appliance without fully assembling all components.
• Operating appliance without legs or pedestal attached.
• Do NOT Over re - If appliance or chimney connector glows, you are over ring.
Any such action that may cause a re hazard.
D. Tools And Supplies Needed
Before beginning the installation be sure the following tools
and building supplies are available:
Reciprocating saw Framing material
Pliers High temp caulking material
Hammer Gloves
Phillips screwdriver Framing square
Flat blade screwdriver Electric drill and bits
Plumb line Safety glasses
Level Tape measure
Misc. screws and nails
1/2-3/4 in. length, #6 or #8 self-drilling screws
E. Inspect Appliance and Components
• Remove appliance and components from packaging and inspect for damage.
• Report to your dealer any parts damaged in shipment.
• Read all the instructions before starting the installation. Follow these instructions carefully during the
installation to ensure maximum safety and benet.
September 26, 2016 7037-172 5
WARNING
Fire Risk.
Inspect appliance and components for damage. Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
4300 Wood Appliance Series ACC
F. Install Checklist
ATTENTION INSTALLER:
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.
Customer: __________________________________________________________________________ Date Installed: __________________________________________________________________________ Lot/Address: __________________________________________________________________________ Location of Appliance: ______________________________________________________________ Installer: __________________________________________________________________________ Dealer/ Distributor Phone #: ______________________________________________________________ Serial #: __________________________________________________________________________ Model : __________________________________________________________________________
WARNING! Risk of Fire or Explosion!
Appliance Install
Appliance is leveled and connector is secured to appliance. Hearth extension size/height decided. Outside air kit installed. Floor protection requirements have been met. If appliance is connected to a masonry chimney, it should be cleaned and
inspected by a professional. If installed to a factory built metal chimney, the chimney must be installed according to the manufacturer’s instructions and
clearances.
Follow this Standard Work Checklist
YES IF NO, WHY?
Chimney
Chimney installed, locked and secured in place with proper clearance. Chimney meets recommended height requirements (14-16 feet).
Terminations installed and sealed.
Clearances
Combustible materials not installed in non-combustible areas.
Mantels and wall projections comply with installation manual requirements. Protective hearth strips and hearth extension installed per manual requirements.
Appliance Setup
All packaging and protective materials removed.
All labels have been removed from the door. All packaging materials are removed from inside/under the appliance. Manual bag and all of its contents are removed from inside/under the appliance and given to the party responsible for use and operation.
Hearth & Home Technologies recommends the following:
• That this checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed: Comments communicated to party responsible by on
(Builder/Gen. Contractor) (Installer) (Date)
6 7037-172 September 26, 2016
3 Dimensions and Clearances
28-11/16 in. (729mm)
26-1/4 in. (667mm)
4300 Wood Appliance Series ACC
A. Appliance Dimensions
NOTE: Flue Collar size is 6 inch (152mm) diameter (ID)
4300 Millennium Pedestal Model
C
15-1/16 in. (383mm)
19-1/16 in. (484mm)
L
10-15/16 in. (271mm)
13-1/8 in. (333mm)
14-15/16 in. (373mm)
30-7/16 in.
(773mm)
9-15/16 in. (237mm)
Figure 7.1 Front View
26-5/16 in. (668mm)
10-15/16 in.
(278mm)
16 in. (406mm)
19-3/4 in. (502mm)
6-11/16 in. (170mm)
3-7/16 (87mm)
C
L
4-1/2 in
C
L
(108mm) Outside Air Connection
Figure 7.2 Side View
September 26, 2016 7037-172 7
4300 Wood Appliance Series ACC
A. Appliance Dimensions (continued)
4300 Step Top Pedestal Model
26 (660mm)
9-3/4
(248mm)
34-3/4
(883mm)
18
(457mm)
13
(330mm)
NOTE: Flue Collar size is 6 inch (152mm) diameter (ID)
4300 Step Top Q Anne Leg Model
32-7/8
(835mm)
19-1/16
(484mm)
15-1/16
(383mm)
10-15/16 (278mm)
14-15/16 (379mm)
Figure 8.1 Front View
28-11/16 (729mm)
26-5/16 (668mm)
11-1/2
(292mm)
20-3/4 (527mm)
(433mm)
15-5/8 (397mm)
16 (406mm)
21
4-1/2
(108mm) Outside Air Connection
Figure 8.3 - Front View
25-1/16
(636mm)
6-11/16
(170mm)
23-1/8 (587mm)
Figure 8.2 Side View
8 7037-172 September 26, 2016
Figure 8.4 - Side View
4300 Wood Appliance Series ACC
A. Appliance Dimensions (continued)
4300 Step Top Traditional Leg Model
33-15/16
(862)
NOTE: Flue Collar size is 6 inch (152mm) diameter (ID)
Figure 9.1 - Front View
23-7/16
(595)
Figure 9.2 - Side View
September 26, 2016 7037-172 9
25-15/16
(659)