Miele PG 8061 Installation diagram

Installation Plan / Plan d’installation
Commercial Dishwasher / Lave-vaisselle professionnel
PG 8061
Mat. no.: 10 076 790 / 02
en / fr- CA
page
1 / 10
Installation plan /
Plan d`installation
PG 8061
Installation instruction
Water connection
Observe installation instructions when installing machine.
Installation
Condensate
Freestanding installation
Electrical connection
Non-return device
External dosing system (optional)
This dishwasher is only suitable for commercial use.
Installation shall only be carried out by Miele Service or authorized installers in accordance with valid regulations, relevant standards and health and safety codes!
Only use commercial grade cabinetry in the vicinity of this commercial dishwasher as condensate may otherwise cause damage.
For free-standing installation of a built-in machine (U version) the freestanding retrofit kit STAND2 is required. To ensure stability install the included floor bracket BBF-80 (Installation Instructions Mat.no.: 9788890)
The unit is supplied with electrical cord and plug. The receptacle must be accessible after machine installation.
With a hard-wired installation, the main switch must be provided on site and must totally isolate the machine from the mains with a contact gap of at least 3 mm.
If necessary, an equipotential bond with good contact connection must be provided in accordance with all appropriate national and local regulations.
Protection class IP21
The machine requires 2 cold water connections for machine and built­in steam condenser. To connect both hoses to 1 cold water supply line, a Y-piece connector is supplied with the unit.
To speed up cycle times the unit has a hot water connection. If a hot water connection is not available on site, the hot water supply can be deactivated in the machine control by Miele Service.
Connection to a drinking water supply is permissible without an additional non-return device.
Connect up to 2 dosing systems at the rear panel for liquid cleaning agent and rinse aid.
Installation plan /
Plan d`installation
PG 8061
page
2 / 10
Electrical connection (208 V) – (EL)
Voltage (default)
Rated load 5.8 kW 5.8 kW
Fuse rating 2 × 30 A 3 × 20 A
Minimum cross-section 3 × AWG10 4 × AWG12
Length of electrical cord (UL 921) with plug approx. 6‘ 2“ approx. 6‘ 2“
Plug NEMA L6-30 NEMA L15-20
Voltage (convertible)
Rated load 5.8 kW 5.8 kW
Fuse rating 3 × 20 A 2 × 30 A
Minimum cross-section 4 × AWG12 3 × AWG10
Length of electrical cord (UL 921) with plug approx. 6‘ 2“ approx. 6‘ 2“
Plug NEMA L15-20 NEMA L6-30
Electrical connection (240 V) – (EL)
PG8061U (Built-in)
2 AC 208V 60Hz 3 AC 208V 60Hz
3 AC 208V 60Hz 2 AC 208V 60Hz
PG8061 (Freestanding)
Voltage (default)
Rated load 5.8 kW
Fuse rating 2 x 30 A
Minimum cross-section 3 x AWG10
Length of electrical cord (UL 921) with plug approx. 6‘ 2“
Plug NEMA L6-30
Voltage (convertible)
Rated load 5.8 kW
Fuse rating 3 × 20 A
Minimum cross-section 4 × AWG12
Length of electrical cord (UL 921) with plug approx. 6‘ 2“
Plug NEMA L15-20
2 AC 240V 60Hz
3 AC 240V 60Hz
Cold water – (KW+DK)
Max. Temperature 68 °F 20 °C
Max. Water hardness 70 gr/gal 70 °d
Min. Flow pressure 29 psi 200 kPa
Min. Flow pressure with extended water intake 5.8 psi 40 kPa
Max. pressure 145 psi 1,000 kPa
Throughput 2 gal/min 7.5 l/min
Water supply hoses (supplied) 2 hoses incl. Y-piece 2 hoses incl. Y-piece
Connection thread - on site (flat sealing)
Hose connection – positioning
Length of connection hose (supplied) approx. 5‘ 7“ approx. 1.7 m
Length of the steam condenser hose approx. 5‘ 7“ approx. 1.7 m
3/4“ male, garden hose thread
Hose connection facing downwards or parallel to the ground. Total height of waterproof module including water filter: 11” / 28cm , Refer to Fig. 2 for further illustration
3/4“male, garden hose thread
page
3 / 10
Installation plan /
Plan d`installation
PG 8061
Hot water - (WW)
Max. Temperature 150 °F 65 °C
Max. Water hardness 70 gr/gal 70 °dH
Min. Flow pressure 29 psi 200 kPa
Min. Flow pressure with extended water intake 5.8 psi 40 kPa
Max. pressure 145 psi 1,000 kPa
Throughput 2 gal/min 7,5 l/min
Connection thread - on site (flat sealing)
Hose connection - positioning
Length of connection hose (supplied) approx. 5‘ 7“ approx. 1.7 m
3/4“ male, garden hose thread
Hose connection facing downwards or parallel to the ground. Total height of waterproof module including water filter: 11” / 28cm , Refer to Fig. 2 for further illustration
3/4“ male, garden hose thread
Drain water - (AW)
Drain connection via barbed connection 3/4“ 3/4“
Drain hose (internal diameter x wall thickness) 7/8” x ¼” 22 x 6 mm
Length of Commercial Dishwasher drainage hose 4’ 11” approx. 1.5 m
Drain pump head height from floor level, max. 3’ 3” 1 m
Drainage hose delivery, max. 4.2 gal/min 16 l/min
On-site hose connector (external diameter x length) 7/8” x 1 3/16” 22 x 30 mm
Max. effluent temperature 185°F 85°C
External dosing system DOS G80 (optional) – (DS)
Connect up to 2 dosing systems at the rear panel for liquid cleaning agent and rinse aid.
Dimensions (WxHxD) 4 1/2"x4 ¾ “x4 ¾ “ 115x120x120 mm
Total chemical supply line length (from suction lance to machine) 5’ 7” + 9’ 11” 1.7 m + 3.0 m
Size for 10L detergent container (WxHxD) 7 ½“ x 13“ x 10“ 190x320x250 mm For further details refer to „Fitting instructions DOS module“
Heat dissipation to room
Heat transfer by emission 1.200 BTU 0.35 kWh
Load on removal 1.370 BTU 0.40 kWh