Pelco CM6800E-48X8 User Manual

SYSTEM
CM6800E-48X8 MATRIX SWITCHER
6800
Quick Start Guide
96X16 CONFIGURATION
®
Worldwide, there’s so much we can show you.
English
Portuguese
Deutsch
Français
Italiano
Polski
CONNECTING A CM6800 96X16 SYSTEM
NOTE: If you expand a 48 x 8 system to a 96 x 16 system, you must verify that each CM6800E-48X8 unit contains the same level of switcher software. Refer to
Upgrade CM6800 Switcher Software
in the CM6800E-48X8 Matrix Switcher
Installation/Operation manual for instructions.
Step 1. Install each CM6800E-48X8 unit and connect
appropriate devices to each unit.
Refer to the CM6800E-48X8 Quick Start Guide for connection details. In a 96 x 16
®
system, keyboards, Genex
multiplexers, and other peripheral devices must be connected to the Main unit. On the Expansion unit ports 1, 3, 4, 5, 6, 7, and 8 are disabled. The Expansion unit can support cameras, monitors, local alarms, and local relays. Refer to Figure 1.
Step 2. Connect the CM6800E-48X8 Expansion unit to the
CM6800E-48X8 Main unit. Refer to Figure 2.
In the following steps, use the cables and clips provided with the CM6800E-KIT.
1. Attach the spring clips to the bay-to-bay video port on each CM6800E-48X8
unit.
2. Use the 16-channel video ribbon cable to connect the bay-to-bay video port on
the CM6800E-48X8 expansion unit to the bay-to-bay video port on the CM6800E-48X8 main unit.
3. Use the reversed data cable to connect port 2 on the CM6800E-48X8
expansion unit to port 2 on the CM6800E-48X8 main unit.
3. Select the System setting as shown:
PELCO SWITCHER
MODEL CM6800E
MAIN MENU
1 CAMERA 2 LOGICAL CAMERA 3 MONITOR 4 ACCESS 5 TIME & DATE 6 PORT 7 PRIORITY 8 SEQUENCE
9 MACRO 10 ALARM CONTACTS 11 EVENT TIMER 12 SET AUXILIARY 13 SET PASSWORD 14 SYSTEM 15 ABOUT CM6800E
ENGLISH RETURN
SYSTEM
96X16
RETURN
NOTE: The CM6800E-48X8 expansion unit must be installed within three feet of the CM6800E-48X8 main unit.
Step 3. Power-up the system and Initialize keyboards.
Refer to the CM6800E-48X8 Quick Start Guide for detailed instructions.
Step 4. Configure your system with 96 x 16 settings.
Access programming mode and select 96X16 as the System setting.
If you have not already done so, select the monitor. If the Camera menu appears on the KBD960/KBR960 LCD display, press
1. Press the PGM key (or select
PGM
to exit.
on the KBD960/KBR960). The Password
screen appears.
PELCO VIDEO SWITCHER
MODEL CM6800E
PASSWORD TO MAIN MENU
**********
SCRATCHPAD SEQUENCE
MACRO STATUS VIEW
RETURN
YOU SWITCHED TO: 96X16
IF YOU CONTINUE, SYSTEM WILL ERASE USER PROGRAMMING AND RESTORE SYSTEM SETTINGS TO FACTORY DEFAULTS!!
CONTINUE? YES
RETURN
Step 5. Configure additional system settings.
Configure the CM6800 to your specific application in Programming mode or through the CM6800-MGR. You may want to program the following basic system settings:
• Time and date
• Camera titles
• PTZ control via hard-wire data connections
• Camera control – To connect a Genex camera, as shown in Figure 1, you must change the Camera control settings. Refer to the CM6800E-48X8 Quick Start Guide for detailed instructions.
NOTE: If you have previously used the CM6800-MGR software in a 48 x 8 configuration, you must uninstall and then reinstall the software before you can use it in a 96 x 16 configuration. Refer to the CM6800-MGR Installation/Operation manual, or the CM6800-MGR online help for instructions.
MENU
and
.
