Mobi Technologies DualScan prime Instruction Manual

70121
Meijer.com
TM
TM
TM
DualScan
DualScan
DualScan
PRIME
PRIME
PRIME
Ear and Forehead
THERMOMETER
Please Read this Instruction Manual Before Use
also
reads
Food
or Bottle
temperature
User’s Manual for DualScan™ Prime Digital Thermometer
Meijer.com
INTRODUCTION
Thank you for purchasing the DualScan Prime Thermometer from Mobi Technologies, Inc. The thermometer has been carefully developed for accurate, safe and fast human body temperature measurements from forehead or ear readings and object temperature measurements to ensure safe temperatures.
SAFETY PRECAUTIONS
Research indicates that the ear is an ideal site for taking body temperature. Because body temperature is regulated by the hypothalamus, which shares the same blood supply as the tympanic membrane, we recommend that you use the ear temperature mode as often as possible.
However, as with any thermometer, proper technique is critical to obtaining accurate temperatures. Therefore, in order to obtain an accurate measurement, please read this manual carefully before using.
tUse of this thermometer is not intended as a substitution for consultation with your physician. Measurement results are for reference only. Contact your physician if you have or suspect any health concerns.
tThe Infrared sensor must be kept clean, dry, and undamaged at all times to ensure accurate measurements.
2
SAFETY PRECAUTIONS (cont.)
Meijer.com
tEarwax in the ear canal or lipid on the fore­head may cause an inaccurate measurement, so make sure the ear canal or forehead is clean.
tIf you clean the ear or forehead, please wait 5~10 minutes before measuring.
tDon't touch or blow on the infrared sensor. A dirtied infrared sensor may cause inaccuracy.
tDo not use this thermometer for measure-
KEEP INFRARED SENSOR CLEAN
ments other than human body temperature, except for the object measurements allowable when in “object” mode.
tAvoid measuring the ear temperature if the ear is inamed or infected. The temperature of the unit’s storage area may dier from that of the measuring room’s temperature, so please wait for the thermometer temperature to adjust to the room temperature about 30 minutes before use. Keep the thermometer out of the reach of children.
tDon't throw batteries into re. Batteries are likely to explode in re, which could pose serious danger.
tDon't store the thermometer to temperature extremes (below -20°C/-4°F or
GOOD
NOT GOOD
over 55°C/131°F ) or humidity extremes (below 10%RH or over 90%RH); otherwise it may cause inaccuracy.
tDon't use the product in a wet ear canal after swimming or bathing. It is possible to damage the ear canal.
tDon't use the thermometer if the main body is damaged (for example, the infrared sensor is broken). The continuous use of a damaged unit may cause injury, improper results, or other serious danger.
3
3
4"'&5:13&$"65*0/4DPOU
Meijer.com
tDon't take apart, repair or change any parts of the unit at any time.
tDon't use a mobile phone nearby when the thermometer is working. If your
thermometer will not be used on a regular basis, remove batteries to prevent possible damage due to chemical leakage. If battery does leak, remove carefully.
tDo not allow bare skin to touch leaking uid.
tThis product needs special precautions regarding EMC and needs to be installed
and put into service according to the EMC information provided, and this unit can also be aected by portable and mobile RF communications equipment.
Caution:
This instrument should not be used adjacent to or stacked with other sensing, measuring, or medical equipment, and if adjacent or stacked use is necessary, this machine should be observed to verify that is operating normally for the uses for which it is intended.
/05&40/#0%:5&.1&3"563&
Normal body temperature varies. A person's normal temperature range tends to decrease with age. The following table shows normal temperature ranges by age: Normal temperature ranges by age:
0 – 2 years 36.4 – 38.0 °C 97.5 – 100.4 °F 3 – 10 years 36.1 – 37.8 °C 97.0 – 100.0 °F 11 – 65 years 35.9 – 37.6 °C 96.6 – 99.7 °F > 65 years 35.8 – 37.5 °C 96.4 – 99.5 °F
The normal temperature range varies from person to person and can be inuenced by many factors such as time of day, measuring from dierent sites, level of activity, medications, emotional condition and more.
We recommend that you practice with the thermometer on yourself and others when you are healthy. This way you know how the thermometer works and can feel more condent of the measurements you take when a family member is ill.
4
PACKAGE COMPONENTS
Meijer.com
DualScan Prime Thermometer
1.5V Battery(AAA) User manual
INTERFACE LAYOUT
1) Forehead Button
2) Food / Object Button
3) Ear Button
4) LCD Display Screen
1 piece 2 pieces 1 piece
5) Memory Button
6) Settings Button
7) Infrared Sensor Tip
8) Forehead Probe Cover
9) Battery Cover
ཱ ི
MEM
SET
5
LCD DISPLAY LAYOUT
Meijer.com
ི
ཱཱིུུ
1) Current Year Display
2) Temperature Display (ºF or ºC)
3) Indicates a Forehead Temperature Measurement
4) Indicates an Ear Temperature Measurement
5) Indicates Object or Food Temperature Measurement
6) Indicates Room Temperature Measurement
7) Low Battery Indicator
8) Memory Indicator
9) AM / PM Indicator
6
NOTES BEFORE USE
Meijer.com
1. To achieve accurate measurements, it is very important to ensure that the infrared sensor is clean before using. To clean the sensor, gently wipe its surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab. After cleaning, allow at least 20 minutes drying time before taking temperatures.
2. Earwax in the ear canal or moisture on the forehead may cause an inaccurate measurement, so make sure the ear canal or forehead is clean. If you clean the ear or forehead, please wait for 5 to10 minutes before measuring.
3. If the temperature of the units storage area diers substantially from that of the measuring room’s, please wait for the thermometer temperature to adjust to the measuring room temperature for about 30 minutes before measuring.
4. Please open the battery cover and move the plastic insulating tab away when you use the thermometer for the rst time, and then the ther­mometer will turn on automatically, as per the LCD display in the left gure. Press any button to turn unit on when unit was previously o.
Start-up screen with time displayed.