Omron LY DATASHEET

General-purpose Relay
s
LY
A Miniature Power Relay
• Equipped with arc barrier.
• Dielectric strength: 2,000 V.
• Single-pole and double-pole models are applicable to operating coils with ratings of 100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC, or 100/110 VDC).
• Three-pole and four-pole models are applicable to operating coils with ratings of 100/110 VAC, 200/220 VAC, or 100/110 VDC).
Ordering Information
Open Relays
Relays
Electromechanical
LR
Type Contact form
Standard SPDT LY1 LY1N LY1-0 LY1F
DPDT LY2 LY2N LY2-0 LY2F DPDT (bifurcated) LY2Z LY2ZN LY2Z-0 LY2ZF 3PDT LY3 LY3N LY3-0 LY3F 4PDT LY4 LY4N LY4-0 LY4F
With built-in diode (DC only)
With built-in CR (AC only)
Note: 1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.
Example: LY2, 6 VAC
2. Relays with #187 quick connect terminals are also available with SPDT and DPDT contact. Ask your OMRON representative for details.
3. SEV models are standard Relays excluding DPDT (bifurcated) models.
4. VDE- or LR- qualifying Relays must be specified when ordering.
SPDT LY1-D LY1N-D2 --- --­DPDT LY2-D LY2N-D2 --- --­DPDT (bifurcated) LY2Z-D LY2ZN-D2 --- --­3PDT LY3-D --- --- --­4PDT LY4-D LY4N-D2 --- --­SPDT --- --- --- --­DPDT LY2-CR LY2N-CR --- --­DPDT (bifurcated) LY2Z-CR LY2ZN-CR --- ---
Plug-in/solder
terminals
Rated coil voltage
Plug-in/solder
terminals with LED
indicator
PCB terminal
Upper-mounting
Plug-in/solder
terminals
General-purpose Relay LY A-31
Accessories (Order Separately)
Sockets
Poles Front-connecting Socket Back-connecting Socket
DIN track/screw terminals Plug-in/solder terminals Wrapping terminals PCB terminals 1 or 2 PTF08A-E, PTF08A PT08 PT08QN PT08-0 3 PTF11A PT11 PT11QN PT11-0 4 PTF14A-E, PTF14A PT14 PT14QN PT14-0
Note: 1. For PTF08-E and PTF14A-E, see “Track Mounted Socket.”
2. PTF@A (-E) Sockets have met UL and CSA standards: UL 508/CSA C22.2.
Mounting Plates for Sockets
Socket model For 1 Socket For 10 Sockets For 12 Sockets For 18 Sockets
PT08 PT08QN
PT11 PT11QN
PT14 PT14QN
Socket-Hold-down Clip Pairings
Relay type Poles Front-connecting Sockets Back-connecting Sockets
Standard, bifurcated contacts oper­ation indicator, built-in diode
CR circuit 2 PTF08A-E, PTF08A Y92H-3 PT08(QN), PT08-0 PYC-1
PYP-1 --- --- PYP-18
PTP-1-3 --- PTP-12 ---
PTP-1 PTP-10 --- ---
Socket model Clip model Socket model Clip model
1, 2 PTF08A-E, PTF08A PYC-A1 PT08(QN), PT08-0 PYC-P 3 PTF11A PT11(QN), PT11-0 4 PTF14A-E, PTF14A PT14(QN), PT14-0
Specifications
Coil Ratings
Single- and Double-pole Relays
Rated voltage Rated current Coil
resistance
50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage
AC 6 V 214.1 mA 183 mA 12.2 0.04 H 0.08 H 80% max. 30% min. 110% 1.0 to 1.2 VA
12 V 106.5 mA 91 mA 46 0.17 H 0.33 H 24 V 53.8 mA 46 mA 180 0.69 H 1.30 H 50 V 25.7 mA 22 mA 788 3.22 H 5.66 H 100/110 V 11.7/12.9 mA 10/11 mA 3,750 14.54 H 24.6 H 0.9 to 1 VA 110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 19.20 H 32.1 H 200/220 V 6.2/6.8 mA 5.3/5.8 mA 12,950 54.75 H 94.07 H 220/240 V 4.8/5.3 mA 4.2/4.6 mA 18,790 83.50 H 136.40 H
DC 6 V 150 mA 40 0.16 H 0.33 H 10% min. 0.9 W
12 V 75 mA 160 0.73 H 1.37 H 24 V 36.9 mA 650 3.20 H 5.72 H 48 V 18.5 mA 2,600 10.6 H 21.0 H 100/110 V 9.1/10 mA 11,000 45.6 H 86.2 H
Note: See notes on the bottom of next page.
