Worldwide, there’s so much we can show you.
CONNECTING A CM6800 96X16 SYSTEM
NOTE: If you expand a 48 x 8 system to a 96 x 16 system, you must verify that
each CM6800E-48X8 unit contains the same level of switcher software. Refer to
Upgrade CM6800 Switcher Software
in the CM6800E-48X8 Matrix Switcher
Installation/Operation manual for instructions.
Step 1. Install each CM6800E-48X8 unit and connect
appropriate devices to each unit.
Refer to the CM6800E-48X8 Quick Start Guide for connection details. In a 96 x 16
®
system, keyboards, Genex
multiplexers, and other peripheral devices must be
connected to the Main unit. On the Expansion unit ports 1, 3, 4, 5, 6, 7, and 8 are
disabled. The Expansion unit can support cameras, monitors, local alarms, and
local relays. Refer to Figure 1.
Step 2. Connect the CM6800E-48X8 Expansion unit to the
CM6800E-48X8 Main unit. Refer to Figure 2.
In the following steps, use the cables and clips provided with the CM6800E-KIT.
1. Attach the spring clips to the bay-to-bay video port on each CM6800E-48X8
unit.
2. Use the 16-channel video ribbon cable to connect the bay-to-bay video port on
the CM6800E-48X8 expansion unit to the bay-to-bay video port on the
CM6800E-48X8 main unit.
3. Use the reversed data cable to connect port 2 on the CM6800E-48X8
expansion unit to port 2 on the CM6800E-48X8 main unit.
3. Select the System setting as shown:
PELCO SWITCHER
MODEL CM6800E
MAIN MENU
1 CAMERA
2 LOGICAL CAMERA
3 MONITOR
4 ACCESS
5 TIME & DATE
6 PORT
7 PRIORITY
8 SEQUENCE
9 MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 SYSTEM
15 ABOUT CM6800E
ENGLISH
RETURN
➠
SYSTEM
96X16
RETURN
➠
NOTE: The CM6800E-48X8 expansion unit must be installed within three feet of
the CM6800E-48X8 main unit.
Step 3. Power-up the system and Initialize keyboards.
Refer to the CM6800E-48X8 Quick Start Guide for detailed instructions.
Step 4. Configure your system with 96 x 16 settings.
Access programming mode and select 96X16 as the System setting.
If you have not already done so, select the monitor. If the Camera menu appears
on the KBD960/KBR960 LCD display, press
1. Press the PGM key (or select
PGM
to exit.
on the KBD960/KBR960). The Password
screen appears.
PELCO VIDEO SWITCHER
MODEL CM6800E
PASSWORD TO MAIN MENU
**********
SCRATCHPAD SEQUENCE
MACRO STATUS VIEW
RETURN
YOU SWITCHED TO: 96X16
IF YOU CONTINUE, SYSTEM WILL
ERASE USER PROGRAMMING AND
RESTORE SYSTEM SETTINGS TO
FACTORY DEFAULTS!!
CONTINUE? YES
RETURN
Step 5. Configure additional system settings.
Configure the CM6800 to your specific application in Programming mode or through
the CM6800-MGR. You may want to program the following basic system settings:
• Time and date
• Camera titles
• PTZ control via hard-wire data connections
• Camera control – To connect a Genex camera, as shown in Figure 1, you must
change the Camera control settings. Refer to the CM6800E-48X8 Quick Start
Guide for detailed instructions.
NOTE: If you have previously used the CM6800-MGR software in a 48 x 8
configuration, you must uninstall and then reinstall the software before you can
use it in a 96 x 16 configuration. Refer to the CM6800-MGR Installation/Operation
manual, or the CM6800-MGR online help for instructions.
MENU
and
.