NOTE: On the KBD960/KBR960 you must first select
enter the Define PIN (Default: 1234), and select
2. Enter the default password: 2899100. The Main Menu appears.
DEF
. Then
Figure 1. 96 x 16 System Connections
010101
1
2
3
4
5
6
7
8
16151413
87654847
3231302928
43 44
4321
12345678
CONTROL
AT+T
-
R
+
R
-
T+T
-
R
+
R-B
1
2
F 3
1
010101
1
2
3
4
5
6
7
8
161514131211109
8
7654321
8765484746
45
40
39
38
3736353433
3231302928272625
24
23222120191817
41 4 2 43 44
4321
ALT
120/230~ 50/60HZ 25WATTS
12345678
CONTROL
AT+T
-
R
+
R
-
T+T
-
R
+
R-B
1
2
F 3
HZ
75
1
010101
1
2
3
4
5
6
7
8
161514131211109
8
7654321
8765484746
45
40
39
38
3736353433
3231302928272625
24
23222120191817
41 4 2 43 44
4321
ALT
120/230~ 50/60HZ 25WATTS
123456 78
CONTROL
AT+T
-
R
+
R
-
T+T
-
R
+
R-B
1
2
F 3
HZ
75
1
English
CAMERA 1
CM6800E-48X8 MAIN UNIT
HZ
75
3736353433
CAMCLOSURE
GENEX MULTIPLEXER
CAMERA 48
8
7654321
24
23222120191817
40
38
39
MONITOR 1
MONITOR 1
MONITOR 1
41 4 2 43 44
45
ALT
ALARM 1
MONITOR 8
SPOT
SPOT
MAIN
MAIN
VCR
VCR
MONITOR 8
MONITOR 8
OUT IN
OUT IN
AUX
AUX
SVHS
SVHS
SVHS
SVHS
ALARM 8
161514131211109
3231302928272625
4321
8765484746
IN COM OUT
IN COM OUT
ALARMS
ALARMS
12345678 91011 1415161213
12345678 91011 1415161213
NNH
NNH OCCS
OCCS
VIDEO TO
SWITCHER
CAMERA 96
ALARM 9 ALARM 16
VIDEO TO
SWITCHER
CAMERA 49
123456 78
AT+T
-
1
1
PTZ CONTROL
CONTROL
R
R-B
T+T
R
R
-
-
+
+
F 3
2
120/230~ 50/60HZ
25WATTS
C D
PTZ CONTROL
010101
12345678
5
1
2
3
4
CONTROL
6
AT+T
-
7
8
1
1
A
R
R-B
T+T
R
R
-
-
+
+
F
B
3
2
120/230~ 50/60HZ 25WATTS
CM6800E-48X8 EXPANSION UNIT
HZ
75
7654321
23222120191817
38
39
3736353433
8
24
41 4 2 43 44
45
40
010101
161514131211109
5
1
6
2
3231302928272625
7
3
8
4
4321
8765484746
ALT
PC
MONITOR 16
110-240V50/60 Hz
110-240V50/60 Hz
MONITOR 9
PORTS 9 & 10 AUX RELAYS 1-3 PORTS 11 & 12 AUX RELAYS 4-6
A
B
C
(PTZ-A & PTZ-B) (PTZ-C & PTZ-D)
Figure 2. Data and Video Connections Between CM6800E-48X8 Units
CM6800E-48X8 MAIN UNIT CM6800E-48X8 EXPANSION UNIT
010101
010101
12345678
16151413
16151413
1
1
2
2
3231302928
3231302928
3
3
4
4
4321
44
44
4321
87654847
87654847
12345678
5
5
6
6
7
7
8
8
CONTROL
CONTROL
R
R-B
R
AT+T
AT+T
-
-
1
1
1
1
R-B
T+T
T+T
R
R
R
R
-
-
-
-
+
+
+
+
F
F 3
3
2
2
120/230~ 50/60 HZ
25 WATTS
43 44
D
010101
16151413
1
2
3231302928
3
4
4321
87654847
12345678
5
6
7
8
CONTROL
R
AT+T
-
1
1
R-B
T+T
R
R
-
-
+
+
F 3
2
120/230~ 50/60 HZ
25 WATTS
!
CONEXIÓN DEL SISTEMA CM6800 96X16
NOTA: Si expande un sistema de 48 x 8 a uno de 96 x 16, debe verificar que cada unidad CM6800E-48X8 contenga el mismo nivel de software de conmutación. Encontrará instrucciones específicas en la sección
software de conmutación CM6800
del Manual de instalación y funcionamiento
Actualización de
del conmutador de matriz CM6800E-48x8.
Paso 1. Instalar cada unidad CM6800E-48X8 y conectar los
dispositivos adecuados a cada unidad.
