Part 1 Performance Features
4.2”Vandalproof Pan/Tilt Dome Camera
1/3” SONY CCD + SONY DSP
540TVL
Super wide voltage board: 8-18V
High transparent vandal-proof dome cover
5-15mm F2.2 2.0MP auto focus lens
With RS485 remote control, With 128 preset points
360° Horizontal endless rotation, 90° vertical movement
A panoramic view
body rotates flexibly with less noise and
wider view shooting
Memory function at accidental power-off (Settings saved)
Technical Specifications:
Model
Image Sensor 1/3"SONY CCD
PDS-320FZA
Rev 120110
Digital Signal
Signal System PAL / NTSC
Scanning System 2:1 Interlace
Scanning
Sync. System Internal
Horizontal
Effective Pixels
(HxV)
Shuttle Speed
Mini Illumination 0.01 Lux
S/N Ratio
Gamma
SONY DSP
NTSC:15.734KHZ , PAL:15.625KHZ
540TVL
PAL:795×596
NTSC:811×508
PAL=1/50 ~1/100,000 secNTSC=1/60 ~1/100,000
sec
> 48dBAuto Gain Off
0.45
Lens
Temperature
White Balance Auto
BLC
Video Output
AGC
Power Voltage Super Wide Voltage (8V~18V)
Input Current DC12V+/_20% 50/60Hz, 1.2A above
Output Current 12V 800mA
Operating
1.3 Megapixel 5-15mm F2.2 2.0MP auto focus lens
Open
1.0V P-P,75 BNC
Auto
14°F to 122°F (-10°C to 50℃)
relative humidity: up to 95%
Built-in Decoder
1.
Full digital design, all data saved inside of the module with memory
function in case of accidental power loss.
2.
All in one integrated design, high reliability
3.
128 preset positions can be saved
4.
1-80 preset positions support auto cruise function, while 1 cruise route
can save 8 preset positions, each position pauses 6 seconds.
5.
Uses RS485 remote control interface
6.
Thanks to its expanding function, any keyboard can operate the controls
of this high speed dome.
Part 2 Functions & Operating Instructions
Storage Temp -22°F to 158°F (-30°C to 70°C)
Color
Dimensions(LXD)
Weight
Address Range 1-256
Module Index of Variable Speed Pan/Tilt/Zoom:
1. Horizontal scanning: 360°rotation
2. Horizontal speed: 0.5°—50°/s
3. The lowest speed at 0.5°/s, no vibrating images
3. Vertical scanning: >90°
4. Vertical speed: 0.5°—30°/s
5. 128 preset positions (PTZ and vari-focal lens included)
6. Speed of preset positions: 50°/s
7. PTZ scanning precision: ±0.5°
8. 3X zoom
Control Protocol:
PELCO“P”Protocol
PELCO“D”Protocol
Baud Rate
White
5x5 in (125×125mm)
2.2 lbs (1KG)without bracket and adapter
: 1200b/2400b/4800b/9600b
This part mainly describes the leading functions and common
principles of the all in one intelligent dome camera. It does not refer to t
he specific operating methods. Different systematical
platforms have different methods. In some cases, special
requirements and operating methods would exist, subject to the
product manual.
1.
1. Set CCTV encoding
The control board of the dome has a 10-DIP-switch, used to set
address, communication and control protocols PELCO-D/P (refer to “DIP switch
set”). Any command should agree with the targeted
address, and cameras only response when address code is the same.
2. CCTV Camera Operation
2.
Zoom control
User can adjust the image farther/nearer to get a panoramic view by contr
olling the keyboard buttons
oth digital and optical vari-focus. Digital vari-focus can be set.
In the following cases, the camera’s target is unable to auto
Focus:
1.
The target is not in the center of the image;
2.
When watching the farther or nearer objects, the objects are not clear;
3.
The target is a strong light, like neon light, spot light etc;
4.
The object moves to fast;
ZOOM- / ZOOM+
. The speed dome supports b
5.
Large square of monotonous object, like a wall;
6.
The object is too dark or vague;
7.
The targeted picture is too small
3.
3. Surveillance function
a)
Set & Transfer the preset points
The function of preset positions is, temporarily storing such
location parameters as horizontal angle / inclination / lens’ focus in a mem
ory and transferring them whenever they’re needed. User
can quickly transfer the preset positions via the keyboard, remote or some
thing else such as PC software. The speed dome
supports 127 preset points.
b)
Automatic Cruise
Automatic Cruise is an internal set function, which inserts the
points and sets up the automatic cruise among preset positions by program
ming them beforehand in the cruise lists. The cruise order and pausing timi
ng can be programmed and one cruise route can store 8 points and time
s.
c)
Auto Scanning
Cameras can level scan back and forth among the left & right limits at
the set speed via the keyboard and menu settings using the left and righ
t limits setup beforehand.
d)
Power-off Protection
When a planned or unplanned power-off happens, the camera
will automatically preserve the movement state before the
power-off. When the power returns, the camera will auto-recover the previ
ous stored movement.
Part 3 Extended Function
This section describes the extended function and common principles of the a
ll in one intelligent dome camera. Different systematical
platforms have different methods. In some cases, special
requirements & operational methods could exist, subject to
systematical manufacturer’s manual.
1.
1. Set the scanning
The speed dome can be set in two fixed locations and scan back and fort
h at the set speed. Set #126 for linear scanning. Set #xxx preset position,
xxx is the scanning speed (1-50 adjustable), after that, move the rod, the
image would move to the beginning locations. Set #127 as scanning
beginning location, moves the image to the ending location and set #1
28 as the ending scan location.
Example 1
Setting Method
Example 2Scan setting at the speed of 50s around.
Setting Method
2.
Transfer the cruise group
Transfer #101-102 preset point; relatively start #1-2 cruise groups. For ex
ampleStart #1 cruise group.
Method: Transfer #101 preset position.
3.
Start the linear scanning
Transfer #128 preset position.
4.
Start auto-scanning
Transfer #125 preset position or press auto-start button.
360° Auto-scanning back and forth. The speed is fixed internally.
1.
1. Clearing of fault
Scan setting at the speed of 1s around.
1.
Set #126 preset position.
2.
Set #30 as speed index.
3.
Move the rod and adjust the image as the scanning one.
4.
Set #127 as the beginning location.
5.
Move the rod and adjust the image to the scanning ending location.
6.
Set #128 as the ending location
7.
Set #126 preset position.
8.
Set #50 as speed index.
9.
Move the rod and adjust the image as the scanning one.
10.
Set #127 as the beginning location.
11.
Move the rod
12.
Set #128 as the ending location
Part 4 Appendix