Mitel 3300 User Manual 2

Mitel PBX interface with Conferencing Server
Configuration Notes
Note: This document section is maintained by Mitel Networks
When referring to any information in this document please also check the Additions & Correction section on the last page for up dates.
7/4/2004 Page 1 of 22
Mitel PBX interface with Conferencing Server Configuration Notes
Mitel PBX interface with Conferencing Server Configuration Notes........................1
Introduction....................................................................................................................3
3300ICP with ISDN or SX2000 with ISDN...............................................................3
Example of T1 PRI programming on 3300 or SX2000...........................................3
Class Of Service – changes from default values................................ ................3
Link Descriptor Assignment....................................................................................4
Digital Link Assignment...........................................................................................4
MSDN- DPNSS-DASSII Trunk Circuit Descriptor................................................5
Trunk Service Assignment......................................................................................5
Digital Trunk Assignment................................ ........................................................5
3300 ICP with T1/D4 or SX2000 with T1/D4 ...........................................................5
Example of T1/D4 (CAS) Programming on 3300 or SX2000................................6
Class Of Service – changes from default values................................ ................6
Link Descriptor Assignment....................................................................................7
Digital Link Assignment...........................................................................................7
Digital E and M Trunk Circuit Descriptor Assignment................................ ........8
Trunk Service Assignment......................................................................................8
Digital Trunk Assignment................................ ........................................................9
Example of ARS Programming on 3300 ICP/SX2000...........................................9
Create Trunk Group .................................................................................................9
Add individual trunks to trunk group......................................................................9
Create Digit Modification Assignment.................................................................11
Create Route Assignment.....................................................................................11
Create ARS Digits Dialed Assignment................................................................11
SX200 with ISDN........................................................................................................12
SX200 with T1/D4................................ ......................................................................20
T1 Crossover cable wiring Specifications [RJ45 Connector]..............................21
7/4/2004 Page 2 of 22
Introduction
This document describes the configuration of Mitel Networks PBX’s to correctly interface to the Interactive Group Communication System by VCon. For more information on the configuration of the IGC, please refer to Mitel 3300 - RemoteAbility IGC Integration Specifications V1. Note that all PBX configuration should be undertaken by a qualified Technician.
3300ICP with ISDN or SX2000 with ISDN
Attach VCon IGC server T1 link to NSU, DSU or Embedded PRI card
o Configure hardware for Line Termination through jumpers or DIP
switch – please refer to the Technician’s Handbook of the correct product (3300 or SX2000)
connect to server with a straight through cable
Program trunks
o for example, please see Example of T1 PRI programming on 3300
Program PRI link characteristics though IMAT (for NSU or DSU) or through ESM ( embedded PRI card in 3300ICP)
o Protocol used is DMS-250, user side
Reset NSU or PRI card to allow new configuration to load
Test link to server by dialing <feature access code for individual trunk
access> <trunk number><any 4 digit number>< # > e.g. <**2><6101><1000><#>
o You should hear “Welcome to Remoteability”
Program ARS so that a single four digit number accesses the IGC system
o Program trunk group o Add trunks to trunk group o Create Digit Modification Assignment o Create Route Assignment o Create ARS Digits Dialed Assignment o Please see Example of ARS Programming on 3300 or SX2000
Example of T1 PRI programming on 3300 or SX2000
