Panasonic DL04060835, DL04080815, DL04080820, DL04080835, DL04100820 Specifications

...
Model Identification
RAC
Indoor Unit
SC
1 2
Series
1
C: Residential
PAC
Indoor Unit
P26
S
2 3
1
ModelType
1
S : Indoor unit
U : Outdoor Unit
S
3 4
2
S:Indoor unit U:Outdoor unit
18 N K
ModelType
3
X : Deluxe type K/None : Internal purpose MK : Indoor unit for Multi zone
Connected Type(Multi-zone)Numeral : Numeral+K
65 7
Connection configuration
U 1 U6
54 6
Capacity
2
Cooling Capacity in BTU/h P : Large Capacity series
U -1
Outdoor Unit
U
1
Series
3
8 9
P36
Outdoor Unit
Function
4
S : Cooling only E : Heat pump
2 3
Category(Function)
4
K : Wall Mount U : Ceiling Recessed T : Ceiling suspended F : Concealed Duct
S : Cooling Only H : Heat Pump
S
UC
1 2
3 4
Capacity
5
Cooling Capacity in BTU/hDevelopment
S 1 U6
54 6
5
18 N K
65 7
Development
6
Series No.
U -1
8 9
7
K : Wall Mount B4 : Mini Ceiling Recessed
Set
P26
S 1 U6
2 3
Development
Development Series U6 : 208/230V 60Hz
54 6
Voltage
6
Set
S
18 N K
3 4
Category (Type)
K : Internal -1 : Non-Low Ambient
8
U : 208/230V, 60Hz 1 : 115V, 60Hz
65 7
Voltage
U -1
Others
9
-1 : Non-Low Ambient W : Multi/Single Zone
common use
8 9
Quality Management System
Use of the AHRI Certied™ mark indicates a manufacture's participation in the certication program. For verication of certication for individual products, go to www.ahridirectory.org
Panasonic Corporation of North America Panasonic Appliances Air-Conditioning North America Two Riverfront Plaza, Newark, NJ 07102-5490 U.S.A. us.panasonic.com/aircon
Because its products are subject to continuous improvements, Panasonic reserves the right to modify product design and specifications without notice and without incurring any obligations. ©Copyright 2012, Panasonic Air Conditioning Products.
Caution Related to Safety
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
Certificate
Certied to ISO 9001: 2008
Cert. No.: MY-AR 1010
Environmental Management System Certificate
Certied to ISO 14001: 2004
Cert. No.: MY-ER 0112
Panasonic Canada Inc. Enterprise Product Sales 5770 Ambler Dr., Mississauga, ON, L4W 2T3 CANADA www.panasonic.ca
Certified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M) Sdn.Bhd. Cert. No.: MY-AR 1010
Certified to ISO 14001: 2004
Panasonic HA Air-Conditioning (M) Sdn.Bhd. Cert. No.: MY-ER 0112
in2013
Serving the US Ductless market since 1983
July 2014
AIR CONDITIONING and
HEAT PUMP PRODUCTS
July 2014
The Panasonic Air Conditioning Group has grown into a global company through its continuous quest for product innovations and technology. The group has evolved from manufacturing compressors to providing comprehensive air conditioning solutions. This has earned Panasonic, the reputation as the most trusted brand for superior energy-efficiency and reliable products.
The History of Panasonic Air Conditioning
1958
1961
1965
1968
1972
1983
1985
1989
1990
Started production and sales of Home Coolers
The Electrical Appliance Business Group (Kadoma) star ted cooler production in March 1958. Star ted sales in May under the “Home Cooler” name.
Started exports of Home Coolers
Launched Room Coolers
Began development of Rotary Compressors
Later, their high efficiency and high quality attracted domestic and over seas air conditioner manufactures. Began external sales.
Established overseas business base in Malaysia
MAICO was established in Malaysia as the Aircon Group’s first overseas base. From this time, MAICO started to expor t to Japan, Indonesia, Australia, and other markets. Panasonic started operating a twin-base system with a presence in Japan and Malaysia.
