NIHON KOHDEN V ECG-9320K User manual

| cardiofax V

ELECTROCARDIOGRAPH

ECG-9320K

0614-0024511

CONTENTS

General Handling Precautions ...............................

 

 

i

EMC Related

Caution

......................................

 

 

iil

Caution .................................................

 

 

 

 

iv

Conventions

Used in

this Manual

and

Instrument .............

V

@ Warnings,

Cautionsand

Notes .....................

v

© Explanation of the Symbols

in this Manual/Instrument

v

Section

1

Introduction

 

 

 

 

 

cece.

1.01

 

1-1

General .................................................

 

 

 

 

 

 

 

 

 

1.1

 

1-2

Important

Safety Information

..............................

 

 

1.2

 

1-3

Panel

Descriptions

........................................

 

 

 

 

 

 

1.3

 

 

1-31

Top

View

.........................................

 

 

 

 

 

 

1.3

 

 

1-3-2

Operation

Panel

...................................

 

 

 

 

1.4

 

 

1-3-3

Front

Panel .......................................

 

 

 

 

 

 

1.6

 

 

1-3-4

Rear

Panel

........................................

 

 

 

 

 

 

1.8

 

 

1-3-5

Input

Box

Set

....................................

 

 

 

 

 

1.10

 

 

Basic

Screen

and Menu

Window ...........................

 

 

1.11

 

 

1-4-1

Basic

Screen

.....................................

 

 

 

 

 

1.11

 

 

1-4-2

Menu

Window

 

...................................

 

 

 

 

1.15

 

 

Functions of Each Screen and Window

.....................

 

1.16

 

 

Basic

Operation Concept

 

.................................

 

 

 

1.17

Section

2

Installation

and

Start

Up ...............

 

9.01

 

2-1

Selecting a

Suitable Location

..............................

 

 

2.1

 

2-2

Connecting

the Input

Box

.................................

 

 

 

2.2

 

2-3

Charging the

Built-in

Battery

.............................

 

 

2.5

 

2-4

Setting the

Recording

Paper

...............................

 

 

2.6

 

 

2-4-1

Z-fold Recording Paper

.............................

 

 

2.6

 

 

2-42

Roll Recording Paper

.............................

 

 

2.10

 

2-5

Preparing

the IC Memory

Card, Flash

Disk Card

and

 

 

 

Floppy

Disk

.............................................

 

 

 

 

 

 

 

2.11

 

 

2-5-1

Precautions when Using IC Memory Card/

 

 

 

 

Flash

Disk

Card

..................................

 

 

 

 

2.11

 

 

2-5-2

How

to Insert

Battery

into IC

Memory Card .........

2.12

 

 

2-5-3

Inserting and Removing the IC Memory

Card/

 

 

 

 

Flash

Disk

Card

..................................

 

 

 

 

2.15

 

 

2-5-4

Inserting and Removing the Floppy Disk

...........

2.18

 

 

Grounding

and Connecting

the Power

Cord ................

 

2.19

 

2-7

Turning the

Power

On

 

...................................

 

 

 

 

2.20

 

 

2-7-1

Operating

on

AC

Power ...........................

 

 

2.20

 

 

2-7-2

Operating

on

Battery

Power

.......................

 

2.21

 

 

Operator's Manual

ECG-9320

 

 

C.1

2-8

Calling Up the Menu Window

............................

2.22

2-9

Preparation for the Automatic ECG Filing and Transferring

2.23

2-10

Receiving,

Saving and

Printing

Files ......................

2.24

 

2-10-1

General ..

 

ον ον εν εν εν ων

2.24

 

2-10-2

Preparation to

Receive

and Record Files ............

2.24

 

2-10-3

Handling Received Files ..........................

2.25

 

2-10-4

Running Out of Paper and Other Printing Interruptions

 

 

 

when

Printing

without

Saving ....................

2.26

2-11

Changing a

Program

....................................

 

2.28

2-12

Initializing

a

Barcode

Reader .............................

 

2.29

Section 3

Changing

Settings

Before Measure-

 

 

ment

(System

Setup

Window)

.....

3.C1

3-1

Explanation

and List of All Setting Items ....................

 

3.1

 

3-1-1

 

General

...........................................

 

 

 

 

 

 

 

3.1

 

3-1-2

 

Complete

List

of

Settings and

Defaults ...............

 

3.2

3-2

How

to Change

Settings

.................................

 

 

 

 

3.11

3-3

Printing

a List

of All Settings

............................

 

 

 

3.13

3-4

Registering

or Editing

Examinations

(Menu Setup Window)

3.14

3-5

Examination Types (Standard 12-lead and Cabrera Lead,

 

 

Nehb

Lead and

External

Input)

and

Settings ...............

 

3.17

 

3-5-1

 

Setting Items for Each Examination Type ..........

 

3.17

 

3-5-2

 

Manual Recording (All Examination Types)

........

3.19

 

3-5-3

 

Auto Recording (Standard 12-lead, Cabrera Lead,

 

 

 

 

Nehb

Lead

Only)

.................................

 

 

 

 

3.21

 

3-5-4

 

Rhythm Recording (Standard 12-lead, Cabrera

Lead,

 

 

 

 

Nehb

Lead

Only)

.................................

 

 

 

 

3.25

 

3-5-5

 

Post-processing (Standard 12-lead, Cabrera Lead,

 

 

 

 

Nehb

Lead

Only)

.................................

 

 

 

 

3.26

 

3-5-6

 

Report Recording (Standard 12-lead, Cabrera

Lead,

 

 

 

 

Nehb

Lead

Only)

.................................

 

 

 

 

3.27

 

3-5-7

 

Rhythm Lead (Standard 12-lead, Cabrera Lead,

 

 

 

 

Nehb

Lead

Only)

.................................

 

 

 

 

3.31

 

3-5-8

 

EXTRA 6

Ch Lead (Standard 12-lead and

 

 

 

 

 

Cabrera

Lead

Only) ..............................

 

 

 

 

3.33

 

3-5-9

 

Lead Selection (External Signal Only) .............

