3. Above values are as follows.
Indoor Unit1 phase 240V 50Hz
Outdoor Unit1 phase 240V 50Hz
Indoor
32¡C DB, 23¡C WB
21¡C DB, 15¡C WB
27¡C DB
20¡C DB
Outdoor
43¡C DB
-5¡C DB
24¡C DB, 18¡C WB
-5¡C DB, -6¡C WB
Upper limit
Lower limit
Upper limit
Lower limit
Cooling
Heating
CHARGELESS SYSTEM
PRE-CHARGED REFRIGERANT IS SUPPLIED
FOR UP TO 30m PIPING LENGTH AT
SHIPMENT.
The unique refrigerant circuit and a large accumulator
always control the optimal refrigerant level regardless of
the length (50m max. and 5m min.) of piping. The
additional refrigerant charging work during installation
often causes problems. Therefore, it is completely
eliminated. This unique system improves the quality and
reliability of the work done. It also helps to speed up the
installation work.
2SPECIFICATIONS
2
Page 3
3DATA
Service Ref.
5m10m15m20m25m
Refrigerant pipimg length (one way)
30m35m40m45m50m
3.5PUH-4VKSA.UK3.63.83.94.14.24.44.54.64.8
Outdoor unitPUH-4VKSA.UK
NH56VNDTCompressor Model
0.64
1.55
—
U-V
(R-C)
Winding
Resistance
(')
at 20-C
U-W
(R-C)
W-V
1. REFILLING REFRIGERANT CHARGE (R-22 : kg)
2. COMPRESSOR TECHNICAL DATA
3
Page 4
15010
1000For 10 units or less
300
Outdoor Unit-Necessary surrounding clearance
(Concentrated installation)
Outdoor Unit-Necessary surrounding clearance
The upper side must be open.
Handle
for moving
138
95
Rear piping hole
23
33
Rear fresh
air intake
Side air intake
724(1)295(11-5/8)
Outlet guide
installation hole
302
Air intake
Air intake
Air outlet
870(34-1/4)
185
(7-9/32)
185
(7-9/32)
500(19-11/16)
330(13)
362(14-1/4)
1715
39.5 27.5
Terminal block for
indoor and outdoor
unit connection
Terminal block for power line
and Ground terminal
300
10
10
10
Note:Allow adequate
upper clearance
100
500
500
Service space
Handle for moving
52461
585
83524
345
382
403
959
1258(49-1/2)
4060524
Service panel
Handle
for moving
Refrigerant-pipe flared
connection [19.05 3/4F
Refrigerant-pipe flared
connection [9.52 3/8F
Knock out hole
for front piping
(refrigerant,drainage
and wiring)
Knock out hole
for right piping
(refrigerant,
drainage and wiring)
R20
R20
60
120
4553
25 max.
Knock out holes for
power line 2-[27
Standard bolt length
65
Front right piping holes-
detail figures
80
17
52
57
12
R6
104
39
Bottom
piping hole
2-U-shaped
notched
holes
Drain hole
Drain hole
2-12o23 Oval holes
(standard bolt M10)
Front opening
4OUTLINES AND DIMENSIONS
PUH-4VKSA·UKUnit : mm (inch)
4
Page 5
5WIRING DIAGRAM
DISCHARGE PIPE THERMOSTAT26C
LED(CHECK,SERVICE)
LD1-LD8<O.B>
FUSE(6A)F<O.B>
FAN CONTROLLERFC<O.B>
COMPRESSOR CAPACITOR C2
C1FAN MOTOR CAPACITOR
CRANKCASE HEATERHC
CONNECTOR(TRANSFORMER)
