NuTone LS100LF, LS80LF User Manual

IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit6 only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for
the application and be connected to a GFCI (Ground Fault Circuit Interrupter)
protected branch circuit. F. NEVER place a switch where it can be reached from a tub or shower.
Do not install in a ceiling insulated to a value greater than R40.
Suitable for use with solid state speed controls. Use NuTone Model VS-64.
Not for use in kitchens.
FOR BEST RESULTS
When installing the Ventilator in a new construction site, install housing during
the rough-in construction of the building. The blower unit and grille should be installed after the finished ceiling is in place.
To install this ventilator in an existing building requires an accessible area (attic or
crawl space) above the planned location.
INSTALLATION IN A NEW CONSTRUCTION SITE
PREPARATION
1. Remove blower/power unit assembly from housing
2. Remove wiring knockouts from housing, as needed.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Ultra-QuieTTest Fans/Lights
MODELS: LS80LF, LS100LF
SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.
FIGURE 1
ROOF CAP
4" DIAMETER DUCT
90° ELBOW
WALL CAP
CEILING INSTALLATION
FIGURE 2
GROUND
SCREW
120v AC SUPPLY
WHITE (NEUTRAL)
SWITCH BOX
FAN
RECEPTACLE
LAMP
RECEPTACLE
(3 PIN)
BLACK (HOT)
MOUNTING THE HOUSING
1. Refer to Figure 3. Insert mounting brackets at each end of housing.
2. Place long side of housing parallel to ceiling joist. Position housing in
desired location. Make sure housing flange is even with the planned finished ceiling.
3. Use screws or nails (not provided) to secure mounting brackets to
ceiling joists.
4. Refer to Figure 1. Use 4" round duct to discharge the ventilator to the
outside.
IMPORTANT: Be sure nothing obstructs the discharge of the ventilator. Make sure that insulation does not get into the duct work or into the fan.
WIRING
Refer Figure 2.
1. Run 120v AC house power wiring (with ground) through switch box to junction box in ventilator housing.
2. Remove ventilator junction box cover.
3. Connect white supply common lead to white leads from fan and light receptacle. Connect black supply wire from fan switch to black wire from fan receptacle. Connect black supply wire from light switch to black wire from light receptacle. Connect supply ground wire to green ground screw.
4. Replace junction box cover.
NOTE: BE SURE VENTILATOR AND SWITCH ARE PROPERLY
GROUNDED. ALL WIRING MUST COMPLY WITH LOCAL ELECTRICAL CODES.
BALLAST INSTALLATION
1. Refer to Figure 4. Slide ballast tab into slot in housing side and secure ballast with mounting screw.
2. Insert the plug from the ballast with white and black leads, into the three pin receptacle on the wiring compartment cover.
POWER/BLOWER UNIT INSTALLATION
1. Plug motor into socket in housing's junction box.
2. Remove the mounting screw from the housing.
3. Position the power unit in the housing using the guide on the blower housing to engage the opening in the housing.
4. Slide the blower forward and install the mounting screw securely.
5. Refer to Figure 3. Securely tighten screw.
INSTALLATION IN EXISTING CONSTRUCTION
Installing the ventilator in an existing house requires an accessible
area (attic crawl space) above the planned installation location.
Review “INSTALLATION IN A NEW CONSTRUCTION” and follow all
instructions which apply to your installation.
Location – locate ventilator parallel to a ceiling joist. Wiring and Ducting – plan ducting and wiring before proceeding with
installation.
Refer to Figure 2 for wiring and Figure 1 for ducting.
CAUTION: Check area above planned installation to be sure that:
1. Ducting can be installed.
2. Wiring can be run to the planned location.
3. No wiring or other obstructions might interfere with installation.
INSTALLATION FROM ACCESSIBLE AREA ABOVE
1. From below, drill a small hole in ceiling at the planned location. Stick clothes hanger through hole to help locate it.
2. Locate hole in attic or crawl space.
3. In attic or crawl space, mark ceiling for cutout by using the housing as a template. The long side of cutout must be parallel to ceiling joist.
4. Make cutout along marked line.
NOTE: If ceiling is plaster, cutout should be made from below
to avoid chipping plaster.
5. Install housing, connect wiring and ducting, install power unit/blower assembly and install grille.
FIGURE 3
DISCHARGE OPENING
HOUSING
MOUNTING BRACKET
MOUNTING SCREWS
MOUNTING SPRING
NOTCHED BOSS
POWER UNIT
GRILLE
FIGURE 4
BALLAST ASSEMBLY
BLUE AND RED
WIRES
BLACK AND
WHITE WIRES
FIGURE 5
Product specifications subject to change without notice.
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A., Rev. 05/2001, Part No. 88964
One Year Limited Warranty
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Date of Installation Builder or Installer
Model No. and Product Description
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599. Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
Rev. 03/2001
GRILLE/LIGHT INSTALLATION
1. Refer to Figure 5. Open reflector on back of grille by depressing
latch and lifting up on reflector. Install one 26 watt compact fluorescent lamp NEMA type CFQ26W/G24D. Note: The reflector holds the glass diffuser in place. Be careful that diffuser does not drop out of grille. Close reflector and snap into position.
2. Depress mounting springs in sides if grille and insert in either side of housing. Connect the plug from the reflector to the connector (red and blue leads) from the ballast.
3. Press grille firmly against ceiling.
LAMP REPLACEMENT
1. Pull grille down from ceiling as far as the grille springs will allow. Disconnect plug of reflector from the ballast connector. Depress the grille mounting springs and remove the grille from the ceiling.
2. Refer to Figure 5. Place the grille on a table or counter top. Open reflector by depressing latch and lifting up on reflector. Note: Reflector holds glass diffuser in place. Be careful that diffuser does not drop out of grille. Relamp lamp with one 26 watt NEMA type CFQ26W/H24D fluorescent lamp. Close reflector and snap into position.
3. To remount grille, depress grille springs on either side of grille and insert into slots in housing. Connect plug from reflector to the connector from the ballast. Press grille firmly into place against ceiling.
Loading...
+ 7 hidden pages