X : Deluxe type
K/None : Internal purpose
MK : Indoor unit for Multi zone
Connected Type(Multi-zone)Numeral
: Numeral+K
657
Connection configuration
U1 U6
546
Capacity
2
Cooling Capacity in BTU/h P : Large Capacity series
U -1
Outdoor Unit
U
1
Series
3
89
–P36
Outdoor Unit
Function
4
S : Cooling only
E : Heat pump
23
Category(Function)
4
K : Wall Mount
U : Ceiling Recessed
T : Ceiling suspended
F : Concealed Duct
S : Cooling Only
H : Heat Pump
–S
UC
12
34
Capacity
5
Cooling Capacity in BTU/hDevelopment
S1 U6
546
5
18 NK
657
Development
6
Series No.
U -1
89
7
K : Wall Mount
B4 : Mini Ceiling Recessed
Set
P26
S1 U6
23
Development
Development SeriesU6 : 208/230V 60Hz
546
Voltage
6
Set
S
18 NK
34
Category (Type)
K : Internal-1 : Non-Low Ambient
8
U : 208/230V, 60Hz
1 : 115V, 60Hz
657
Voltage
U -1
Others
9
-1 : Non-Low Ambient
W : Multi/Single Zone
common use
89
Quality
Management
System
Use of the AHRI Certied™ mark indicates
a manufacture's participation in the
certication program.
For verication of certication for individual
products, go to www.ahridirectory.org
Panasonic Corporation of North America
Panasonic Appliances Air-Conditioning North America
Two Riverfront Plaza, Newark, NJ 07102-5490 U.S.A.
us.panasonic.com/aircon
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
Certificate
Certied to ISO 9001: 2008
Cert. No.: MY-AR 1010
Environmental
Management
System
Certificate
Certied to ISO 14001: 2004
Cert. No.: MY-ER 0112
Panasonic Canada Inc.
Enterprise Product Sales
5770 Ambler Dr., Mississauga, ON, L4W 2T3 CANADA
www.panasonic.ca
Certified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-AR 1010
Certified to ISO 14001: 2004
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-ER 0112
in2013
Serving the US Ductless
market since 1983
July 2014
AIR CONDITIONING and
HEAT PUMP PRODUCTS
July 2014
The Panasonic Air Conditioning Group has grown into a global company through its continuous quest for product innovations and technology. The group has evolved from manufacturing compressors to providing comprehensive air conditioning solutions. This has earned Panasonic, the reputation as the most trusted brand for superior energy-efficiency and reliable products.
The History of Panasonic Air Conditioning
1958
1961
1965
1968
1972
1983
1985
1989
1990
Started production and sales of
Home Coolers
The Electrical Appliance Business Group (Kadoma)
star ted cooler production in March 1958. Star ted
sales in May under the “Home Cooler” name.
Started exports of Home Coolers
Launched Room Coolers
Began development of
Rotary Compressors
Later, their high efficiency and high quality attracted
domestic and over seas air conditioner manufactures.
Began external sales.
Established overseas business base in Malaysia
MAICO was established in Malaysia as the
Aircon Group’s first overseas base.
From this time, MAICO started to expor t to
Japan, Indonesia, Australia, and other
markets. Panasonic started operating a
twin-base system with a presence in Japan
and Malaysia.
Launched inverter Air Conditioner
Star ted sales of Panasonic’s first inverter air conditioners and
has since gained increasing popularity. Inverter became the
future technology of air conditioner market.
Launched Ductless Air Conditioners to USA
Began development of Scroll Compressors
Began development of scroll compressors,
offering high ef ficiency, low noise, and low
vibration in comparison to rotar y compressor s.
Introduced Simultaneous Heat & Cool VRF
Launched world’s first Compact Scroll
Compressor-equipped Air Conditioner
1998
2001
2003
2005
2006
2008
2009
2011
Introduced GAS Heater Air Conditioner 14KGS11
Introduced first VRF "ECO-Multi" to USA
Launched first R410a refrigerant Ductless A/C to USA
Launched EcoCute as a result of better
Began production of Multi-split packaged
air conditioner (mini-VRF)
Launched air conditioner
automatic filter cleaning
function (AC robot)
Product became extremely successful in the Japanese
market. Since then, Panasonic launched a series of innovative
products such as airstream robot s and motion sensors which
significantly improved Panasonic’s air conditioner market share.
Renewed ECO-Multi to ECO-i. revised the line-up to
inverter driven
Aggregated global production of
Panasonic compressors reached 200 million units
In 2008 Energy Conservation Grand Prizes,
EcoCute won its first Director General Prize of
Agency of Natural Resources and Energy,
while Panasonic air conditioner won
the Chairman Prize of the Energy
Conservation Center of Japan Started Air
to Water heat pump business in Europe
Established air conditioner dedicated sales company
in Europe (PHAA E)
Panasonic HA Air-Conditioning Europe (PHA AE)
strengthened the commercial air conditioning business.