 

3.33

 

3-5-10

Slow

Recording/Hi Cut

Filter

 

 

 

 

 

 

(All

Examination

Types) ..........................

 

 

 

3.34

 

3-5-11

Power Up (All Examination Types) ................

 

3.35

 

3-5-12

Requesting Phys.

Registration

 

 

 

 

 

 

(All

Examination

Types) ..........................

 

 

 

3.38

3-6

Settings

for

Patient Data

Entry

...........................

 

 

 

3.39

 

Settings

for

ID

Card

.....................................

 

 

 

 

 

3.41

3-8

Settings

for

Barcode ....................................

 

 

 

 

 

 

3.43

3-9

Settings

for

Communication ..............................

 

 

 

 

3.45

3-10

Settings

for

Data Compression ..................

and

Drive

 

3.46

3-11

Settings

for Program and ..................Hospital Name

 

3.47

3-12

Settings

for

Sound

.......................................

 

 

 

 

 

 

3.48

C.2

 

Operator’s

Manual

ECG - 9320

 

 

 

 

3-13

Settings for Recorder and AC Filter .......................

3-14

Settings for Language and LCD ...........................

3-15

Settings

for Summary Data

Creation ......................

3-16

Settings for Date and Time

...............................

3-17

Settings for Height, Weight and Blood Pressure ............

3-18

Saving/Loading

the

System

Settings .......................

 

3-18-1

Saving the

System

Settings in the Memory Card

 

 

or Floppy

Disk ...................................

 

Section

4

Entering

 

the

Patient

Information

.

4.C1

 

4-1

General

.................................................

 

 

 

 

 

 

 

41

 

4-2

Using

the Keyboard and Numeric Keypad ..................

 

4.3

 

 

4-2-1

Procedure

........................................

 

 

 

 

4.3

 

 

4-2-2

Keyboard

and

Numeric Keypad .....................

 

4.4

 

 

4-2-3

Procedures

to Enter the Patient Information

 

 

 

 

 

for

Each

Item

.....................................

 

 

 

4.5

 

4-3

Using

the

Magnetic Card

Reader

..........................

 

4.8

 

4-4

Using

the

Barcode

Reader .................................

 

 

4.8

 

4-5

Using

the

Data

Filing

System ..............................

 

 

4.9

 

 

Patient Index Database (ID Data File) .....................

 

4.10

Section

5

Preparing

the

Patient ....................

 

5.C1

 

5-1

Attaching

the

Electrodes

for Standard 12 Lead ECG and

 

 

 

 

Cabrera Lead

ECG

Recording ..............................

 

 

5.1

 

5-2

Attaching

the

Electrode

for Nehb Lead ECG Recording .......

 

5.3

 

5-3

Patient Cable

Tip

Color

Coding ............................

 

 

5.4

 

5-4

Lead

Connection

.........................................

 

 

 

 

5.5

 

5-5

Error

Indication when the Electrode is Not Attached Firmly

..

5.6

Section

6

Measuring

Resting

ECG

 

 

 

 

Waveforms..................................

 

 

 

 

 

 

 

6.С1

 

6-1

General

.................................................

 

 

 

 

 

 

 

6.1

 

 

6-1-1

Available Recordings and Operation Tools ...........

 

6.1

 

 

6-1-2

Notes

for Accurate Measurement ...................

 

6.3

 

6-2

Standard 12 Lead ECG Recording and Cabrera Lead ECG

 

 

 

 

Recording

................................................

 

 

 

 

 

 

 

6.4

 

 

6-2-1

General

 

.......................

 

 

 

 

6.4

 

 

6-2-2

Factory

Default

Settings ...........................

 

 

6.5

 

 

6-2-3

Automatic

Recording ..............................

 

 

6.8

 

 

6-2-4

Manual

Recording ................................

 

 

6.10

 

 

6-2-5

Rhythm

Recording ...............................

 

 

6.13

 

6-3

Nehb

Lead

ECG

Recording ...............................

 

 

6.14

 

 

6-3-1

General

....................

 

 

 

ea

 

6.14

 

 

6-3-2

Factory

Default ..........................

Settings

 

 

6.14

 

 

6-3-3

Automatic .............................

Recording

 

 

6.17

Operator's Manual ECG-9320

С.3

 

 

6-3-4

Manual

Recording

...............................

 

 

 

6.19

 

 

6-3-5

Rhythm

Recording

...............................

 

 

 

6.20

 

6-4

Recording

a

Summary

Report

............................

 

 

6.21

 

 

6-4-1

General

.........................................

 

 

 

 

 

 

6.21

 

 

6-4-2

Recording

Procedure .............................

 

 

 

6.22

 

6-5

Recording

Examples .....................................

 

 

 

 

 

6.23

Section

7

Recording

the

External

Signal

......

7.C1

 

7-1

General

 

..................................................

 

 

 

 

 

 

 

 

7.1

 

7-2

Recording ......................................

Procedure

 

 

 

 

 

7.3

 

 

7-2-1

Freeze ..................................

Recording

 

 

 

 

7.3

 

 

7-2-2.

Manual .................................

Recording

 

 

 

 

7.4

Section

8

Managing ...................

Saved

Files

 

 

8.C1

 

8-1

General

..................................................

 

 

 

 

 

 

 

 

 

8.1

 

8-2

Calling

Up ....................

the

Data Management Sereen

 

 

8.4

 

8-3

Searching ........................................

for Files

 

 

 

 

 

 

8.5

 

8-4

Selecting Files ............................................

 

 

 

 

 

 

 

8.7

 

8-5

Serial Comparison

Recording

 

 

 

 

 

 

(Recording .......................

the

Files Chronologically)

 

 

8.7

 

8-6

Recording ...........................................

Files

 

 

 

 

 

 

 

8.8

 

 

8-6-1

Recording ....................................

Files

 

 

 

 

 

8.8

 

 

8-6-2

Recording

Files

with Changing the

Recording

Format

. 8.8

 

8-7

Transferring ......................................

Files

 

 

 

 

 

 

8.11

 

 

Editing

Files ..........................................

 

 

 

 

 

 

:

8.12

 

 

8-8-1

Retrieving ..........Files and Selecting Operations

 

8.12

 

 

8-8-2

Editing ......................

