1. Be careful during removing metal parts, sharp edges.
2. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
3. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers shields are properly
installed.
4. After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
1.1.1. LEAKAGE CURRENT COLD
CHECK
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screw heads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1MΩ and 5.2MΩ.
When the exposed metal does not have a return path to
the chassis, the reading must be infinity.
1.1.2. LEAKAGE CURRENT HOT CHECK
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5kΩ, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the ACplugintheACoutlet and repeateach of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliampere. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
2.1. PREVENTION OF ELECTROSTATIC DISCHARGE (ESD) TO
ELECTROSTATIC SENSITIVE (ES) DEVICES
Some semiconductor (solid state) devices can be damaged
easily by static electricity. Such components commonly are
called Electrostatic Sensitive (ES) Devices. Examples of typical
ES devices are integrated circuits and some field-effect
transistor-sandsemiconductor"chip"components.The
following techniques should be used to help reduce the
incidence of component damage caused by electrostatic
discharge (ESD).
1. Immediatelybeforehandlinganysemiconductor
component or semiconductor-equipped assembly, drain off
any ESD on your body by touching a known earth ground.
Alternatively, obtain and wear a commercially available
discharging ESD wrist strap, which should be removed for
potential shock reasons prior to applying power to the unit
under test.
2. After removing an electrical assembly equipped with ES
devices, place the assembly on a conductive surface such
as aluminum foil, to prevent electrostatic charge buildup or
exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder
ES devices.
4. Use only an anti-static solder removal device. Some solder
removal devices not classified as "anti-static (ESD
protected)" can generate electrical charge sufficient
to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate
electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective
package until immediately before you are ready to install it.
(Most replacement ES devices are packaged with leads
electrically shorted together by conductive foam, aluminum
foil or comparable conductive material).
7. Immediately before removing the protective material from
the leads of a replacement ES device, touch the protective
material to the chassis or circuit assembly into which the
device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and
observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged
replacement ES devices. (Otherwise hamless motion such
as the brushing together of your clothes fabric or the lifting
of your foot from a carpeted floor can generate static
electricity sufficient to damage an ES device).
This product utilizes a laser diode with the unit turned “on”,
invisible laser radiation is emitted from the pickup lens.
Wave length: 662 nm (DVDs)/780 nm (CDs)
Maximum output radiation power from pickup: 100µ W/VDE.
Laser radiation from the pickup lens is safety level, but be sure
the followings:
1. Do not disassemble the optical pickup unit, since radiation
from exposed laser diode is dangerous.
2. Do not adjust the variable resistor on the pickup unit.
It was already adjusted.
3. Do not look at the focus lens using optical instruments.3. Nicht in die Fokussierlinse blicken.
4. Recommend not to look at pickup lens for a long time.4. Auch nicht mit optischen Instrumenten in die Fokussierlinse blicken.
Dieses Produkt enthält eine Laserdiode.
Im eingeschalteten Zustand wird unsichtbare Laserstrahlung von der
Lasereinheit ausgestrahlt.
Wellenlänge: 662 nm(DVDs)/780 nm (CDs)
Maximale Strahlungsleistung der Lasereinheit: 100µ W/VDE.
Die Strahlung der eingeschalteten Lasereinheit ist ungefährlich, wenn
folgende Punkte beachtet werden:
1. Die Lasereinheit nicht zerlegen, da die Strahlung an der freigelegten
Laserdiode gefährlich ist.
2. Den werksseitig justierten Einstellregler der Lasereinheit nicht
verstellen.
· The lead free solder has been used in the mounting process of all electrical components on the printed circuit boards used
for this equipment in considering the globally environmental conservation.
· The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists
of tin (Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30 degrees C (86°F)
more than that of the normal solder.
Service caution for repair work using Lead Free Solder (PbF)
·The lead free solder has to be used when repairing the equipment for which the lead free solder is used.
·To put lead free solder, it should be well molten and mixed with the original lead free solder.
·Remove the remaining lead free solder on the PCB cleanly for soldering of the new IC.
·Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt
the lead free solder.
· Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature
at 350±30 degrees C (662±86°F). When soldering or unsoldering, please completely remove all of the solder
on the pins or solder area and be sure to heat the soldering points with the Pb free solder until it melts enough.
Definition of PCB Lead Free Solder being used
·The letter of “Pbf is printed either foil side or component side using the lead free solder.
Recommended Lead Free Solder (Service Parts Route.)
· The following 3 types of lead free solder are available through the service parts route.