CN4T<O.B>
WIRES INDOOR/OUTDOOR)
CONNECTOR(CONNECTINGCN3<O.B>
NAMESYMBOL
EARTH
CRANKCASE HEATER RELAYX11<O.B>
OUTDOOR COIL THERMISTORTH
TERMINAL BLOCKTB1,3
TRANSFORMERT
SELECT SWITCH(CHECK,SERVICE)
SW1 • 2 • 3<O.B>
SOLENOID COIL(BYPASS VALVE)21R
OUTDOOR CONTROLLER BOARD
O.B
MF
MC
FAN MOTOR
COMPRESSOR
NAMESYMBOL
HIGH PRESSURE RELAYX16
PROTECT HIGH PRESSURE SWITCH
63H2
CONTROL HIGH PRESSURE SWITCH
63H1
COMPRESSOR CONTACTOR52C
4-WAY VALVE SOLENOID COIL21S4
SURGE ABSORBERZNR<O.B>
SOLENOID COIL RELAYX14<O.B>
SOLENOID COIL RELAY
COMPRESSOR RELAY
X13<O.B>
X12<O.B>
NAMESYMBOL
TO INDOOR UNIT
CONNECTING WIRES
DC 12V
TB3
BRN
ORN
YLW
3
2
1
LED
O.B
LD8
LD7
LD6
LD5
LD4
LD3
LD2THLD1
CN2
12
ON
OFF
SW3
SW2
SW1
CN3
1
2
3
1234
CN4
X11X12X13X14
X11X12X13X14
220V
230V
240V
RED
ORN
YLW
T
AC12.3V
AC
12.3V
BRN
BRN
RED
RED
4
123
CN4T
4
POWER SUPPLY
~
(1PHASE)
220
-
240V 50Hz
N
L
TB1
RED
BLU
RED
BLU
GRN/YLW
RED
C2
S
C
R
RED
WHT
BLK
MC
52C
T3/6
T1/2
L3/5
L1/1
2
6
8
7
GRY
GRY
63H2
X16
X16
GRY
A2
52C
A1
GRY
GRY
HC
WHT
WHT
BLU
BLU
RED
RED
WHT
WHT
F
ZNR
CH52C21S4TRFSV
21R
21
S4
26C
5
1
VLT
VLT
X16
63H2
BLU
BLUBLU
63H1
BLK
BLK
YLW
YLW
BRN
BRN
RST
26C
63H1
51CM
5
MF2
RED
C1
ORN
RED
BLU
WHT
ORN
BLU
WHT
F. C
MF1
1
2
4
3
MF
BRN
C1
YLW
BRN
BLU
WHT
YLW
BLU
WHT
MF
1
2
4
3
26C Overheat protection
63H2 functions
(when both No.1 and No.2 of SW3 are "OFF")
Check Display (flashing)
TH overheat protection
Defective input
Pipe sensor short/open
Compressor indoor command
Crankcase heater ON
Bypass valveON
4-way valveON
Outdoor fanON
CompressorON
63H1ON
Heating indoor command
Output Display (light)
LD8
LD7
LD6
LD5
LD4
LD3
LD2
LD1
LED No.
Main functions of LED
● The output display (light) remains during operation
in flashing mode. Pressing the switch again returns
How to use SW1 and SW2
but pressing SW2 displays the past check contents
to output display(light).
stored on the microcomputer.
● Pressing SW1 erases the past check contents
NOTE: If the operation of the protection device stops to function, then check the display flashes.
● Since the indoor and outdoor connecting wires have polarity,make sure to connect the same terminal numbers(1,2,3)for indoor and outdoor units.
●
Since LD8 lights when normal power is turned "ON", check the power supply with the ON or OFF LD8.
w Since the outdoor transformer (T) is connected with 240V power, if 220V or 230V power is used,
change the wiring connections according to the following procedure.
CAUTION FOR INDOOR AND OUTDOOR CONNECTING WIRES
CAUTIONS FOR POWER SUPPLY WIRING
● Connect the lead wires according to the colour indication of the sticker on the compressor terminal.