Class Of Service – changes from default values
Public Network Access via DPNSS Yes
7/4/2004 Page 3 of 22
ANI/DNIS/ISDN Number Delivery Yes
ISDN NODE
Service Limit (millisec.):
Controller
Shelf
Link Descriptor Assignment
Number: 4 Address for Message Control: A
BER - Maintenance Limit, 10**-n: 4 BER - Service Limit, 10**-n: 3 Data Call Alternate Digit Inversion: Yes Framing Losses in 24 hrs - Maintenance Limit: 255 Framing Losses in 24 hrs - Service Limit: 9000 Integrated Digital Access: Satellite Link Delay: No Slip Rate - Maintenance Limit (slips/24hr.): 5000 Slip Rate - Service Limit (slips/24hr.): 7000 Alarm Debounce Timer ­Voice Encoding: Invert Data Encoding: Nil QSIG Private Network Access: No Digital Link Fault Delay Timer (sec.): 240 Termination Mode: LT T1 Only: B8ZS Zero Code Suppression: Yes Operation Mode: DSX-1 CSU Tx Line Build-Out (dB.): DSX-1 Line Length (Ft.): 0-133 Extended Super Frame: Yes Inverted D channel ( DPNSS only ): No E1 Only: CRC-4 Enabled: Yes E1 Line Length (Ft.): 0-133 E1 Impedance (Ohms): 120
500
Digital Link Assignment
Module 1 1 6 1 1 1 UNIVERSAL T1
1 1 6 1 1 2 UNIVERSAL T1
Port Unit
7/4/2004 Page 4 of 22
Slot Link Interface Type
MSDN-DPNSS-DASSII Trunk Circuit Descriptor
Local Office
Absorb:
Dual
Number Card Type 4 UNIVERSAL T1 Incoming
Seizure Priority
Far End Connection
MSDN- DPNSS
Trunk Service Assignment
Trunk Service Number: 4 Release Link Trunk: No
Class of Service: 4 Class of Restriction: 1
Baud Rate: 300 Intercept Number: 1
Non-dial In Trunks Answer Point - Day: Non-dial In Trunks Answer Point - Night 1: Non-dial In Trunks Answer Point - Night 2: Dial In Trunks Incoming Digit Modification ­Dial In Trunks Incoming Digit Modification - Insert:
Trunk Label: ISDN Trunk
0
Signalling Protocol
Digital Trunk Assignment
Cabinet: 6 Shelf: 1 Slot: 1 Circuit: 1 Card Type: UNIVERSAL T1 Trunk Number: 6101 Trunk Service Number: 4 DTS Service Number: Circuit Descriptor Number: 4 Interconnect Number: 1
3300 ICP with T1/D4 or SX2000 with T1/D4
7/4/2004 Page 5 of 22
Attach VCon IGC server T1 link to NSU, DSU or Embedded PRI card
o Configure hardware for Line Termination through jumpers or DIP
switch – please refer to the Technician’s Handbook of the correct product (3300 or SX2000)
connect to server with a straight through cable
Program trunks
o for example, please see Example of T1/D4 Programming on 3300
or SX2000
Test link to server by dialing <feature access code for individual trunk access> <trunk number><any 4 digit number>< # > e.g. <**2><6101><1000><#>
o You should hear “Welcome to Remoteability”
Program ARS so a single four digit number accesses the IGC system
o Program trunk group o Add trunks to trunk group o Create Digit Modification Assignment ** see following note
o Create Route Assignment o Create ARS Digits Dialed Assignment
o Please see Example of ARS Programming on 3300 or SX2000
**Note: The Dialogic card in the IGC server is expecting ANI on the T1D4 trunk, but the 3300 or SX2000 does not deliver ANI over T1D4. This will result in a 10 to 15 second delay in accessing the IGC after the trunk access number is dialed. To correct this, send an ANI digit string to the trunk through the Digit M odification Form. See below.
Digit Modification Assignment
Digit Modification Number
Number of Digits to Absorb
Digits to be Inserted
Final Tone Plan/Information Marker
1 3 2 0 3 1 <T01> 4 0 **6135922122**
Example of T1/D4 (CAS) Programming on 3300 or SX2000
Class Of Service – changes from default values
Public Network Access via DPNSS Yes
7/4/2004 Page 6 of 22
ANI/DNIS/ISDN Number Delivery Yes
Service Limit (millisec.):
Controller
Shelf
Descriptor
Link Descriptor Assignment
Number: 4 Address for Message Control: BER - Maintenance Limit, 10**-n: 4 BER - Service Limit, 10**-n: 3 Data Call Alternate Digit Inversion: Yes
Framing Losses in 24 hrs - Maintenance Limit: 255 Framing Losses in 24 hrs - Service Limit: 9000 Integrated Digital Access: T1D4 Satellite Link Delay: No Slip Rate - Maintenance Limit (slips/24hr.): 5000
Slip Rate - Service Limit (slips/24hr.): 7000 Alarm Debounce Timer -
Voice Encoding: Invert Data Encoding: Nil QSIG Private Network Access: No
Digital Link Fault Delay Timer (sec.): 240 Termination Mode: NT T1 Only: B8ZS Zero Code Suppression: Yes Operation Mode: DSX-1 CSU Tx Line Build-Out (dB.): DSX-1 Line Length (Ft.): 0-133 Extended Super Frame: No Inverted D channel ( DPNSS only ): No E1 Only: CRC-4 En abled: No E1 Line Length (Ft.): 0-133 E1 Impedance (Ohms): 120
500
Digital Link Assignment
Module 1 1 6 1 1 1 UNIVERSAL T1 4 Remoteability
1 1 6 1 1 2 UNIVERSAL T1 4 T1D4
Digital
Port Unit
Slot
Link Interface Type
Link
7/4/2004 Page 7 of 22
Comment
Loading...