Omron NT11, NT21 DATASHEET

Programmable Terminals
NT11/NT21
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Note: Do not use this document to operate the Unit.
OMRON Corporation
FA Systems Division H.Q.
66 Matsumoto Mishima-city, Shizuoka 411-8511 Japan Tel: (81)55-977-9181 Fax: (81)55-977-9045
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue, #11-01, UE Square, Singapore 239920 Tel: (65)6835-3011/Fax: (65)6835-2711
This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product.
The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use. Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system.
Authorized Distributor:
Printed in Japan 1003-0.5M
NT11
NT21
Compact Size, High Performance
NT
Superb functionality with a compact screen size
NT
11NT11
Effective display area 117 x 63 mm
Up to 3,999 screens
Concentrated functionality
Mathematical functions
NT20S/NT31 data compatibility
Upgraded NT Support Tool version (-EV4.7)
•Shares I/O comment data with CX-Programmer
•Symbol Manager previews
•Copy image library window data
•Individual editing of grouped parts
•Windows XP supported
High-speed NT Links
Memory Link
Supports RS-232C/422 Adapter (connector)
Two RS-232C ports
Supports Memory Units
31 functional parts
•Recipes
•Alarm lists/histories
•Image library
•Trend graphs
•Analog meters
NT21
Bar Code Reader function
Programming Console function
Printout of Production Status
Data such as the production status and production results can be printed out, leaving a record on paper which can be used as a daily report. (The NT11S has a printer port. One screen only is printed.)
Screen
Line 1
Line 2
Line 3
Plan
200
150
350
Prod.
200
140
350
Integral Numeric Key Pad
The display, numeric keys, and function keys are all integrated into the front panel, which is convenient for designers. The key layout is ergonomically designed for ease of use.
High-speed Host Link
Bar Graphs can be Displayed
Bar graph displays allow the progress of processes to be checked at a glance. (The bars are oriented horizontally.)
Advantages From
Advantages From
the Standpoint of Maintenance,
the Standpoint of Maintenance,
Password Screens for Security
Password screens cannot be accessed unless the correct password is entered. This means that the operations that can be performed can be restricted according to the operator.
High-speed Host Link
Full Area Access to CS1/CJ1
Simplified Ladder Programming
Long-lived Backlight
NT11
Fully Compatible with NT11S
Password Screens
Up to 115,200 bps supported between CS1/CJ1 PLCs.
Key Titles can be Marked on the Function Key Sheet
Key titles can be marked on the function key sheet in accordance with the applications of the keys: the sheet can be taken out from the side face of the terminal. The front panel of the terminal has a water-withstanding construction.
Example key titles:
F1 RUNF2 AUTF3 MAN.
F4 STOP
Long-lived Backlight
Since LEDs are used for the backlight, it is very long-lived and rarely needs to be changed.
Display History Record Helps in Analysis of Machine Faults
When the display history record function is set as a screen attribute, the time, the screen number, and a comment are recorded in the terminal's memory every time the relevant screen is displayed. This display history can be printed by issuing a print instruction from the host, and is useful for machine fault analysis.
Example printout
Time
No.
11/01-10:00
1
11/07-15:33
2
11/11-13:56
3
11/14-09:12
4
Screen No
1
15
19
5
Screen Comment
LINE ERROR
MOTOR ERROR
COMPRESSER ERROR
MOTOR ERROR
Conforms to NEMA4 and IP65
2 3
Loading...
+ 2 hidden pages