NETGEAR EN104, EN108, EN116 User Manual

Start Here

Congratulations on your purchase of the NETGEAR™ Model EN104, Model EN108, or Model EN116 Ethernet hub. The hubs deliver standards-based, plug-and-play networking solutions for small businesses, home offices, and low-density workgroups of larger companies
.
In this installation guide, all three hubs are referred to collectively as the Model EN104/EN108/ EN116 hub. Each hub is listed individually when information is provided that refers to a specific model.

Features

The Model EN104/EN 108/EN116 hub has the following features:
Four (on t he Mod el EN104 h ub), e igh t (on t he Mod el EN1 08 hu b) , and si xt een (on the Model EN116 hub) vi sta 10BASE-T network ports (RJ-45) that provide 10 megabit per second (Mbps) networking using simple unshielded tw isted pair (UTP) wiring
Built-in LED indicators for at-a-glance status checks by vista networks ports
AUI (not on the Model EN104 hub) or coaxial BNC backbone support for connecting to an existi ng Ethernet se gment or external transceiv er, or for network expansion by connecting multiple hubs together using twisted pair or coaxial cabling
Uplink port for connecting to other hubs using simple straight-through cables
Clear front-panel light-emitting diode (LED) indicato rs to monitor overall hub status
Plug-and-play installation with no software to configure
Complete hub functions including pack et retimin g , collision detection, preamble regener ation, and fragment extension
Automatic partitioning and r econnection of a port that has excessi ve colli sions or is jabbering
Automatic polarity detectio n for recognizing and corr ecting incor rect polarity on the rec eive pair
Compact design, enabling easy tabletop or rack-mounting installation
External power adapter
Limited five -year warranty on the uni t and one-year warranty on the power supply

Package Con te nt s

Model EN104 hub
Pwr Col
Pwr Col
1234 5678
Mounting kit
Installation guide,
Warranty & Owner
Registration Card,
Support Information
Card
Model EN104/EN108/EN11 6 Ethernet Hub Installation Gui de
or
10 BASE-T HUB
EN104
LINK Rx
or
Model EN116 hub
10 BASE-T HUB
EN116
1234 5678
Model EN108 hub
10 BASE-T HUB
EN108
Pwr Col
1234 5678
LINK Rx
LINK Rx
Power adapter and cord
8731FA
Verify that your package contains the following:
Model EN104 hub, Model EN108 hub, or Model EN116 hub
Mounting kit (for wall installation)
BNC T-connector and BNC 50 Ω terminator (only if you have purchased the Model EN108 hub or the Model EN116 hub)
This insta llation guide
Warranty & Owner Registration Card
Support Inf ormation Card
Power adapter and cord

Product Illustration

Front Panel of the Model EN104 hub
10BASE-T ports
10 BASE-T HUB
EN104
Pwr (Power)
Col (Collision)
Pwr Col
Front Panel of the Model EN108 hub
LINK Rx
Normal/Uplink push button
10 BASE-T HUB
Pwr Col
EN108
1234 5678
LINK Rx
Front Panel of the Model EN116 hub
10 BASE-T HUB
Pwr Col
EN116
1234 5678
1234 5678
LINK Rx
8732FA

Vista 10BASE-T Network Ports with Built-in LEDs

The front panel of the Model EN104 hub has four RJ-45 10BASE-T ports, the Model EN108 hub has eight RJ-45 10BASE-T ports, and the Model EN116 hub has sixteen RJ-45 10BASE-T ports. Two LEDs—the Link LED and the Rx LED—are built into each 10BASE-T port.
Link LEDRxLED
8724EA
Model EN104/EN108/EN11 6 Ethernet Hub Installation Gui de

LEDs

The table below describes the activity of the LED s.
Label Color Activity Description
Pwr (Power) Green On Power is supplied to the hub. Col (Colli si on ) Amber Blinki ng Data c ol li si on i s occ ur rin g o n t he ne tw ork. No te
Link (located on the top left corn er of ea ch vista 10BASE-T por t )
Rx (located on the top right
corn er of ea ch vista 10BASE-T por t )
Active (for BNC)
Rx (for BNC)
Active (for AUI)
Rx (for AUI)
Green On T he link between this port and the connect ed
Green Blinking There is incoming data on the port.
Green On The link between the BNC port and the
Green Blinking There is incoming data on the BNC port.
Green On The link between the AUI port and the
Green Blinking There is incoming data on the AUI port.
that oc casional collisions are normal.
device is good.
connected device is good.
connected device is good.

