13. PARTS LIST······················································43
14. OPTIONAL PARTS ······················BACK COVER
E1E1
E1E1
E1E1
1
Lubricant
Refrigerant
New refrigerant
R407C
R32: R125: R134a (23%:25%:52%)
Non-azeotropic refrigerant
Not included
A1/A1
86.2
-43.6
0.9177
42.5
Non combustible
0
1530
From liquid phase in cylinder
Impossible
Incompatible oil
Non
Non
Previous refrigerant
R22
HCFC22 (100%)
Single refrigerant
Included
A1
86.5
-40.8
0.94
44.4
Non combustible
0.055
1700
Gas phase
Possible
Compatible oil
Light yellow
Non
Refrigerant
Composition (Ratio)
Refrigerant handling
Chlorine
Safety group (ASHRAE)
Molecular weight
Boiling point (:)
Steam pressure [25:](Mpa [Gauge])
Saturated steam density [25:](Kg/K)
Combustibility
ODP w1
GWP w2
Refrigerant charge method
Additional charge on leakage
Kind
Color
Smell
w1:Ozone Destruction Parameter : based on CFC11
w2 :Global Warmth Parameter : based on CO
2
New SpecificationPrevious Specification
The incompatible lubricant easily separates from refrigerant
and makes the layer in the upper inside the suction muffler.
The higher position of the returning oil hole enables to return
the lubricant of the upper layer to the compressor.
Since refrigerant and lubricant are compatible each other,
lubricant returns to the compressor through the lower
position returning oil hole.
Compressor
Suction muffler
Returning oil hole
Lubricant
Refrigerant
Compressor
Suction muffler
Returning oil hole
Lubricant and Refrigerant
Compressor
-30 -20 -10 010 20
30
40 50 60
-0.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
(MPa[Gauge])
R407C
R22
Conversion chart of refrigerant temperature and pressure
Saturated liquid pressure
(:)
TECHNICAL CHANGES
INFORMATION FOR THE AIR CONDITIONER WITH R407C REFRIGERANT
This room air conditioner adopts HFC refrigerant (R407C) which never destroy the ozone layer.
Pay attention to following points.
1 Take sufficient care not to allow water and other contaminations to enter the R407C refrigerant during storage and
installation, since it is more susceptible to contaminations than HCFC (R22) refrigerant.
2 Clean refrigerant piping should be used.
3 Composition change may occur in R407C since it is a mixed refrigerant. When charging, charge liquid refrigerant to
prevent composition change.
4 Be especially careful when managing the tools.
If dust, dirt, or water mixes in the refrigerant cycle, it may cause decrease of performance.
NOTE : The unit of pressure has been changed to MPa on the
international system of units(SI unit system).
The conversion factor is: 1(MPa[Gauge]) =10.2(kgf/ff[Gauge])
2
1.Tools dedicated for the air conditioner with R407C refrigerant
R407C toolsCan R22 tools be used?
Gas leak detector
A gauge manifold with a sight glass is recommended for charging the
liquid refregerant.
Hose material have been changed to improve the pressure
resistance.
Dedicated for HFC refrigerant.
Description
Provided to prevent the back flow of oil. This adapter enables you to use
existing vacuum pumps.
No
No
No
Yes
Yes
New
New
Gauge manifold
Charge hose
Torque wrench
Flare tool
Vacuum pump
adapter
Electronic scale for
refrigerant charging
Use the electronic control scale for measuring the R407C.
The following tools are required for R407C refrigerant. Some R22 tools can be substituted for R407C tools.
Do not use tools that are used with R22 refrigerant in order to avoid mixing oils.
2.Refrigerant piping
Do not use copper pipes which are broken, deformed or discoloured.
In addition, be sure that the inner surfaces of the pipes are clean, free of hazardous sulfur and oxides, or have no dust/ dirt,
shaving particles, oil, moisture or any other contamination.
•If there is a large amount of residual oil inside the piping and joints, deterioration of the refrigerant oil will result.
3.Refrigerant oil
Apply the specific refrigeration oil (accessories) to the flare and the union seat surfaces.
4.Air purge
Use the vacuum pump for air purge to protect environments, and to avoid changing the composition of refrigerant.
5.Additional charge
For additional charging, charge the refrigerant with liquid phase slowly using a gas cylinder. If the refrigerant is charged with
gas phase, the composition of refrigerant will change. In this case, ability of the refrigerating cycle decreases or normal
operation can be impossible.
If liquid refrigerant is rapidly charged at once, the compressor may be locked.
NOTE: 1. The R407C is mixed refrigerant which consist of three different kinds of evaporative temperature. As a result, the
R407C occurs the change of composition.
2. Additional refrigerant charge has been changed by change of refrigerant.(R22 ➔ R407C)
Installation plate
Unit fixing screw
5 o 12mm
Wireless remote
controller
Remote controller
holder
Fixing screw for
3.5 o 16mm (Black)
Battery (AAA) for
remote controller
Drain hose
Drain pipe cover
Knockout cover
Screw for 4 o 10mm
Refrigerating oil
2
2
1
1
2
2
1
1
1
2
1
Q'ty
1
2
3
4
4
5
6
7
8
9
9
0
1
2
PART NAMES AND FUNCTIONS
MCF-C13UV -MCF-C18UV -MCF-C24UV -
INDOOR UNIT
E1E1E1
MUCF-C13UV -
E1
OUTDOOR UNIT
MUCF-C18UV -MUCF-C24UV -
Air inlet
(back and side)
Piping
Drain hose
Air outlet
Drain outlet
OUTDOOR UNIT
E1E1
Air inlet
Piping
Drain hose
Air outlet
Drain outlet
4
MCF-C13UV -MCF-C18UV -MCF-C24UV -
REMOTE CONTROLLER
Signal transmitting section
E1E1E1
Operation display section
OPERATE /STOP
(ON /OFF)button
Open the front lid.
Open the front lid.
ON/OFF
ON/OFF
TOO
WARM
CLOCK
TOO
WARM
PM
AM
TOO
COOL
PM
AM
TOO
COOL
TEMPERATURE buttons
FAN SPEED CONTROL button
OPERATION SELECT button
RESET button
I FEEL
FAN
MODE
COOL
DRY
FAN
VANE
RESET
5
CLOCK
STOP
START
HR.
MIN.
OFF-TIMER button
ON-TIMER button
HR. button
MIN. button
(TIME SET button)
CLOCK SET button
VANE CONTROL button
3
Indoor model
Function
Power supply
Capacity
Dehumidification
Air flow
(High/Med.W/LowW)
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
Sound level(High/Med.W/LowW)
Fan speed(High/Med.
W
/LowW)
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Outdoor model
Air flow
(High/LowW)
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level (High)
Fan speed
(High/LowW)
Fan speed regulator
Refrigerant filling
capacity(R407C)
Refrigerating oil (Model)