Pepperl Fuchs UMB800-18H40-E4-2M-FA Data Sheet

Ultrasonic sensor UMB800-18H40-E4-2M-FA
Technical data
General specifications
Sensing range 70 ... 800 mm Adjustment range 90 ... 800 mm Dead band 0 ... 70 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 170 kHz Response delay approx. 100 ms
Electrical specifications
Model Number
UMB800-18H40-E4-2M-FA
Single head system
Features
• Front of transducer and housing manufactured entirely from stainless steel
• Hygienic design, easy to clean
• Degree of protection IP68 / IP69K
• Short version: 55 mm
• Mounting bracket MH-18H-01-FA included in delivery
•Program input
• Temperature compensation
Description
Functional description
The enclosure and transducer of this ultrasonic sensor form a hermetically sealed unit. Due to its special design, this sensor is EHEDG compliant, and together with an appropriate fixture are especially suitable for applications where there are increased hygiene requirements, such as in the manufacture and handling of food. For reliable operation, due to the special design of this sensor, solely the enclosed mounting accessories must be used, even in applications without special hygiene requirements.
Operating voltage U No-load supply current I
Input
Input type 1 program input
Output
Output type 1 switching output E4, NPN, NO/NC, programmable Rated operating current I Voltage drop U Repeat accuracy ± 0.5 % of full-scale value Switching frequency f 4 Hz Range hysteresis H 1 % of the set operating distance Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 85 °C (-13 ... 185 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PUR , 2 m , Polyether based Core cross-section 4 x 0.19 mm Degree of protection IP68 / IP69K Material
Housing stainless steel 1.4404 / AISI 316L Transducer Stainless steel 1.4435 / AISI 316L Seal Cable seal : TPU , Elastollan 1185 A10 (FDA)
Mass 90 g
Factory settings
Output Switch point A1: 90 mm
General information
Supplementary information FDA: All materials used for the sensor comply with CFR, title
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
Approvals and certificates
CCC approval CCC approval / marking not required for products rated 36 V EHEDG Type EL Class I AUX ECOLAB yes
B
0
e
d
Dimensions
10 ... 30 V DC 15 mA
operating distance 1: -U ... +U
B
input impedance: > 4,7 k program pulse: 1 s
200 mA , short-circuit/overload protected 3 V
2
Switch point A2: 800 mm Output mode: Window mode Output logic: normally open
21, §177.2600 (FDA)
IEC 60947-5-2:2007 + A1:2012
... +1 V, operating d istance 2: +6 V
B
Diagrams
Characteristic response curve
Distance Y [mm]
250 200 150 100
50
0
-50
-100
-150
-200
-250 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
Y
Release date: 2016-03-01 11:55 Date of issue: 2017-03-21 274814_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
flat surface 100 mm x 100 mm
X
round bar, Ø 25 mm
Distance X [m]
11
56
16.7
18h11
1
Ultrasonic sensor UMB800-18H40-E4-2M-FA
Electrical Connection
BN
U
WH
BK
BU
+ U
B
Teach input
Switching output
- U
B
Accessories
MH-18H-01-FA
Mounting aid, 18 mm in accordance with EHEDG
Installation
Cleaning the Sensor in Areas with Hygiene Requirements
The sensor may only be used with the mounting aid included in the scope of delivery as the fixture. Please note the information in the enclosed package insert for the mounting aid with regard to the correct position of the seals and the correct process for tightening the screw connections.
If the sensor as a whole is located in an area subject to hygiene requirements, the sensor must be accessible from all sides for cleaning purposes. If the sensor is fitted with only the front in an area subject to hygiene requirements, the front must be ac­cessible from all sides accordingly.
The sensor and corresponding fixture are certified by ECOLAB. The components were subjected to the cleaning agents listed in the certificate and are resistant to the­se agents. Use of other cleaning agents and chemicals is also possible. However, to ensure the sensor and fixture offer resistance to these substances, corresponding tests must be performed by the user.
For cleaning purposes, as a general rule you can completely cover the sensor inclu­ding the fixture with foam and clean using a water jet. Cleaning at elevated tempera­tures of up to 85 °C is possible. It is not permitted to use high-pressure cleaning equipment for cleaning purposes in areas subject to hygiene requirements.
Due to the unique design of this sensor, only the mounting accessories included with the sen­sor must be used in order to ensure reliable operation, even in applications without specific hy­giene requirements.
Additional Information
Programmable output modes
1. Window mode, normally open mode A1 < A2:
A1
2. Window mode, normally closed mode A2 < A1:
A2
3. One switch point, normally open mode A1 -> ∞:
A2
4. One switch point, normally closed mode A2 -> :
A1
5. A1 -> ∞, A2 -> ∞: Object presence detection mode Object detected: Switch output closed No object detected: Switch output open
object distance
A2
A1
Adjusting the switch points
The ultrasonic sensor features a switching output with two teachable switch points. These are set by applying the supply voltage -U
or +UB to the TEACH-IN input. The
B
supply voltage must be applied to the TEACH-IN input for at least 1 s. switch point A1 is taught with -U
, A2 with +UB.
B
Five different output functions can be set
1. Window mode, normally-open function
2. Window mode, normally-closed function
3. one switch point, normally-open function
4. one switch point, normally-closed function
5. Detection of object presence
TEACH-IN window mode, normally-open function
- Set target to near switch point
- TEACH-IN switch point A1 with -U
B
- Set target to far switch point
- TEACH-IN switch point A2 with +U
B
TEACH-IN window mode, normally-closed function
- Set target to near switch point
- TEACH-IN switch point A2 with +U
B
- Set target to far switch point
- TEACH-IN switch point A1 with -U
B
TEACH-IN switch point, normally-open function
- Set target to near switch point
- TEACH-IN switch point A2 with +U
B
- Cover sensor with hand or remove all objects from sensing range
2
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Release date: 2016-03-01 11:55 Date of issue: 2017-03-21 274814_eng.xml