Launched inverter Air Conditioner
Star ted sales of Panasonic’s first inverter air conditioners and has since gained increasing popularity. Inverter became the future technology of air conditioner market.
Launched Ductless Air Conditioners to USA
Began development of Scroll Compressors
Began development of scroll compressors, offering high ef ficiency, low noise, and low vibration in comparison to rotar y compressor s.
Introduced Simultaneous Heat & Cool VRF
Launched world’s first Compact Scroll Compressor-equipped Air Conditioner
1998
2001
2003
2005
2006
2008
2009
2011
Introduced GAS Heater Air Conditioner 14KGS11
Introduced first VRF "ECO-Multi" to USA
Launched first R410a refrigerant Ductless A/C to USA Launched EcoCute as a result of better
energy-saving technology Launched accumulator-less, high-efficiency,
CO
scroll compressor for EcoCute
2
Began production of Multi-split packaged air conditioner (mini-VRF)
Launched air conditioner automatic filter cleaning function (AC robot)
Product became extremely successful in the Japanese market. Since then, Panasonic launched a series of innovative products such as airstream robot s and motion sensors which significantly improved Panasonic’s air conditioner market share.
Renewed ECO-Multi to ECO-i. revised the line-up to inverter driven
Aggregated global production of Panasonic compressors reached 200 million units
In 2008 Energy Conservation Grand Prizes, EcoCute won its first Director General Prize of Agency of Natural Resources and Energy, while Panasonic air conditioner won the Chairman Prize of the Energy Conservation Center of Japan Started Air to Water heat pump business in Europe
Established air conditioner dedicated sales company in Europe (PHAA E)
Panasonic HA Air-Conditioning Europe (PHA AE) strengthened the commercial air conditioning business.
Integration of Sanyo HVAC USA into Panasonic Corporation of North America.
Technological Milestones
1998
2001
Introduced revolutionary Gas Heater Air Conditioner 14KGS11.
That maintains a consistent heating performance level, regardless of how much the ambient temperature goes down outside.
Launched VRF "Eco-Multi" to the US market.
Eco-Multi was displayed at the AHR show, and was introduced to other ductless manufacturers. It’s the new individual air-conditioning system that effectively combines a power control compressor and an electronic refrigerant control valve.
Heating Operation Schematic
Indoor Unit
On/Off Valve 2
Unsealed Circuit
On/Off Valve 1
Check Valve 1
Capillary Tube
Orifice
Burner
Refrigerant Heater
Compressor
Check
Valve 2
Reversing Valve
Outdoor Heat
Exchanger
1992
1993
Developed industr y’s smallest outdoor air conditioning unit:“Chi-size”
Established Matsushita-Wanbao (Guangzhou) Air Conditioner (MWAC) Established Matsushita-Wanbao (Guangzhou)Compressor (MWCC) Established Matsushita Air Conditioner Engineering (Matsushita ACE)
2013
2014
1995
Started the export of VRF
Celebrating the 30th anniversary of marketing in the USA.
SYSTEM 5 and Wireless Communication
Serving the US Ductless market since 1983
2003
2013
First R410a driven ductless model, 24KS62R, was introduced.
Again, blazed a trail to other ductless manufacturers.
Introduce EXTERIOS series to US market
SEER 28.5 Highest Efficient model in Industry as of 2013/March
1 2
Air Conditioners and Heat Pumps Line-Up
Panasonic: Your Best Choice in Mini Split Air Conditioning and Heat Pump Systems
Since 1983, Panasonic’s Mini Split Air Conditioner and Heat Pump products offer a wide range of versatile solutions for cooling and heating requirements for single or multiple rooms. The indoor unit (evaporator) is mounted inside a room and it is connected to the outdoor unit (condenser) via refrigerant lines and inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is required, installation is simple, fast and efficient. Ducted models are also available. The indoor unit has been uniquely designed to provide whisper quiet operation while delivering comfort
Model Chart
throughout the room (s). Panasonic Mini Split Systems are stylish and offer whisper-quiet operations, quality and reliability you can count on.
