Pelco SD436-PRE0, SD436-PRE1, SD436-PRME0, SD436-PRME1, SD436-PRSE1 Quick Start Guide

...
5 (1)

ADDENDUM

Addendum No.

C2262M-A

Date

October 1, 2012

Documents Affected

C3444M-A Spectra® IV IP Series Dome System

 

Operation/Configuration manual (pp. 11 and 25)

 

C3434M-C Spectra® IV SE Horizon Series Dome Drive

 

manual (pp. 23, 68, and 69)

 

C3463M-C Spectra® IV SL and Spectra IV SE Series

 

Installation/Operation manual (pp. 1, 8, 18, 24 to 26, 30, 34, 36, 39, 41,

 

43, 46, 55, 64, and 65)

 

C3462M Spectra® IV SL and Spectra IV SE Series Dome Systems

 

Quick Start guide (pp. 1 and 10)

Document Update

This addendum describes changes to model numbers, component

 

numbers, and camera/optics specifications.

 

 

Changes to Spectra IV Model/Component Numbers

All 35X models have been replaced by 36X models. For example, SD4E35-F0 has been replaced by SD4E36-F0.

All references to TXB-IP have been replaced with TXB-N.

The following component model numbers have changed:

Obsolete 35X

Replacement 36X

Component Model Number

Component Model Number

DD4CBW35 (NTSC)

DD436 (NTSC)

 

 

DD4CBW35-X (PAL)

DD436-X (PAL)

 

 

Obsolete 27X

Replacement 29X

Component Model Number

Component Model Number

DD427 (NTSC)

DD429 (NTSC)

 

 

DD427-X (PAL)

DD429-X (PAL)

 

 

C2262M-A (9/12)

Changes to Spectra IV Product Specifications

Feature

Obsolete 35X

Replacement 36X

Specifications

Specifications

 

Lens Local Length

3.4 mm

3.3 mm

 

 

 

Zoom

35X optical

36X optical

 

 

 

Horizontal Angle of View

55.8° at 3.4 mm wide zoom

57.2° at 3.3 mm wide zoom

Feature

Obsolete 27X

Replacement 29X

Specifications

Specifications

 

Lens Focal Length

91.8 mm

98.6 mm

 

 

 

Zoom

27X optical

29X optical

 

 

 

Horizontal Angle of View

2.3° at 91.8 mm telephoto zoom

1.7° at 98.8 mm telephoto zoom

REVISIONI I

HISTORY

DO NOT COPY TEXT FROM THIS TEXT BOX - PLACEHOLDER INFO ONLY!

Document #

Date

Comments

Manual #

C2262M

5/12

.

CxxxxM

x/xx

Original version.

C2262M-A

10/12

Reformatted document size.

The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.

Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. All other product names and services are the property of their respective companies.

Product specifications and availability are subject to change without notice. © Copyright 2012, Pelco, Inc. All rights reserved.

Pelco by Schneider Electric 3500 Pelco Way Clovis, California 93612-5699 United States USA & Canada Tel (800) 289-9100 Fax (800) 289-9150

International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120 www.pelco.com www.pelco.com/community

Pelco SD436-PRE0, SD436-PRE1, SD436-PRME0, SD436-PRME1, SD436-PRSE1 Quick Start Guide

Q U I C K S T A R T

Spectra® IV SL and

Spectra IV SE Series

Dome Systems

23X, 27X, and 35X Models

C3462M (9/09)

Installing the Dome Drive

1.Perform one of the following options:

View video using both analog and IP connections: Set the DIP switches on the top of the Spectra IV dome drive (refer to Figure 12). For DIP switch settings, refer to the labels located on the top of the dome drive, or refer to Switch Settings on page 3.

View video using the IP connection: If your dome drive is part of a Spectra IV IP system, you do not need to set the DIP switches.

NOTE: When connecting more than one Spectra IV dome to a single controller, terminate the unit farthest from the controller. To terminate the dome drive set the SW2-10 switch to the ON position.

Figure 1. Setting the DIP Switches

2.Install the dome drive into the back box.

a.Align the blue and red tabs with the blue and red labels on the back box.

b.Push in the red tab and insert that side of the dome drive first.

c.Push in the blue tab and insert the dome drive into the back box the remainder of the way.

d.Continue pushing on the ends of the tabs until both sides click firmly into place.

2

C3462M (9/09)

SWITCH SETTINGS

WARNING: If you are using Pelco D-type or P-type control, your system may not operate if the baud rate and address switches are not set correctly. The switches are set at the factory at the defaults for Pelco D-type control (2400 baud and address 1).

Table A. Switch Settings for SW2

Special Systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

AD-32 Preset System

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM9502 Setting

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco Coaxitron Controller

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Third-Party Coaxial Control

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Third-Party Pelco P-type Control

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Port Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

RS422

 

 

 

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 4-Wire

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 2-Wire

 

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco D or P Protocol Baud Rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

2400 Baud (Default for D-type Control)

 

 

 

 

 

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

4800 Baud (Default for P-type Control)

 

 

 

 

 

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

9600 Baud

 

 

 

 

 

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video Cable Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Coaxial Cable

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

UTP Cable

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dome Termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Terminated

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

Not Terminated

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

C3462M (9/09)