Mitsubishi Electric MS-A18WV, MS-A24WV, MS-A30WV, MSH-A18WV, MSH-A24WV Operating Instructions Manual

...
SNOITCURTSNI GNITAREPO
SNOITCURTSNI GNITAREPO sremotsuc roF
snoitcurtsni gnitarepo siht daer ot erus eb ,ylefas dna yltcerroc tinu siht esu oT
.esu erofeb
English
ENCLOSURE
AIR OUTLET
This air conditioner is NOT intended for use by children or infirm persons without supervisions.
Do not use intermediate connection of the power supply cord or the extension cord and do not connect many devices to one AC outlet.
• A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Do not scratch or process the power supply cord, etc.
• Do not put heavy object on the power supply cord and do not scratch or process the cord. The cord may be damaged and this may cause a fire or an electric shock.
Do not turn the breaker off/on or disconnect/connect the power supply plug during operation.
• This may cause a fire due to spark, etc.
• Be sure to turn off the breaker or disconnect the power supply plug absolutely after switching the indoor unit off with the remote controller.
Do not expose your skin directly to cool air for a long time.
• This could damage your health.
The customer should not install this unit.
• If this is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc. Consult your dealer.
Do not insert your finger or a stick, etc. into the air inlet/outlet.
• Since the fan rotates at high speed, this may cause an injury.
• Young children should be supervised to ensure that they do not play with the air conditioner.
When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power supply plug or turn off the breaker.
• If the unit continues to be operated in an abnormal condition, it may cause a fire, trouble, etc. In this case, consult your dealer.
Repairs or relocation should not be done by the customer.
• If this is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc. Consult your dealer.
• If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard.
When the air filter is to be removed, do not touch the metal parts of the indoor unit.
• This may cause an injury.
Do not use an insecticide or flammable spray.
• This may cause a fire or deformation of the cabinet.
Do not put a pet or houseplant where it will be exposed to direct airflow.
• This could injure the pet or plant.
Do not leave the unit on an installation stand which is damaged.
• The unit may fall and this may cause an injury.
Do not step onto an unstable bench when maintaining the unit, etc.
• This may cause an injury, etc. if you fall down.
Do not pull the power supply cord.
• The core wire of the power supply cord may be disconnected and this may cause a fire.
Do not charge or disassemble the batteries and do not throw them into a fire.
• This may result in leakage, fire or an explosion.
Do not operate the unit for a long time in high humidity, e.g. leaving a door or window open.
• In the cooling mode, if the unit is operated in a room with high humidity (80% RH or more) for a long time, water condensed in the air conditioner may drop and wet or damage furniture, etc.
Do not use the unit for special purposes.
• Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects. This may cause deterioration of quality, etc.
Do not put a stove, etc. where they are exposed to direct airflow.
• This may cause imperfect combustion.
WARNING
CAUTION
3
NAME OF EACH PART
Indoor unit
Outdoor unit
Air cleaning filter (White bellows type) (OPTION)
Vertical vane
Operation section
(When the front panel is opened)
Front panel
Air inlet
to Breaker
Power supply cord
Remote control receiving section
Display section
Emergency operation switch
Horizontal vane
Remote controller
Operation Indicator
Remote control receiving section
Operation Indicator lamp
MUH-A24WV MU-A30WV MUH-A30WV
MU-A18WV MUH-A18WV MU-A24WV
Air inlet (back and side)
Piping
Drainage hose
Air outlet
Drain outlet
Catechin air filter
FAN
TOO
WARM
TOO
COOL
VANE
STOP
START
HR.
MIN.
WIDE VANE
LONG
COOL
DRY
AMPM
CLOCK
˚C
AMPM
RESET CLOCK
MODE
I FEEL
COOL
DRYFAN
TOO
COOL
AMPM
CLOCK
˚C
AMPM
TOO
WARM
AMPM
CLOCK
˚C
AMPM
Temperature buttons
PREPARATION BEFORE OPERATION
Auto restart function
These models are equipped with an auto restart function. If you do not want to use this function, please consult the service representative because the setting of the unit needs to be changed.
Auto restart function is ...
When the indoor unit is controlled with the remote controller, the operation mode, the set temperature and the fan speed are stored in the memory. If a power failure occurs or the main power is turned off during operation, Auto restart function sets automatically to start operating in the same mode as the one set with the remote controller just before the shutoff of the main power. (Refer to page 6 for details.)
Indoor unit
Insert the power supply plug into the power outlet and/or turn the breaker on.
WARNING: Remove dirt from the power supply plug and insert the plug securely. If dirt adheres to the plug or insertion is incomplete, it may cause a fire or an electric shock.
Check the type of air conditioner.
