Before using the unit
Introduction
Thank you for purchasing the OMRON M1 Compact Upper Arm Blood
Pressure Monitor.
The OMRON M1 Compact is a manual inflation blood pressure monitor,
operating on the oscillometric principle. It measures your blood
pressure and pulse rate simply and quickly.
The unit also stores up to 30 measurements in memory.
Please read this instruction manual thoroughly before using
the unit. For specific information about your own blood
pressure, CONSULT YOUR DOCTOR.
EN
3
HEM-4022-IM_RU.book 4 ページ 2012年1月6日 金曜日 午後2時39分
Important Safety Information
Consult your doctor during pregnancy, arrhythmia and arteriosclerosis.
Please read this section carefully before using the unit.
Warning:
Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
(General Usage)
• Always consult your doctor. Self-diagnosis of measurement results
and self-treatment are dangerous.
• People with severe blood flow problems, or blood disorders, should
consult a doctor before using the unit. Cuff inflation can cause internal
bleeding.
(Battery Usage)
• If battery fluid should get in your eyes, immediately rinse with plenty of
clean water. Consult a doctor immediately.
Caution:
Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury to the user or patient or damage to the
equipment or other property.
(General Usage)
• Do not leave the unit unattended with infants or persons who cannot
express their consent.
• Do not use the unit for any purpose other than measuring blood
pressure.
• Do not disassemble the unit or arm cuff.
• Do not inflate the arm cuff over 299 mmHg.
• Do not use a mobile phone, or other devices that emit electromagnetic
fields, near the unit. This may result in incorrect operation of the unit.
• Do not operate unit in a moving vehicle (car, airplane).
4
HEM-4022-IM_RU.book 5 ページ 2012年1月6日 金曜日 午後2時39分
Important Safety Information
(Battery Usage)
• If battery fluid should get on your skin or clothing, immediately rinse
with plenty of clean water.
• Use only four “AAA” alkaline batteries with this unit. Do not use other
types of batteries.
• Do not insert the batteries with their polarities incorrectly aligned.
• Replace old batteries with new ones immediately. Replace all four
batteries at the same time.
• Remove the batteries if the unit will not be used for three months or
more.
• Do not use new and used batteries together.
General Safety Precautions
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Do not apply strong shocks and vibrations to or drop the unit.
• Do not take measurements after bathing, drinking alcohol, smoking,
exercising or eating.
• Do not wash the arm cuff or immerse it in water.
• Read and follow the “Important information regarding Electro
Magnetic Compatibility (EMC)” in the Technical Data Section.
• Read and follow the “Correct Disposal of This Product” in the
Technical Data Section when disposing of the device and any used
accessories or optional parts.
Save these instructions for future reference.
EN
5
B
A
C
D
E
GF
HEM-4022-IM_RU.book 6 ページ 2012年1月6日 金曜日 午後2時39分
1.Overview
1. Overview
Main unit
A. Display
B. I/O button (Power switch)
C. Air connector for cuff and
inflation bulb
D. M (Memory) button
E. Battery compartment
Arm Cuff
F. A rm c u f f
(Medium cuff: arm circumference 22-32 cm)
G. Ai r T u b e
6
I
J
H
K
O
Q
R
L
M
P
S
N
HEM-4022-IM_RU.book 7 ページ 2012年1月6日 金曜日 午後2時39分
1.Overview
Inflation Bulb
H. Air Release Button
I. Air Tube
J. Air Inflation Bulb
Display
K. Systolic blood pressure
L. Diastolic blood pressure
M. Memory symbol
Displayed when viewing values
stored in memory
N. Battery low symbol
O. Heartbeat symbol
1. Flashes during measurement
2. If flashing after measurement
completed or when viewing
results stored in the memory,
indicates blood pressure out of
recommended range*
EN
P. Pulse display
Q. Deflation symbol
R. Reinflation symbol
S. Irregular heartbeat symbol
* Note: If your systolic or diastolic
pressure is outside the
standard range (above
135/85 mmHg) the Heartbeat
symbol () will blink.