HEAT PUMP MODELS
Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000
MODEL
(System)
EXTERIOS
Wall
Mounted
XE12PKUA
E9NKUA
CS-XE9PKUA CU-XE9PKUA
XE9PKUA, E12NKUA
KE12NB41
CS-XE12PKUA CU-XE12PKUA
E18NKUA
KE18NB4U
E24NKUA
26PEK1U6, 26PET1U6 26PEU1U6, 26PEF1U6
KE30NKU
KE36NKU, 36PET1U6
36PEU1U6, 36PEF1U6
42PET1U6 42PEU1U6
*Please refer to the model identification on the back of this catalog.
COOLING ONLY MODELS / LOW AMBIENT TYPE
Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000
Low Ambient Type
MODEL
(System)
Wall
Mounted
Wall
Mounted
Ceiling
Suspended
AIR CONDITIONER
Ceiling
Recessed
Concealed
Duct
Outdoor
S9NKUA
CS-S9NKUA CU-S9NKUA
S12NKUA
KS12NB41A
CS-S12NKUA CU-S12NKUA
CS-KS12NB41 CS-KS18NB4UW S-26PU1U6
CU-KS12NK1A CU-KS18NKUA U-26PS1U6 U-36PS1U6
S18NKUA
KS18NB4UA
CS-S18NKUA CU-S18NKUA
S24NKUA
CS-S24NKUA CU-S24NKUA
26PSK1U6, 26PST1U6 26PSU1U6,26PSF1U6
S-26PK1U6
S-26PT1U6 S-36PT1U6 S-42PT1U6
S-26PF1U6 S-36PF1U6
KS30NKUA
CS-KS30NKU
CU-KS30NKUA
KS36NKUA, 36PST1U6 36PSU1U6, 36PSF1U6
CS-KS36NKU
CU-KS36NKUA
S-36PU1U6 S-42PU1U6
42PST1U6
42PSU1U6
U-42PS1U6
Model Chart
Wall
Low Ambient Type
HEAT PUMP WITHOUT HEATER
Mounted
Wall
Mounted
Ceiling
Suspended
Ceiling
Recessed
Concealed
Duct
Outdoor
CS-E9NKUAW
CU-E9NKUA
CS-E12NKUAW
CU-E12NKUA
CS-KE12NB41 CS-KE18NB4UW S-26PU1U6 S-36PU1U6 S-42PU1U6
CU-KE12NK1 CU-KE18NKU U-26PE1U6 U-36PE1U6 U-42PE1U6
CS-E18NKUA
CU-E18NKUA
CS-E24NKUA CU-E24NKUA
CS-KE30NKU CU-KE30NKU
S-26PK1U6
S-26PT1U6 S-36PT1U6 S-42PT1U6
S-26PF1U6 S-36PF1U6
COOLING ONLY MODELS / STANDARD TYPE
Btu/h 9,000 12,000 18,000 22,000
Standard Type
MODEL
(System)
Wall
Mounted
AIR CONDITIONER
S9NKU-1 S12NKU-1
CS-S9NKUW-1 CU-S9NKU-1 CS-S12NKUW-1 CU-S12NKU-1 CS-S18NKU-1 CU-S18NKU-1 CS-S22NKU-1 CU-S22NKU-1
S18NKU-1, KS18NKU
KS18NB4U
CS-KE36NKU CU-KE36NKU
S22NKU-1
MULTI ZONE MODELS
Series S series / E series KS series / KE series
Btu/h 9,000 12,000 7,000 9,000 12,000 18,000 24,000
Wall
Mounted
CS-S9NKUW-1/CS-S12NKUW-1
Indoor Unit
Ceiling
Recessed
AIR CONDDITIONER
Btu/h 19,000 24,000 31,000
Outdoor
Outdoor Unit
Btu/h 7,000 9,000 12,000 7,000 9,000 12,000 18,000 24,000 7,000 9,000 12,000 18,000 24,000
Wall
Mounted
Indoor Unit
Ceiling
Recessed
HEAT PUMP
Btu/h 19,000 24,000 31,000
Outdoor
Outdoor Unit
18,000
CU-2S18NBU-1
CS-ME7QKUA/
CS-E9NKUAW/CS-E12NKUAW
CU-2E18NBU CU-5E36OBU CU-3KE19NBU
CS-ME70KUA/CS-E9NKUA/CS-E12NKUA
NEW
CS-E18NKUA/
CS-E24NKUA CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU
CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU
CS-MKS9NB4U CS-MKS12NB4U CS-KS18NB4UW
CU-3KS19NBU
CU-4KS24NBU CU-4KS31NBU
CS-MKE9NB4U CS-MKE12NB4U CS-KE18NB4UW
CU-4KE24NBU CU-4KE31NBU
3 4
Model Feature Chart Features
Flap
Setting temperature
Setting temperature
Press the NIGHT SETBACK button
Press the NIGHT SETBACK button
30 min. 30 min.
