McIntosh MA 6900 Voltage Conversion

Page 1
Page 1 of 9
Instruction 042677 Rev D – BE032004 August 19, 2002 - MA6900
MA6900 FINAL ASSEMBLY
INSTRUCTIONS FOR COUNTRY GROUPS 01-08 AND 10
The MA6900 is designed for use in Country Groups 01-08 and 10. All conversions are performed by moving two identical thermistors located on the Power Transformer Terminal Block to new locations as illustrated.
COUNTRY GROUP 01 - USA AND OTHERS
Parts Required: 1 – MA6900 1 – 089104 Fuse (T 6.3AL 250V SB) 1 – 170937 Line Cord Set 1 – 125412 CSA Certification Label
Step 1:Wire Power Transformer Terminal Block as illustrated in Figure 1. Step 2: Insert Fuse P/N 089104 into Rear Panel and apply label 125412.
T
Fig. 1 Wired for 120VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 2
Page 2 of 9
COUNTRY GROUP 02 - JAPAN
Parts Required: 1 – MA6900 1 – 126873 Input Rating Decal (100V~ 50/60Hz 5.2A) 1 – 125781 Line Cord Tag (100V) 1 – 170937 Line Cord Set 1 – 089104 Fuse (T 6.3AL 250V SB)
Step 1: Wire Power Transformer Terminal Block as illustrated in Figure 2. Step 2: Change the screened Rear Panel Input Rating to 100V~ 50/60Hz 5.2A with P/N 126873. Step 3: Tag Line Cord P/N 170937 with P/N 125781 (100V) and ship with Unit. Step 4: Insert Fuse P/N 089104 into Rear Panel.
T
Fig. 2 Wired For 100VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 3
Page 3 of 9
COUNTRY GROUP 03 - TAIWAN
Parts Required: 1 – MA6900 1 – 125731 Date of Manufacture Decal 1 – 126876 Input Rating Decal (110V~ 60Hz 4.8A) 1 – 126095 Line Cord Tag (110V) 1 – 089104 Fuse (T 6.3AL 250V SB) 1 – 170937 Line Cord Set
Step 1: Wire Power Transformer Terminal Block as illustrated in Figure 3. Step 2: Insert Fuse P/N 089104 into Rear Panel and apply Decals. Step 3: Changed screened Rear Panel Input Rating to 110V~ 60Hz 4.8A using P/N 126876. Step 4: Tag Line Cord P/N 170937 with P/N 126095 (110V) and ship with Unit.
T
Fig. 3 Wired for 120VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 4
Page 4 of 9
COUNTRY GROUP 04 - ENGLAND
Parts Required: 1 – MA6900 1 – 126877 Input Rating Decal (230V~50/60Hz 2.35A) 1 – 125783 Line Cord Tag (230V) 1 – 170378 Line Cord Set For England 1 – 089098 Fuse (T 3.15AL 250V SB) IEC 4 – 017727 Plug (Black) 4 – 017726 Plug (Red) 1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB)
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 4. Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679. Step 3: Change screened Rear Panel Input Rating to 230V~50/60Hz 2.35A using P/N 126877. Step 4: Tag Line Cord P/N 170378 with P/N 125783 (230V) and ship with Unit. Step 5: Place Red Plugs P/N 017726 and Black Plugs P/N 017727 into appropriate output terminal
connector.
T
Fig. 4 Wired for 240VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 5
Page 5 of 9
COUNTRY GROUP 05 - EUROPE
Parts Required: 1 – MA6900 1 – 126877 Input Rating Decal (230V~ 50/60Hz 2.35A) 1 – 125783 Line Cord Tag (230V) 1 – 170200 Line Cord Set 1 – 089098 Fuse (T 3.15AL 250V SB) IEC 1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB) 4 – 017726 Plug (Red) 4 – 017727 Plug (Black)
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 5. Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679. Step 3: Change screened Rear Panel Input Rating to 230V~50/60Hz 2.35A using P/N 126877. Step 4: Tag Line Cord P/N 170200 with P/N 125783 (230V) and ship with Unit. Step 5: Place Red Plugs P/N 017726 and Black Plugs P/N 017727 into appropriate output terminal
connector.
