Pentax W-800 series Specifications

ahead of vision
a truly integrated system
Open Platform allows you to
run major softwares such as
PowerTopoCE, SurvCE
Graphical Stakeout
results in real time on colour maps
as you measure in the fi eld
Increased Productivity swift
and easy connectivity, large
colour LCD, 640x480 pixels with
touch screen function
Pentax’s exclusive
Auto Focus system
W-800
Telescope Magnification 30 x
Optical aperture 45 mm (EDM 45 mm) Resolving power 3î Field of view 1∞ 30' (2.6%) Minimum focus 1.0 m
Focus Auto-focus + Power Focus + Manual
Phase differential
Data Processor CPU,Clock frequency Intel Xscale,400 MHz
OS MicrosoftÆ WindowsÆ CE.NET 4.2 (Pro plus version) Internal memory SDRAM = 64 MB
FLASH = 128 MB (built-in)
Interface RS-232C
USB (USB Mini-B Connector) (ver 1.0)
CF Type II Slot
SD Slot
Display 3.7 inch,Color LCD,640 x 480 pixels *(5), with back light and touch panel function
Quantity 2 1 2 1
Key board 33 keys
EDM Laser class Class (IIIa) 3R / Class (II) 2 (Selective) Class (II) 2
Distance Reflectorless 1.5 ~ 270 m N/A Measurement Mini Prism 1.5 m ~ 1100 m (1600 m) *(1) Range 1P 1.5 m ~ 3500 m (4500 m) *(2) 1.5 m ~ 3000 m (4000 m) *(2)
3P 200 m~ 4500 m (5600 m) *(2) 200 m ~ 4000 m (5000 m) *(2) Reflective sheet 1.5 m ~ 600 m (800 m) *(3)
Accuracy Prism,Reflector sheet ± (2 + 2 ppm x D) mm
Reflectorless ±(5 + 2 ppm x D) mm *(4) ± (5 + 3 ppm x D) mm *(4) N/A
Measuring time Repeat measuring Normal:Prism,Ref.sheet 2.0 sec.(1 mm) Normal:Prism,Ref.sheet 1.2 sec.(1 mm)
Track:Prism,Ref.sheet 0.4 sec. (1 cm) Quick mode*(5)
Initial measuring Normal:Reflectorless 2.3 sec.(1 mm) Normal:Prism,Ref.sheet 2.0 sec.(1 mm)
Normal:Prism,Ref.sheet 4.0 sec.(1 mm) Quick mode*(5)
Application Software Selective Memory Internal memory 128 MB
Memory Card 2 GB (Max) *(6)
Angle Method Absolute Rotary Encoder Measurement Accuracy (ISO 17123-3) 2î (0.6 mgon) 2î (1.0 mgon)
Compensator Triple Axis Dual Axis Triple Axis Dual Axis Tangent screw 2 speed 1 speed 2 speed 1 speed Calendar clock Available Plummet Visible Laser,±0.8 mm (instrument height 1.5 m) Plate level (electronic) Plate level (electronic) 30î /1div. Circular level 8í/2 mm Water resistant IP54 Ambient temperature -20∞ C ~ +50∞ C / -4∞ F ~122∞ F (Working range)
Battery Pack BP02
Ni-MH (Rechargeable)(4300 mAh) ,DC 6V Operation time Continuous Approx.3 hrs (ETH+EDM), 8 hrs (ETH) with Approx.2.2 hrs of charging time Weight Approx.380g
Charger BC03 and AC Adapter AC01 Input voltage:AC100~240 V (AC01) Output voltage:DC7.5 V (BC03) Weight:280 g Base Detachable Shifting Detachable Shifting Physical Instrument Dimension 197(W) x 347(H) x 217(L) mm (x 187(L) with 1 Display) (including Battery) Weight 6.3 kg 6.2 kg 6.3 kg 6.2 kg
*(1),*(2),*(3) :Values in ( ) are distance measurement range in good condition *(4) Over 200 to 270 m :± (7+10 ppm x D) mm *(5) Depending on application software. *(6) Memory card is not supplied with the instrument.
Model W-822NX W-823NX W-825NX W-835NX W-822EX W-823EX W-825EX W-835EX
Pentax W-800 Series Specifications
[Note]
ï The measurement range may vary by measurement conditions. ï Normal conditions:20 km visibility with slight shimmer. ï Good conditions:40 km visibility,overcast,no heat,no shimmer and moderate wind. ï Reflector sheet:PENTAX genuine reflector sheet (5 cm x 5 cm). ï Quick Mode,which is effective only under Normal mode (1mm) setting,functions with Prism and Reflector
less Sheet.It is incorporated in all X series models and effective up to 500 m.
ï When Quick Mode is on,the EDM accuracy using prism and reflector sheet is ±(3 + 2 ppm x D) mm.
When automatic correction is activated in Quick Mode,the EDM accuracy is ± (3 + 10 ppm x D) mm.
ï EDM Measuring time varies according to distance to be measured and conditions of the environment.
ï Reflector less:
- The measurement range and accuracy of Reflector less are based on the condition that laser beam is emitted perpendicular to the white side of the Kodak Gray Card.
- The measurement range may be influenced by the shape of the target and its environment.
- The measurement range at TRACK mode is over 5 m.
- It takes time,longer than usual, to measure the distance exceeding 200 m or to measure the distance to the object that is hard to measure.
- The maximum distance that can be shown on the display is 322 m in the non-prism measurement mode.
- The measurement range,accuracy of distance measurement and time required to measure may be influenced by the shape,size of surface area and reflection rate of the target and its environment.
Japan Surveying Instruments Manufacturer s’ Association
W-800 Series Technical Specifications
* Designs and specications are subject to change without notice, conguration is subject to changes per country, please contact your local dealer. - Printed in Belgium - ZAS591360 - © PENTAX 2009 - SURVEY/29/01/09
Pentax industrial instruments co. ltd
international marketing department
Tel.: +81-3-3960-0502 Fax: +81-3-3960-0509 e-mail: international@piic.pentax.co.jp www.pentax.co.jp/piic/survey
Pentax technologies europe
european headquarters
Tel.: +32 2 306 1111 Fax: +32 2 306 1199 e-mail: info_survey@pentaxtech-eu.com
Your Official Pentax Dealer
www.pentaxsurveying.com
Visit the W-800 series at:
LASER RADIATION - DO NOT STARE INTO
Laserclass IIIa, conform FDA 21 CFR
LASER RADIATION - DO NOT
CLASS II LASER PRODUCT
Laserclass II, conform FDA 21 CFR
Member symbol of the Japan Sur veying Instruments Manufacturers’ Association representing the high quality surveying products.
DANGER
BEAM OR VIEW DIRECTLY
WITH OPTICAL INSTRUMENT
INTO SUNLIGHT
620-690 nm/4.95mW max.
CLASS IIIa LASER PRODUCT
Ch. 1 § 1040
CAUTION
STARE INTO BEAM
620-690 nm/0.95mW max.
Ch. 1 § 1040