Coil inductance
(reference value)
Must operate voltage
Must release voltage
Max.
voltage
Power consum. (approx.)
(60 Hz)
(60 Hz)
A-32 General-purpose Relay LY
Three-pole Relays
Rated voltage Rated current Coil
resistance
50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage
AC 6 V 310 mA 270 mA 6.7 0.03 H 0.05 H 80% max. 30% min. 110% 1.6 to 2.0 VA
12 V 159 mA 134 mA 24 0.12 H 0.21 H 24 V 80 mA 67 mA 100 0.44 H 0.79 H 50 V 38 mA 33 mA 410 2.24 H 3.87 H 100/110 V 14.1/16 mA 12.4/13.7 mA 2,300 10.5 H 18.5 H 200/220 V 9.0/10.0 mA 7.7/8.5 mA 8,650 34.8 H 59.5 H
DC 6 V 234 mA 25.7 0.11 H 0.21 H 10% min. 1.4 W
12 V 112 mA 107 0.45 H 0.98 H 24 V 58.6 mA 410 1.89 H 3.87 H 48 V 28.2 mA 1,700 8.53 H 13.9 H 100/110 V 12.7/13 mA 8,500 29.6 H 54.3 H
Note: See notes under next table.
Coil inductance
(reference value)
Must operate voltage
Must release voltage
Max.
voltage
Power consum. (approx)
(60 Hz)
Four-pole Relays
Relays
Electromechanical
Rated voltage Rated current Coil
50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage
AC 6 V 386 mA 330 mA 5 0.02 H 0.04 H 80% max. 30% min. 110% 1.95 to
12 V 199 mA 170 mA 20 0.10 H 0.17 H 24 V 93.6 mA 80 mA 78 0.38 H 0.67 H 50 V 46.8 mA 40 mA 350 1.74 H 2.88 H 100/110 V 22.5/25.5 mA 19/21.8 mA 1,600 10.5 H 17.3 H 200/220 V 11.5/13.1 mA 9.8/11.2 mA 6,700 33.1 H 57.9 H
DC 6 V 240 mA 25 0.09 H 0.21 H 10% min. 1.5 W
12 V 120 mA 100 0.39 H 0.84 H 24 V 69 mA 350 1.41 H 2.91 H 48 V 30 mA 1,600 6.39 H 13.6 H 100/110 V 15/15.9 mA 6,900 32 H 63.7 H
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperatures of 23°C.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re-
sistor if required.
resistance
Coil inductance
(reference value)
Must operate voltage
Must release voltage
Max.
voltage
Power consum. (approx)
2.5 VA (60 Hz)
General-purpose Relay LY A-33
Contact Ratings
Relay Single contact Bifurcated contacts
1-pole 2-, 3- or 4-pole 2-pole
Load Resistive load
Rated load 110 VAC 15 A
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)*
*Note: P level: λ60 = 0.1 x 10-6/operation, reference value
(cosφ = 1)
24 VDC 15 A 15 A 10 A 7 A
250 VAC 125 VDC
15 A 10 A 7 A
1,700 VA 360 W
100 mA, 5 VDC 100 mA, 5 VDC 10 mA, 5 VDC
Inductive load
(cosφ=0.4, L/R=7 ms)
110 VAC 10 A 24 VDC 7 A
1,100 VA 170 W
Resistive load
(cosφ = 1)
110 VAC 10 A 24 VDC 10 A
250 VAC 125 VDC
1,100 VA 240 W
Inductive load
(cosφ=0.4, L/R=7 ms)
110 VAC 7.5 A 24 VDC 5 A
825 VA 120 W
Resistive load
(cosφ = 1)
110 VAC 5A 24 VDC 5 A
250 VAC 125 VDC
550 VA 120 W
110 VAC 4 A 24 VDC 4A
440 VA 100 W
Characteristics
Item All except Relays with bifurcated contacts Relays with bifurcated contacts Contact resistance 50 m max. Operate time 25 ms max. Release time 25 ms max. Max. operating frequency Mechanical: 18,000 operations/hr
Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance
Endurance Mechanical: AC: 50,000,000 operations min. (at 18,000 operations/hr)
Ambient temperature* Operating:
Ambient humidity Operating: 5% to 85% Weight Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g
Note: 1. The values given above are initial values.
