Pilz P2HZ X4P Data Sheet

Two-hand Control Relays
Type IIIC, EN 574
P2HZ X4P
Technical Details P2HZ X4P
Electrical data
Supply voltage 24 V AC/DC Tolerance 85 ... 110 % Power consumption approx. 3 VA/approx. 2,5 W DC residual ripple 10 % Voltage and current at N/C contact; 24 VDC, 20 mA Input circuits 1/2 N/O contact: 24 VDC, 10 mA Switching capability in accordance with EN 60947-4-1, 10/91 AC1: 240 V/5 A/1200 VA
EN 60947-5-1, 10/91 AC15: 230 V/2.5 A; DC13: 24 V/1.5 A (DC13: 6 switching cycles/min) Output contacts 3 safety contacts (N/O),
Two-hand control relay in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98
22.5 mm width
Conforms to Type IIIC, EN 574
and category 4 in accordance with EN 954-1
Plug-in connection terminals (Either screw terminals or cage clamp terminals)
Approvals
P2HZ X4P
Contact fuse protection 6 A quick or 4 A slow to EN 60947-5-1, 10/91
Times
Delay-on de-energisation N/O: approx. 15 ms, N/C: approx. 30 ms Recovery time min. 250 ms Simultaneity channel 1/2 < 0.5 s
Mechanical Data: with cage clamp terminals
Terminal blocks per connection 2 Maximum cross section of ext. conductors Insulation length 8 mm Dimensions (H x W x D) 101 x 22,5 x 122 mm Weight 220 g
Mechanical data: with screw terminals
Max. cross section of external conductor Single-core conductor f
Multi-core conductor (2 conductors with identical cross section)
Dimensions (H x W x D) 94 x 22.5 x 122 mm Weight 220 g
DC1: 24 V/4 A/100 W
1 auxiliary contact (N/C)
Flexible, without crimp connectors: 0.2 ... 1.5 mm
lexible without crimp connector: 0.2 ... 2.5 mm
flexible with crimp connector: 0.25 ... 2.5 mm
flexible with crimp connector without plastic sleeve: 0.25 ... 1 mm flexible with TWIN crimp connector with plastic sleeve: 0.5 ... 1.5 mm
2
2
2
2
2
Description
22.5 mm S 99 housing, DIN-Rail mounting
Positive-guided relay outputs: – 3 safety contacts (N/O) – 1 auxiliary contact (N/C)
Increase in the number of safety contacts available by connecting expander modules
LED indicators for switching status, channel 1/2 and supply voltage
Function description
The two-hand control relay is used to ensure that operators keep their hands clear of the danger zone, and is suitable for use with mechanical and hydraulic presses, or in safety circuits. A cycle can only be initiated by pressing the two pushbuttons simultaneously. A cycle is interrupted by releasing one or both buttons to stop the output. The output signal can only be reinitiated after both inputs have been released and the pushbuttons operated again.
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-222-10/03
Two-hand Control Relays
Type IIIC, EN 574
P2HZ X4P
Schematic internal wiring diagram
A1
B
U
A2
Input circuits
S11
S32
Channel 1
S33
S21
Control logic
K1
Pulse diagram
1
U
B
0
1
Button 1
0
1
Button 2
0
Feedback loop
Output
1 0
1 0
t0t
t
1
2
no significance
Feedback loop open: 0 Feedback loop closed: 1
t0:UB must be applied at least 0.5 s
before button 1
Feedback loop
Y1
Y2
Safety contacts
13 23 41
33
Channel 2
K2
24
14
34
t
3
t
1
t1: Simultaneity < 0.5 s t2: Operating cycle is ended
by button 1 or 2
t3: Y1-Y2 must be closed at least 0.25 s
before the buttons are operated
Auxiliary contact
42
Increase in safety contacts The number of output contacts can be increased by using expander modules or relays/contactors with positive-guided outputs.
L+
K7
K5 K6
Y1 Y2
L-
F1
13
14
K5 K6
F2
F3
23
33
24
34
K7
– Driving a load
L+
F1
13
14
L-
F2
23
24
Connection example
P2HZ X4P 24 V DC
L+/L1
L-/N
S32
A1 Y1
A2
F4
13 Y2
S11 S21
14
23
33
41
42
S1
S33
24
34
S2
– Key
S1/S2: Two-hand pushbuttons
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-222-10/03
Loading...
+ 1 hidden pages