Panasonic ST1-DC3V-F, ST1-L2-DC5V-F, ST1-L2-DC3V-F, ST1-DC5V-F, ST1-DC6V-F Instruction Manual

...
ST
ORDERING INFORMATION
IC DRIVABLE PC BOARD
RELAY FOR INDUCTIVE
LOAD SWITCHING
ST RELAYS
VDE
1. Even with small form factor, sensitive enough for direct IC-driving
The dimensions of this high-density 4­gap balanced armature are 31 mm × 14 mm × 11 mm 1.220 inch × .551 inch ×
.433 inch. Despite this small size, high
sensitivity is achieved by a mechanism that incorporates high-efficiency polarized magnetic circuits along with our exclusive spring alignment method. With an minimum operating power of about 150 mW, nominal operating power of 240 mW, this relay can be directly driven by transistor or chip controllers.
RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/
2. High switching capability
High contact pressure, low contact bounce, and forced separation structure that radically improves resistance to contact welding (1 Form A 1 Form B type equivalent to TV-3). Strong against lamp inductive loads, maximum switching capacity has reached 3,040 VA (8A 380V AC).
3. High breakdown voltage – Optimal for control in 250 V power circuits
High breakdown voltage has been achieved. Between contacts and coil of 3,750 Vrms; Surge breakdown voltage between coil and contact of 6,000 V, and between open contacts of 1,200 Vrms mean that these relays are suitable even for 250 V power circuit control.
4. Improved stability Conforms to all types of safety standards.
Insulating distance of more than 3 mm secured. Complies with Japan Electrical Appliance and Material Safety Law requirements for operating 200 V power supply circuits, and conforms with UL, CSA and VDE standards.
5. Latching types available
In addition to single side stable types, convenient 2 coil latching types with memory functions are also available. Moreover, we offer 2 Form A specifications which, with double pole switching for applications such as 250 V power circuit switching, can enable safer designs.
6. Automatic cleaning possible
The sealed design means that these relays can undergo immersion in automatic washing systems and are suitable for automatic soldering. Even in difficult environments, the contacts remain reliable.
7. Easy to design PC board patterns
Features 4/10 dual-in-line terminals. Because the lead spacing has a pitch greater than 7.54 mm .297 inch, designers can make easy adjustments with the width of the land size. This, along with the large insulation distance, simplifies the drawing of PC board patterns.
8. To improve soldering efficiency, preapplication of solder to the terminals is recommended.
About Cd-free contacts
We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix “F” should be added to the part number) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load.
Contact material F: AgSnO2 type contact
Coil voltage DC 3, 5, 6, 9, 12, 24, 48 V
Contact arrangement 1: 1 Form A 1 Form B 2: 2 Form A
ST F
Operating function Nil: L2:
Single side stable 2 coil latching
Note: UL/CSA, VDE, SEV type is standard.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
ST
TYPES
Standard packing: Tube: 50 pcs.; Case: 500 pcs.
RATING
1. Coil data
1) Single side stable
2) 2 coil latching
Contact arrangement Nominal coil voltage
Single side stable 2 coil latching
Part No. Part No.
1 Form A 1 Form B
3V DC ST1-DC3V-F ST1-L2-DC3V-F 5V DC ST1-DC5V-F ST1-L2-DC5V-F 6V DC ST1-DC6V-F ST1-L2-DC6V-F
9V DC ST1-DC9V-F ST1-L2-DC9V-F 12V DC ST1-DC12V-F ST1-L2-DC12V-F 24V DC ST1-DC24V-F ST1-L2-DC24V-F 48V DC ST1-DC48V-F ST1-L2-DC48V-F
2 Form A
3V DC ST2-DC3V-F ST2-L2-DC3V-F
5V DC ST2-DC5V-F ST2-L2-DC5V-F
6V DC ST2-DC6V-F ST2-L2-DC6V-F
9V DC ST2-DC9V-F ST2-L2-DC9V-F 12V DC ST2-DC12V-F ST2-L2-DC12V-F 24V DC ST2-DC24V-F ST2-L2-DC24V-F 48V DC ST2-DC48V-F ST2-L2-DC48V-F
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. allowable voltage
(at 20°C 68°F)
3V DC
80%V or less of nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
75mA 38
240mW
150%V of
nominal voltage
5V DC 47mA 105 6V DC 40mA 150
9V DC 25mA 360 12V DC 20mA 600 24V DC 10mA 2,400 48V DC 4.7mA 9,000
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. allowable voltage
(at 20°C 68°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
3V DC
80%V or less of nominal voltage
(Initial)
80%V or less of nominal voltage
(Initial)
75mA 75mA 40 40
240mW 240mW
150%V of
nominal voltage
5V DC 45mA 45mA 110 110
6V DC 37.5mA 37.5mA 155 155
9V DC 25mA 25mA 360 360 12V DC 18.8mA 18.8mA 640 640 24V DC 10mA 10mA 2,400 2,400 48V DC 4.7mA 4.7mA 10,200 10,200
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.