Omron E5CN-HQ2M-500, E5CN-HQ2MD-500, E5CN-HC2M-500, E5CN-HV2M-500, E5CN-HR2MD-500 User Manual

...
CSM_E5CN-H_DS_E_4_7
1
Advanced Digital Temperature Controller
E5CN-H (48 x 48 mm)
A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function.
• High-resolution display with 5 digits/0.01°C display in a compact
Controller (48 x 48 mm).
• High-speed sampling cycle of 60 ms.
• High Accuracy Thermocouple/Pt input: ±0.1% of PV Analog input: ±0.1% FS
• Universal inputs on all models (thermocouple, PT, or analog input) to handle various sensors with one Controller.
A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/ manual, RUN/STOP, and alarms) and the PV or SV.
• Flexible contact outputs with logic operations (AND, OR, and delays) set from the Support Software (CX-Thermo Ver. 4.0)
• Preventive maintenance for relays in the Temperature Controller using a Control Output ON/OFF Counter.
Main I/O Functions
48 × 48 mm
E5CN-H
Refer to Safety Precautions for E5@N/E5@N-H.
Refer to Operation for E5@N/ E5@N-H for operating procedures.
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
Universal Sensor Inputs
Universal thermocouple/Pt/analog (current/voltage) inputs.
Indication Accuracy
Thermocouple/Pt input: ±0.1% of PV
Analog input: ±0.1% FS
2-level Display: PV and SV
5-digit Display with high resolution of 0.01°C
E5CN-H
Event Inputs
None
Two
Sampling Period
60 ms
Control Output 1
Relay output
Voltage output (for driving SSR)
Current output
Linear voltage output
Control Output 2
None
Voltage output
(for driving SSR)
Auxiliary Outputs
Two
Auto/manual switching
Temperature Controller status display
Simple program function
Logic operations
Control output ON/OFF count alarm
PV change rate alarm
Models also available with RS-485 or
RS-232C communications
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product.
E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157)
E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159)
Buy Now: www.ValinOnline.com | Phone: 800-774-5630 | Email: CustomerService@valin.com
E5CN-H
2
Lineup
Note: Models with one control output and models with two control outputs can be used for heating/cooling control.
Model Number Structure
Model Number Legend
Controllers
1. Type
H: Advanced
2. Control Output 1
R: Relay output Q: Voltage output (for driving SSR) C: Current output V: Linear voltage output
3. Auxiliary Outputs
2: Two outputs
4. Option 1
M: Option Unit can be mounted.
5. Power Supply Voltage
Blank: 100 to 240 VAC D: 24 VAC/VDC
6. Case Color
Blank: Black W: Silver
7. Terminal Cover
-500: With terminal cover
Option Units
1. Applicable Controller
CN: E5CN-H or E5CN
2. Function 1
Blank: None Q: Control output 2 (voltage output for driving SSR) P: Power supply for sensor C: Current output
3. Function 2
Blank: None H: Heater burnout/SSR failure/Heater overcurrent detection (CT1) HH: Heater burnout/SSR failure/Heater overcurrent detection
(CT2) B: Two event inputs 03: RS-485 communications H03: Heater burnout/SSR failure/Heater overcurrent detection
(CT1) + RS-485 communications
HB: Heater burnout/SSR failure/Heater overcurrent detection
(CT1) + Two event inputs
HH03: Heater burnout/SSR failure/Heater overcurrent detection
(CT2) + RS-485 communications
H01: Heater burnout/SSR failure/Heater overcurrent detection
(CT1)/RS-232C communications F: Transfer output BF: Two event inputs/Transfer output
4. Version
N2: Available only to models released after January 2008
Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@).
Terminal block
E5CN-H
Advanced Type
Fully universal input
2 control outputs
1 control output
2 auxiliary outputs
2 auxiliary outputs
1 2345 6 7
E5CN-@@@M@-@-500
1 234
E53-@@@@
Buy Now: www.ValinOnline.com | Phone: 800-774-5630 | Email: CustomerService@valin.com
3
E5CN-H
Ordering Information
Controllers
Option Units
One of the following Option Units can be mounted to provide the E5CN with additional functions.
Note: These Option Units are applicable only to models released after January 2008.
Accessories (Order Separately)
USB-Serial Conversion Cable
Terminal Cover
Note: 1. The Terminal Cover comes with the E5CN-@@@-500
models.
2. The E53-COV10 cannot be used.
Waterproof Packing
Note: Waterproof Packing is included with the controller only for
models with terminal blocks.
Current Transformers (CTs)
Adapter
Note: Use this Adapter when the panel has been previously prepared
for the E5B@.