Patient

Information

 

 

8.14

 

 

8-8-3

Analyzing .............

Retrieved ECG Waveforms

 

8.15

 

 

8-8-4

Recording .....................

the Retrieved

Files

 

 

8.15

 

 

8-8-5

Closing .....................the File Edit Window

 

 

8.16

 

8-9

Deleting

Files ..........................................

 

 

 

 

 

 

 

8.17

 

8-10

CopyingFiles .................... ..

 

 

 

 

 

 

ooo o

8.19

 

8-11

Formatting ...........

an

IC Memory

Card

and Floppy

Disk

 

8.21

 

 

8-11-1

Formatting ..................the IC Memory Card

 

 

8.21

 

 

8-11-2

Formatting .......................

the

Floppy

Disk

 

 

8.23

Section

9

Troubleshooting

and

 

 

 

 

 

/7O/

7essa96S

 

 

 

 

9.C1

 

9-1

Recording ..........................

Clear ECGWaveforms

 

 

9.1

 

 

9-1-1

AC ....................................

Interference

 

 

 

 

9.1

 

 

9-1-2

Muscle ..................

Tremor

Interference (EMG)

 

 

9.2

 

 

9-1-3

Wandering ................................

Baseline

 

 

 

9.2

 

 

9-1-4

Abnormal .................................

Printout

 

 

 

 

9.3

 

9-2

Troubleshooting ..........................................

 

 

 

 

 

 

9.4

 

9-3

Error Message ............................................

 

 

 

 

 

 

 

9.6

C.4

Operator’s Manual ECG-9320

Section 10

Maintenance

οι...

10.C1

10-1

Cleaning and Disinfection ................................

 

10.1

 

10-1-1

Cleaning

Schedule ................................

 

10.1

 

1O-1-2 Cleaning

 

 

 

10.1

 

10-1-3

Disinfecting

the Electrodes ........................

 

10.2

 

10-1-4

Cleaning

the

Thermal Head .......................

 

10.2

 

10-1-5

Cleaning

the

Floppy Disk Drive Unit ...............

 

10.3

10-2

Testing

the

System

......................................

 

10.4

10-3

Periodically

Replacement Schedule ........................

 

10.4

Section 11

Reference

......................................

 

 

11.C1

11-1

Specificatlons

................

 

ee

o

11.1

11-2

Standard Accessories ....................................

 

 

11.4

11-3

Optlons ..............

 

νεο

νε ενω ο ενω ο ων ο εν ο εν ο ενω ο εν ο ο ως

11.5

 

11-3-1

Hardware

Options ................................

 

 

11.5

 

11-3-2 Software

Options .................................

 

 

11.6

11-4

Slave

Monitor

Interface Board

............................

 

11.7

11-5

Attaching the

Ferrite Core ...............................

 

 

11.8

Operator’s Manual ECG-9320

C.5

GENERAL HANDLING PRECAUTIONS

This device is intended for use only by qualified medical personnel.

Use only Nihon Kohden approved products with this device. Use of non approved products or in a non approved manner may affect the performance

specifications

of

the

device.

This includes, but is not

limited to, batteries,

recording

paper,

pens

and

extension cables and cords

for electrodes, input

boxes and

AC

power.

 

 

 

Please read these precautions thoroughly before attempting to operate the instrument.

1.To safely and effectively use the instrument, its operation must be fully understood.

2.When installing or storing the instru-

ment, take the following precautions:

(1)Avoid moisture or contact with water,

extreme atmospheric pressure, excessive humidity and temperatures, poorly ventilated areas, and dusty saline or sulphuric air.

(2)Place the instrument on an even, level floor. Avoid vibration and mechanical shock even during moving.

(3)Avoid placing in an area where chemicals are stored or where there is danger of gas leakage.

(4) The power line source to be applied to the instrument must correspond in frequency and voltage to specifications, and have sufficient current capacity.

(5)Choose a room where a proper grounding facility is available.

3.Before Operation

(5) All circuitry used for direct patient connection must be doubly checked.

(6)Check that battery voltage and battery condition are perfect when using

battery-operated models.

. During Operation

(1)Both the instrument and the patient must receive constant, careful attention.

(2)Turn power off or remove electrodes and/or transducers when necessary to assure the patient’s safety.

(3)Avoid direct contact between the

instrument and the patient.

- To Shutdown After Use

(1) Turn power off with all controls returned to their original positions.

(2)Remove the cords gently; do not use force to remove them.

(3)Clean the instrument together with all accessories to keep them ready for their next use.

(1)Check that the instrument is in perfect operating order.

(2)Check that the instrument is grounded properly.

(3)Check that all cords are connected properly.

(4)Pay extra attention when the

instrument is in combination with other instruments to avoid misdiagnosis or other problems.

. The instrument must receive expert, professional attention for maintenance and repairs. When the instrument is not functioning properly, it should be clearly marked to avoid operation while itis out of order.

. The instrument must not be altered or modified in any way.

Operator's Manual ECG-9320

|

8.Maintenance and Inspection:

(1)The instrument and parts must undergo regular maintenance inspection at least every 6 months.

(2)If stored for extended periods without being used, make sure prior to operation that the instrument is in perfect operating condition.

(3)Technical information such as circuit diagrams, parts list, descriptions, calibration instructions or other information is available for qualified

user technical personnel upon request from your Nihon Kohden distributor.

9.When the instrument is used with an

electrosurgical instrument, pay careful attention to the application

and/or location of electrodes and/or transducers to avoid possible burn to the patient.

10.When the instrument is used with a defibrillator, make sure that the

instrument is protected against defibrillator discharge. If not, remove patient cables and/or transducers from the instrument to avoid possible damage.

 

 

 

 

 

 

 

 

WARRANTY

POLICY

 

 

 

 

 

 

 

 

Nihon Kohden Corporation (NKC) shall warrant its

products against all defects in

materials and workmanship for one year from the date

of

 

delivery.

