Panasonic CS-W7CKP, CS-W9CKP, CU-W7CKP5, CU-W9CKP5, CS-W12CKP Service Manual

...
1 Features 2
2 Functions
3
3 Product Specifications
6
4 Dimensions
12
5 Refrigeration Cycle Diagram
14
15
7 Wiring Diagram
16
8 Operation Details
17
9 Operating Instructions
39
10 Installation Instructions
44
© 2002 Matsushita Industrial Corp. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.
CS-W7CKP CU-W7CKP5 CS-W9CKP CU-W9CKP5 CS-W12CKP CU-W12CKP5
11 Installation and Servicing Air Conditioner Using R410A 54
12 Servicing Information
65
13 Troubleshooting Guide
69
14 Technical Data
71
15 Exploded View
76
16 Replacement Parts List
77
17 Exploded View
78
18 Replacement Parts List
79
19 Electronic Circuit Diagram
80
Room Air Conditioner
CONTENTS
Page Page
Order No. MAC0210044C2
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
High Efficiency
Compact Design
Comfort Environment
Ionizer control for generate negative ion in discharge air
Air filter with function to reduce dust and smoke
Wider range of horizontal discharge air
Auto Restart
Random auto restart after power failure for safety restart operation
Removable and Washable Front Panel
Remote Control Self-illuminating Button
Catechin Air Purifying Filter
Trap dust, tobacco smoke and tiny particles
Prevent the growth of bacteria and viruses trapped
Triple Deodorizing Filter
Absorb odours produced by wall paper, construction material and living environment
Quality Improvement
Gas leakage protection
Prevent compressor reverse cycle
2-stage OLP to protect compressor
Noise prevention during soft dry operation.
Compressor Protection Control (Cooling & Soft Dry)
Overload Protection Control (Heating)
Outdoor Fan Control
Compressor High Pressure Control
Blue Coated Condenser
High resistance to corrosion.
Operation Improvement
Quiet mode to provide extra quiet operation
Powerful mode to reach the desired room temperature
quickly
Long Installation Piping
CS/CU-W7CK, CS/CU-W9CK, long piping up to 10 meter
CS/CU-W12CK, long piping up to 15 meter
24-hour Timer Setting
Environmental Friendly
R410A, which does not contain chlorine, is used as its refrigerant, so there is no danger of damage to the ozone layer in Stratosphere.
1 Features
2
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
2 Functions
Remote Control
Operation OFF / ON
OFF / ON I
Room Temperature Setting
TEMP.
Operation Mode Selection
AUTO
Automatic Operation Mode
HEAT
Heating Operation Mode
COOL
Cooling Operation Mode
DRY
Soft Dry Operation Mode
MODE
TIME
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Indoor Fan Speed Selection
FAN SPEED
FAN
Low Fan Speed
FAN
Medium Fan Speed
FAN
High Fan Speed
AUTO
Automatic Fan Speed
FAN
Vertical Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
ON-TIMER OFF-TIMER
Timer Operation Selection
SET CANCEL
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and cancellation.
CLOCK
AIR SWING
AUTO
Automatic Vertical Airflow Direction Control
MANUAL
Vertical Airflow Direction Manual Control (5 stages of adjustment)
Powerful Mode Operation OFF/ON
POWERFUL
Quiet Mode Operation OFF/ON
QUIET
Heating, Cooling, Soft Dry Operation.
• Temperature Setting (16°C to 30°C)
Automatic Operation
Operation with 2°C higher than standard temperature.
Operation with standard temperature.
Operation with 2°C lower than standard temperature.
Self illuminating
button
Ionizer Operation OFF / ON
3
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Indoor Unit
Random Auto Restart Control
Operation is restarted randomly after power failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat exchanger. (Cooling and Soft Dry)
Ionizer Control
Ionizer control for generate negative ion in discharge air.
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed Mode
Heating : Fan speed varies from Me
SSLo in accordance with indoor heat exchanger.
– Cooling : Fan rotates at Hi, Me and SLo
speed. Deodorizing control is available.
– Soft Dry : Fan rotates at Lo- speed.
Deodorizing control is available.
Automatic air swing and manual adjusted by remote control for vertical airflow.
Manually adjusted by hand for horizontal airflow.