RFKZ03D01K-----------(0.3mm 100g Reel)
RFKZ06D01K-----------(0.6mm 100g Reel)
RFKZ10D01K-----------(1.0mm 100g Reel)
Note
· Ingredient: tin (Sn), 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%
This service manual contains technical which will alow service personnel’s to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, this information will be followed by supplement service manual to be filed with
original service manual.
1. This service manual does not contain the following information, because of the impossibility of sevicing at component level.
·Schematic Diagram, Block Diagram and P.C.B. layout of RAM/Digital P.C.B. Module and Back End P.C.B. Unit.
·Parts List for individual parts of RAM/Digital P.C.B. Module.
·Exploded View and Parts List for individual parts of RAM/Digital P.C.B. Module.
2. The following category are recycle module part. Please send them to Central Repair Center.
·RAM/Digital P.C.B. Module: RFKNEX75EG
·RAM/Digital P.C.B. Module: RFKNEX75EC
·RAM/Digital P.C.B. Module: RFKNEX75EB
·RAM/Digital P.C.B. Module: RFKNEX85EG
·RAM/Digital P.C.B. Module: RFKNEX85EB
·Back End P.C.B. Unit: REPD00311A (EX75EG/EX85EG)
·Back End P.C.B. Unit: REPD00311C (EX75EB/EX85EB)
·Back End P.C.B. Unit: REPD00311D (EX75EC)
3.2. CAUTION FOR DivX
Please give the information “Warning for Customers who use the DivX Video-on-Demand content.” always to the customer
together with the product, if you have to exchange EEPROM, P.C.B. including EEPROM or the product itself.
Also attach these information to every service part (EEPROM or P.C.B. including EEPROM).
This complete Information is needed for every customer who is using the DivX Video-on-Demand Serivce.
Appendix:
* Parts that memorize user’s information are only on the EEPROM.
* The registration of Registration Code is possible for half a year up to 6 recorders up to 10 recorders a year.
Every replacement of EEPROM or P.C.B. including EEPROM spends one of this.
·Registration Code is memorized in the EEPROM (RFKFxxxxxxx)
·If the Power & Digital I/F P.C.B. or the EEPROM will be changed a new Registration Code
different from the previous one will be generated.
· In this case the customer, who is useing DivX Video-on-Demand sercive, can not longer play any content that
was or is purchased under that old registration code.
· Therefore the customer will need to register a new registration code.
DivX is a new video compressing format that is applied
MPEG-4 technology to improve quality and the compressibility
and it is developed by the DivXNetworks, Inc., Video file of high
resolution and the high picture quality can be made thought it
is a high compressibility.
DivX codec is necessary for converting video to DivX file and
playback files made.
5.1.2. OPERATING INSTRUCTIONS
ABOUT DivX VIDEO-ON-DEMAND
CONTENT
DivX Video-on-Demand (VOD) content is encrypted for
copyright protection. In order to play DivX VOD content on this
unit, you first need to register the unit.
Follow the online instructions for purchasing DivX VOD content
to enter unit’s registration code and register unit. Visit
www.divx.com/vod for mor information.
Display unit’s registration code:
When playing this content
·Number of remaining plays is reduced by one if
− you press [POWER]
− you press [STOP]
− you press [backwards SKIP],
[backwards SLOW / SEARCH] or
[forwards SLOW / SEARCH]
etc. and arrive at another content or start of content
being played.
− scheduled [DRIVE SELECT] to change drive
* Resume functions do not work.
Typical Playback procedure of DivX VOD
(Video On Demand):
Case 1
Case 2
Case 3
Case 4
Case 5
When DivX VOD is used newly.
When EEPROM or P.C.B. includin EEPROM was
replaced for repairing.
When recorder was exchanged to another recorder for
repairing.
When customer own second recorder.
When owner of recorder was changed to another.
· We recommend that you make a note of this code for future
reference.
· After playing DivX VOD content for first time, another
registration code is then displayed in “DivX Registration”. do
not use this registration code to purchase DivX VOD
content. If you use this code to purchase DivX VOD content
and the play content on this unit, you will no longer be able
to play any content that you purchased using previous
code.
· If you purchase DivX VOD content using a registration code
different from this unit’s code, you will not be able to play
this content. (“Authorization Error” is displayed.)
Some DivX VOD content can only be played a set number of
times.
When you play this content, remaining number of plays is
displayed. You cannot play this content when number of
remaining plays is zero. (“Rental Expired” is displayed.)