However,

consumable

materials

such

as

recording

paper,

ink,

stylus

and

 

battery

are

excluded

from

the

warranty.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NKC

or

its

authorized

agents will repair or replace

any products which prove to be

defective

during

the

warranty

period,

provided

these

products

are used

as

prescribed

by

the operating

instructions

given in

the

operator’s and

service

manuals.

 

 

 

No other party is authorized to

make

any

warranty

 

or

assume

liability

for

NKC’s

products.

NKC

will

not recognize

any

other

warranty,

 

either implied or in writing.

In

addition, service performed by someone other than NKC

or

its

authorized

agents

or

technical

modification

or

change

of

products

without

 

prior

consent

of

NKC may

be

cause for voiding this warranty.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective

products

or

parts

must

be

returned

to

NKC

 

or

its

authorized

agents,

along

with

an explanation

of

the

failure.

Shipping

costs

must

 

be

pre-paid.

 

 

 

 

 

This warranty does not apply to products that have

 

been

modified,

 

disassembled,

reinstalled

or

repaired

without

Nihon

Kohden

approval

or which

have

been

subjected

to

neglect

or

accident,

damage

due

to

accident,

fire,

lightning,

 

vandalism,

water

or

other casualty, improper installation or application, or on which the original identification marks have been removed.

In the USA and Canada other warranty policies may apply.

Operator’s Manual ECG-9320

EMC RELATED CAUTION

This equipment and/or system complies with the International Standard IEC 601-1-2 for electromagnetic compatibility for medical electrical equipment and/or system. However, an

electromagnetic environment that exceeds the limits or levels

stipulated

in the IEC 601-1-2, can

cause

harmful

interference

to the equipment

and/or system

or

cause

the

equipment

and/or

system

to

fail

to perform

its

intended

function

or degrade its

intended

performance.

Therefore,

during

the

operation of

the

eguipment

and/or

system, if there

is any undesired deviation from

its intended operational performance, you must avoid, identify

and

resolve the adverse

electromagnetic effect before continuing to use the equipment

and/or

system.

 

The following describes some common interference sources and remedial actions:

1.

The equipment

and/or

system

is not

grounded:

 

 

 

 

 

 

 

For AC powered equipment and/or system, use the provided grounding cable to connect the

 

equipotential

terminal

of

the

equipment to

the

grounding

system of the

facility.

2.

Strong

electromagnetic interference from a nearby emitter source such

as

an

authorized

 

radio station or cellular phone:

 

 

 

 

 

 

 

 

 

Install

the equipment

and/or

system

at another

location if

it

is interfered

 

by

an emitter

 

source

such

as

an authorized

radio

station.

Keep the emitter

source such

as

cellular phone

 

away

from

the

equipment

and/or system.

 

 

 

 

 

 

 

3.Radio-frequency interference from other equipment through the AC power supply of the

equipment

and/or

system:

 

Identify the

cause

of

this interference

and if possible remove this interference source. If this

is not possible, use

a

different power

supply.

4.Effect of direct or indirect electrostatic discharge:

Make sure all users

and patients in contact with the equipment

and/or system are free from

direct or indirect electrostatic energy before using it. A humid

room can help lessen this

problem.

 

 

 

 

If the above

suggested

remedial actions

do not solve the problem,

consult your Nihon Kohden

Corporation

subsidiary

or distributor for

additional suggestions.

 

Operator’s Manual ECG-9320

 

 

 

 

CAUTION

 

 

 

 

 

 

@ Never turn the

power off

or remove

the

memory

card or

floppy

disk while the

message

“Executing.

Do not turn power off.”

is displayed

at

the top of the screen.

This may

cause

loss of data.

The message is

displayed

when data

is

saved to

or read

from

a

memory

card or floppy

disk and

during data transfer with an external instrument.

 

 

 

 

 

G

ecuting

 

 

 

 

 

 

 

 

 

 

 

 

Ja

Ki”

not

turn power off

 

 

 

 

 

 

 

 

 

 

 

 

 

tv

HAA

 

 

 

 

 

 

 

 

 

 

lolpn

HAAN

 

 

 

 

 

 

 

 

©

Format

the

IC

memory card only on

the ECG-9320 electrocardiograph, otherwise

the IC memory

 

card cannot

be used

with ECG-9320.

For formatting the IC memory

card,

refer

to

Section 8-11-1.

e

Setthe

write

protect

switch to

"WP"

(on) when you read the data

from

the

IC

memory

card on

any

 

other equipment which is not specified by Nihon Kohden.

If write

protect is

off

and any

data

is

 

written

to the

IC memory card

by any other equipment, the

IC memory card

may

become unusable

 

with the ECG-9320.

 

 

 

 

 

 

 

 

 

 

 

Operator's Manual ECG-9320

Conventions Used in This Manual and Instrument

@ Warnings, Cautions and Notes

Warnings, cautions and notes are used in this manual to alert or signal the reader to specific information.

WARNING

A warning alerts the user to the possible injury or death associated with the use or misuse of the instrument.

 

CAUTION

A caution alerts the user to the possible

problems with the instrument associated with its use or

misuse such as instrument malfunction,

instrument failure, damage to the instrument or damage to

other property.

 

NOTE

A note provides specific information, in the form of recommendations, prerequirements, alternative methods or supplemental information.

+ Explanation of the Symbols in this Manual/Instrument

The following symbols found in this manual/instrument bear the respective descriptions as given.

eMain Unit

“On?” only for a part of equipment

o

“Off” only for a part of equipment

Contrast

ECG

(ECG input terminal)

>

|]

Battery charging

C

Alternating current

Operator’s Manual ECG-9320

©)

IL

©

L

/OI s

7

eScreen

Input terminal

Calibration

Automatic control

Recording

Brightness

High voltage

Output terminal (option)

Attention, consult operator's manual

AC power Off (Disconnection from the mains)

AC power On

(Connection to the mains)

Eguipotential terminal

Video

(Video signal output terminal) (option)

Protective ground terminal

Y

QRS sync display

 

Battery check

 

Touch-screen key

 

File/transfer

 

 

a

Paper empty

vi

 

Operator's Manual ECG-9320

 

einput Box Set

4Defibrillation-proof Type CF applied part

@Others

 

The CE

mark

is a

registered

 

trademark of

the

European

C €

Union.