Airflow Direction Control
Automatic Operation Button
Press for < 5s to operate Automatic operation mode. (Used when the remote control cannot be used.)
Press continuously for 5s or < 10s to operate Test Run/Pump down. “Beep” sound will be heard at the 5th second. (Used when test running or servicing.)
Press continuously for 10s and above to omit or resume the remote control signal receiving sound. Beep, beep sound will be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
(Green) ......... Lights up in operation,
blinks in Automatic Operation Mode judging.
QUIET
(Orange) ......... Lights up in Quiet Mode
Operation.
TIMER
(Orange) ......... Lights up in Timer
Setting.
POWERFUL
(Orange) ... Lights up in Powerful
Mode Operation.
(Green) ............ Lights up in Ionizer
Mode Operation.
Operation Mode
Heating, Cooling, Soft Dry and Automatic Mode.
Powerful Operation
Reaches the desired room temperature quickly.
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
Starting Current Control
Quiet Operation
To provide extra quiet operation.
7 Minutes Time Save Control
Cooling Operation only.
Fan motor is delayed for 1.6 seconds when
compressor starts simultaneously.
30 Minutes Time Save Control
Heating Operation only.
Hot-Start Control
At Heating Operation the indoor fan will operate at SLo speed when indoor heat exchanger temperature reaches 30°C.
Anti Cold Draft Control
The indoor fan operates at SSLo when the indoor heat exchanger temperature is low. (During Heating mode thermal off)
4
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Outdoor Unit
To protect compressor from reverse rotation when there is a instantaneous power failure.
60 Secs. Forced Operation Control
Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal.
Overload Protector
2-Stage OLP to protect the compressor. Overload Protector will trip when – Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor. (Refer circuit diagram for OLP characteristic)
Compressor Reverse Rotation Protection Control
Outdoor Fan Operation Control
Temperature Fuse.
4-Way Valve Control
When the unit is switched to OFF during Heating Operation, 4-way valve stays at Heating position for 5 minutes.
Overload Protection Control
Outdoor fan stops when indoor heat exchanger temperature rises to 51°C and above, and restarts when the indoor heat exchanger temperature drops to 49°C and below.
Compressor stop when indoor heat exchanger temperature reaches 65°C or above. (Heating Operation Only)
Deice Control
To prevent frosting at outdoor heat exchanger. (Only for Heating Operation)
Temperature of outdoor heat exchanger is sensed by TRS (Thermal Reed Switch). TRS OFF temperature 4°C. TRS ON temperature -3°C.
Compressor Protection Control
If the outdoor fan motor is not running after compressor starts for 50 secs., compressor will stop. (Cooling and Soft Dry Operation only).
5
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
3 Product Specifications
Unit CS-W7CKP CU-W7CKP5
Cooling Capacity kW (kcal/h) 2.38 (2,050)
BTU/h 8,120
Heating Capacity kW (kcal/h) 2.45 (2,110)
BTU/h 8,350
Moisture Removal l/h (Pint/h) 1.5 (3.2)
Phase Single
Power Source V 230
Cycle 50
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Indoor Air (Lo) m3/min (cfm) Cooling; 6.4 (230)
Heating; 7.0 (250)
Indoor Air (Me) m3/min (cfm) Cooling; 7.6 (270)
Heating; 7.7 (270)
Indoor Air (Hi) m3/min (cfm) Cooling; 8.5 (300) Cooling; 34.5 (1,220)
Heating; 9.9 (350)
Indoor Air (SHi) m3/min (cfm) Cooling; 9.9 (350)
Heating; 9.9 (350)
Noise Level dB (A) Cooling; High 34, Low 26 Cooling; High 46
Heating; High 36, Low 26 Heating; High 48
Power level dB Cooling; High 47 Cooling; High 61
Heating; High 49 Heating; High 63
Electrical Data Input W Cooling; 660
Heating; 595
Running Current A Cooling; 3.0
