Inductive proximity switch
3RG4014-0GB33-PF |
NO / Schließer |
Cable / Kabel (eingegossen) |
3RG4014-3GB33-PF |
NO / Schließer |
Connector / Stecker M12 |
3RG4014-0GA33-PF |
NC / Öffner |
Cable / Kabel (eingegossen) |
3RG4014-3GA33-PF |
NC / Öffner |
Connector / Stecker M12 |
Size / Bauform |
|
|
cylindrical M30 / zylindrisch M30 |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|||
Mounting / Einbau |
|
|
embeddable / bündig |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating distance / Schaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rated operating distance / |
|
sn |
10,0 mm |
|
|
|
|
|
|
|
|
|
|
Bemessungsschaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Effective operating distance / |
|
sr |
9,0 ... 11,0 mm |
|
|
|
|
|
|
|
|
|
|
Realschaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
Assured operating distance / |
|
sa |
8,1 mm |
|
|
|
|
|
|
|
|
|
|
Gesicherter Schaltabstand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard target mild steel / |
|
|
30 x 30 x 1 mm |
|
|
|
|
|
|
|
|
|
|
Meßplatte Stahlfahne St 37 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Repeat accuracy / Reproduzierbarkeit |
|
R |
0,3 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Hysteresis / Hysterese |
|
H |
0,05 ... 2,2 mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Reduction factors / Reduktionsfaktoren |
|
|
Al: |
0,40 |
|
Cu: |
|
0,30 |
|||||
|
|
|
|
|
|
|
|
|
|||||
|
|
|
Ms: |
0,40 |
|
Stainl. steel / Edelst.: |
|
|
0,70 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power supply voltage / |
|
|
|
|
|
|
|
|
|
|
|
|
|
Versorgungsspannung |
|
|
|
|
|
|
|
|
|
|
|
|
|
Rated operational voltage / |
|
Ue |
24 V DC |
|
|
|
|
|
|
|
|
|
|
Bemessungsbetriebsspannung |
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating voltage range / |
|
UB |
15 ... 34 V DC |
|
|
|
|
|
|
|
|
|
|
Betriebsspannungsbereich |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
No-load supply current / Leerlaufstrom |
|
lo |
17 mA (24 V DC); 30 mA (34 V DC) |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
max. ripple content / zul. Restwelligkeit |
|
|
10% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output / Ausgang |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Output / Ausgangsart |
|
|
3 wire DC npn / 3 Leiter DC npn |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|||||
Rated operational current / |
|
le |
200 mA (bis 50 Cel); 150 mA (bis 85 Cel) |
|
|
|
|
|
|||||
Bemessungbetriebsstrom |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output voltage drop / Spannungsfall max. |
|
Ud |
2,5 V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Off-state current / Reststrom |
|
|
0,01 mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Short-circuit strength / Kurzschlußfestigkeit |
|
|
built-in / eingebaut |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|||||
Overload withstand capability / |
|
|
built-in / eingebaut |
|
|
|
|
|
|||||
Überlastfestigkeit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Times / Zeiten |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency of operating cycles / |
|
f |
300 Hz |
|
|
|
|
|
|
|
|
|
|
Schaltfrequenz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Time delay before availability / |
|
tv |
40 ms |
|
|
|
|
|
|
|
|
|
|
Bereitschaftsverzug |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Temperaturen |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rated temperature / |
|
Tu |
25 Cel |
|
|
|
|
|
|
|
|
|
|
Bemessungstemperatur |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ambient temperature range / |
|
Ta |
-25...+85 Cel |
|
|
|
|
|
|
|
|
|
|
zul. Umgebungstemperatur |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Storage temperature range / |
|
Ts |
-40...+85 Cel |
|
|
|
|
|
|
|
|
|
|
zul. Lagertemperatur |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Subject to modifications without notice |
Release: 09.09.2010 |
|
Copyright Pepperl+Fuchs |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
1