Instruction 042677 Rev D – BE032004
August 19, 2002 - MA6900
MA6900 FINAL ASSEMBLY
INSTRUCTIONS FOR COUNTRY GROUPS 01-08 AND 10
The MA6900 is designed for use in Country Groups 01-08 and 10. All conversions are performed by
moving two identical thermistors located on the Power Transformer Terminal Block to new locations
as illustrated.
COUNTRY GROUP 01 - USA AND OTHERS
Parts Required:
1 – MA6900
1 – 089104 Fuse (T 6.3AL 250V SB)
1 – 170937 Line Cord Set
1 – 125412 CSA Certification Label
Step 1:Wire Power Transformer Terminal Block as illustrated in Figure 1.
Step 2: Insert Fuse P/N 089104 into Rear Panel and apply label 125412.
T
Fig. 1 Wired for 120VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 2
Page 2 of 9
COUNTRY GROUP 02 - JAPAN
Parts Required:
1 – MA6900
1 – 126873 Input Rating Decal (100V~ 50/60Hz 5.2A)
1 – 125781 Line Cord Tag (100V)
1 – 170937 Line Cord Set
1 – 089104 Fuse (T 6.3AL 250V SB)
Step 1: Wire Power Transformer Terminal Block as illustrated in Figure 2.
Step 2: Change the screened Rear Panel Input Rating to 100V~ 50/60Hz 5.2A with P/N 126873.
Step 3: Tag Line Cord P/N 170937 with P/N 125781 (100V) and ship with Unit.
Step 4: Insert Fuse P/N 089104 into Rear Panel.
T
Fig. 2 Wired For 100VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 3
Page 3 of 9
COUNTRY GROUP 03 - TAIWAN
Parts Required:
1 – MA6900
1 – 125731 Date of Manufacture Decal
1 – 126876 Input Rating Decal (110V~ 60Hz 4.8A)
1 – 126095 Line Cord Tag (110V)
1 – 089104 Fuse (T 6.3AL 250V SB)
1 – 170937 Line Cord Set
Step 1: Wire Power Transformer Terminal Block as illustrated in Figure 3.
Step 2: Insert Fuse P/N 089104 into Rear Panel and apply Decals.
Step 3: Changed screened Rear Panel Input Rating to 110V~ 60Hz 4.8A using P/N 126876.
Step 4: Tag Line Cord P/N 170937 with P/N 126095 (110V) and ship with Unit.
T
Fig. 3 Wired for 120VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 4
Page 4 of 9
COUNTRY GROUP 04 - ENGLAND
Parts Required:
1 – MA6900
1 – 126877 Input Rating Decal (230V~50/60Hz 2.35A)
1 – 125783 Line Cord Tag (230V)
1 – 170378 Line Cord Set For England
1 – 089098 Fuse (T 3.15AL 250V SB) IEC
4 – 017727 Plug (Black)
4 – 017726 Plug (Red)
1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB)
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 4.
Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679.
Step 3: Change screened Rear Panel Input Rating to 230V~50/60Hz 2.35A using P/N 126877.
Step 4: Tag Line Cord P/N 170378 with P/N 125783 (230V) and ship with Unit.
Step 5: Place Red Plugs P/N 017726 and Black Plugs P/N 017727 into appropriate output terminal
connector.
T
Fig. 4 Wired for 240VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 5.
Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679.
Step 3: Change screened Rear Panel Input Rating to 230V~50/60Hz 2.35A using P/N 126877.
Step 4: Tag Line Cord P/N 170200 with P/N 125783 (230V) and ship with Unit.
Step 5: Place Red Plugs P/N 017726 and Black Plugs P/N 017727 into appropriate output terminal
connector.
T
Fig. 5 Wired for 240VAC Conversion
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 6
Page 6 of 9
COUNTRY GROUP 06 - AUSTRALIA
Parts Required:
1 – MA6900
1 – 170989 Line Cord Set for Australia
1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB)
1 – 089098 Fuse (T 3.15AL 250V SB)
1 – 126878 Input Rating Decal (240V~50/60Hz 2.25A)
1 – 125784 Line Cord Tag (240V)
1 – 126897 Australian Cert Label
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 6.
Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679.
Step 3: Change screened Rear Panel Input Rating to 240V~50/60Hz 2.25A using P/N 126878 and
apply “Australian Cert Label” 126897 to products rear panel.
Step 4: Tag Line Cord P/N 170989 with P/N 125784 (240V) and ship with Unit.
T
Fig. 6 Wired for 240VAC Conversion
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 7
Page 7 of 9
COUNTRY GROUP 07 - SAUDI ARABIA
Parts Required:
1 – MA6900
1 – 170200 Line Cord Set for Europe
1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB)
1 – 089098 Fuse (T 3.15AL 250V SB)
1 – 126879 Input Rating Decal (220V~50/60Hz 2.45A)
1 – 125398 Line Cord Tag (220V)
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 7.
Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679.
Step 3: Change screened Rear Panel Input Rating to 220V~50/60Hz 2.45A using P/N 126879.
Step 4: Tag Line Cord P/N 170200 with P/N 125398 (220V) and ship with Unit.
T
Fig. 7 Wired for 220VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 8
Page 8 of 9
COUNTRY GROUP 08 - KOREA
Parts Required:
1 – MA6900
1 – 126791 Tom Chung’s Korean Regulatory Decal
1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB)
1 – 089098 Fuse (T 3.15AL 250V SB)
1 – 126879 Input Rating Decal (220V~50/60Hz 2.45A)
1 – 125398 Line Cord Tag (220V)
1 – 171477 Korean Certified Line Cord Set
1 –126860 KTL Required Address Label
1 – 126889 KTL Certification Label
1 – 125731 Date of Manufacture Label
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 8.
Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679.
Step 3: Change the screened Rear Panel Input Rating to 220V~50/60Hz 2.45A using P/N 126879.
Step 4: Tag Line Cord P/N 171477 with P/N 125398 (220V) and ship with Unit.
Step 5: Apply Tom Chung’s Korean Regulatory Decal P/N 126791 to Unit.
Step 6: Apply labels 126860,125731 and 126889 to product.
T
Fig. 8 Wired for 220VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 9
Page 9 of 9
COUNTRY GROUP 10 - HONG KONG
Parts Required:
1 – MA6900
1 – 171159 Line Cord Set
1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB)
1 – 089098 Fuse (T 3.15AL 250V SB)
1 – 126880 Input Rating Decal (220V~50Hz 2.45A)
1 – 125398 Line Cord Tag (220V)
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 9.
Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679.
Step 3: Change the screened Rear Panel Input Rating to 220V~50Hz 2.45A using P/N 126880.
Step 4: Tag Line Cord P/N 171159 with P/N 125398 (220V) and ship with Unit.
T
Fig. 9 Wired for 220VAC Operation
NOTES:
04/05/02PE Share updatedInputs from Lee Savidge.
06/17/02CN# 16639Adds CSA Certification Label to Group 1.
06/26/02CN# 16606Country Group 8 is KTL Certified-Change Adds/Deletes
components in order to meet KTL requirements.
08/19/02CN# 16672Adds “ Australian Cert Label “ 126897 to Group 6 product.
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903