Heating; 2.7
EER W/W (BTU/hW) Cooling; 3.61 (12.3) COP W/W (BTU/hW) Heating; 4.12 (14.0) Starting Current A 12.5
Piping Connection Port (Flare piping)
inch inch
G ; Half Union 3/8 L ; Half Union 1/4
G ; 3-way valve 3/8
L ; 2-way valve 1/4
Pipe Size (Flare piping)
inch inch
G ; (gas side) 3/8
L ; (liquid side) 1/4
G ; (gas side) 3/8
L ; (liquid side) 1/4
Drain Hose
Inner diameter mm 12 Length mm 650
Power Cord Length Number of core-wire
m 1.9
3 (1.0 mm
2
)
— —
6
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Unit CS-W7CKP CU-W7CKP5
Dimensions Height inch (mm) 10 - 13/16 (275) 21 - 1/4 (540)
Width inch (mm) 31 - 15/32 (799) 30 - 23/32 (780)
Depth inch (mm) 8 - 9/32 (210) 11 - 3/8 (289) Net Weight lb (kg) 20 (9.0) 71 (32) Compressor Type Rotary (1 cylinder)
rolling piston type Motor Type Induction (2-poles) Rated Output W 670
Air Circulation Type Cross-flow Fan Propeller Fan
Material AS + Glass Fiber 20% PP Resin
Motor Type Induction (4-poles) Induction (6-poles)
Input W 49.2 63.0 Rated Output W 15 29 Fan Speed Low rpm Cooling; 780
Heating; 840
Medium rpm Cooling; 920
Heating; 920
High rpm Cooling; 1,030 820
Heating; 1,190
SuperHigh rpm Cooling; 1,190
Heating; 1,190
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue Coat) Fin Type Slit Fin Corrugate Fin Row / Stage (Plate fin configuration, forced draft)
2×15 1×20 FPI 21 17 Size (W × H × L) mm 610 × 315 × 25.4 841 × 508 × 22
Refrigerant Control Device Capillary Tube Refrigeration Oil (cm3) FVC68D (330) Refrigerant (R-410A) g (oz) 970 (34.2) Thermostat Electronic Control — Protection Device Overload Protector Capillary Tube Length mm Cooling; 970, Heating; 610
Flow Rate l/min Cooling; 5.0, Heating; 6.5 Inner Diameter mm Cooling; 1.2, Heating; 1.2
Air Filter Material
Style
P.P.
Honeycomb
Capacity Control Capillary Tube Compressor Capacitor µF, VAC 25 µF, 370VAC Fan Motor Capacitor µF, VAC 1.5 µF, 400VAC 2.0 µF, 450VAC
Specifications are subject to change without notice for further improvement.
7
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Unit CS-W9CKP CU-W9CKP5
Cooling Capacity kW (kcal/h) 2.90 (2,490)
BTU/h 9,890
Heating Capacity kW (kcal/h) 3.14 (2,700)
BTU/h 10,700
Moisture Removal l/h (Pint/h) 1.7 (3.6)
Phase Single
Power Source V 230
Cycle 50
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Indoor Air (Lo) m3/min (cfm) Cooling; 6.8 (240)
Heating; 7.0 (250)
Indoor Air (Me) m3/min (cfm) Cooling; 8.3 (290)
Heating; 8.0 (280)
Indoor Air (Hi) m3/min (cfm) Cooling; 9.9 (350) Cooling; 34.5 (1,220)
Heating; 10.2 (360)
Indoor Air (SHi) m3/min (cfm) Cooling; 10.2 (360)
Heating; 10.2 (360)
dB (A) Cooling; High 36, Low 26 Cooling; High 48
Heating; High 39, Low 26 Heating; High 49
Noise Level
Power level (dB) Cooling; High 49 Cooling; High 63
Heating; High 52 Heating; High 64
Electrical Data Input W Cooling; 850
Heating; 780
Running Current A Cooling; 3.7
Heating; 3.5
EER W/W (BTU/hW) Cooling; 3.41 (11.6) COP W/W (BTU/hW) Heating; 4.03 (13.7) Starting Current A 15.9
Piping Connection Port (Flare piping)
inch inch
G ; Half Union 3/8 L ; Half Union 1/4
G ; 3-way valve 3/8
L ; 2-way valve 1/4
Pipe Size (Flare piping)
inch inch
G ; (gas side) 3/8
L ; (liquid side) 1/4
G ; (gas side) 3/8
L ; (liquid side) 1/4
Drain Hose
Inner diameter mm 12 Length mm 650
Power Cord Length Number of core-wire
m 1.9
3 (1.0 mm
2
)
— —
Dimensions Height inch (mm) 10 - 13/16 (275) 21 - 1/4 (540)
Width inch (mm) 31 - 15/32 (799) 30 - 23/32 (780) Depth inch (mm) 8 - 9/32 (210) 11 - 3/8 (289)
8
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Unit CS-W9CKP CU-W9CKP5
Net Weight lb (kg) 20 (9.0) 73 (33) Compressor Type Rotary (1 cylinder)
rolling piston type Motor Type Induction (2-poles) Rated Output W 780
Air Circulation Type Cross-flow Fan Propeller Fan