DIN Track Mounting Adapter
Front cover
CX-Thermo Support Software
Size Case Color Power supply voltage Auxiliary output Control output 1 Model
1/16 DIN 48 × 48 × 78 (W × H × D)
Black
100 to 240 VAC 2
Relay output E5CN-HR2M-500
Voltage output (for driving SSR) E5CN-HQ2M-500
Current output E5CN-HC2M-500
Linear voltage output E5CN-HV2M-500
24 VAC/VDC 2
Relay output E5CN-HR2MD-500
Voltage output (for driving SSR) E5CN-HQ2MD-500
Current output E5CN-HC2MD-500
Linear voltage output E5CN-HV2MD-500
Silver
100 to 240 VAC 2
Relay output E5CN-HR2M-W-500
Voltage output (for driving SSR) E5CN-HQ2M-W-500
Current output E5CN-HC2M-W-500
24 VAC/VDC 2
Relay output E5CN-HR2MD-W-500
Voltage output (for driving SSR) E5CN-HQ2MD-W-500
Current output E5CN-HC2MD-W-500
Functions Model
Communications RS-485
3-phase heater burnout/SSR failure/ Heater overcurrent detection
E53-CNHH03N2
Heater burnout/SSR failure/ Heater overcurrent detection
Event inputs E53-CNHBN2
Communications RS-485
Control output 2 (Voltage for driving SSR)
E53-CNQ03N2
Communications RS-485
Heater burnout/SSR failure/ Heater overcurrent detection
E53-CNH03N2
Communications RS-485
E53-CN03N2
Event inputs E53-CNBN2
Heater burnout/SSR failure/ Heater overcurrent detection
Control output 2 (Voltage for driving SSR)
E53-CNQHN2
3-phase heater burnout/SSR failure/ Heater overcurrent detection
Control output 2 (Voltage for driving SSR)
E53-CNQHHN2
Event inputs
Control output 2 (Voltage for driving SSR)
E53-CNQBN2
Control output 2 (Voltage for driving SSR)
Transfer Output E53-CNQFN2
Event inputs Transfer Output E53-CNBFN2
Communications RS-232C
Control output 2 (Voltage for driving SSR)
E53-CNQ01N2
Communications RS-232C
E53-CN01N2
Communications RS-232C
Heater burnout/SSR failure/ Heater overcurrent detection
E53-CNH01N2
Model
E58-CIFQ1
Model
E53-COV17
Model
Y92S-P8
Hole diameter Model
5.8 dia. E54-CT1
12.0 dia. E54-CT3
Connectable models Model
Terminal type Y92F-45
Model
Y92F-52
Type Model
Hard Front Cover Y92A-48B
Soft Front Cover Y92A-48D
Model
EST2-2C-MV4
Buy Now: www.ValinOnline.com | Phone: 800-774-5630 | Email: CustomerService@valin.com
E5CN-H
4
Specifications
Ratings
* For models with current outputs, control output 1 can be used as a transfer output.
Power supply voltage
No D in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power consumption
100 to 240 VAC: 8.5 VA (max.) (E5CN-HR2 at 100 VAC: 3.0 VA) 24 VAC/VDC: 5.5 VA (24 VAC)/3.5 W (24 VDC) (max.) (E5CN-HR2D at 24 VAC: 2.7 VA)
Sensor input
Any of the following can be selected (i.e., fully universal input). Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Control output
Relay output SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Voltage output (for driving SSR)
Output voltage: 12 VDC ±15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Current output 4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000 *
Linear voltage output
0 to 10 VDC (load: 1 kΩ min.), Resolution: Approx. 10,000
Auxiliary output
Number of outputs 2 max.
Output specifications
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Event input
Number of outputs 2
External contact input specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Logic opera­tions
Number of operations
8 max. (Combinations can be made using work bits.)
Operations
Logic operation: Any of the following four patterns can be selected. The input status may be inverted.
(A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C, and D are four inputs.)
Delay: ON delay or OFF delay for the results of the logic operation given above.
Setting time: 0 to 9999 s or 0 to 9999 min
Output inversion: Possible
Outputs One work bit per operation
Work bit assignments
Any of the following can be assigned to up to eight work bits (logic operation results): Event input operations, auxiliary outputs, or control outputs.
Transfer outputs
Number of outputs 1 max.
Output specifications
Current output: 4 to 20 mA DC, Load: 600 Ω max., Resolution at 4 to 20 mA: Approx. 10,000
RSP input Not supported
Setting method Digital setting using front panel keys
Indication method
11-segment digital display and individual indicators (7-segments displays also possible) Character height: PV: 11 mm, SV: 6.5 mm
Bank switching
Supported (number of banks: 8) Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.)
Other functions
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, PV/SV status display, logic operations, automatic cooling coefficient adjustment
Ambient operating temperature
10 to 55°C (with no condensation or icing), for 3-year warranty: 10 to 50°C
Ambient operating humidity 25% to 85% Storage temperature 25 to 65°C (with no condensation or icing)
Buy Now: www.ValinOnline.com | Phone: 800-774-5630 | Email: CustomerService@valin.com