The

products

herewith

0086

comply

with

the

requirements

 

of the

Medical

Device

Directive

93/42/EEC.

Operator's Manual ECG-9320

VII

1. INTRODUCTION

SECTION

INTRODUCTION

1-1

General —......

 

 

 

 

eee

eee

eee

eens

1.1

1-2

Important

Safety

Information

......................................

 

 

 

 

 

 

1.2

1-3

Panel

Descriptions ..........................................

 

 

 

 

 

 

,.....

1.3

 

1-3-1

 

Top View .......................

 

 

 

 

ER

En ek ken ne

1.3

 

1-3-2

 

Operation Panel

..........................................

 

 

 

 

 

 

 

1.4

 

1-3-3

 

Front

Panel ..................................

 

 

 

 

 

,.,........

1.6

 

1-3-4

 

RearPanel ...................................

 

 

 

 

 

,.,........

1.8

 

1-3-5

 

InputBoxSet ............................

 

 

 

,..............

1.10

1-4

Basic

Screen and

Menu Window ...................................

 

 

 

 

 

 

1.11

 

1-4-1

 

Basic

Screen ...........................

 

 

 

 

 

κ κοκ

κ κκ

ο ως

1.11

 

1-4-2

 

Menu

Window

 

 

 

 

 

 

 

 

1.15

1-5

Functions

of Each

Screen

and

Window

.............................

 

 

 

 

 

1.16

1-6

Basic

Operation

Concept

.........................................

 

 

 

 

 

 

 

1.17

Operator's Manual ECG-9320

1.C1

1. INTRODUCTION

1-1

General

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This cardiofax is a real time

cardiograph

with a

3, 6,

or

12-channel recorder.

The 10.4

 

inch LCD touch screen displays

the

ECG

waveforms and various measurement settings

 

and allows efficient and easy

operation.

You can preset up to 12 examinations

and

 

 

operation tools in the menu.

The QP-911E ECG Interpretation software upgrades the

 

cardiograph to

an interpretive

cardiograph.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

Use Nihon Kohden parts and

accessories to assure

maximum

performance

from your

 

instrument.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

An

optional

hardware

and

software

related to the cardiograph are

also

described

in

 

this

manual.

The

word

“optional” is

omitted

in most

parts of

this

manual.

 

 

 

Therefore, some

hardware

and software described in this manual

may

not

apply

to

 

your cardiograph.

For

options,

refer

to Section 11-3.

 

 

 

 

 

 

 

The cardiograph features

the

following functions:

 

 

 

 

 

 

 

1.LCD Screen with Touch-screen Keys

The cardiograph provides the touch keys on the screen. You can select the

measurement settings and verify operation

on the

LCD

touch-screen.

 

On

the 10.4

inch LCD screen, 12 lead ECG waveforms are simultaneously displayed. The

 

various recording information, messages, and marks allow clear ECG recording.

 

Presettable

 

Examination

Menu

 

 

 

 

 

 

 

 

 

 

 

 

You can preset up to 12 examinations containing

various measurement

settings

and

recording formats according to your medical protocol.

 

 

 

 

 

 

 

 

Digitalized

ECG

Input Box

 

 

 

 

 

 

 

 

 

 

 

 

The input box provides isolation circuits

to

ensure

patient

safety.

This

input box

is

also designed

 

to

reduce artifact even

if it

is

placed

up

to

10

m from

the

 

cardiograph.

Digital

Communication

Interface

 

 

 

 

 

 

 

 

 

 

 

 

The cardiograph

can

automatically file the

recorded

ECG

waveforms

and

save them

in the storage

media

(Filing function).

You

can review the ECG waveforms by

 

transferring

the

ECG files

on a personal

computer

or

other

Cardiofax

by

way of the

RS-232C

port.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stylus Scratching

Sound

Synthesizer

 

 

 

 

 

 

 

 

 

 

 

Operators can

evaluate the

quality of

ECG

recording

by

the sound

of the

stylus on

the paper.

Operator’s Manual ECG-9320

1.1

1. INTRODUCTION

| 1-2 ImportantSafetyInformation

WARNING

1. Surrounding

Conditions

 

 

 

 

 

 

 

 

 

 

e

Never

use

the cardiograph

in the

presence

of any

flammable

anesthetic

 

agents

or

environments

in which

an electrical

arc

could

igni te

an

 

 

explosion.

Failure

to follow

th is

warning

may

resu It 1 in

exp

los ion.

 

e

Avoid

direct sprinkl

ing,

spray or

mois tair

from

a

nebul

Izer

Or

hum

ΙΤΙΘΓ.

2.Grounding the Cardiograph

The cardiograph

conforms

to

Class | according

 

of IEC 601-1

(CSA

 

Risk

class 3).

e

Ground

the

cardiograph

to

protect

the

patient

and

operator from

 

 

 

 

electrical

shock.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e

Connect

the

3-prong

power

cord

provided

with

 

the

cardiograph

to

a

3-

 

contact

grounded

AC

outlet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@

Periodically

check

the

integrity

of

the

ground

at

the

AC

outlet.

 

 

 

 

e

When

several

medical

instruments

are

used

together,

ground

all

 

 

 

 

ins truments

at one-point ground

to

protect

 

the

 

pat ien

t and

operator

from

 

electrical

shock.

Failure

to

follow

th

is

warning

 

may

resu

It

In

serious

 

 

electrical

shock or the

injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Using

a Defibrillator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e

When

the cardiograph

is

used

with

a

cardiac

defibrillator,

do

not

contact

 

the electrodes to the defibrillator

paddle.

However

the

ECG

input

box

 

provi des

protect ion

agains

tacard

lac

 

defibrillator

d ISC harge.

 

 

 

 

 

e

All

persons

must

keep

clear

of

the

bed

and

must

 

not

touch

the

patient or

 

any

equipmen

t connected to the

pat len t. Fa

lure

to

follow

th

is

warning

 

may

serious

e lectr ica | burn,

shock,

or

 

other

 

injury

 

dur

ing

defibrillat

ion.

e

Do

not

use

the

CRO

output

signal

for

Synchronized

 

card

loversion

because

 

there is approx. one second time

delay between

 

the

original

signal

and

 

the

output

signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.Using an Electrosurgery Uni

When

the

cardiograph

is

used with

an

electrosurgery

un

 

 

e

Firmly attach

the

ESU's

return

plate

and the ECG electrodes to the

patient.