Please refer to Chapter 3.3.7.
7
UT
HEM-4022-IM_RU.book 8 ページ 2012年1月6日 金曜日 午後2時39分
1.Overview
Package contents (others)
T. Storage case
U. Four “AAA” alkaline (LR03)
batteries
8
• Instruction manual
• Guarantee card
• Blood pressure pass
HEM-4022-IM_RU.book 9 ページ 2012年1月6日 金曜日 午後2時39分
2.Preparation
2. Preparation
Installing/Replacing the Batteries
2.1
1.Turn the main unit upside down.
2.Slide the battery cover in the
direction of the arrow while
pressing the ribbed part of the
cover.
3.Install or replace four “AAA”
size batteries so that the
+ (positive) and - (negative)
polarities match the polarities
indicated on the battery
compartment.
4.Put the battery cover back in place.
Slide the battery cover as indicated, until it clicks into place.
EN
Note: The measurement values continue to be stored in
memory even after the batteries are replaced.
9
HEM-4022-IM_RU.book 10 ページ 2012年1月6日 金曜日 午後2時39分
2.Preparation
Battery Life & Replacement
If the battery low symbol () appears on the display, replace all four
batteries at the same time.
- When the battery low symbol () starts to blink, you will still be
able to use the unit for a short while. You should replace the
batteries with new ones ahead of time.
- When the symbol () remains lit, the batteries are exhausted. You
should replace the batteries with new ones at once.
• Remove the batteries if the unit will not be used for three months or
more.
• Dispose of batteries according to applicable local regulations.
Four new “AAA” alkaline batteries will last for approximately 1500
measurements, when used to take two measurements a day.
Since the supplied batteries are for monitoring use only, they may have
a shorter life and not last for 1500 measurements.
10
Correct
Posture
Remove tight fitting clothing from
your upper arm, and any thick
clothing such as a sweater.
Do not place the cuff over thick
clothes and do not roll up your
sleeve if it is too tight.
Sit upright
with your
back straight.
Place your arm on a table so
that the cuff will be at the same
level as your heart.
The gap between the
chair and the top of the
table should be between
25cm to 30cm.
HEM-4022-IM_RU.book 11 ページ 2012年1月6日 金曜日 午後2時39分
Operating instructions
3. Using the Unit
3.1
Correct posture during measurement is necessary to get accurate
results.
Notes:
• Measurements should be taken in a quiet place and you should be in
a relaxed, seated position. Make sure that the room is not too hot or
too cold.
• Avoid eating, drinking alcohol, smoking, or exercising for at least 30
minutes before taking a measurement.
• Do not move or talk during measurement.
3.Using the Unit
How to Sit Correctly When Taking a Measurement
EN
11
Incorrect Posture
These situations could lead to higher blood pressure
values due to strain or the arm cuff being lower than the
heart.
If the arm cuff is at a lower position than your heart use
cushions etc., to adjust the height of your arm.
• Arched back (leaning forwards)
• Sitting cross-legged
• Sitting on a sofa or at a low table
so that you tend to lean forward
HEM-4022-IM_RU.book 12 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
Note: You can take a measurement on either your left or right arm. The
blood pressure can differ between the right arm and the left arm
and therefore also the measured blood pressure values can be
different. Omron recommends to always use the same arm for
measurement. If the values between the two arms differ
substantially, please check with your physician which arm to use
for your measurement.
12
HEM-4022-IM_RU.book 13 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
3.2
Applying the Arm Cuff
You can wrap the cuff either on your right or left arm.
• Remove tight-fitting clothing
from your upper arm.
• Do not place the cuff over
thick clothes and do not roll
up your sleeve if it is too
tight.
• You can take a measurement
on either your left or right
arm. The blood pressure can
differ between the right arm and the left arm and therefore
also the measured blood pressure values can be different.
Omron recommends to always use the same arm for
measurement. If the values between the two arms differ
substantially, please check with your doctor which arm to
use for your measurement.
1.Connect the air tube of the arm cuff and the inflation bulb to
their respective air connectors.
