Inductive proximity switch
3RG4021-0AG33-PF |
NO |
Cable |
|
Schließer |
Kabel (eingegossen) |
3RG4021-7AG33-PF |
NO |
Connector M8 |
|
Schließer |
Stecker M8 |
3RG4021-0AF33-PF |
NC |
Cable |
|
Öffner |
Kabel (eingegossen) |
3RG4021-7AF33-PF |
NC |
Connector M 8 |
|
Öffner |
Stecker M 8 |
Size / Bauform |
|
cylindrical M8 / zylindrisch M8 |
|
||
|
|
|
|
|
|
Mounting / Einbau |
|
non-embeddable / nichtbündig |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Operating distance / Schaltabstand |
|
|
|
|
|
|
|
|
|
|
|
Rated operating distance / |
sn |
2,5 mm |
|
|
|
Bemessungsschaltabstand |
|
|
|
|
|
|
|
|
|
|
|
Effective operating distance / |
sr |
2,25 ... 2,75 mm |
|
|
|
Realschaltabstand |
|
|
|
|
|
Assured operating distance / |
sa |
2,03 mm |
|
|
|
Gesicherter Schaltabstand |
|
|
|
|
|
|
|
|
|
|
|
Standard target mild steel / |
|
8 x 8 x 1 mm |
|
|
|
Meßplatte Stahlfahne St 37 |
|
|
|
|
|
|
|
|
|
|
|
Repeat accuracy / Reproduzierbarkeit |
R |
0,08 mm |
|
|
|
Hysteresis / Hysterese |
H |
0,07 ... 0,50 mm |
|
|
|
|
|
|
|
|
|
Reduction factors / Reduktionsfaktoren |
|
Al: |
0,40 |
Cu: |
0,30 |
|
|
|
|
|
|
|
|
Ms: |
0,40 |
Stainl. steel / Edelst.: |
0,70 |
|
|
|
|
|
|
|
|
|
|
|
|
Power supply voltage / |
|
|
|
|
|
Versorgungsspannung |
|
|
|
|
|
Rated operational voltage / |
Ue |
24 V DC |
|
|
|
Bemessungsbetriebsspannung |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage range / |
UB |
15 ... 34 V DC |
|
|
|
Betriebsspannungsbereich |
|
|
|
|
|
|
|
|
|
||
No-load supply current / Leerlaufstrom |
lo |
17mA (24 V DC); 30mA (34 V DC) |
|
||
|
|
|
|
|
|
max. ripple content / zul. Restwelligkeit |
|
10% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output / Ausgang |
|
|
|
|
|
|
|
|
|
||
Output / Ausgangsart |
|
3 wire DC pnp / 3 Leiter DC pnp |
|
||
|
|
|
|||
Rated operational current / |
le |
200 mA (to / bis 50 Cel); 150 mA (to / bis 85 Cel) |
|||
Bemessungbetriebsstrom |
|
|
|
|
|
|
|
|
|
|
|
Output voltage drop / Spannungsfall max. |
Ud |
2,5 V |
|
|
|
|
|
|
|
|
|
Off-state current / Reststrom |
|
0,01 mA |
|
|
|
|
|
|
|
|
|
Short-circuit strength / Kurzschlußfestigkeit |
|
built-in / eingebaut |
|
|
|
|
|
|
|
|
|
Overload withstand capability / |
|
built-in / eingebaut |
|
|
|
Überlastfestigkeit |
|
|
|
|
|
|
|
|
|
|
|
Times / Zeiten |
|
|
|
|
|
|
|
|
|
|
|
Frequency of operating cycles / |
f |
900 Hz |
|
|
|
Schaltfrequenz |
|
|
|
|
|
|
|
|
|
|
|
Time delay before availability / |
tv |
40 ms |
|
|
|
Bereitschaftsverzug |
|
|
|
|
|
Subject to modifications without notice |
Release: 09.09.2010 |
Copyright Pepperl+Fuchs |
1 |