 

Failure

to follow

th is

warning

may

resu

It IA serious

e lectr

са | burn,

shock

 

or

other

injury.

 

 

 

 

 

 

 

 

 

 

@

Locate

ECG

electrodes

as far

as

possible

from the point of

Incision

to

reduce the hazard of burns in the event of a defect in the return plate connection.

1.2

Operator’s Manual ECG-9320

1. INTRODUCTION

1-3 Panel Descriptions

1-3-1 Top View

Г 4

 

cardio’:

P \

 

 

 

===

 

 

1 —

 

 

—,

 

.

 

 

 

4

 

 

 

 

NAN

 

TE

JT

5

[ !

I

K

 

 

L

 

|

 

 

2 |

[==

IH

=

6

cs

|

3 ST

 

 

|

C

 

NO.

 

 

 

Name

 

 

 

 

Description

1

|

LCD

touch-screen

Displays ECG waveforms, various information, marks and

 

 

 

 

 

 

touch

keys.

 

 

2

|

Magazine

release

lever

Slide

this

lever to open the magazine when loading the

 

 

 

 

 

 

recording

paper.

 

 

 

Magazine

 

 

Contains

the

recording

paper.

 

 

LCD

Brightness

control

Controls

the

brightness

of the LCD screen.

 

 

LCD

Contrast control

Controls

the

contrast of the LCD screen.

 

 

Operation

panel

 

Refer

to next

page.

 

Operator’s Manual ECG-9320

1.3

1. INTRODUCTION

1-3-2 Operation Panel

Lei)À,

0

-

2

ο

o

tm

«VR

aVL

im

„VF

E

o

o

3mat

C

VII

V4

V2)

V5

V3|

V6

οο

A

Q x1/2

DB

© og ad

10

1.4

Operator's Manual ECG-9320

1. INTRODUCTION

No.

 

 

 

 

Name

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

1

|

Battery charge

lamp

Turn

on

the

Main

power switch on the rear panel to charge the

 

 

 

 

 

 

 

battery. During battery charging, the battery charge lamp

 

 

 

 

 

 

 

 

continuously

 

lights or blinks.

 

 

 

 

 

 

 

 

2

|

Sensitivity

X

1/2 switeh/lamp

The

sensitivity

is

selected

by the Sens key on the

LCD

screen.

 

 

 

 

 

 

 

This switch reduces the selected sensitivity to half.

 

 

 

 

 

Paper

feed

switch

Feeds

the

paper

according

to

the

"Mark

on or

off"

setting in

the

 

 

 

 

 

 

 

System

Setup.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mark

on:

 

 

Feeds the paper until the next paper mark is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

detected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mark

off:

 

Feeds the

paper

while the switch is pressed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

During

manual

recording, pressing the paper feed switch

 

 

 

 

 

 

 

 

prints

the

event

mark.

 

 

 

 

 

 

 

 

 

 

 

 

AC power

lamp

 

Lights

when

the

cardiograph is operating on AC power.

 

 

 

Power

switch

 

 

Turns

the

cardiograph

on/off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

):

Turns

the

power on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(O):

Turns

the power off.

 

 

 

 

 

 

 

 

 

 

Extra

switch

/lamp

Selects

the

extra

leads.

The

lamp lights

according

to

the

 

 

 

 

 

 

 

 

selected

number

 

of channels.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp

1

and

2:

 

6

channel

recording

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp

lor

2:

 

 

3

channel

recording (channel

1 to

3

or

4 to 6)

 

 

 

Lead

selection

switch/lamp

Selects

the

lead

group.

When

manual recording

is

selected,

you

 

 

 

 

 

 

 

can select the lead group recorded on the paper.

 

 

 

 

 

 

Calibration switch

Displays

and/or

records

the calibration

waveforms.

For

 

 

 

 

 

 

 

 

external input signals, this key is not operative.

 

 

 

 

 

 

Auto/Manual

selection

Selects

automatic

recording

or manual

recording.

 

 

 

 

 

switch/lamp

 

 

 

Lampon:

 

 

automatic

recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp

off:

 

manual

recording

 

 

 

 

 

 

10

 

Start/Stop

switch/lamp

Starts

or

stops

recording.

When

recording starts,

the

lamp

 

 

 

 

 

 

 

 

lights.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operator's Manual ECG-9320

1.5

1. INTRODUCTION

1-3-3 Front Panel

|

 

 

(===

 

o

UN

 

N

cardiotax

W\ |

L

|

[DT

 

CJ

 

o

CI ey

 

 

(

 

 

 

|

 

C

 

 

 

|

 

+=

VF

^ =

 

 

1

2

3

4

5

|

 

 

 

C N

 

 

 

 

==

 

 

cardiofax

7

 

.

 

 

[|

 

 

 

 

 

E]

 

 

 

 

 

EE]

LA

C

|

When

the magnetic card reader and floppy disk unit are installed

1.6

Operator’s Manual ECG-9320

1. INTRODUCTION

No.

 

 

 

 

 

 

Name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

1

|

3.5

inch

floppy

disk drive

 

 

 

The

3.5

inch floppy disk drive is installed

here to

save

or read

 

 

 

 

 

 

 

 

 

 

 

 

 

ECG

files.

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

|IC

memory

card

slot

1

 

 

 

For

anIC

memory card and program card.

This slot is

also used

 

 

IC

memory

card

slot

2

 

 

 

to

read the

programs or data file media.

 

 

 

3

|

Eject

button

 

 

 

 

 

 

 

Press

to

eject

the

IC

memory

card.

 

 

 

 

4

|

External

signal

input

socket*

 

For

external

analog

signals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

When

connecting

an

external

instrument

to the

following

sockets

or slots with an * mark:

 

 

 

e

Ensure

that

the

external

instrument

complies

with

the

IEC601-1,

IEC601-2-25 safety

 

 

 

 

 

standard

for medical

equipment.

