Versatile and Function-filled Miniature Power
Relay for Sequence Control and Power
Switching Applications
• Models with lockable test buttons now available.
• Many variations possible through a selection of operation indicators (mechanical and LED indicators), lockable test button,
built-in diode and CR (surge suppression), bifurcated contacts,
etc.
• Arc barrier standard on 4-pole Relays.
• Dielectric strength: 2,000 VAC (coil to contact)
• Environment-friendly cadmium-free contacts.
• Safety standard approvals obtained.
• Wide range of Sockets (PY, PYF Series) and optional parts are
available.
• Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A
• Provided with nameplate.
Ordering Information
LR
■ Relays
Standard Coil Polarity
TypeContact formPlug-in socket/Solder terminalsWithout LED indicator
AC6 V*214.1 mA183 mA12.2 Ω0.04 H0.08 H80% max.30% min.110%1.0 to 1.2 VA
12 V106.5 mA91 mA46 Ω0.17 H0.33 H
24 V53.8 mA46 mA180 Ω0.69 H1.30 H
48/50 V*24.7/
110/120 V9.9/10.8 mA8.4/9.2 mA4,430 Ω19.20 H32.1 H0.9 to 1.1 VA
220/240 V4.8/5.3 mA4.2/4.6 mA18,790 Ω83.50 H136.4 H
DC6 V*151 mA39.8 Ω0.17 H0.33 H10% min.0.9 W
12 V75 mA160 Ω0.73 H1.37 H
24 V37.7 mA636 Ω3.20 H5.72 H
48 V*18.8 mA2,560 Ω10.60 H21.0 H
100/110 V9.0/9.9 mA11,100 Ω45.60 H86.2 H
25.7 mA
21.1/
22.0 mA
resistance
788 Ω3.22 H5.66 H
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder
resistor if required.
5. Rated voltage denoted by “*” will be manufactured upon request. Ask your OMRON representative.
Coil inductance
(reference value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
(60 Hz)
(60 Hz)
2General-purpose Relay MY New model
■ Contact Ratings
Item2-pole4-pole4-pole (bifurcated)
Resistive load
(cosφ = 1)
Rated load5A, 250 VAC
Carry current10 A (see note)5 A (see note)
Max. switching
voltage
Max. switching
current
Max. switching
power
Failure rate
(reference value)
5A, 30 VDC
250 VAC
125 VDC
10 A5 A
2,500 VA
300 W
5 VDC, 1 mA1 VDC, 1 mA1 VDC, 100 µA
Inductive load
(cosφ = 0.4, L/R = 7 ms)
2A, 250 VAC
2 A, 30 VDC
1,250 VA
300 W
Resistive load
(cosφ = 1)
3 A, 250 VAC
3 A, 30 VDC
250 VAC
125 VDC
1,250 VA
150 W
Inductive load
(cosφ = 0.4, L/R = 7 ms)
0.8 A, 250 VAC
1.5 A, 30 VDC
500 VA
150 W
Resistive load
(cosφ = 1)
3 A, 250 VAC
3 A, 30 VDC
1,250 VA
150 W
(cosφ = 0.4, L/R = 7 ms)
0.8 A, 250 VAC
1.5 A, 30 VDC
500 VA
150 W
Note: Don’t exceed the carry current of a Socket in use. Please see page 10.
■ Characteristics
ItemAll Relays
Contact resistance100 mΩ max.
Operate time 20 ms max.
Release time20 ms max.
Max. operating frequencyMechanical: 18,000 operations/hr
Insulation resistance1,000 MΩ min. (at 500 VDC)
Dielectric strength2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)
Vibration resistanceDestruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance
EnduranceSee the following table.
Ambient temperatureOperating: –55°C to 70°C (with no icing)
Ambient humidityOperating: 5% to 85%
WeightApprox. 35 g
Note: The values given above are initial values.
Electrical:1,800 operations/hr (under rated load)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 200 m/s
2
2
Inductive load
■ Endurance Characteristics
PoleMechanical life (at 18,000 operations/hr)Electrical life
2-poleAC:50,000,000 operations min.
4-pole200,000 operations min.
DC:100,000,000 operations min.
4-pole (bifurcated)20,000,000 operations min.100,000 operations min.