EN
13
1) The air tube should run
down the inside of your
forearm and be in line with
your middle finger.
2) The bottom of the cuff
should be approximately 1
to 2 cm above your elbow.
3) Apply the cuff to your
upper arm so that the
coloured marker (blue
arrow under tube) is
centered on the middle of
your inner arm and points
down the inside of the
arm.
HEM-4022-IM_RU.book 14 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
2.Put your left arm through the cuff
loop.
Note: If the cuff is not assembled,
pass the end of the cuff
furthest from the tubing
through the metal D-ring to
form a loop. The smooth
cloth should be on the inside
of the cuff loop.
3.Position the arm correctly.
14
1 to 2 cm
HEM-4022-IM_RU.book 15 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
Taking measurements on the right arm
Apply the cuff so that the
air tube is at the side of
your elbow.
• Be careful not to rest
your arm on the air
tube, or otherwise
restrict the flow of air to
the cuff.
• The cuff should be 1 to
2 cm above the elbow.
4.When the cuff is positioned correctly, close the fabric fastener
FIRMLY.
EN
15
HEM-4022-IM_RU.book 16 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
3.3
Taking a Reading
1.Preparation
1) Press the air release button to release any air in the arm
cuff.
2) Press the I/O button to turn the unit on.
3) All items in the display will be displayed briefly.
4) The deflation symbol will flash.
5) Finally, the heartbeat symbol will appear and 0 is
displayed.
Note: If the deflation symbol does not disappear soon, press
the air release button to release any air in the arm cuff.
2.Pump the inflation bulb to inflate the arm cuff.
1) Inflate the cuff until it is 30 to
40 mmHg above your expected
systolic blood pressure value.
16
ex) If your expected blood
pressure is around 140mmHg,
inflate the arm cuff to between
170 and 180 mmHg. Inflate the
cuff rapidly so that the pressure
is reached in about five seconds.
2) When the desired pressure has been achieved, release
the inflation bulb. Remain still and do not talk.
HEM-4022-IM_RU.book 17 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
Notes:
• If the reinflation symbol () appears, squeeze the inflation
bulb to re-inflate the arm cuff.
• Do not inflate the arm cuff more than necessary.
3.Measurement starts.
Measurement starts
automatically after you stop
inflating the arm cuff. Decreasing
numbers appear on the display
and the heartbeat symbol
flashes.
Remain still and do not talk
during measurement.
Note: To cancel a measurement, press the I/O button to turn
off the unit and press the air release button to release
the air in the arm cuff.
4.Measurement ends.
When the measurement is finished,
the deflation symbol flashes on the
display. Blood pressure and pulse
rate values are displayed.
EN
Press the air release button to
release the air in the arm cuff until
the deflation symbol is no longer
displayed.
17
HEM-4022-IM_RU.book 18 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
5.Check the measurement
results.
The unit automatically stores
blood pressure and pulse rate
into its memory, Refer to “3.4
Using the Memory Function”.
Note: Wait 2-3 minutes before taking another blood pressure
measurement. Waiting between readings allows the
arteries to return to the condition prior to taking the
blood pressure measurement.
Warning:
Self-diagnosis of measured results and treatment are
dangerous. Please follow the instructions of your doctor.
Common Causes of Inaccurate Results
during measurement.
Note: If the arm cuff is at a lower position
than your heart use cushions etc., to
adjust the height of your arm.
Systolic blood
pressure
Diastolic blood
pressure
Pulse display
Leaning forwards.Arm cuff is too loose. Movement or talking
6.Undo the fastener and remove the arm cuff.
7.Press the I/O button to turn the unit off.
Note: If you forget to turn the unit off, it will automatically shut
itself off after five minutes.
18
HEM-4022-IM_RU.book 19 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
Important:
• If your systolic or diastolic pressure is outside the
standard range, the heartbeat symbol will blink when
the measurement result is displayed.
Recent research suggests that the following values
can be used as a guide to high blood pressure for
measurements taken at home.
Systolic Blood PressureAbove 135 mmHg
Diastolic Blood Pressure Above 85 mmHg
This criteria is for home blood pressure measurement.