Integration of Sanyo HVAC USA into
Panasonic Corporation of North America.
Technological Milestones
1998
2001
Introduced revolutionary Gas Heater
Air Conditioner 14KGS11.
That maintains a consistent heating
performance level, regardless of how
much the ambient temperature goes
down outside.
Launched VRF "Eco-Multi"
to the US market.
Eco-Multi was displayed at the AHR
show, and was introduced to other
ductless manufacturers. It’s the new
individual air-conditioning system that
effectively combines a power control
compressor and an electronic
refrigerant control valve.
Heating Operation Schematic
Indoor Unit
On/Off Valve 2
Unsealed Circuit
On/Off
Valve 1
Check Valve 1
Capillary Tube
Orifice
Burner
Refrigerant
Heater
Compressor
Check
Valve 2
Reversing
Valve
Outdoor Heat
Exchanger
1992
1993
Developed industr y’s smallest outdoor air conditioning
unit:“Chi-size”
Established Matsushita-Wanbao (Guangzhou)
Air Conditioner (MWAC)
Established Matsushita-Wanbao
(Guangzhou)Compressor (MWCC)
Established Matsushita Air Conditioner Engineering
(Matsushita ACE)
2013
2014
1995
Started the export of VRF
Celebrating the 30th
anniversary of marketing
in the USA.
SYSTEM 5 and
Wireless
Communication
Serving the US
Ductless market
since 1983
2003
2013
First R410a driven ductless model,
24KS62R, was introduced.
Again, blazed a trail to other ductless
manufacturers.
Introduce EXTERIOS series to US
market
SEER 28.5 Highest Efficient model in
Industry as of 2013/March
12
Air Conditioners and Heat Pumps Line-Up
Panasonic: Your Best Choice in Mini Split Air Conditioning and Heat Pump Systems
Since 1983, Panasonic’s Mini Split Air Conditioner and Heat Pump products offer a wide range of
versatile solutions for cooling and heating requirements for single or multiple rooms.
The indoor unit (evaporator) is mounted inside a room and it is connected to the outdoor unit (condenser)
via refrigerant lines and inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is
required, installation is simple, fast and efficient. Ducted models are also available.
The indoor unit has been uniquely designed to provide whisper quiet operation while delivering comfort
Model Chart
throughout the room (s).
Panasonic Mini Split Systems are stylish and offer whisper-quiet operations, quality and reliability you
can count on.
ECONAVI features intelligent Human Activity Sensor and new
technologies that can detect human activity and absence, and
optimize air conditioner operation according to room conditions.
Room Freeze Protection*
Room Freeze Protection mode helps prevent plumbing damage
due to sub-Freezing Temperature. This mode automatically
turns on the compressor for heat pump operation if the room
temperature falls to about 46°F.
*This function may not be performed if the unit is not powered,
or if the unit is unable to operate such as in protection mode.
Please consult with the HVAC installers or professional for
details.
Microprocessor-Controlled
Operation
Microprocessor control ensures that the temperature and
humidity levels in the room are always comfortable.
Wireless Remote Control
Panasonic’s infrared Remote Control with and easy-to-read LCD
Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for
complete automatic operation.
Dry Mode
By coupling compressor and fan operation, intermittent operation
can be precisely controlled according to room temperature, so
that air is efficiently dehumidified.
5 Fan Speeds and Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan
speed to High, Medium or Low. According to room temperature to
maintain a comfortable airflow throughout the room.
Air Sweep Control
The air sweep function moves the louver up and down in the air
outlet, directing air in a “sweeping” motion around the room and
Features Chart
Wall Mounted
Ceiling Suspended
Ceiling Recessed
Concealed Duct
ECONAVI
Room Freeze
Protection
Microprocessor-
Controlled Operation
Wireless Remote
Control
Wired Remote
Control
Self-Diagnosing
Function
Dry Mode
5 Fan Speeds and
Automatic Fan Operation
Air Sweep Control
Louver Control
Automatic Heating and
Cooling Changeover
Night Setback Mode for
Cooling and Heating
Hot Start Heating
System
24-Hour Clock with
ON/OFF ProgramTimer
1-Hour OFF Timer
Weekly Timer
System Controller
XE9PKUA
XE12PKUA
E9NKUA
E12NKUA
E18NKUA
E24NKUA
KE30NKU
KE36NKU
HEAT PUMPS
KE12NB41
KE18NB4U
26PEK1U6
26PET1U6
36PET1U6
42PET1U6
26PEU1U6
36PEU1U6
42PEU1U6
26PEF1U6
36PEF1U6
STANDARD
S9NKU-1
S12NKU-1
S18NKU-1
S22NKU-1
S9NKUA
S12NKUA
S18NKUA
S24NKUA
LOWAMBIENT AIR CONDITIONERS
KS30NKUA
KS36NKUA
KS12NB41A
KS18NB4UA
26PSK1U6
26PST1U6
36PST1U6
42PST1U6
26PSU1U6
36PSU1U6
42PSU1U6
26PSF1U6
36PSF1U6
l
l
llllllllllllllll
lllll
OPOPOPOPOP
OPOPOP
lll
lllll
-OPOPOPOP
OPOPOP
lll
llllllllllllllll
llllllllllllllll
llllllllllllllll
lllllll
lllllll
llllllll
---
------
l
llllllll
-
lllllll
-
lllllll
--------
ll
----
--------
llllllllllllllll
--
ll
----OP
------
lll
----OP
ll
----
lll
----OPOPOPOP----OPOPOPOP
-
-
providing comfort in every corner.