When

the

 

instrument

does

not

comply with IEC601-1,

 

 

 

 

IEC601-2-25, such as a personal

computer

or

 

modem,

etc.,

use

a

locally available

medical

 

 

 

 

use

isolation transformer

unit between the instrument and the AC outlet.

 

 

 

 

 

@

Attach

a

ferrite

core

to

the

cable

for

an

external

instrument.

Refer to EMC related caution

 

 

 

 

and Section 11-5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

|

ECG

input box

socket

B

 

 

 

Connects to the input box.

 

 

 

 

 

 

6

|

Magnetic

card

reader

slot

 

 

Reads

the patient information from the ID card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

The

cardiograph

should

only

be

connected

to

an

external

instrument

which

complies

with

 

 

the

CISPR 11 Second

Edition

1990-09,

Group

1

and

Class

B

standard.

 

 

 

 

Operator’s Manual ECG-9320

1.7

1. INTRODUCTION

1-3-4

 

Rear

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

When

connecting

an

external

instrument

to

the

following

sockets or slots with an * mark:

e

Ensure that

the

external

instrument

complies

with the

IEC601-1, IEC601-2-25 safety

standard

for

medical

equipment.

When

the

 

instrument

does not comply with IEC601-1,

IEC601-2-25,

such

as

a personal

computer

or

modem,

etc., use a

locally available medical

 

use

isolation

transformer

 

unit

between

the

instrument

and

the

AC

outlet.

 

 

e Attach a

ferrite

core

to the

cable for

an

external

instrument.

Refer

to EMC

related

caution

and

Section

11-5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

The

cardiograph should

only

be connected

to

an external

instrument

which

complies

with

the

CISPR 11

Second

Edition

1990-09,

Group

1

and

Class

B

standard.

 

 

 

 

4

5

6

7

11

12

8

9

10

Standard

9-2 9-1

8-2

 

8-1

 

When the slave monitor interface

board

and extension

I/O board are installed.

For pin assignment of each socket,

refer

to the Service

Manual Section 10.

1.8

Operator’s Manual ECG-9320

1. INTRODUCTION

No.

 

 

Name

 

 

 

 

 

 

Description

 

 

1

|

Main

power switch

Turns the

AC

power

supply on/off.

 

 

 

2

|

Fuse

compartment

Contains the

power

line

protection

fuses.

 

3

|

AC Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

@

Fuses

cut

the power

off when

an

abnormality occurs

in

 

 

 

 

 

the cardiograph.

Remove the

malfunction before

 

 

 

 

 

 

replacing

the fuse.

 

 

 

 

 

 

 

 

@

Before

replacing,

turn power

off

and disconnect the

AC

 

 

 

 

 

power

from the

 

cardiograph.

 

 

 

eFuse replacement should be done only by a qualified person.

 

 

 

 

 

 

 

 

 

 

 

AC

power

cord socket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connects to the power cord to supply AC power to the

 

 

 

 

 

 

 

 

 

 

 

cardiograph.

 

 

 

 

 

 

 

4

|

Input

box

socket A

 

 

Connects to the input box.

 

 

5

|

Barcode

reader

socket*

 

Connects

the

barcode

reader.

 

6

|

External

input/output

socket*

Connector for analog and digital I/O signals.

7

|

SIO

(1)

socket

1*

 

 

Connects

to the personal computer or another Cardiofax for

 

 

 

 

 

 

 

 

 

 

 

ECG

file

transfer.

 

 

 

 

 

8

|

Extension

 

I/O

board

slot*

For an Extension I/O board.

 

 

8-1

|

SIO

(2)/SIO

(3)

 

 

 

For

an

optional

external

instrument.

 

 

SIO

socket

2/3*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-2

|

Extension

 

I/O

socket*

 

For

6

channel

CRO

output

signals.

9

|

Slave

monitor

interface

board

A display

board

for

a

slave

monitor can be installed.

 

 

slot*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9-1

|

Slave

monitor

socket*

 

Connects to an slave monitor.

 

9-2

|

Color

selector

 

 

 

Selects

the display

color of the slave monitor.

10

|

Equipotential

ground

terminal

| When

the

equipotential grounding is required to ensure

 

 

 

 

 

 

 

 

 

 

 

electrical safety, connect this terminal to the equipotential

 

 

 

 

 

 

 

 

 

 

 

ground

terminal

on

the

wall

with the ground lead.

11

|

IC memory card slot 3

 

For an IC memory card and program card.

12

|

Eject

 

button

 

 

 

Press

to

eject

the IC

 

memory

card.

Operator's Manual ECG-9320

1.9

1. INTRODUCTION

1-3-5 Input Box Set

Lead off (Electrode failure) indication lamps

Input box

 

(JC-901D)

N

 

Connection

Electrode lead cartridge

cable

 

Input Box Set

1.10

Operator’s Manual ECG-9320

1. INTRODUCTION

1-4

Basic

Screen

and

Menu

Window

 

 

 

 

 

1-4-1

Basic

Screen

 

 

 

 

 

 

 

 

 

 

©

General

 

 

 

 

 

 

 

 

 

 

 

When

the

power is turned

 

on, the examination screen which is

assigned to the

top of the

 

 

menu item in the Menu window

appears.

 

 

 

 

 

The Basic screen displays the ECG waveforms, patient information, messages, marks,

 

 

selected examination name

and

touch

keys

for operation. The

screen contents

depends

 

 

on

the

selected

recording

menu,

settings, or

installed software.