Time
30 min. 30 min.
Time
2˚F
2˚F
4˚F
4˚F
In Cooling and DRY Mode
In Heating Mode
OP: Option
ECONAVI
ECONAVI features intelligent Human Activity Sensor and new technologies that can detect human activity and absence, and optimize air conditioner operation according to room conditions.
Room Freeze Protection*
Room Freeze Protection mode helps prevent plumbing damage due to sub-Freezing Temperature. This mode automatically turns on the compressor for heat pump operation if the room temperature falls to about 46°F.
*This function may not be performed if the unit is not powered, or if the unit is unable to operate such as in protection mode. Please consult with the HVAC installers or professional for details.
Microprocessor-Controlled Operation
Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.
Wireless Remote Control
Panasonic’s infrared Remote Control with and easy-to-read LCD Display, gives the user the capability to adjust & set: tempera­ture, sweep (louver control), fan speeds, timer and more, for complete automatic operation.
Dry Mode
By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.
5 Fan Speeds and Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.
Air Sweep Control
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and
Features Chart
Wall Mounted
Ceiling Suspended
Ceiling Recessed
Concealed Duct
ECONAVI
Room Freeze
Protection
Microprocessor-
Controlled Operation
Wireless Remote
Control
Wired Remote
Control
Self-Diagnosing
Function
Dry Mode
5 Fan Speeds and
Automatic Fan Operation
Air Sweep Control
Louver Control
Automatic Heating and
Cooling Changeover
Night Setback Mode for
Cooling and Heating
Hot Start Heating
System
24-Hour Clock with
ON/OFF ProgramTimer
1-Hour OFF Timer
Weekly Timer
System Controller
XE9PKUA
XE12PKUA
E9NKUA E12NKUA E18NKUA E24NKUA
KE30NKU KE36NKU
HEAT PUMPS
KE12NB41 KE18NB4U
26PEK1U6
26PET1U6 36PET1U6 42PET1U6
26PEU1U6 36PEU1U6 42PEU1U6
26PEF1U6 36PEF1U6
STANDARD
S9NKU-1 S12NKU-1 S18NKU-1 S22NKU-1
S9NKUA S12NKUA S18NKUA S24NKUA
LOWAMBIENT AIR CONDITIONERS
KS30NKUA KS36NKUA
KS12NB41A KS18NB4UA
26PSK1U6
26PST1U6 36PST1U6 42PST1U6
26PSU1U6 36PSU1U6 42PSU1U6
26PSF1U6 36PSF1U6
l
l
l l l l l l l l l l l l l l l l
l l l l l
OP OP OP OP OP
OP OP OP
l l l
l l l l l
- OP OP OP OP
OP OP OP
l l l
l l l l l l l l l l l l l l l l
l l l l l l l l l l l l l l l l
l l l l l l l l l l l l l l l l
l l l l l l l
l l l l l l l
l l l l l l l l
- - -
- - - - - -
l
l l l l l l l l
-
l l l l l l l
-
l l l l l l l
- - - - - - - -
l l
- - - -
- - - - - - - -
l l l l l l l l l l l l l l l l
- -
l l
- - - - OP
- - - - - -
l l l
- - - - OP
l l
- - - -
l l l
- - - - OP OP OP OP - - - - OP OP OP OP
-
-
providing comfort in every corner.
