Programmable Terminals
NT11/NT21
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and
workmanship for a period of one year (or other period if specified) from date of sale by
OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED,
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER
OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE
REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH
THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the
product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Note: Do not use this document to operate the Unit.
OMRON Corporation
FA Systems Division H.Q.
66 Matsumoto
Mishima-city, Shizuoka 411-8511
Japan
Tel: (81)55-977-9181
Fax: (81)55-977-9045
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
Singapore 239920
Tel: (65)6835-3011/Fax: (65)6835-2711
This catalog mainly provides information that is necessary for selecting suitable models, and
does not contain precautions for correct use. Always read the precautions and other
required information provided in product operation manuals before using the product.
The application examples provided in this catalog are for reference only. Check functions
and safety of the equipment before use.
Never use the products for any application requiring special safety requirements, such as
nuclear energy control systems, railroad systems, aviation systems, medical equipment,
amusement machines, vehicles, safety equipment, or other application involving serious risk
to life or property, without ensuring that the system as a whole has been designed to
address the risks, and that the OMRON products are properly rated and installed for the
intended use within the overall equipment or system.
Authorized Distributor:
Note: Specifications subject to change without notice. Cat. No. V071-E1-02
Printed in Japan
1003-0.5M
NT11
NT21
Compact Size, High Performance
Superb functionality with a compact screen size
NT
11NT11
Effective display area
117 x 63 mm
Up to 3,999 screens
Concentrated functionality
Mathematical
functions
NT20S/NT31
data compatibility
Upgraded NT Support Tool
version (-EV4.7)
•Shares I/O comment data
with CX-Programmer
•Symbol Manager previews
•Copy image library window data
•Individual editing of grouped parts
•Windows XP supported
High-speed NT Links
Memory Link
Supports RS-232C/422
Adapter (connector)
Two RS-232C ports
Supports Memory Units
31 functional parts
•Recipes
•Alarm lists/histories
•Image library
•Trend graphs
•Analog meters
NT21
Bar Code Reader
function
Programming Console
function
Printout of Production Status
Data such as the production status and production results
can be printed out, leaving a record on paper which can be
used as a daily report.
(The NT11S has a printer port. One screen only is printed.)
Screen
Line 1
Line 2
Line 3
Plan
200
150
350
Prod.
200
140
350
Integral Numeric Key Pad
The display, numeric keys, and function keys are all
integrated into the front panel, which is convenient for
designers. The key layout is ergonomically designed for
ease of use.
High-speed Host Link
Bar Graphs can be Displayed
Bar graph displays allow the progress of processes to be
checked at a glance.
(The bars are oriented horizontally.)
Advantages From
Advantages From
the Standpoint of Maintenance,
the Standpoint of Maintenance,
Password Screens for Security
Password screens cannot be accessed unless the correct
password is entered. This means that the operations that
can be performed can be restricted according to the
operator.
High-speed Host Link
Full Area Access
to CS1/CJ1
Simplified Ladder Programming
Long-lived Backlight
NT11
Fully Compatible
with NT11S
Password
Screens
Up to 115,200 bps supported between CS1/CJ1 PLCs.
Key Titles can be Marked on the Function
Key Sheet
Key titles can be marked on the function key sheet in
accordance with the applications of the keys: the sheet can
be taken out from the side face of the terminal.
The front panel of the terminal has a water-withstanding
construction.
Example key titles:
F1
RUNF2 AUTF3 MAN.
F4
STOP
Long-lived Backlight
Since LEDs are used for the backlight, it is very long-lived
and rarely needs to be changed.
Display History Record Helps in Analysis of
Machine Faults
When the display history record function is set as a screen
attribute, the time, the screen number, and a comment are
recorded in the terminal's memory every time the relevant
screen is displayed. This display history can be printed by
issuing a print instruction from the host, and is useful for
machine fault analysis.
Example printout
Time
No.
11/01-10:00
1
11/07-15:33
2
11/11-13:56
3
11/14-09:12
4
Screen No
1
15
19
5
Screen Comment
LINE ERROR
MOTOR ERROR
COMPRESSER ERROR
MOTOR ERROR
Conforms to NEMA4 and IP65
2 3