NOTE: On the KBD960/KBR960 you must first select
enter the Define PIN (Default: 1234), and select
2. Enter the default password: 2899100. The Main Menu appears.
DEF
. Then
Figure 1. 96 x 16 System Connections
010101
1
2
3
4
5
6
7
8
16151413
87654847
3231302928
43 44
4321
12345678
CONTROL
AT+T
-
R
+
R
-
T+T
-
R
+
R-B
1
2
F
3
1
010101
1
2
3
4
5
6
7
8
161514131211109
8
7654321
8765484746
45
40
39
38
3736353433
3231302928272625
24
23222120191817
41 4 2 43 44
4321
ALT
120/230~
50/60HZ
25WATTS
12345678
CONTROL
AT+T
-
R
+
R
-
T+T
-
R
+
R-B
1
2
F
3
HZ
75
1
010101
1
2
3
4
5
6
7
8
161514131211109
8
7654321
8765484746
45
40
39
38
3736353433
3231302928272625
24
23222120191817
41 4 2 43 44
4321
ALT
120/230~
50/60HZ
25WATTS
123456 78
CONTROL
AT+T
-
R
+
R
-
T+T
-
R
+
R-B
1
2
F
3
HZ
75
1
English
CAMERA 1
CM6800E-48X8 MAIN UNIT
HZ
75
3736353433
CAMCLOSURE
GENEX MULTIPLEXER
CAMERA 48
8
7654321
24
23222120191817
40
38
39
MONITOR 1
MONITOR 1
MONITOR 1
41 4 2 43 44
45
ALT
ALARM 1
MONITOR 8
SPOT
SPOT
MAIN
MAIN
VCR
VCR
MONITOR 8
MONITOR 8
OUT IN
OUT IN
AUX
AUX
SVHS
SVHS
SVHS
SVHS
ALARM 8
161514131211109
3231302928272625
4321
8765484746
IN COM OUT
IN COM OUT
ALARMS
ALARMS
12345678 91011 1415161213
12345678 91011 1415161213
NNH
NNH
OCCS
OCCS
VIDEO TO
SWITCHER
CAMERA 96
ALARM 9 ALARM 16
VIDEO TO
SWITCHER
CAMERA 49
123456 78
AT+T
-
1
1
PTZ CONTROL
CONTROL
R
R-B
T+T
R
R
-
-
+
+
F
3
2
120/230~
50/60HZ
25WATTS
C
D
PTZ CONTROL
010101
12345678
5
1
2
3
4
CONTROL
6
AT+T
-
7
8
1
1
A
R
R-B
T+T
R
R
-
-
+
+
F
B
3
2
120/230~
50/60HZ
25WATTS
CM6800E-48X8 EXPANSION UNIT
HZ
75
7654321
23222120191817
38
39
3736353433
8
24
41 4 2 43 44
45
40
010101
161514131211109
5
1
6
2
3231302928272625
7
3
8
4
4321
8765484746
ALT
PC
MONITOR 16
110-240V50/60 Hz
110-240V50/60 Hz
MONITOR 9
PORTS 9 & 10 AUX RELAYS 1-3 PORTS 11 & 12 AUX RELAYS 4-6
A
B
C
(PTZ-A & PTZ-B) (PTZ-C & PTZ-D)
Figure 2. Data and Video Connections Between CM6800E-48X8 Units
CM6800E-48X8 MAIN UNIT CM6800E-48X8 EXPANSION UNIT
010101
010101
12345678
16151413
16151413
1
1
2
2
3231302928
3231302928
3
3
4
4
4321
44
44
4321
87654847
87654847
12345678
5
5
6
6
7
7
8
8
CONTROL
CONTROL
R
R-B
R
AT+T
AT+T
-
-
1
1
1
1
R-B
T+T
T+T
R
R
R
R
-
-
-
-
+
+
+
+
F
F
3
3
2
2
120/230~
50/60 HZ
25 WATTS
43 44
D
010101
16151413
1
2
3231302928
3
4
4321
87654847
12345678
5
6
7
8
CONTROL
R
AT+T
-
1
1
R-B
T+T
R
R
-
-
+
+
F
3
2
120/230~
50/60 HZ
25 WATTS
!
CONEXIÓN DEL SISTEMA CM6800 96X16
NOTA: Si expande un sistema de 48 x 8 a uno de 96 x 16, debe verificar que
cada unidad CM6800E-48X8 contenga el mismo nivel de software de
conmutación. Encontrará instrucciones específicas en la sección
software de conmutación CM6800
del Manual de instalación y funcionamiento
Actualización de
del conmutador de matriz CM6800E-48x8.
Paso 1. Instalar cada unidad CM6800E-48X8 y conectar los
dispositivos adecuados a cada unidad.