Filter Sign
Automatic Restart Function
after Power Failure
Fresh Air Intake
Branch Extension
Built-In Drain Pump
Low Ambient
Operation
Electric
Expansion
56
ODP=0 Refrigerant
Quiet Mode
Anti-microbial
Condenser
Valve
Filter
Blue Fin
ll
llllllllllllllll
---
---
---
lll
llllllll
llllllllllllllll
llll
-
ll
--
llllll
-OP*OPOP*---
l
--
l
--
l
-
llll
----
------
l
------
ll
ll
--
---
---
-
lllllll
l
(S18/22)
lllllll
llll
ll
------
lll
llll
-OP*OPOP*
l
-
l
l
lll
--
ll
----
-----
* Field Supplied
Cool/Dry
Mode
Heat Mode
Louver Control
Louver can be manually set to the desired angle by remote
control.
Automatic Heating and Cooling Changeover
After setting the temperature and functions you desire, just relax.
If the room temperature is higher than the set temperature,
cooling operation begins. If the room temperature is lower than
the set temperature, heating operation begins. During normal
thermostat cycle operation, cooling and heating operations
automatically change in accordance with set temperature, time
and room temperature (Single Zone Heat Pump unit only).
1-hour OFF Timer
When this button is pushed either while the unit is operating
or while it is stopped, the unit will operate for one hour, then
switch off automatically.
24-hour Clock with ON/OFF Program Timer
The remote control unit allows you to set a wide variety of
timer-based operations. Such functions include automatic
ON/OFF with a timer setting, same time ON/OFF every day, ON
timer, OFF timer and Combination timer.
Night Setback Mode for Cooling and Heating
Cooling and DRY Mode: With the Night Setback Mode, the
air conditioner automatically raises the setting temperature
2°F after 30 minutes, and then another 2°F after the next 30
minutes.
Heating Mode: With the Night Setback Mode, the setting
temperature is automatically lowered 4°F after 30 minutes, and
then another 4°F after the next 30 minutes. This saves energy
without sacrificing comfort and is ideal for gentle cooling and
heating.
Automatic Restart Function after Power
Failure
This feature allows the system to automatically resume
operation at its preset program, after power is restored from a
power failure when the remote control is in the room.
Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start
Heating System prevents any cold blasts at the beginning while
the heat pump is warming up (Heat pump unit only).
Built-In Drain Pump
Max. head 20 inches from the discharge of the indoor unit.
Condensation pump is only for allowing drain line to meet
minimum gravity flow requirements.
Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse
type electric control valve. In order to attain optimum efficiency,
when the power is switched ON, the opening degree of the electric
control valve is controlled between 90 and 480 steps.
Quiet Mode
LOW, low fan speed for extra quiet operation.
Filter Sign
Filter sign informs you when filter maintenance is necessary.
K1/T1/U1/F1 series with CZ-RTC2
XE/E/S series with CZ-RDC516C-1
(Example of CZ-RTC2)
Self-Diagnosing Function
Units are equipped with Self-Diagnosing Function (methods
are difference depending on the models). This makes it easier
to diagnose malfunctions, greatly reducing service labor (Wired
remote controller).
(Example of CZ-RTC2)
Anti-microbial Filter
Anti-microbial Filter by 3M. This filter is treated to inhibit the
growth of mold and mildew, and helps create clean air.
Test Comparison
Microbial Growth Rating
7 days 28days
Anti-microbialFilterNo growthNo growth
Normal Filter Paper60% growth60% growth
*Tested per ASTM G21-96
Blue Fin Condenser
Condensers can take a beating from exposure to salty air, rain
and other corrosive factors. Panasonic has extended the life of
its condensers with an original anti-rust coating.
Tested for 2,000 salt spray hours.
Features Chart
Deluxe Wall Mounted Heat Pump Series
Panasonic sets another milestone
in the Mini-Split History...