For professional office blood pressure measurement criteria, please
refer to Chapter 9 “Some Useful Information about Blood Pressure”
• Your blood pressure monitor includes an irregular
heartbeat feature. Irregular heartbeats can influence
the results of the measurement. The irregular
heartbeat algorithm automatically determines if the
measurement is usable or needs to be repeated. If
the measurement results are affected by irregular
heartbeats but the result is valid, the result is shown
together with the irregular heartbeat symbol (). If
the irregular heartbeats cause the measurement to be invalid, no
result is shown. If the irregular heartbeat symbol () is shown after
you have taken a measurement, repeat the measurement. If the
irregular heartbeat symbol () is shown frequently, please make
your doctor aware of it.
EN
19
Normal Heartbeat
HEM-4022-IM_RU.book 20 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
What is Irregular Heartbeat?
An irregular heartbeat is a
heartbeat rhythm that varies by
more than 25% from the
average heartbeat rhythm
detected while the unit is
measuring the systolic and
diastolic blood pressure.
If such an irregular rhythm is
detected more than twice
during measurement, the
Blood pressure
Blood pressure
Pulse
Irregular Heartbeat
Pulse
Short
Long
irregular heartbeat symbol () appears on the symbol when the
measurement results are displayed.
What is Arrhythmia?
A heartbeat is stimulated by electrical signals that cause the heart to
contract.
Arrhythmia is a condition where the heartbeat rhythm is abnormal due
to flaws in the bio-electrical system that drives the heartbeat. Typical
symptoms are skipped heartbeats, premature contraction, an
abnormally rapid (tachycardia) or slow (bradycardia) pulse. This can be
caused by heart disease, aging, physical predisposition, stress, lack of
sleep, fatigue etc. Arrhythmia can only be diagnosed by a doctor
through a special examination.
Whether the appearance of the irregular heartbeat symbol () in the
results indicates arrhythmia or not can only be determined by an
examination and diagnosis by your doctor.
Warning:
If the irregular heartbeat symbol () is shown frequently, please
make your doctor aware of it. Conducting self-diagnosis and
treatment based on measurement results is dangerous. Be sure to
follow the instructions of your doctor.
20
HEM-4022-IM_RU.book 21 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
3.4
Using the Memory Function
The unit automatically stores up to 30 sets of measurement values
(blood pressure and pulse rate). When 30 sets of measurement values
are stored, the oldest record is deleted to save the most recent values.
1.Press the I/O button to turn the
power on.
2.When the heartbeat symbol
appears on the display, press the
M button.
The result from the most recent
measurement is displayed.
Note: If there are no measurements results stored
in memory, the screen to the right is
displayed.
EN
Notes: If your systolic or diastolic
pressure is outside the
standard range, the
heartbeat symbol will blink
when the measurement
result is displayed. Refer to
section 3.3.
21
HEM-4022-IM_RU.book 22 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
3.Press the M button
repeatedly to cycle through
the previous measurement
results.
Keep the button pressed
down to cycle rapidly
through the previous results.
If the irregular heartbeat symbol was displayed after a
measurement, it will also be stored in the memory with the
result of that measurement.
4.Press the I/O button to turn the unit off.
Note: If you forget to turn the unit off, it will automatically shut
itself off after five minutes.
22
1
2
HEM-4022-IM_RU.book 23 ページ 2012年1月6日 金曜日 午後2時39分
3.Using the Unit
To Delete All the Values Stored in Memory
You cannot delete individual stored readings, all the readings in the unit
will be deleted.
1.Press the l/O button to turn the unit on.
2.When the heartbeat symbol ()
appears on the display, first press
the M button. Then while holding it
down, press the I/O button
simultaneously for about 2-3
seconds. All readings will then be
deleted.
Important: Be careful not to press
the I/O button first. If
the I/O button is
pressed first, the
monitor is shut off.
3.Press the I/O button to turn the unit off.
Note: If you forget to turn the unit off, it will automatically shut
itself off after five minutes.
EN
23