Obtainment/Playback od additional file after Activation
(code/ID is an example)
CASE 5 WHEN OWNER OF RECORDER WAS CHANGED TO
ANOTHER
Activation: File Playback
FILE KIND
(There are two kinf of Activation files as follows too.)
·Rental: There is a playback limitation
·Purchase: Unrestricted
Also there is next file as DRM files besides the abovementioned.
· Base:
It is not necessary to approve though the contents is being
endode.
If it is recorder/player for DRM, any can play back. (It is the
same as usual DivX file when seeing from user.)
SCREEN SHIFT (Error display)
Case 5
Activation
Activation: File obtaining (code/ID are example)
Wheter approval is OK or not.
Wheter the recorder is corresponding to User information on
Divx file includes file to which DRM(Digital Right Management) is applied and file not applied. This item is a content that relates only
in treating file to which DRM is applied.
1. Registration Code display function
2. User’s registration and approval function
3. Rental management function
5.1.3.1. REGISTRATION CODE DISPLAY FUNCTION
Registration Code is alphanumeric character sequence 8 bytes inputted as recorder information, in case a use purchases or rent
a DivX DRM file in a network. Registration code is a character sequence generated at random, and differs in each recorder.
Moreover, Registration code is updated by new user authentication ever if same recorder.
5.1.3.2. USER’S REGISTRATION AND APPROVAL FUNCTION
· Only one user can register for one recorder. If user’s
registration is not done with the recorder, DivX file cannot
be played back.
· User’s registration is performed only when a DivX DRM
file is first chosen by recorder
·DivX DRM file that can perform user’s registration is only a file that is registered Registration Code and purchased or rented.
·User authentication is performed whenever DivX DRM file is played back. Error message is displayed when failing in user’s
registration and approval.
5.1.3.3. RENTAL MANAGEMENT FUNCTION
There are purchase file without registration of number of playback and rental files with registration of number of playback as Divx
file. Number of playback of rental file is counted by the recorder. When rental file is played, remaining number of times that can be
played back will be shown to users, recorder requests users to input yes or no. Following specifications have been installed for the
rental files in the purpose to clarify the count condition of number of times of playback.
· Conditions on counting number of times of play.
1. When a file was opened successfully. (At the time of playback start)
2. When you have done review operation from the start. (Skip to file head)
− At this time, remaining number of times that can be played back and confirmation message
[Do you play really?] are displayed.
− When the playback point has been skipped to the top of title, number of playback is not counted if the top of title was
not recognized.
− Even if the power failure occurs after start of playback of rental file, number of times of playback counted at start of the
playback is held as it is.
(Though playback stops by power failure,
the number of times of playback is not counted.)
When it has reached head of title, the playback is ended, and screen becomes DivX menu (There is no resume) and then cursor
is located on title that has been played back.Then if the same file was continuously played back, it begins to playback from the
file head.
Note:
Above mentioned stored user information and number of times of playback are not erased by update of firmware or by
initialization by test mode.
HDMI is abbreviation of [High-Definition Multimedia Interface], and is digital interface standard for next generation TV
corresponding to follows.
1. Non-compressing high quality digital image
2. Digital transmission of multi channel digital audio.
3. Two way communication of control signal of control straightening between equipments.
CableTransmission
HDMI
Cable
method
Digital
(~4.455Gbps)
DirectionalityTransmission
signal
One-wayDigital image
(none-compression highdefinition television image)
One-wayDigital Audio
(6ch/24 bit high sound quality
PCM of DVD audio/Bit stream
of surround to 8ch of DVD
video)
InteractiveDigital control signal
(Advanced control between
equipments)
Feature
Clock line in one system and data line in three systems
can high-speed communicate high reliability because of
balance communication that uses three respectively
every one system.
Moreover, because high-speed data line in three system
can be used at same time, it has ten of other digital
cables times or more transmission ability.
And can transmit high-definition television image of noncompression, 24 bit high sound quality PCM voice of
multi-CH of DVD audio (to 6ch) and Bit stream signal of
surround to 8ch of DVD video (5.1ch, 6.1ch, and 7.1ch,
etc.) as a digital signal of no deterioration.
It has power supply line and a interactive control signal
line communication independent of AV signal, a Cd can
an advanced control between equipments. Therefore it
can correspond to making of AV equipment in the future
highly a network.
