Marantz DV-110 Sevice Bulletin

0 (0)
Date: 17-Mar.-2004 Model: DV110/N1S
Page: 1 / 2 REF.NBR: MZ04-031
SERVICE BULLETIN
Circulation: Application:
Subject:
By crack of Laser Pickup slide shaft, Pickup stops moving and cannot playback the Disc.
x for information customer
complaint in case of service mandatory
...................
See below
Int.ref:
The part defect of the Laser Pickup slide shaft. (It occurs only in specific serial number because defective plastic part mixing.)
[SOLUTION]
1) Replace the Laser Pickup slide shaft of Loader Assy.
This work is the same as DV4300 (SERVICE BULLETIN REF.NBR: MZ04-016)
As for the details, Please see page 2/2.
.
Difference of a shaft, the bottom form of slot is different.
Flat
Defect shaft New shaft
Circle
Bottom of slot
21AW112010
[NECESSARY PART]
1) Part no.
2) Part no.
21AW112010 *G75400000
(NEW Laser Pickup slide shaft)
(FLOIL G754 KANTO KASEI LTD.)
[REMARKS]
With the Unit which has returned from the customer by repair, the following serial number replace the Laser Pickup slide shaft.
This problem apply to following serial number DV110/N1S MZ000308000382 to MZ000308000681 300sets MZ000314000682 to MZ000314001031 350sets MZ000320001032 to MZ000320001564 533sets MZ000323001565 to MZ000323002044 480sets MZ000332002045 to MZ000332002349 305sets T/T 1968sets
Approved by S.NAGAO Written by
WQ-19 2 817
/additional rule 3 (1st Issue 2003-03-19)
Loading...