Material AS + Glass Fiber 20% PP Resin
Motor Type Induction (4-poles) Induction (6-poles)
Input W 49.2 63.0 Rated Output W 15 29 Fan Speed Low rpm Cooling; 780
Heating; 840
Medium rpm Cooling; 960
Heating; 960
High rpm Cooling; 1,140 820
Heating; 1,230
SuperHigh rpm Cooling; 1,230
Heating; 1,230
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue Coat) Fin Type Slit Fin Corrugate Fin Row / Stage (Plate fin configuration, forced draft)
2 × 15 1 × 20 FPI 21 17 Size (W × H × L) mm 610 × 315 × 25.4 841 × 508 × 22
Refrigerant Control Device Capillary Tube Refrigeration Oil (cm3) FVC68D (330) Refrigerant (R-410A) g (oz) 940 (33.2) Thermostat Electronic Control Protection Device Overload Protector Capillary Tube Length mm Cooling; 970, Heating; 720
Flow Rate l/min Cooling; 5.0, Heating; 7.5 Inner Diameter mm Cooling; 1.2, Heating; 1.3
Air Filter Material
Style
P.P.
Honeycomb
Capacity Control Capillary Tube Compressor Capacitor µF, VAC 30 µF, 370VAC Fan Motor Capacitor µF, VAC 1.5 µF, 400VAC 2.0 µF, 450VAC
Specifications are subject to change without notice for further improvement.
9
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Unit CS-W12CKP CU-W12CKP5
Cooling Capacity kW (kcal/h) 3.74 (3,220)
BTU/h 12,800
Heating Capacity kW (kcal/h) 4.09 (3,520)
BTU/h 14,000
Moisture Removal l/h (Pint/h) 2.2 (4.6)
Phase Single
Power Source V 230
Cycle 50
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Indoor Air (Lo) m3/min (cfm) Cooling; 7.3 (260)
Heating; 7.8 (270)
Indoor Air (Me) m3/min (cfm) Cooling; 9.1 (320)
Heating; 9.1 (320)
Indoor Air (Hi) m3/min (cfm) Cooling; 10.2 (360) Cooling; 33.0 (1,160)
Heating; 10.6 (370)
Indoor Air (SHi) m3/min (cfm) Cooling; 10.6 (370)
Heating; 10.6 (370)
dB (A) Cooling; High 39, Low 29 Cooling; High 49
Heating; High 40, Low 29 Heating; High 49
Noise Level
Power level (dB) Cooling; High 52 Cooling; High 64
Heating; High 53 Heating; High 65
Electrical Data Input kW Cooling; 1.10
Heating; 1.07
Running Current A Cooling; 4.9
Heating; 4.8
EER W/W (BTU/hW) Cooling; 3.40 (11.6) COP W/W (BTU//hW) Heating; 3.82 (13.1) Starting Current A 17.8
Piping Connection Port (Flare piping)
inch inch
G ; Half Union 1/2
L ; Half Union 1/4
G ; 3-way valve 1/2
L ; 2-way valve 1/4
Pipe Size (Flare piping)
inch inch
G ; (gas side) 1/2
L ; (liquid side) 1/4
G ; (gas side) 1/2
L ; (liquid side) 1/4
Drain Hose
Inner diameter mm 12 Length mm 650
Power Cord Length Number of core-wire
m 1.9
3 (1.0 mm
2
)
— —
Dimensions Height inch (mm) 10 - 13/16 (275) 21 - 1/4 (540)
Width inch (mm) 31 - 15/32 (799) 30 - 23/32 (780) Depth inch (mm) 8 - 9/32 (210) 11 - 3/8 (289)
10
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Unit CS-W12CKP CU-W12CKP5
Net Weight lb (kg) 20 (9.0) 77 (35) Compressor Type Rotary (1 cylinder)
rolling piston type Motor Type Induction (2-poles) Rated Output W 830
Air Circulation Type Cross-flow Fan Propeller Fan
Material AS + Glass Fiber 20% PP Resin
Motor Type Induction (4-poles) Induction (6-poles)
Input W 49.2 67.4 Rated Output W 15 33 Fan Speed Low rpm Cooling; 900
Heating; 960
Medium rpm Cooling; 1,120
Heating; 1,120
High rpm Cooling; 1,260 845
Heating; 1,300
SuperHigh rpm Cooling; 1,300
Heating; 1,300
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue Coat) Fin Type Slit Fin Corrugate Fin Row / Stage (Plate fin configuration, forced draft)
2 × 15 2 × 24 FPI 21 17 Size (W × H × L) mm 610 × 315 × 25.4 705.8
735.1
× 504 × 18.9
Refrigerant Control Device Capillary Tube Refrigeration Oil (cm3) FVC68D (330) Refrigerant (R-410A) g (oz) 1,060 (37.4) Thermostat Electronic Control Protection Device Overload Protector Capillary Tube Length mm Cooling; 970, Heating; 590
Flow Rate l/min Cooling; 5.0, Heating; 8.2 Inner Diameter mm Cooling; 1.2, Heating; 1.3