Type Model Name
COOL & HEAT MSH-A18/24/30WV
COOL ONLY MS-A18/24/30WV
NOTE: This operating instructions manual has different contents for the COOL & HEAT type air conditioner and COOL ONLY type. Follow the appropriate instructions for each type of air conditioner.
Remote controller
The remote controller used for the COOL ONLY type air conditioner is different from the one used for the COOL & HEAT type as shown in the illustrations to the left.
Check the difference of operation mode.
Type Operation Mode
COOL & HEAT
(I FEEL...), (COOL), (DRY), (HEAT)
COOL ONLY
(I FEEL...), (COLL), (DRY), (FAN)
NOTE: Only the remote controller for the COOL & HEAT type air conditioner is illustrated as an example in this operating instructions manual.
Fan speed control button
CLOCK set button
Off-timer button
On-timer button
HR.button MIN.button (Time set buttons)
LONG button
In case of COOL ONLY type (MS series)
In case of COOL ONLY type (MS series)
5
Remote control­ler holder
COOL & HEAT type (MSH series)
1 Press the EMERGENCY OPERATION switch.
Each time the EMERGENCY OPERATION switch is pressed, the unit will operate in order of EMER­GENCY COOL MODE, EMERGENCY HEAT MODE and STOP MODE. However, when the EMERGENCY OPERATION switch is once pressed, the unit will operate in test run for 30 minutes and then the operation mode shifts to EMERGENCY MODE.
Details of EMERGENCY MODE are as shown be­low. However, the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation. The fan speed is set to High in test run and shifts to Medium after 30 min­utes.
Operation mode COOL HEAT
Set temperature 24°C24°C
Fan speed Medium Medium
Horizontal vane Auto Auto
Vertical vane Front Front
The operation mode is indicated by the Operation Indicator lamp on the indoor unit as following fig­ure.
Operation Indicator lamp
To stop the emergency operation, press the EMERGENCY OPERATION switch once (in case of EMERGENCY HEAT MODE) or twice (in case of EMERGENCY COOL MODE).
When the remote controller cannot be used (emergency operation)
When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the EMERGENCY OPERATION switch.
COOL ONLY type (MS series)
1 Press the EMERGENCY OPERATION switch.
When the EMERGENCY OPERATION switch is pressed, the unit will operate in test run for 30 min­utes at first and then the operation mode shifts to EMERGENCY COOL MODE.
Details of EMERGENCY COOL MODE are as shown below. However, the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation. The fan speed is set to High in test run and shifts to Medium after 30 minutes.
Operation mode COOL
Set temperature 24°C
Fan speed Medium
Horizontal vane Auto
Vertical vane Front
The operation mode is indicated by the Operation Indicator lamp on the indoor unit as following fig­ure.
Operation Indicator lamp
To stop the EMERGENCY COOL MODE, press the EMERGENCY OPERATION switch again.
Each time the switch is pressed, the operation mode alternates between the EMERGENCY COOL MODE and STOP MODE.
EMERGENCY HEAT
EMERGENCY COOL
STOP
EMERGENCY COOL STOP
Handling of the remote controller
The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in­door unit.
When a button is pressed, one or two beeps will be heard from the indoor unit. If no sound is heard, op­erate again.
Use the remote controller carefully. If it is dropped, thrown or it gets wet, the remote con­troller may not operate.
When installing on a wall, etc.
Install the remote controller holder in a position where the signal reception sound (beep) can be heard from the indoor unit when the
ON/OFF
button is pressed.
How to install/remove the remote controller
Installing :Insert the remote controller downward. Removing :Pull it up.
Dry-cell batteries
Reference for replacing batteries Replace the batteries with new AAA alkaline batteries in the following cases:
· When the indoor unit does not respond to the remote
control signal.
· When the display on the remote controller becomes
dim.
· When a button of the remote controller is pressed, all
displays appear on the screen, and then disappear immediately.
Do not use manganese batteries. The remote controller could malfunction.
The service life of an alkaline battery is about 1 year. However, a battery whose time limit is approaching may be exhausted soon. The recommended usable time limit is indicated (month/year) on the bottom of the battery.
To prevent liquid leakage, take out all batteries when the remote controller is not going to be used for a long time.
CAUTION: If liquid from the batteries gets onto your skin or clothes, wash it well with clean water. If liquid from the batteries gets into your eyes, wash them well with clean water and consult a doctor at once.
Do not use rechargeable batteries.
Replace the 2 batteries with new ones of the same
type.
Dispose of exhausted batteries in the correct man­ner.
Operation Indicator
Operation IndicatorOperation Indicator
Operation Indicator
Operation Indicator
Loading...
+ 10 hidden pages