5.2.2. LINK FUNCTIONS
Functions
(1) Automatic Input switch
(2) Link of Power
14
5.2.3. OUTLINE OF EQUIPMENTS
LINKED FUNCTIONS
1. Automatic Input switch
At starting of playback / GUI (Graphical User Interface)
display by DIGA, it turn on power of VIErA, and it displays
picture of DIGA onto screen of VIErA.
a. Starting of playback:
It includes automatic playback of DVD-Video and so on.
And it includes picture of screen saver too.
b. GUI display:
FUNCTIONS, DIRECT NAVIGATOR, TV PROGRAM,
PROG/CHECK, Timer Recording, G-code, Initial setting,
Playback setting, Play list, SD/DVD guide, Warning
messages that user can select and so on.
Self-Diagnosis Function provides information for errors to service personnel by “Self-Diagnosis Display” when any error has
occurred.
U**, H** and F** are stored in memory and held.
You can check latest error code by transmitting [0] [1] of Remote Controller in Service Mode.
Automatic Display on FL will be cancelled when the power is turned off or AC input is turned off during self-diagnosis display is ON.
Error CodeDiagnosis contentsDescriptionMonitor DisplayAutomatic FL display
IR ERRIR communication error[IR ERR] is displayed when communication
between Timer microprocessor and IR
microprocessor fails.
No display
No RECRecording is impossible[No REC] is displayed when recording is
U30Remote control code errorDisplay appears when main unit and remote
U59Abnormal inner temperature
detected
U61The unit is carrying out its
recovery process (with no
disc in the disc tray).
U80ST Microprocessor
Communication Error on
Timer Bus
impossible due to the defect, dirt or wound
of media.
controller codes are not matched.
Display appears when the drive temperature
exceeds 70°C.
The power is turned off forcibly.
For 30 minutes after this, all key entries are
disabled. (Fan motor operates at the highest
speed for the first 5 minutes. For the
remaining 25 minutes, fan motor is also
stopped.) The event is saved in memory as
well.
* The unit detected an error while recording
or playing with with no disc in the disc
tray.
The unit is carrying out its recovery process.
This process restores the unit to normal
operation. The unit is not broken. Wait until
the message disappears.
Displayed appears when ST Microprocessor
Communication Error on Timer Bus occurs.
No display
No display
“*” is remote controller code of the
main unit.
Display for 5 seconds.
No display
“U59 is displayed for 30 minutes.
No display
No display
U81ST Microprocessor
Communication Error on
UART
U88The unit is carrying out its
recovery process (with no
disc in the disc tray).
U99Hang-upDisplayed when communication error has
H19Inoperative fan motorWhen inoperative fan motor is detected after
Displayed appears when ST Microprocessor
Communication Error on UART occurs.
* The unit detected an error while recording
or playing with with no disc in the disc
tray.
The unit is carrying out its recovery process.
This process restores the unit to normal
operation. The unit is not broken. Wait until
the message disappears.
occurred between Main microprocessor and
Timer microprocessor.
powered on, the power is turned off
automatically.
The event is saved in memory.
18
“U80” is displayed till Power Key is
pressed.
No display
“U81” is displayed till Power Key is
pressed.
No display
No display
Displayed is left until the [POWER]
key is pressed.
Error CodeDiagnosis contentsDescriptionMonitor DisplayAutomatic FL display
F00No error informationInitial setting for error code in memory
No displayNo display
(Error code Initialization is possible with error
code initialization and main unit
initialization.)
F58Drive hardware errorWhen drive unit error is detected, the event
No displayNo display
is saved in memory.
F34Initialization error when main
microprocessor is started up
for program recording
When initialization error is detected after
starting up main microprocessor for program
recording, the power is turned off
No displayNo display
automatically.
The event is saved in memory.
UNSUPPORT
Unsupported disc error*An unsupported format disc was played,
although the drive starts normally.
“This disc is
incompatible.”
*The data format is not supported, although
the media type is supported.
*Exceptionally in case of the disc is dirty.
Display for 5 seconds.
NO READ Disc read error*A disc is flawed or dirty.
*A poor quality failed to start.
*The track information could not be read.
“Cannot read.
Please check the
disc.”
HARD
ERR
SELF
CHECK
PLEASE
WAIT
Drive errorThe drive detected a hard error.“DVD drive error.” Display for 5 seconds.
Restoration operationSince the power cord fell out during a power
No display
failure or operation, it is under restoration
operation.
*It will OK, if a display disappears
automatically. If a display does not
disappear, there is the possibility that
defective Digital P.C.B. / RAM drive.
Unit is in termination process Unit is in termination process now.
No display
“BYE” is displayed and power will be turned
off.