Air Filter Material
Style
P.P.
Honeycomb
Capacity Control Capillary Tube Compressor Capacitor µF, VAC 35 µF, 370VAC Fan Motor Capacitor µF, VAC 1.5 µF, 400VAC 2.0 µF, 450VAC
Specifications are subject to change without notice for further improvement.
11
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
4 Dimensions
12
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
13
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
5 Refrigeration Cycle Diagram
14
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
6 Block Diagram
15
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
7 Wiring Diagram
16
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Cooling in operation according to Remote Control setting.
Time Delay Safety Control (3 minutes)
7 minutes Time Save Control
Starting Current Control
Anti-Freezing Control
If the temperature of the indoor heat exchanger falls continuously below 2°C for 4 minutes or more, the compressor turns off to protect the indoor heat exchanger from freezing. The fan speed setting remains the same.
Compressor will restart again when the indoor heat exchanger temperature rises to 10°C (Recovery).
3 minutes waiting of Time Delay Safety Control is valid for Cooling Operation.
Compressor Reverse Rotation Protection Control
8 Operation Details
8.1. Cooling Mode Operation
When the compressor is stopped by Remote Control, it restarts after 3 minutes when it is turned ON by Remote Control.
When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes.
The compressor will start automatically if it has stopped for 7 minutes even if the room temperature is between the compressor
ON temperature and OFF temperature.
When the compressor outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will operate 1.6 second later.
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor heat exchanger is 2.5°C or less for 2 minutes, compressor will stop and restart automatically. (Time Delay Safety Control is valid)
T = Intake air temperature - Indoor heat exchanger temperature This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
17
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Compressor Protection Control
Automatic Fan Speed Mode
After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and restart automatically. (Time Delay Safety Control is valid).
If the above phenomenon is repeated for 3 times, the compressor will stop totally.
The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch.
When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
18
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Cooling Operation Time Diagram
19
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Quiet Operation Control
(For Cooling Mode or cooling region of Soft Dry Mode)
Purpose of this operation is to provide quite cooling operation compare to normal operation.
When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50).
After that, it goes back to Lo cool (However Quiet LED remains on).
Manual Airflow Direction:-
RPM control during Lo cool
RPM control during Hi & Me cool
Auto Airflow Direction:-
Quiet Mode Operation will stop if:-
Quiet mode button is pressed again.
Stopped by ON/OFF switch.
Timer OFF activates.
Powerful mode button is pressed.
When change mode to Air Circulation mode.
20
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Time Delay Safety Control
Starting Current Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Compressor Protection Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
The operation will be switched on and off for up to 10 minutes ONand 6 minutes OFF. Once Soft Dry operation is turned
off, it stops for 6 minutes.
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Same as Starting Current Control for Cooling Mode operation.