Filter Sign
Automatic Restart Function
after Power Failure
Fresh Air Intake
Branch Extension
Built-In Drain Pump
Low Ambient
Operation
Electric
Expansion
5 6
ODP=0 Refrigerant
Quiet Mode
Anti-microbial
Condenser
Valve
Filter
Blue Fin
l l
l l l l l l l l l l l l l l l l
- - -
- - -
- - -
l l l
l l l l l l l l
l l l l l l l l l l l l l l l l
l l l l
-
l l
- -
l l l l l l
- OP* OP OP* - - -
l
- -
l
- -
l
-
l l l l
- - - -
- - - - - -
l
- - - - - -
l l
l l
- -
- - -
- - -
-
l l l l l l l
l
(S18/22)
l l l l l l l
l l l l
l l
- - - - - -
l l l
l l l l
- OP* OP OP*
l
-
l
l
l l l
- -
l l
- - - -
- - - - -
* Field Supplied
Cool/Dry Mode
Heat Mode
Louver Control
Louver can be manually set to the desired angle by remote control.
Automatic Heating and Cooling Changeover
After setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature (Single Zone Heat Pump unit only).
1-hour OFF Timer
When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour, then switch off automatically.
24-hour Clock with ON/OFF Program Timer
The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.
Night Setback Mode for Cooling and Heating
Cooling and DRY Mode: With the Night Setback Mode, the
air conditioner automatically raises the setting temperature 2°F after 30 minutes, and then another 2°F after the next 30 minutes. Heating Mode: With the Night Setback Mode, the setting temperature is automatically lowered 4°F after 30 minutes, and then another 4°F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating.
Automatic Restart Function after Power Failure
This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure when the remote control is in the room.
Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up (Heat pump unit only).
Built-In Drain Pump
Max. head 20 inches from the discharge of the indoor unit. Condensation pump is only for allowing drain line to meet minimum gravity flow requirements.
Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.
Quiet Mode
LOW, low fan speed for extra quiet operation.
Filter Sign
Filter sign informs you when filter maintenance is necessary.
K1/T1/U1/F1 series with CZ-RTC2 XE/E/S series with CZ-RDC516C-1
(Example of CZ-RTC2)
Self-Diagnosing Function
Units are equipped with Self-Diagnosing Function (methods are difference depending on the models). This makes it easier to diagnose malfunctions, greatly reducing service labor (Wired remote controller).
(Example of CZ-RTC2)
Anti-microbial Filter
Anti-microbial Filter by 3M. This filter is treated to inhibit the growth of mold and mildew, and helps create clean air.
Test Comparison
Microbial Growth Rating
7 days 28days
Anti-microbialFilter No growth No growth
Normal Filter Paper 60% growth 60% growth
*Tested per ASTM G21-96
Blue Fin Condenser
Condensers can take a beating from exposure to salty air, rain and other corrosive factors. Panasonic has extended the life of its condensers with an original anti-rust coating. Tested for 2,000 salt spray hours.
Features Chart
Deluxe Wall Mounted Heat Pump Series
Panasonic sets another milestone in the Mini-Split History...
EXTERIOS - the latest breakthrough in energy efficiency and high performance with Inverter technology,SEER 28.5 and HSPF 12.5
High Energy Efficiency
EXTERIOS
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
Wireless Remote Controller
Wired Remote Controller (CZ-RD516-1) (Optional)
SEER
28.5
LOW
AMBIENT
OPERATION
Breakthrough technologies, such as the inverter, enable the highest energy efficiency* in the industry. Thanks to this exceptional performance, you will enjoy even more comfort.
*CS/CU-XE9PKUA as of March 2013
XE9PKUA Max Capacity (Heat)
Powerful Heating at Low Ambient Temperatures
Offers reliable heating with full capacity down to 5º F.