Consulte la Guía para Inicio Rápido de Operación para CM6800E-48X8 para obtener los detalles de conexión. En un sistema 96 x 16, los teclados, los
®
multiplexores Genex
y otros dispositivos periféricos deben estar conectados a la Unidad principal. En la Unidad de expansión los puertos 1, 3, 4, 5, 6, 7 y 8 están desactivados. La Unidad de expansión es compatible con cámaras, monitores, alarmas locales y relés locales. Consulte la Figura 1.
Paso 2. Conectar la Unidad de expansión CM6800E-48X8 a
la Unidad principal CM6800E-48X8. Consulte la Figura 2.
En los pasos siguientes, use los cables y abrazaderas suministrados con el CM6800E-KIT.
1. Ajuste los clips de resorte al puerto de video de compartimiento a
compartimiento en cada unidad CM6800E-48X48.
2. Use el cable de cinta de video de 16 canales para conectar el Puerto de video
de compartimiento a compartimiento de la unidad de expansión CM6800E-48X8 al Puerto de video compartimiento a compartimiento de la unidad principal CM6800E-48X8.
3. Use el cable de datos inverso para conectar el Puerto 2 de la unidad de
expansión CM6800E-48X8 con el Puerto 2 de la unidad principal CM6800E-48X8.
3. Seleccione la configuración del sistema de la siguiente manera:
SECUENCIADOR PELCO
MODELO CM6800E
MENÚ PRINCIPAL
1 CÁMERA 2 CÁMERA LÓGICA 3 MONITOR 4 ACCESSO 5 HORA Y FECHA 6 PUERTO 7 PRIORIDAD 8 SECUENCIA
9 MACRO 10 CONTACTOS DE ALARMA 11 RELOJ DE EVENTOS 12 AJUSTE AUXILIAR 13 AJUSTE CONTRASEÑA 14 SISTEMA 15 SOBRE CM6800E
ESPAÑOL
REGRESAR
SISTEMA
96X16
REGRESAR
CAMBIÓ A: 96X16
¡¡SI CONTINÚA, EL SISTEMA BORRARÁ LA PROGRAM. DE USUARIO Y RESTAURARÁ LA CONFIG. DE SISTEMA PREDET DE FABRICA!!
¿DESEA CONTINUAR? SÍ
REGRESAR
NOTA: La unidad de expansión CM6800E-48X8 debe estar instalada a una distancia no mayor que tres pies de la unidad principal CM6800E-48X8.
Paso 3. Energizar el sistema e inicializar los teclados.
Consultar la Guía para Inicio Rápido de Operación para CM6800E-48X8 para obtener instrucciones detalladas.
Paso 4. Configurar su sistema con la configuración 96 x 16.
Entre al modo de programación y seleccione 96X16 como configuración del sistema.
Si todavía no lo hizo, seleccione el monitor. Si aparece el menú Cámara en la pantalla KBD960/KBR960 LCD, presione
1. Presione la tecla PGM (o seleccione
para salir.
PGM
en KBD960/KBR960). Aparece la
pantalla Contraseña.
SECUENCIADOR DE VÍDEO PELCO
MODELO CM6800E
CONTRASEÑA PARA MENÚ PRINCIPAL
**********
SECUENCIA DE TRABAJO
ESTADO MACRO VISTA
REGRESAR
DEF
y
NOTA: En el KBD960/KBR960 primero debe seleccionar Después introduzca el PIN definido (por defecto: 1234), y seleccione
.
MENU
.
Paso 5. Ajustar las configuraciones adicionales del sistema.
Configure el CM6800 según su aplicación específica en modo PROGRAMACIÓN o a través de CM6800-MGR. Es posible que deba ajustar las siguientes configuraciones básicas del sistema:
• Hora y fecha
• Títulos de cámara
• Control PTZ vía cable de conexión de datos
• Control de cámara: Para conectar una cámara Genex, como se muestra en la Figura 1, debe cambiar la configuración de control de cámara. Consulte la Guía para Inicio Rápido de Operación para CM6800E-48X8 para obtener instrucciones detalladas.
NOTA: Si ha utilizado previamente el software CM68000-MGR en una configuración 48 x 8, debe desinstalar y volver a reinstalar el software antes de poder utilizarlo en una configuración de 96 x 16. Encontrará instrucciones en el Manual de instalación y funcionamiento del CM6800-MGR o en la ayuda en línea del CM6800-MGR.
2. Introduzca la contraseña por defecto: 2899100. Aparecerá el Menú Principal.
Loading...
+ 14 hidden pages