2. The upper limit of 40°C for some Relays is because of the relationship between diode junction temperature and the element used.
Electrical: 1,800 operations/hr (under rated load)
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) Destruction: 1,000 m/s
Malfunction: 200 m/s
DC: 1,00,000,000 operations min. (at 18,000 operations/hr)
Electrical: Single-, three-, and four-pole: 200,000 operations min. (at 1,800 operations/hr
under rated load) Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)
Single- and double-pole standard, bifurcated-contact Relays: –25°C to 55°C (with no icing) (–25°C to 70°C if carry current is 4 A or less) All other Relays: –25°C to 40°C (with no icing) (–25°C to 55°C if carry current is 4 A or less)
2
2
Inductive load
(cosφ=0.4, L/R=7 ms)
A-34 General-purpose Relay LY
Endurance Under Real Loads (reference only)
LY 1
Rated voltage Load type Conditions Operating frequency Electrical life
100 VAC AC motor 400 W, 100 VAC single-phase with 35-A in-
AC lamp 300 W, 100 VAC with 51-A inrush current,
Capacitor (2,000 µF)
AC solenoid 50 VA with 2.5-A inrush current, 0.25-A
rush current, 7-A current flow
3-A current flow 500 W, 100 VAC with 78-A inrush current,
5-A current flow 24 VDC with 50-A inrush current, 1-A cur-
rent flow
current flow 100 VA with 5-A inrush current, 0.5-A cur-
rent flow
LY 2
Rated voltage Load type Conditions Operating frequency Electrical life
100 VAC AC motor 200 W, 100 VAC single-phase with 25-A in-
AC lamp 300 W, 100 VAC with 51-A inrush current,
Capacitor (2,000 µF)
AC solenoid 50 VA with 2.5-A inrush current, 0.25-A
rush current, 5-A current flow
3-A current flow 24 VDC with 50-A inrush current, 1-A cur-
rent flow 24 VDC with 20-A inrush current, 1-A cur-
rent flow
current flow 100 VA with 5-A inrush current, 0.5-A cur-
rent flow
ON for 10 s, OFF for 50 s 50,000 operations
ON for 5 s, OFF for 55 s 100,000 operations
25,000 operations
ON for 1 s, OFF for 6 s 100,000 operations
ON for 1 s, OFF for 2 s 1,500,000 operations
800,000 operations
ON for 10 s, OFF for 50 s 200,000 operations
ON for 5 s, OFF for 55 s 80,000 operations
ON for 1 s, OFF for 15 s 10,000 operations
150,000 operations
ON for 1 s, OFF for 2 s 1,000,000 operations
500,000 operations
Relays
Electromechanical
LY 4
Rated voltage Load type Conditions Operating frequency Electrical life
100 VAC AC motor 200 W, 200 VAC triple-phase with 5-A in-
AC lamp 300 W, 100 VAC with 51-A inrush current,
Capacitor (2,000 µF)
AC solenoid 50 VA with 2.5-A inrush current, 0.25-A
rush current, 1-A current flow 750 W, 200 VAC triple-phase with 18-A in-
rush current, 3.5 A current flow
3-A current flow 24 VDC with 50-A inrush current, 1-A cur-
rent flow 24 VDC with 20-A inrush current, 1-A cur-
rent flow
current flow 100 VA with 5-A inrush current, 0.5-A cur-
rent flow
ON for 10 s, OFF for 50 s 500,000 operations
70,000 operations
ON for 5 s, OFF for 55 s 50,000 operations
ON for 1 s, OFF for 15 s 5,000 operations
ON for 1 s, OFF for 2 s 200,000 operations
ON for 1 s, OFF for 2 s 1,000,000 operations
500,000 operations