Inductive proximity switch
3RG4012-0AB00-PF |
NO / Schließer |
|
|
Cable / Kabel (eingegossen) |
|
|
|
|
|
|
|
||||||||
3RG4012-3AB00-PF |
NO / Schließer |
|
|
Connector / Stecker M12 |
|
|
|
|
|
|
|
||||||||
3RG4012-0AA00-PF |
NC / Öffner |
|
|
|
|
Cable / Kabel (eingegossen) |
|
|
|
|
|
|
|
||||||
3RG4012-3AA00-PF |
NC / Öffner |
|
|
|
|
Connector / Stecker M12 |
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Size / Bauform |
|
|
|
cylindrical M12 / zylindrisch M12 |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Mounting / Einbau |
|
|
|
embeddable / bündig |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating distance / Schaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Rated operating distance / |
|
|
sn |
2,0 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Bemessungsschaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Effective operating distance / |
|
|
sr |
1,80 ... 2,20 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|||
Realschaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Assured operating distance / |
|
|
sa |
1,62 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Gesicherter Schaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Standard target mild steel / |
|
|
|
12 x 12 x 1 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|||
Meßplatte Stahlfahne St 37 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Repeat accuracy / Reproduzierbarkeit |
|
R |
0,10 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Hysteresis / Hysterese |
|
|
H |
0,02 ... 0,44 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Reduction factors / Reduktionsfaktoren |
|
|
Al: |
0,35 |
|
Cu: |
|
0,20 |
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
Ms: |
0,40 |
|
Stainl. steel / Edelst.: |
|
0,70 |
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power supply voltage / |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Versorgungsspannung |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Rated operational voltage / |
|
|
Ue |
24 V DC |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Bemessungsbetriebsspannung |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Operating voltage range / |
|
|
UB |
10 ... 60 V DC |
|
|
|
|
|
|
|
|
|
|
|
|
|||
Betriebsspannungsbereich |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
No-load supply current / Leerlaufstrom |
|
lo |
10 mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
max. ripple content / zul. Restwelligkeit |
|
|
10% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output / Ausgang |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Output / Ausgangsart |
|
|
|
3 wire DC pnp / 3 Leiter DC pnp |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Rated operational current / |
|
|
le |
300 mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Bemessungbetriebsstrom |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Output voltage drop / Spannungsfall max. |
|
Ud |
2,5 V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Off-state current / Reststrom |
|
|
|
0,01 mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Short-circuit strength / Kurzschlußfestigkeit |
|
|
built-in / eingebaut |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Overload withstand capability / |
|
|
built-in / eingebaut |
|
|
|
|
|
|
|
|||||||||
Überlastfestigkeit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Times / Zeiten |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Frequency of operating cycles / |
|
f |
4000 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Schaltfrequenz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Time delay before availability / |
|
tv |
40 ms |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Bereitschaftsverzug |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Temperatures / Temperaturen |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Rated temperature / |
|
|
Tu |
25 Cel |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Bemessungstemperatur |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Ambient temperature range / |
|
|
Ta |
-25...+85 Cel |
|
|
|
|
|
|
|
|
|
|
|
|
|||
zul. Umgebungstemperatur |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Storage temperature range / |
|
|
Ts |
-40...+85 Cel |
|
|
|
|
|
|
|
|
|
|
|
|
|||
zul. Lagertemperatur |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Subject to modifications without notice |
|
Release: 27.09.2017 |
|
Copyright Pepperl+Fuchs |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1