Ultrasonic proximity switch
3RG6342-3AB00-PF |
Compact range K0, |
|
Connector M12 |
|
|
normally open |
|
Stecker M12 |
|
|
Kompaktreihe K0, |
|
|
|
|
Schließer |
|
|
|
3RG6342-3AA00-PF |
Compact range K0, |
|
Connector M12 |
|
|
normally closed |
|
Stecker M12 |
|
|
Kompaktreihe K0, |
|
|
|
|
Öffner |
|
|
|
Size/Bauform |
|
: |
kubisch/kubisch |
|
|||
Function/Funktion |
|
: |
Diffuse/Taster |
|
|||
Operating distance/Schaltabstand |
|
|
|
|
|
|
|
Sensing range/Erfassungsbereich |
|
: |
60 ... 300 mm |
|
|||
Focusing range/Einstellbereich |
|
: |
65 |
... 300 mm |
|
||
Adjustment/Einstellung |
|
: |
Potentiometer/Potentiometer |
|
|||
Standard target/Normmessplatte |
|
: |
10 x 10 mm |
|
|||
Repeat accuracy/Wiederholgenauigkeit |
R |
: |
+/- 0,45 mm |
|
|||
Switching hysteresis/Hysterese |
H |
: |
5 mm |
|
|
|
|
Rated ultrasonic frequency/ |
|
: |
400 kHz |
|
|
||
Ultraschallnennfrequenz |
|
|
|
|
|
|
|
Power supply voltage/ |
|
|
|
|
|
|
|
Versorgungsspannung |
|
|
|
|
|
|
|
Rated operational voltage/ |
Ue |
: |
24 |
V DC |
|
|
|
Bemessungsbetriebsspannung |
|
|
|
|
|
|
|
Operating voltage range/ |
UB |
: |
10 |
... 35 V DC incl. ripple content / |
|
||
Betriebsspannungsbereich |
|
|
10 |
... 35 V DC incl. Restwelligkeit |
|
||
by reduction of operating voltage/ |
|
: |
10 |
V |
< |
operating voltage |
< 18 V/ |
bei Betriebsspannungsreduzierung |
|
|
10 |
V |
< |
Betriebsspannung |
< 18 V |
Detection/Erfassung |
|
: |
30 % < |
reduced sensitivity |
< 0 %/ |
||
|
|
|
30 % < |
reduzierte Empfindlichkeit |
< 0 % |
||
No-load supply current/Leerlaufstrom |
Io |
: |
max. 35 mA |
|
|||
max. ripple content/zul. Restwelligkeit |
|
: |
10 % |
|
|
|
Subject to modifications without notice |
Release: 08.09.2010 |
Copyright Pepperl+Fuchs |
1 |
Ultrasonic proximity switch
Output/Ausgang |
|
|
|
Output/Ausgangsart |
|
: |
pnp |
Rated operational current/ |
Ie |
: |
max. 100 mA |
Bemessungsbetriebsstrom |
|
|
|
Output voltage drop/Spannungsfall max. |
Ud |
: |
max. 2V (100mA) |
Off-state current/Reststrom |
Ir |
: |
max. 0,01 mA |
Short circuit strength/Kurzschlußfestigkeit |
|
: |
built-in/eingebaut |
Overload withstand capability/ |
|
: |
built-in/eingebaut |
Überlastfestigkeit |
|
|
|
Bidirectional connection „Release“/ |
|
|
|
Bidirektionaler Anschluß „Freigabe“ |
|
|
|
As release input/als Freigabeeingang |
|
|
|
max. input voltage/ |
|
: |
35 V |
max. Eingangsspannung |
|
|
|
max. L-Level (SONAR-BERO inactive)/ |
|
: |
0 ... 2 V |
max. L–Pegel (SONAR-BERO inaktiv) |
|
|
|
min. H-Level (SONAR-BERO active)/ |
|
: |
5 ... 35 V or high-resistance/oder hochohmig |
min. H-Level (SONAR-BERO aktiv) |
|
|
|
Input resistance (current sink)/ |
|
: |
1,5 kOhm |
Eingangswiderstand (Stromsenke) |
|
|
|
min. enable time/min. Freigabezeit |
|
: |
53 ms |
As synchronization connection/ |
|
|
|
als Synchronisieranschluß |
|
|
|
max. quantity of SONAR-BERO run in syn- |
|
: |
6 |
chronism/ |
|
|
|
max. Anzahl der synchron laufenden |
|
|
|
SONAR-BERO |
|
|
|
Times/Zeiten |
|
|
|
Frequency of operating cycles/ |
f |
: |
8 Hz |
Schaltfrequenz |
|
|
|
Time delay before availability/ |
tv |
: |
7 ms |
Bereitschaftsverzug |
|
|
|
Response time/Ansprechzeit |
|
: |
70 ms |
Temperatures/Temperaturen |
|
|
|
Rated temperature/ |
Tu |
: |
25 Cel |
Bemessungstemperatur |
|
|
|
Ambient temperature/ |
Ta |
: |
0 ... +55 Cel |
zul. Umgebungstemperatur |
|
|
|
Storage temperature range/ |
Ts |
: |
-40 ... +85 Cel |
zul. Lagertemperatur |
|
|
|
Thermal drift (teach value)/ |
|
|
|
Temperaturdrift (Toleranzwert) |
|
|
|
by heating treatment/bei Erwärmung |
|
: |
+ 0,17 % / K |
by cooling off/bei Abkühlung |
|
: |
- 0,17 % / K |
Subject to modifications without notice |
Release: 08.09.2010 |
Copyright Pepperl+Fuchs |
2 |