Consulte la Guía para Inicio Rápido de Operación para CM6800E-48X8 para
obtener los detalles de conexión. En un sistema 96 x 16, los teclados, los
®
multiplexores Genex
y otros dispositivos periféricos deben estar conectados a la
Unidad principal. En la Unidad de expansión los puertos 1, 3, 4, 5, 6, 7 y 8 están
desactivados. La Unidad de expansión es compatible con cámaras, monitores,
alarmas locales y relés locales. Consulte la Figura 1.
Paso 2. Conectar la Unidad de expansión CM6800E-48X8 a
la Unidad principal CM6800E-48X8. Consulte la
Figura 2.
En los pasos siguientes, use los cables y abrazaderas suministrados con el
CM6800E-KIT.
1. Ajuste los clips de resorte al puerto de video de compartimiento a
compartimiento en cada unidad CM6800E-48X48.
2. Use el cable de cinta de video de 16 canales para conectar el Puerto de video
de compartimiento a compartimiento de la unidad de expansión CM6800E-48X8
al Puerto de video compartimiento a compartimiento de la unidad principal
CM6800E-48X8.
3. Use el cable de datos inverso para conectar el Puerto 2 de la unidad de
expansión CM6800E-48X8 con el Puerto 2 de la unidad principal CM6800E-48X8.
3. Seleccione la configuración del sistema de la siguiente manera:
SECUENCIADOR PELCO
MODELO CM6800E
MENÚ PRINCIPAL
1 CÁMERA
2 CÁMERA LÓGICA
3 MONITOR
4 ACCESSO
5 HORA Y FECHA
6 PUERTO
7 PRIORIDAD
8 SECUENCIA
9 MACRO
10 CONTACTOS DE ALARMA
11 RELOJ DE EVENTOS
12 AJUSTE AUXILIAR
13 AJUSTE CONTRASEÑA
14 SISTEMA
15 SOBRE CM6800E
ESPAÑOL
REGRESAR
➠
SISTEMA
96X16
REGRESAR
➠
CAMBIÓ A: 96X16
¡¡SI CONTINÚA, EL SISTEMA BORRARÁ
LA PROGRAM. DE USUARIO Y
RESTAURARÁ LA CONFIG. DE SISTEMA
PREDET DE FABRICA!!
¿DESEA CONTINUAR? SÍ
REGRESAR
NOTA: La unidad de expansión CM6800E-48X8 debe estar instalada a una
distancia no mayor que tres pies de la unidad principal CM6800E-48X8.
Paso 3. Energizar el sistema e inicializar los teclados.
Consultar la Guía para Inicio Rápido de Operación para CM6800E-48X8 para
obtener instrucciones detalladas.
Paso 4. Configurar su sistema con la configuración 96 x 16.
Entre al modo de programación y seleccione 96X16 como configuración del sistema.
Si todavía no lo hizo, seleccione el monitor. Si aparece el menú Cámara en la
pantalla KBD960/KBR960 LCD, presione
1. Presione la tecla PGM (o seleccione
para salir.
PGM
en KBD960/KBR960). Aparece la
pantalla Contraseña.
SECUENCIADOR DE VÍDEO PELCO
MODELO CM6800E
CONTRASEÑA PARA MENÚ PRINCIPAL
**********
SECUENCIA DE TRABAJO
ESTADO MACRO VISTA
REGRESAR
DEF
y
NOTA: En el KBD960/KBR960 primero debe seleccionar
Después introduzca el PIN definido (por defecto: 1234), y seleccione
.
MENU
.
Paso 5. Ajustar las configuraciones adicionales del
sistema.
Configure el CM6800 según su aplicación específica en modo PROGRAMACIÓN o
a través de CM6800-MGR. Es posible que deba ajustar las siguientes
configuraciones básicas del sistema:
• Hora y fecha
• Títulos de cámara
• Control PTZ vía cable de conexión de datos
• Control de cámara: Para conectar una cámara Genex, como se muestra en la
Figura 1, debe cambiar la configuración de control de cámara. Consulte la
Guía para Inicio Rápido de Operación para CM6800E-48X8 para obtener
instrucciones detalladas.
NOTA: Si ha utilizado previamente el software CM68000-MGR en una
configuración 48 x 8, debe desinstalar y volver a reinstalar el software antes de
poder utilizarlo en una configuración de 96 x 16. Encontrará instrucciones en el
Manual de instalación y funcionamiento del CM6800-MGR o en la ayuda en línea
del CM6800-MGR.
2. Introduzca la contraseña por defecto: 2899100. Aparecerá el Menú Principal.