EXTERIOS - the latest breakthrough in energy efficiency and
high performance with Inverter technology,SEER 28.5 and HSPF 12.5
High Energy Efficiency
EXTERIOS
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
Wireless
Remote
Controller
Wired
Remote Controller
(CZ-RD516-1)
(Optional)
SEER
28.5
LOW
AMBIENT
OPERATION
Breakthrough technologies, such as the inverter, enable the highest energy
efficiency* in the industry. Thanks to this exceptional performance,
you will enjoy even more comfort.
*CS/CU-XE9PKUA as of March 2013
XE9PKUA Max Capacity (Heat)
Powerful Heating at Low
Ambient Temperatures
Offers reliable heating with full
capacity down to 5º F.
Capacity(Btu/h)
25000
20000
15000
10000
5000
0
510 15 20 25 30 35 40 45 50
Outdoor Temp(°F)
Inverter Technology
Panasonic’s inverter technology provides optimum power control and extremely
efficient operation by modulating the compressor capacity.
The result is efficient and flexible operation using less electricity.
Panasonic ductless mini split systems are designed
to care for you
With over 50 years of experience of exporting to more than 125 countries
around the world, Panasonic is unquestionably one of the leaders in the
air conditioning business. Panasonic has produced more than 200 million
compressors and has manufactured high quality air conditioners.
78
Advanced Inverter Technology
New added unique features
The Advantages of Inverter Control
Provides Optimum Performance
While Reducing Energy Usage
Panasonic’s inverter technology constantly adjusts its
compressor rotation speed to provide maximum performance
at all times. This extremely precise operation enables
quick cooling or heating while reducing power consumption
compared to conventional non-inverter units.
Reduces Electricity Consumption
Panasonic inverter air conditioners/heat pumps are designed
to give you exceptional energy savings performance while
ensuring you stay comfortable at all times.
Constant Comfort
Precise temperature control with a wide power output range
enables an inverter air conditioner to meet different room
occupancy levels – thus ensuring constant comfort.
Quick Cooling and Heating
Panasonic Inverter air conditioners can operate with higher
cooling/heating power during the start up period to cool/heat
the room faster than non-inverter models.
Whisper Quiet Operation
The indoor operating noise has been reduced by 5dB as the
Inverter constantly varies its output power to enable more
precise temperature control.
Wider Output Power Range
Rated capacity
8,700Btu/h
Maximum capacity
12,000Btu/h
Minimum capacity
2,800Btu/h
ECONAVI with Intelligent Eco Sensors
In 2007, Panasonic launched ECONAVI (Human Detection Technology) to its air conditioners.
The ECONAVI sensors moderate the temperature in a room and senses when there is activity;
which then automatically adjusts the temperature setting accordingly for maximum energy efficient operation.
The absence detection feature switches to a slightly less powerful cooling mode when the room is empty.
Absence Detection
ECONAVI detects human
absence from the room
and raises the target
temperature.
Absence Detection
Reduces cooling and heating
power when you are not in the
room.
DETECTCONTROL
No one is in the room.
Detects absence.
ECONAVI in cooling mode: *The target temperature set by ECONAVI will be restored automatically to the set temperature when the new condition is detected.
Gradually modulates cooling
power by setting the new
target temperature
(set temp +4˚F)
Activity Detection
ECONAVI detects changes in
activity levels and reduces
the cooling power by
adjusting set temperature.
Level of activity is
decreased. Detects low
activity.
Activity Detection
Adjusts cooling and
heating power to your
activities.
Human
Activity Sensor
CONTROLDETECT
Reduces cooling power by
setting new target
temperature
(set temp +2˚F)
Comparing inverter and non-inverter air conditioners to cars…
Cooler
Uncomfortable
Adjusts the accelerator and
thus runs more economically.
Reaches the comfortable
zone quickly.
The accelerator can't be adjusted, so you spend a long
time getting comfortable, then soon become uncomfortable.
*Image of output power fluctuation
Keeps the temperature
comfortable all the time.
How Does ECONAVI Human Activity Work?
1
2
Present
High activity
3
Normal activity
Absent
Exit RoomOutLow activityEnter Room
4
5
Comfortable
+4°F
Setting Temperature
Room temperature
Uncomfortable
Less Cool
910
START
Runs at a fixed speed and takes
longer to reach the comfort zone.
The room gets too cold,
then too warm.
Inverter air conditioner
Non-inverter air conditioner
Set Temperature
-2°F
Fan Speed
Legend:
Set Temperature
20min.
+2°F
Cooling Power
-4°F
Heating Power
20min.
1 Hour
Max Medium FanSet SpeedSet SpeedSet Speed
Remark: Set temperature on remote control display remains unchanged.
+2°C