 

 

 

 

©

Explanation

of the Keys

and

Marks

Displayed on the Basic Screen

 

 

4

UT

 

|

 

+—

 

v

68

1

LAMA,

Il

2

|

°

 

 

 

7

8

9

 

10

11

 

 

i

 

 

 

|

 

|

 

||

/

 

 

 

 

 

|

 

 

 

 

 

 

 

|

 

 

 

 

 

 

XXXXXXXXXXXXXXXX

 

 

o

 

 

 

 

=

x

 

-dd roba

 

 

 

 

 

 

 

mmm

 

 

 

 

 

 

γι

 

 

 

 

123456789012

 

 

|

|

 

Il

 

 

 

 

XXXXXXXXXXXXXXXXX

 

 

 

7

 

do

do in in

ln

a

Female

23Y

ID

| -13

 

 

 

 

 

 

 

 

mmm-dd-yy

 

[

|

Da

12

Ch

 

 

A

а

а

 

 

 

 

 

 

It

 

 

E

 

 

Rhythm

00

 

 

 

 

A

 

LK

10 mm/mV

3

n pe

35 Hz

 

Menu

Setup

File

Analyze Event

Rhythm

 

Disp

 

в

 

ral

17

Sens

19

Filt

 

21|

22|

23|

24|

25|

26|

1Patient A/Patient A selection key

Selects patient A. When patient A is selected, the "A" mark is highlighted.

2Waveform display area

Displays the acquired ECG waveforms or external input signals. The display time

depends

on the number

of display

leads

set

by

the Disp key on the screen or

the Extra

switch on the

operation

panel.

 

 

 

 

 

 

 

12 leads

display:

 

 

5

seconds

ECG

waveforms

 

3-lead,

6-lead,

or extra

signal display:

10seconds

ECG

waveforms and/or

external

 

 

 

 

 

input

signals

 

 

 

 

Operator’s Manual

ECG-9320

 

 

 

1.11

3 rhythm leads selected in the System Setup The same leads that are selected by the Rec key 12 leads

1. INTRODUCTION

Rhythm

lead

display

area

 

 

 

 

 

 

Displays

the

selected

20 seconds

rhythm lead. When

artifact or

electrode

detachment is detected, the affected waveform is

highlighted.

 

 

QRS

mark

 

 

 

 

 

 

 

 

Blinks synchronization with the QRS wave.

 

 

 

 

Heart

rate

 

 

 

 

 

 

 

 

Indicates

heart rate.

The heart

rate is

displayed

updated every

2

seconds.

Filing mark

key

 

 

 

 

 

 

 

 

 

"mark is

displayed

during

ECG filing

or

transferring.

To cancel

operation, press this

key.

 

 

 

 

 

 

Electrode condition message

"Electrode Failure" is displayed when the electrode is detached. "Electrode Noise" is displayed when artifact is detected.

Battery operation

mark

 

The"

m

" mark appears when

the cardiograph is operating on battery power.

When

the battery is almost discharged, this mark blinks.

Paper

empty

mark

 

 

The"

СЯ

" mark

blinks when the

paper is empty.

10 Menu name

Displays the current examination name.

11 Date and time

Displays the date and time.

12Patient B/Patient B selection key

Selects patient B. When patient B is selected, the "B" mark is highlighted.

13ID (Patient information display key)

Displays the Patient Data Input screen. After entering the patient information, ID

number, sex, age, date of birth, and name are displayed on the screen.

14Disp (Display format setting key)

Selects the number of channels displayed on the screen.

Selection list Rhythm 3ch: Sync. Rec: 12ch:

15Rec (Recording format setting key)

Selects the number of channels recorded on the paper. Selection list: 3ch, 3 with rhythm lead, 6, or 12 channel

Operator’s Manual ECG-9320

1. INTRODUCTION

16 The following messages

are

displayed here:

 

 

 

Preparation XX:

After

the

electrodes have been placed, this message

is

displayed

 

while artifact or electrode detachment

is detected.

XX

indicates

 

the elapsed time since electrode placement or the last detected.

Ready:

Displayed

when ECG recording is available.

 

 

Analysis *:

Displayed

during ECG analysis. The

* mark blinks

every second.

XX indicates the elapsed time from the start of manual recording.

17 Displays the elapsed time from the start of Rhythm recording.

18Speed (Paper speed selection key)

Selects the paper speed in manual recording.

Selection list: 25, 50 mm/s, slow speed (5, 10, 12.5mm/s)

19Sens (Sensitivity selection key) Selects the sensitivity Selection list: 5, 10, 20 mm/mV

20Filt (High-cut filter selection key)

Selects the high-cut filter to reduce the high frequency component. Selection list: 25, 35, 75, 100, on 150 Hz

During measurement, you can use one of 5 high-cut frequencies preselected in the System Setup.

21Menu (Menu key)

Calls up the Menu window.

22 Setup

Calls up the System Setup window of the currently selected examination.

23File (File key)

Calls up the File window for ECG filing and transferring.

24Analyze (ECG analysis key) / Report (Report key)

Analyze: Appears when manual ECG analysis is available. The QP-911E ECG Interpretation software (ECG interpretation result and ECG

measurement table recording) or QP-910E (ECG measurement table recording) is required. By pressing the key you can record ECG analysis result or ECG measurement table.

Report:

Appears

when

Report

recording is

available. You

can print the recording

 

results

any number

of

times until

next recording

is started.

25 Event

(Event mark

key)

 

 

 

 

 

You can record the

event

mark

on

the paper.

 

 

26Rhythm

Starts to save ECG waveform for Rhythm recording.

Operator's Manual ECG-9320

1.13

1. INTRODUCTION

© Explanation of the Error Marks and Message Displayed on the Basic Screen

Marks/messages

 

 

 

 

 

 

 

 

Explanation

 

 

 

 

Paper empty

Blinks

when

there

is no

more

recording

paper.

The current

recording

is

 

 

stopped.

 

 

 

 

 

 

 

 

 

 

 

 

Electrode

failure

The

detached

electrode

name

except

for

N is displayed

on the

screen.

If

 

 

two

or

more

electrodes,

except

for N,

are

detached the

"Electrode Failure

 

 

Limb"

message

appears

on the top of

the screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

If a

limb

electrode

is detached, the cardiograph

cannot

detect chest

 

 

 

electrode

detachment.

 

 

 

 

 

 

 

 

 

 

The rhythm lead waveform is highlighted when electrode detachment or

 

 

artifact

is detected.

 

 

 

 

 

 

 

 

 

Electrode

Noise limb

Appears

when

artifact

is detected on

the

electrode.

 

 

 

or chest (electrode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

name)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operator’s Manual ECG-9320

Loading...
+ 195 hidden pages