Capacity(Btu/h)
25000
20000
15000
10000
5000
0
5 10 15 20 25 30 35 40 45 50
Outdoor Temp(°F)
Inverter Technology
Panasonic’s inverter technology provides optimum power control and extremely efficient operation by modulating the compressor capacity. The result is efficient and flexible operation using less electricity.
Panasonic ductless mini split systems are designed to care for you
With over 50 years of experience of exporting to more than 125 countries around the world, Panasonic is unquestionably one of the leaders in the air conditioning business. Panasonic has produced more than 200 million compressors and has manufactured high quality air conditioners.
7 8
Advanced Inverter Technology
New added unique features
The Advantages of Inverter Control
Provides Optimum Performance While Reducing Energy Usage
Panasonic’s inverter technology constantly adjusts its compressor rotation speed to provide maximum performance at all times. This extremely precise operation enables quick cooling or heating while reducing power consumption compared to conventional non-inverter units.
Reduces Electricity Consumption
Panasonic inverter air conditioners/heat pumps are designed to give you exceptional energy savings performance while ensuring you stay comfortable at all times.
Constant Comfort
Precise temperature control with a wide power output range enables an inverter air conditioner to meet different room occupancy levels – thus ensuring constant comfort.
Quick Cooling and Heating
Panasonic Inverter air conditioners can operate with higher cooling/heating power during the start up period to cool/heat the room faster than non-inverter models.
Whisper Quiet Operation
The indoor operating noise has been reduced by 5dB as the Inverter constantly varies its output power to enable more precise temperature control.
Wider Output Power Range
Rated capacity
8,700Btu/h
Maximum capacity
12,000Btu/h
Minimum capacity
2,800Btu/h
ECONAVI with Intelligent Eco Sensors
In 2007, Panasonic launched ECONAVI (Human Detection Technology) to its air conditioners. The ECONAVI sensors moderate the temperature in a room and senses when there is activity; which then automatically adjusts the temperature setting accordingly for maximum energy efficient operation. The absence detection feature switches to a slightly less powerful cooling mode when the room is empty.
Absence Detection
ECONAVI detects human absence from the room and raises the target temperature.
Absence Detection
Reduces cooling and heating power when you are not in the room.
DETECT CONTROL
No one is in the room. Detects absence.
ECONAVI in cooling mode: *The target temperature set by ECONAVI will be restored automatically to the set temperature when the new condition is detected.
Gradually modulates cooling power by setting the new target temperature (set temp +4˚F)
Activity Detection
ECONAVI detects changes in activity levels and reduces the cooling power by adjusting set temperature.
Level of activity is decreased. Detects low activity.
Activity Detection
Adjusts cooling and heating power to your activities.
Human Activity Sensor
CONTROLDETECT
Reduces cooling power by setting new target temperature (set temp +2˚F)
Comparing inverter and non-inverter air conditioners to cars…
Cooler
Uncomfortable
Adjusts the accelerator and thus runs more economically.
Reaches the comfortable zone quickly.
The accelerator can't be adjusted, so you spend a long time getting comfortable, then soon become uncomfortable.
*Image of output power fluctuation
Keeps the temperature comfortable all the time.
How Does ECONAVI Human Activity Work?
1
2
Present
High activity
3
Normal activity
Absent
Exit Room OutLow activityEnter Room
4
5
Comfortable
+4°F
Setting Temperature
Room temperature
Uncomfortable
Less Cool
9 10
START
Runs at a fixed speed and takes longer to reach the comfort zone.
The room gets too cold, then too warm.
Inverter air conditioner
Non-inverter air conditioner
Set Temperature
-2°F
Fan Speed
Legend:
Set Temperature
20min.
+2°F
Cooling Power
-4°F
Heating Power
20min.
1 Hour
Max Medium FanSet Speed Set Speed Set Speed
Remark: Set temperature on remote control display remains unchanged.
+2°C
+4°F
-4°F
Loading...
+ 14 hidden pages