CAUTION FOR SERVICING
REDWHITE
220V
YELLOW
240V
w When Power Supply is 220V
230V
ORANGE
PUH-4VKSA·UK
5
Page 6
6REFRIGERANT SYSTEM DIAGRAM
Indoor unit
Outdoor unit
Indoor
heat
exchanger
Thermistor
(TH2)
Strainer
Flexible tube
Service
port
(check)
Accumulator
Ball valve
Strainer
Compressor
Refrigerant pipe
(option)
19.05A({3/4")
(with heat insulator)
Refrigerant pipe
(option)
9.52A({3/8")
(with heat insulator)
Ball valve
(with service port)
Strainer
Bypass
valve
Restrictor
valve
4-way valve
Oil separator
Service
port
High pressure
Control switch
Protective high
pressure switch
Outdoor heat exchanger
Thermistor
TH3
W1(O.D.3.2OI.D.2.0-R820)O2pcs
Distributor
with
strainer
Restrictor
valve
Capillary
tube
Flared
connection
Refrigerant flow in cooling
Refrigerant flow in heating
Thermal
switch
(Discharge)
Capillary
tube W1
PUH-4VKSA·UK
Unit : mm
6
Page 7
7DISASSEMBLY PROCEDURE
PUH-4VKSA·UK
OPERATING PROCEDUREPHOTOS
1. Removing the electrical parts
(1)
Remove the 3 screws at the front and 2 screws at the
rear of the top panel.
(2)
Remove the top panel.
(3)
Remove the screw from the panel cover. Unhook the
catches from the side panel and pull the panel cover
toward you to remove.
(4)
Remove the screw from the service panel. Pull down
the service panel to unhook the catches. Pull the
service panel toward you to remove.
Photo 1
Screws
Panel cover
Photo 2
2. Removing the fan motors
(1)
Remove the 3 screws and the front panel.
Open the panel to a 45-degree angle and lift it to
remove. The panel is hooked by 3 catches on the left
side.
(2)
Remove the propeller nuts and the propellers.
(3)
Remove the 3 screws each and the fan motors.
Disconnect the lead connectors.
Screws
Photo 3
Motor support
Terminal block
Separator support plate
High pressure
switch
Propeller
nut
Propeller
7
Valve bed
Page 8
OPERATING PROCEDUREPHOTOS
3. Removing the heat exchanger and the compressor
NOTE :When removing the panels, move them up and down
to unhook catches.
(1)
Remove the rear panel set screws : 2 screws at the
front, 1 screw on the side, and 3 screws at the rear.
(2)
Remove the valve bed.
(3)
Open the rear panel rearward to remove.
(4)
Remove the 4 screws of the right side panel and
remove it.
(5)
Remove the 3 screws of the rear guard and remove it.
(6)
Remove the 4screws of the separator support plate
and remove it.
(7)
Remove the 2 screws of the motor support and
remove it.
(8)
Remove the 5 screws of the valve bed. Lift the valve
bed to unhook the catches on both sides.
(9)
Remove the electrical parts box.
)
(
Disconnect the connectors of the high-pressure
10
switch, crankcase heater, shell thermo, and fan motor.
(11)
Remove the 2 screws of the separator and remove it.
(12)
Remove the 2 screws of the heat exchanger and
remove it.
(13)
Detach the brazed points of the pipe.
(14)
Remove the 3 nuts of the compressor and remove it.
(15)
Detach the welded points of the suction pipe and
discharge pipe.
Photo 4
Screws
Screws
Photo 5
Heat exchanger
Photo 6
8
Charge plug
Ball valve
Compressor
Accumulator
Page 9
8PARTS LIST
STRUCTURAL PARTS
PUH-4VKSA·UK
12
10
13
1
14
96
7
3
2
4
3
4
No.
Part No.
1
S70 020 641
2
S70 004 668
3
S70 001 675
4
S70 A00 655
5
S70 004 661
6
S70 040 662
7
S70 040 682
8
S70 020 658
9
S70 040 698
10
S70 050 130
11
S70 001 686
12
13
14
11
Q'ty/set
Part name
TOP PANEL
FRONT PANEL
FAN GUARD
PANEL HANDLE
SERVICE PANEL
SIDE PANEL
REAR PANEL
PANEL COVER
REAR GUARD
MOTOR SUPPORT