In case “Quick Start” of setup menu is ON, it
is displayed in restoration operation for AC
off.
UNFORMAT
Unformatted disc errorYou have inserted an unformatted DVD-
RAM or DVD-RW that is unformatted or
recorded on other equipment.
when start up of HDD was
failed.
(Except error of setting of
Power on Stand-by)
HDD NGPower on Stand-by setting
error
1. When normal start up was failed
2. When start up at HDD boot was failed
3. When start up from state of P-OFF was
failed
4. When start up from state of HDD
SLEEP was failed.
[HDDERR] is displayed when above each
start up of HDD was failed.
* In case 1.), tray opens automatically and
[HDDERR] is displayed until version up disc
is inserted.
[HDD NG] is displayed when power on
Stand-by setting of HDD is NG or when
HDD which power on Stand-by is not set to
is used.
Please try to replace HDD with junine HDD
as service parts.
No display
No display
8.1.2. SPECIAL MODES SETTING
ItemFL displayKey operation
Mode nameDescriptionFront Key
TEST Mode*All the main unit’s parameters (include
tuner) are initialized.
Rating passwordThe audiovisual level setting password is
initialized to “Level 8”.
Press [STOP], [CH UP] and
[OPEN/CLOSE] keys
simultaneously for five seconds
when power is off.
Open the tray, and press [REC]
and [PLAY] simultaneously for 5
seconds.
Service ModeSetting every kind of modes for servicing.
Forced disc ejectRemoving a disc that cannot be ejected.
Child lock/unlockSet or release “Child Lock”.Press [ENTER] and [RETURN] by
NTSC/PAL system select To switch PAL/NTSC altemately.The display before execution
Forced power-offWhen the power button is not effective while
*Details are described in “Service Mode”.
The tray will open and unit will shift to P-off
mode.
*When Timer REC is ON or EXT-LINK is
ON, execute " Forced disc eject " after
releasing Timer REC or EXT-LINK.
*This command is not effective during "Child
lock" is ON.
While Demonstration Lock is being set, this
Forced disc eject function is not accepted.
If this command was executed while
TIMER REC is being set, TIMER REC
setting will be kept.
power is ON, turn off the power forcibly.
*When Timer REC is ON or EXT-LINK is
ON, execute “Forced Power-off” after
releasing Timer REC or EXT-LINK.
The display before execution
leaves.
leaves.
Display in P-off mode.Press [Power] key over than 10
When the power is off, press [CH
UP], [OPEN/CLOSE] and [REC]
keys simultaneously for 5 seconds.
When the power is off, press
[STOP] and [CH UP] keys
simultaneously for 5 seconds.
remote controller simultaneously
until [X-HOLD] is displayed.
While the power is on (E-E mode),
press [STOP] and [OPEN/CLOSE]
simultaneously for 5 seconds.
Caution:
All programs in DVD-RAM disc will be
deleted because Formatting is done once
in Aging process.
Display following the then mode.When the power is ON, press
[STOP], [POWER] and
[OPEN/CLOSE] simultaneously for
over 5 seconds and less than 10
seconds.
NOTE1:
If Unit has not turned into Aging
mode by operations shown above,
execute TEST MODE once and reexecute operation shown above.
(*All the main unit’s parameters
include tuner are initialized by
TEST mode.)
NOTE2:
If the unit has hung-up because of
pressing keys for over 10 seconds,
once turn off the power, and reexecute this command.
*When releasing Aging mode,
press [POWER] key.
Aging Contents (Example):
Demonstration
lock/unlock
Ejection of the disc is prohibited.
The lock setting is effective until unlocking
the tray and not released by “Main unit
initialization” of service mode.
*When lock the tray.
“LOCK” is displayed for 3 seconds.
*When unlock the tray.
“UNLOCK” is displayed for 3
seconds.
*When press OPEN/CLOSE key
while the tray being locked.
Display “LOCK” for 3 seconds.
21
When the power is on, press
[STOP] and [POWER] keys
simultaneously for 5 seconds.
When the power is on, press
[STOP] and [POWER] keys
simultaneously for 5 seconds.
Press [OPEN/CLOSE] key while
the tray being locked.
Magenta Picture Output Magenta picture is output with Component
*Initial mode is “Interlace”.Press [1] [2] in service mode.
Output from AV Decoder.
*Magenta picture
(Saturation rate: 100%)
*It is enable to switch Interlace/Progressive
by “I/P switch: [1] [4]”
Switch Interlace/ProgressivePress [1] [4] in Magenta Picture
Output mode.
