Page 1
Installation and Assembly: Full Service Video Wall Mount
Model: PD02VW MFS 46 55 P
Designed for NEC MultiSync® 46” and 55” XUN/V, XS and P Series Manufactured by Peerless-AV
1 of 11
Max UL Load Capacity:
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 2
NOTE: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum UL Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
Metal Stud Contact Qualifi ed Professional (not evaluated by UL)
Brick Contact Qualifi ed Professional (not evaluated by UL)
Other or unsure? Contact Qualifi ed Professional (not evaluated by UL)
Tools Needed for Assembly
stud nder ("edge to edge" stud nder is recommended)
phillips screwdriver
drill
• 5/16" (8 mm) bit for concrete and cinder block wall
• 5/32" (4 mm) bit for wood stud wall
level
Accessories
RK02 MFS Cable Release Kit
• CK02## Wall Plate Connector Kits
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Stud Wall ................................................................................................................................................4
Installation to Solid Concrete or Cinder Block ........................................................................................................................5
Installing Tilt Brackets .............................................................................................................................................................6
Display Adjustment ............................................................................................................ .......................................... 7 and 8
Mounting and Removing Flat Panel Display.............................................................................................................. 9 and 10
2 of 11
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 3
PartsList
Description Qty. Part#
A pullͲoutmountassembly 1 145ͲT1668 B adapterbracket 2 145ͲT1670 C meshsleeve(notshown) 1 600Ͳ1014 D M5x10mmsocketpintypeͲFscrew 2 520Ͳ1164
E #14x2.5"hexheadwoodscrew 45S1Ͳ015ͲC03
F concreteanchor 4 590Ͳ0320 G fenderwasher 4 540Ͳ1008 H nylonshoulderwasher 4 590Ͳ2233
I M6x J M8x15mmsocketpinscrew 4 520Ͳ1068
K 4mmallenwrench 1 560Ͳ9646
L cabletie(notshown) 2 560Ͳ9711
12mmsocketpinscrew 4 520Ͳ1050
A
B
G
J
K
H
D EF
I
3 of 11
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 4
Installation to Wall Stud
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Tighten wood screws so screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install­ers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended.
1
Based on their edges, draw a vertical line down the stud center. Place pull-out mount assembly (A) on wall as a template. Level plate, and mark the center of the four mounting holes. Make sure that the mounting holes are on the stud center line. Drill four 5/32" (4 mm) dia. holes 2-1/2" (64 mm) deep. Make sure that the pull-out mount assembly (A) is level, secure it using four #14 x 2.5" wood screws (E) and fender washers (G) as shown below.
that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the
WOOD STUD
E
G
4 of 11
A
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 5
Installation to Solid Concrete or Cinder Block
WARNING
• When installing wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a ham- mer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
Make sure that pull-out mount assembly (A) is level,
1
use it as a template to mark four mounting holes. Drill four 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (F) in holes ush with wall as shown (right). Place pull-out mount assembly (A) over anchors and secure with four #14 x 2.5" screws (E), and fender washers (G). Level, then tighten all fasteners.
WARNING
• Tighten screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly to load-bearing concrete.
• Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable, (not evaluated by UL) the fi nishing surface must be counter bored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).
E
SOLID CONCRETE
F
CINDER BLOCK
G
A
1
concrete surface
F
Drill holes and insert anchors (F).
2
Place plate (A) over anchors (E) and secure with screws (F).
A
E
F
INCORRECT CORRECT
wall
plate
plaster/
CUTAWAY VIEW
dry wall
concrete
wall
plate
plaster/ dry wall
concrete
5 of 11
3
Tighten all fasteners.
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 6
Attaching Adapter Brackets to Display
Attach adapter brackets (B) to back of display using four M6 x 12 mm socket pin screws (I) with nylon shoulder
2
washer (H), or four M8 x 15 mm socket pin screws (J) as shown below.
DISPLAY
B
MAX VESA-400 mm MIN VESA-200 mm
H
I or J
400 mm
200 mm
300 mm
600 mm
Attaching Adapter Brackets to Display Carriage
Attach adapter brackets (B) to display carriage. Slide adapter brackets (B) into position.
3
Loosely fasten in place using security screw as shown in detail 1. NOTE: Once display is located in desired position, tighten security screws using 4mm allen wrench (K) to lock in place.
DISPLAY CARRIAGE
DETAIL 1
B
B
6 of 11
SECURITY SCREW
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 7
Pull Out Mount Assembly Adjustment
Use legend below to determine position of display.
4
NOTE: Each knob can be adjusted independently for fi ne tuning adjustments.
Turn knob CLOCKWISE to raise side Turn knob COUNTER-CLOCKWISE to lower side
UP
ROTATE LEFT
ROTATE RIGHT
7 of 11
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 8
Adapter Bracket Adjustment
Use legend below to determine position of display.
5
NOTE: Each knob can be adjusted independently for fi ne tuning adjustments.
Turn knob CLOCKWISE to move corner toward the wall
Turn knob COUNTER-CLOCKWISE to move corner away from the wall
IN OUT
BACK
BACK
TILT FORWARD
BACK
TILT BACKWARD TILT RIGHT TILT LEFT
BACKBACK BACK
8 of 11
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 9
Cable Management
Display cables can be routed through top or bottom of pull-out mount assembly (A).
6
NOTE: Use mesh sleeve (M) and cable ties (L) for cable management. NOTE: Cable ties and cable management slots on pull-out mount assembly (A) can be used to secure display
cables.
CABLE MANAGEMENT SLOTS
A
DETAIL 3
Open and Close Pull Out Mount Assembly
Open pull-out mount assembly (A) by releasing locking tab. Push or pull up on locking tab as shown below.
7
NOTE: Extended position is for service access only. The mount must be closed during normal use and operation.
A
LOCKING T AB
PULL UP
9 of 11
LOCKING T AB
PUSH UP
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 10
Open Adapter Brackets
Open adapter brackets (B) by pulling down on front release strap while pulling bottom of display away from wall.
8
NOTE: Once front release strap is pulled, adapter brackets (B) kick stand will engage. NOTE: Extended position is for service access only. The mount must be closed during normal use and operation.
DISPLAY NOT SHOWN FOR CLARITY
B
KICK STAND
B
FRONT RELEASE STRAP
DISPLAY NOT SHOWN FOR CLARITY
Close Adapter Brackets
Slightly pull display away from wall to release kick stand while pulling down on back release straps on adapter brackets (B) as shown below. Support the display until the adapter brackets (B) are engaged in the closed position. NOTE: Once back release strap is pulled, adapter brackets (B) kick stand will disengage.
DISPLAY NOT SHOWN FOR CLARITY
B
B
BACK RELEASE STRAP
10 of 11
KICK STAND
DISPLAY NOT SHOWN FOR CLARITY
ISSUED: 02-19-13 SHEET #: 145-9018-1
Page 11
Pull-Out Mount Assembly (Optional) Security
To prevent locking tabs from releasing, secure using two M5 x 10 mm socket pin type-F screws (D).
9
D
LOCKING T AB
11 of 11
ISSUED: 02-19-13 SHEET #: 145-9018-1
Loading...