Normal/Uplink Push Button

The Normal/Uplink push button allows you to select Normal (MDI-X) wiring for direct PC connection. The push button also allows you to select Uplink (MDI) wiring for connection to a hub or a switch through port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the Model EN116 hub. This uplink configuration eli minates the need to use a crossover cable. The other 10BASE-T ports are pe rm anently configured for normal wiring for connection to a PC.

Rear Panel

The rear panel of the hub has a BNC port that you can use to connect to a backbone network or other PCs using thin coaxial cable.
The rear panel of the Model EN108 hub and the Model EN116 hub also has an AUI port in addition to the BNC port. You can use the AUI port w ith the appropriate transceiver to connect the hub to a backbone network using thin coaxial cable, thick coaxial cable, fiber optic cable, or 10BASE-T wiring.
Model EN104/EN108/EN11 6 Ethernet Hub Installation Gui de
The rear panel also includes a DC power receptacle.
The rear panel also includes a DC power receptacle.
BNC port LEDs
BNC port LEDs
BNC port
BNC port
12Vdc 1.2A
12Vdc 1.2A
Active
Active
BNC
BNC
Rx
Rx
+
– +
Rear Panel of the Model EN104 hub
Rear Panel of the Model EN104 hub
AUI port LEDs
AUI port LEDs
AUI port
AUI port
AUI
AUI
Active
Active
Active
Rx
Rx
Rear Panel of the Model EN108 hub
Rear Panel of the Model EN108 hub
Rear Panel of the Model EN116 hub
Rear Panel of the Model EN116 hub
Active
Rx
Rx
AUI
AUI
Active
Active
Rx
Rx
12Vdc 1.2A
12Vdc 1.2A
BNC
BNC
+
– +
Power receptacle
Power receptacle
BNC
BNC
Active
Active
Rx
Rx
12Vdc 1.2A
12Vdc 1.2A
+
– +
8738FA
8738FA
Installation Pr ocedures

Installation Pr ocedures

Prepare the Site

Prepare the Site

Before you begin installing your hub, prepare the installation site. Make sure your operating
Before you begin installing your hub, prepare the installation site. Make sure your operating envi ronment meets the operating environment requirements of the equipment.
envi ronment meets the operating environment requirements of the equipment.
Characteristic Requirement
Characteristic Requirement
Temperature Ambien t temperature between 0° and 40° C (32° and 104° F).
Temperature Ambien t temperature between 0° and 40° C (32° and 104° F).
No nearby heat sources such as direct sunlight, warm air exhausts,
No nearby heat sources such as direct sunlight, warm air exhausts, or heaters.
or heaters.
Opera ting humidity Maximum relative humidity of 90%, noncondensing.
Opera ting humidity Maximum relative humidity of 90%, noncondensing. Ventilation Minimu m 2 inches (5.08 cm) on all sides for cooling.
Ventilation Minimu m 2 inches (5.08 cm) on all sides for cooling.
Adequate airflow in roo m or wiring cl oset.
Adequate airflow in roo m or wiring cl oset.
Opera ting conditions At least 6 feet (1.83 m) to nearest source of electromagnet ic noise
Opera ting conditions At least 6 feet (1.83 m) to nearest source of electromagnet ic noise
Service access Minimum 12 inches (19.68 cm) front and back for service access
Service access Minimum 12 inches (19.68 cm) front and back for service access
Power Adequate power source within 6 feet (1.83 m).
Power Adequate power source within 6 feet (1.83 m). Wiring hardware Wiring hardware, such as punchdown blocks or patch panels,
Wiring hardware Wiring hardware, such as punchdown blocks or patch panels,
(such a s photocopy machine or arc welder).
(such a s photocopy machine or arc welder).
and maintenance. Front and back clearance for cables and wiring
and maintenance. Front and back clearance for cables and wiring hardware such as punchdown blocks.
hardware such as punchdown blocks.
should be complete bef ore installing the hub.
should be complete bef ore installing the hub.
Model EN104/EN108/EN11 6 Ethernet Hub Installation Gui de
Loading...