Magellan RTX3 Reference And Installation Manual

Page 1
RTX3: Wireless Expansion Module V5.1
Reference and Installation Manual
Page 2
Page 3
Table of Contents
Specifications.............................................................. 4
Overview............................................................. 5
Description.................................................................. 5
Features...................................................................... 5
Installation........................................................... 7
System Reset ............................................................. 7
LED Feedback............................................................ 8
Programming...................................................... 8
Programming for Imperial ........................................... 8
Programming for Spectra SP Series........................... 9
Programming for EVO ................................................ 9
Programming for Esprit and Stand Alone................. 15
Stand Alone Use....... ... .......................... ... ... ... .... ... ... 18
Firmware Upgrade.................................................... 18
Index................................................................. 19
Page 4
Page 4
Specifications
Hardware Compatibility
Power input voltage: 12Vdc Frequency: 433MHz or 868MHz Sensitivity: -120 dBm Current consumption: 50 mA Dimensions
(no antenna):
15cm x 16cm x 3cm (6in x 6.5in x 1.1in)
Operating temperature: 0°C to 49°C (32°F to 120°F) PGM outputs: PGM1 and PGM2 - 150mA PGM transistor
outputs PGM3 - form C relay output rated at 5A/28Vdc,
N.O./N.C. (PGM4 optional) Range: Refer to the appropriate transmitter Instructions Other: Di-pole antenna; Error Correction Algorithm Approvals: For the latest information on product approvals,
visit our Web site at paradox.com
Imperial EVO Spectra SP Esprit Stand Alone
Zones 32 32 32 - 32 Remotes 999 32/96/999 32 32 32 Remote
Type
REM1
RAC1
REM2
RAC2
REM3
REM15
REM1
RAC1
REM2
RAC2
REM3
REM15
REM1
RAC1
REM2
RAC2
REM3
REM15
REM1
REM15
REM1
REM15
Wireless PGMs
-8 16- -
Wireless Keypads
-- 8- -
Wireless Siren
-- 4- -
Wireless Repeater
-- 2- -
PX8 Output Module
-- -- 4
Page 5
Overview Page 5
Chapter 1:
Overview
Description
The RTX3 is a 2-way, 32 zone wireless expansion module which enables Imperial, DGP/EVO, