Ozito CPP-370 User Manual

5 (5)

CONSTANT PRESSURE PUMP

420W

INSTRUCTION MANUAL SPECIFICATIONS

Motor:

420W

Max. Flow Rate:

1,900 l/h

Max. Lift:

0m

Max. Head:

33m

Inlet:

25.4mm (1”BSP) Female

Outlet:

25.4mm (1”BSP) Male

Water Temp.:

1oC to 35ºC

IP Rating:

IPX4

Weight:

6.95kg

ozito.com.au

WHAT’S IN THE BOX

Constant Pressure Pump

Teflon Tape

CPP-370

WARRANTY

IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE:

Australia 1800 069 486

New Zealand 0508 069 486

The benefits provided under this warranty are in addition

to other rights and remedies which are available to you at law.

Our goods come with guarantees that cannot be excluded

at law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Generally you will be responsible for all costs associated with a claim under this warranty, however, where you have suffered any additional direct loss as a result of a defective product you

may be able to claim such expenses by contacting our customer service helpline above.

TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL

AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE.

3 YEAR REPLACEMENT WARRANTY

Your product is guaranteed for a period of 36 months from the original date of purchase. If a product is defective it will be replaced in accordance with the terms of this warranty.

Warranty excludes consumable parts, for example: O-rings, bearing, seals gaskets.

WARNING

The following actions will result in the warranty being void.

If the tool has been operated on a supply voltage other than that specified on the tool.

If the tool shows signs of damage or defects caused by or resulting from abuse, accidents or alterations.

Failure to perform maintenance as set out within the instruction manual.

If the tool is disassembled or tampered with in any way.

Professional, industrial or high frequency use.

OZITO Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.

1017

Ozito CPP-370 User Manual

KNOW YOUR PRODUCT

CONSTANT PRESSURE PUMP

1.

Discharge outlet

4.

Pump body

2.

Pump control unit

5.

Suction inlet

3.

Control unit union

6.

Base

1

2

3

4

5

6

7

ACCESSORIES

7. Teflon tape

ONLINE MANUAL

Scan this QR Code with your mobile device to take you to the online manual.

SETUP & PREPARATION

1. SETTING UP

WARNING!: ENSURE THE PUMP IS DISCONNECTED FROM THE POWER SUPPLY BEFORE PERFORMING

ANY OF THE FOLLOWING OPERATIONS.

This constant pressure pump is designed for pumping clean water in the house and garden. It is ideal for providing domestic water supply to laundries, toilets and outdoor taps, combined with a trigger nozzle and hose for garden watering and washing cars.

Your pump requires no assembly before use other than the connection of suitable inlet/outlet hose or pipe adaptors (not included).

Positioning the pump

The device must be placed on a horizontal, level surface that is sufficiently capable of supporting the total weight of the device when filled with water.

Four mounting recesses allow for fixing the base to the mounting surface (bolts not supplied).

FIRM BASE

Note: The installation site must be well ventilated and protected from the effects of weather.

Note: When operating indoors you must ensure that there is a drain in the floor or a mechanism to prevent leakage.

2. SUCTION INLET

Connecting to the suction inlet

The inlet allows for a 25.4mm (1”) supply line to be connected.

Note: The Ozito TPIK-025 Tank to pump installation kit is available from Bunnings stores and may assist in your installation.

1.Teflon tape is required on threads to ensure a water tight seal and prevent any leakage.

Wind Teflon clockwise on fittings.

2. Remove the plastic protection cover from the suction inlet.

3. Insert 1” male threaded adaptor

(not included). Tighten firmly with a spanner (not included).

4. Securely attach the input hose or pipe (not included) to the other end of the adaptor. Ensure you have the correct diameter hose or pipe that is compatible with your water drawing source.

Note: The suction pipe should have an internal diameter of at least 25.4mm (1”); it must be kink resistant

and suitable for pump use. Ensure the input hose or pipe is not restricted in any way.

3. DISCHARGE OUTLET

Connecting to the discharge outlet

The outlet allows for a 25.4mm (1”) delivery line to be connected and is capable of a maximum head of 33m

1. Remove the plastic protection cover from the discharge outlet.

2.Wrap the discharge outlet with

Teflon tape.

3. Insert a 1” female threaded adaptor (not included).

4. Securely attach the output hose or pipe (not included) to the other end of the adaptor. Ensure you have the correct diameter hose or pipe that is compatible with your water discharge application.

Note: The discharge hose or pipe you are using must have a minimum diameter of 19mm (3/4’’).

Note: Ensure the discharge hose or pipe is not restricted in any way and nothing is obstructing the hose or pipe when the pump is in operation.

WARNING!: RISK OF INJURY! IF THE COMPONENTS ARE NOT COMPRESSION-PROOF OR IF THEY ARE IMPROPERLY INSTALLED, THE PRESSURE LINE COULD

BURST DURING OPERATION.

Loading...
+ 5 hidden pages