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting is valid during compressor stops.)
Same as Compressor Protection Control for Cooling Mode Operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
Fan speed rotates at Lo- speed.
Deodorizing Control.
21
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Soft Dry Operation Time Diagram
Quiet Operation Control
(For Dry region at Soft Dry Mode)
22
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Heating in operation according to Remote Control setting.
Time Delay Safety Control
30 minutes Time Save Control
Overload Protection Control
(b) Compressor high pressure protection
Compressor Reverse Rotation Protection Control
4-way Valve Control
Outdoor Fan Motor Control
Indoor Fan Motor Control
8.3. Heating Mode Operation
When the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
When the setting temperature is reached during heating operation, the compressor stops and it will not start for 4 minutes.
The compressor will start automatically if it has stopped for 30 minutes even if the room temperature is between the compressor
ON temperature and OFF temperature.
(a) Outdoor Fan Control
If the temperature of the indoor heat exchanger rises to 51°C, Outdoor Fan stops.
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49°C.
If the indoor heat exchanger becomes 65°C or more, the compressor will stop and restart automatically.
(Time Delay Safety Control - 4 minutes waiting).
If the compressor is operating continuously for 5 minutes or longer and temperature difference between intake air and indoor heat exchanger is 5°C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid).
T = Indoor heat exchanger temperature - intake air temperature. This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
4-way valve always ON during Heating operation. (Except Deicing operation)
When the unit is switched to OFFduring Heating operation, 4-way valve stay at Heating position for 5 minutes.
When compressor stops (reaches room temperature), outdoor fan will operate for 30 seconds.
(30 seconds Forced Operation).
When compressor stops (reaches room temperature), indoor fan will stop for 1 minutes, operate for 3 minutes, if still not yet reaches the room temperature, indoor fan Lo- for 40 sec. after that operate at SLo speed.
23
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Hot Start Control
Anti Cold Draft Control
When Heating operation starts, Indoor Fan will not start until the indoor heat exchanger reaches 30°C as diagram shown.
Hot Start is completed when indoor heat exchan ger rises to 39°C or over 4 minutes.
This operation is to prevent the Cold Draft during Heating mode operation.
The operation will start when compressor OFF (Thermo OFF) during Heating operation.
For the first 30 sec. from compressor OFF (Thermo OFF), Indoor fan speed will operate accordingly to the Indoor heat
exchanger temperature as shown below:
After 30 sec. from compressor OFF (thermo OFF), Indoor fan will run at SSLo speed only.
Anti Cold Draft Control will stop when:
Intake temperature < set temperature. (Time Delay Safety Control 4 minutes waiting is valid)
After 30 minutes time saved control.
(refer to next page).
24
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Automatic Fan Speed Mode
Heating Operating Time Diagram
When Automatic Fan Speed is selected at Remote Control during heating operation.
Fan speed rotates in the range of Me SLo according to the heat exchanger temperature.
If use Manual Fan Speed,
at above diagram will operate with setting Fan Speed.
25
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Deicing Control
Deice starts to prevent frosting at outdoor heat exchanger.
Normal Deicing
Deice operations detection commences after 30 minutes of Heating operation starts or 60 minutes after previous deice operation. If the TRS (Thermal Reed Switch) senses the outdoor piping temperature drops to -3°C (TRS CLOSE) or less for 50 sec. continuously during compressor is in operation, deice will start.
(There is no detection during Outdoor Fan stops.)
Overload Deicing
During heating operation, if the outdoor Fan OFF duration (due to overload control) is accumulated up to 60 minutes and after compressor starts for 1 minutes, deicing starts.
Deicing ends when
1. 12 minutes after deicing operation starts;
2. TRS senses the outdoor piping temperature rises to 4°C (TRS OPEN).
3. Deicing will not end immediately as time delay (Td) is valid as shown below.
Once deicing operation starts, it will not end for 60 seconds.
After deicing operation, compressor stops for 30 seconds and 4-way valve stays at cooling position for 10 seconds.
26
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Normal Deicing Time Diagram
Overload Deicing Time Diagram
27
CS-W7CKP CU-W 7CKP5 / CS-W 9CKP CU-W 9CKP5 / CS-W12CKP CU-W12C KP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com
Loading...
+ 60 hidden pages