T
Fig. 5 Wired for 240VAC Conversion
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 6
Page 6 of 9
COUNTRY GROUP 06 - AUSTRALIA
Parts Required: 1 – MA6900 1 – 170989 Line Cord Set for Australia 1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB) 1 – 089098 Fuse (T 3.15AL 250V SB) 1 – 126878 Input Rating Decal (240V~50/60Hz 2.25A) 1 – 125784 Line Cord Tag (240V) 1 – 126897 Australian Cert Label
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 6. Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679. Step 3: Change screened Rear Panel Input Rating to 240V~50/60Hz 2.25A using P/N 126878 and
apply “Australian Cert Label” 126897 to products rear panel.
Step 4: Tag Line Cord P/N 170989 with P/N 125784 (240V) and ship with Unit.
T
Fig. 6 Wired for 240VAC Conversion
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 7
Page 7 of 9
COUNTRY GROUP 07 - SAUDI ARABIA
Parts Required: 1 – MA6900 1 – 170200 Line Cord Set for Europe 1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB) 1 – 089098 Fuse (T 3.15AL 250V SB) 1 – 126879 Input Rating Decal (220V~50/60Hz 2.45A) 1 – 125398 Line Cord Tag (220V)
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 7. Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679. Step 3: Change screened Rear Panel Input Rating to 220V~50/60Hz 2.45A using P/N 126879. Step 4: Tag Line Cord P/N 170200 with P/N 125398 (220V) and ship with Unit.
T
Fig. 7 Wired for 220VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 8
Page 8 of 9
COUNTRY GROUP 08 - KOREA
Parts Required: 1 – MA6900 1 – 126791 Tom Chung’s Korean Regulatory Decal 1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB) 1 – 089098 Fuse (T 3.15AL 250V SB) 1 – 126879 Input Rating Decal (220V~50/60Hz 2.45A) 1 – 125398 Line Cord Tag (220V) 1 – 171477 Korean Certified Line Cord Set 1 –126860 KTL Required Address Label 1 – 126889 KTL Certification Label 1 – 125731 Date of Manufacture Label
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 8. Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679. Step 3: Change the screened Rear Panel Input Rating to 220V~50/60Hz 2.45A using P/N 126879. Step 4: Tag Line Cord P/N 171477 with P/N 125398 (220V) and ship with Unit. Step 5: Apply Tom Chung’s Korean Regulatory Decal P/N 126791 to Unit. Step 6: Apply labels 126860,125731 and 126889 to product.
T
Fig. 8 Wired for 220VAC Operation
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Page 9
Page 9 of 9
COUNTRY GROUP 10 - HONG KONG
Parts Required: 1 – MA6900 1 – 171159 Line Cord Set 1 – 126679 Fuse Replacement Decal (T 3.15AL 250V SB) 1 – 089098 Fuse (T 3.15AL 250V SB) 1 – 126880 Input Rating Decal (220V~50Hz 2.45A) 1 – 125398 Line Cord Tag (220V)
Step 1: Wire Power Transformer Terminal block as illustrated in Figure 9. Step 2: Insert Fuse P/N 089098 into Rear Panel and affix Fuse Replacement Decal P/N 126679. Step 3: Change the screened Rear Panel Input Rating to 220V~50Hz 2.45A using P/N 126880. Step 4: Tag Line Cord P/N 171159 with P/N 125398 (220V) and ship with Unit.
T
Fig. 9 Wired for 220VAC Operation
NOTES:
04/05/02PE Share updatedInputs from Lee Savidge. 06/17/02CN# 16639Adds CSA Certification Label to Group 1. 06/26/02CN# 16606Country Group 8 is KTL Certified-Change Adds/Deletes
components in order to meet KTL requirements.
08/19/02CN# 16672Adds “ Australian Cert Label “ 126897 to Group 6 product.
T
McIntosh Laboratory, Inc., 2 Chambers St., Binghamton, NY 13903
Loading...