*I/P are switched alternately.
RTSC Return in XP
(A & V)
AV1 input signal is encoded (XP), decoded
(XP) and output decoded signal to external
without DISC recording and DISC playback.
I/P SwitchSwitch Interlace and Progressive in EE
mode.
*Initial setting is “Interlace”.
*This command is effective during executing
“White Picture Outpu t”, “Magenta Picture
Output” and “RTSC Return in XP (A & V)”
modes.
Audio Mute (XTMUTE)Check whether mute is applied normally by
the timer microprocessor.
Initial mode: EE2/ Interlace/ XP/
Press [1] [3] in service mode.
Audio 48kHz
Switch Interlace/ProgressivePress [1] [4] in RTSC Return XP
mode.
*I/P are switched alternately.
Audio 44.1 kHz/ 48 kHz SwitchPress [2] [4] in RTSC Return XP
mode.
*48 kHz / 44.1 kHz are switched
alternately.
Initial mode is Interlace
Press [1] [4] in I/P Switch mode.
*I/P are switched alternately.
Switch Interlace/Progressive
Press [2] [1] in service mode.
Audio Mute (XDMUTE)Check whether mute is applied normally by
the Digital P.C.B..
Audio Pattern OutputThe audio pattern stored in the internal
memory is output
(Lch: 1kHz/-18dB)
(Rch: 400Hz/-18dB)
*Audio sound clock switching operation of
DAC can be confirmed by sub command [2]
[4].
Press [2] [2] in service mode.
Initial mode (Audio 48kHz)Press [2] [3] in service mode.
Audio 44.1kHz/48kHz switchingPress [2] [4] in Audio Pattern
Output mode.
*48 kHz / 44.1 kHz are switched
alternately.
HDD READ inspectionPerform a complete read inspection of the
HDD.
Laser Used Time
Check laser used time (hours) of drive.
Indiction
When the HDD is OK
If the HDD is defective
: Judge of Forward rate.
* When normal (Forward rate is 35
Mbps or more and there is no HDD
error):
is Space.
* When Abnormal (Forward rate is
less than 35 Mbps or HDD error
existing):
is X.
: Number of what have
spent time for seeking is over
100ms.
* When norma l:
are spaces.
* When Abnormal: Display Number
of what have spent time fore
seeking over 100 ms.
However, if the number is more
than 100, display [XX].
We judge it is normal that the
number is less than 4.
Press [3] [1] in the service mode.
* When canceling the checking
mode while executing, do “forced
power-off”.
Method: Press the “POWER”
button more than 10 seconds.
Press [4] [1] in service mode.
Delete the Laser Used
Time
Laser used time stored in the memory of the
unit is deleted.
●(*****) is the used time display in
hour.
●Laser used time of DVD/ CD in
Playback/Recording mode is
counted.
Press all front keys and check the
connection between Main P.C.B. and Front
key Switches.
(1) Each time a key is pressed,
segment turned on increases one
by one.
(2) Total umber of keys that have
been pressed.
Production Date Display Display the date when the unit was produced.
YY: Year
MM: Month
DD: Day
Display the accumlated
Display the accumulated unit’s working time.
working time
(Indicating unit: Second)
Display the Error History Display the Error History stored on the unit. Display reason of error for
5 seconds.
Press [5] [4] in service mode.
Press [6] [1] in service mode.
Press [6] [4] in service mode.
Press [6] [5] in service mode.
Then press [0] [1] ~ [1] [9], the
past 19 error histories are
displayed.
01:
Defect of Digital P.C.B.
(AV DEC / MAIN CPU)
02:
Defect of RAM Drive.
03:
Defect of Disc.
04:
Defect of Digital P.C.B. or
Communication Error.
05:
Defect of Digital P.C.B.
(AV DEC / MAIN CPU)
06:
Defect of HDD.
Display the time when the error
has occurred for 5 seconds.
DD: Day
hh: Hour
mm: Minute
Accumulated working time till
occuring of the error is left
displayed.
Delete the Error History Delete Error History information stored on
SD card WRITE checkCheck SD card WRITE function with SD
slot.
When the WRITE check is OK.
When the WRITE check is NG.
Insert a SC card to SD card slot,
and press [7] [4] in service mode.
* Insert SD card while the power is
off.
* Check for [CARD SD] display on
the FL display and go on the
procedure.
*Note:
The image stored in the SD
card will be erased.
AV4(V)/AV1(RGB) I/O
Setting
Set input to AV4 (V) and set output to AV1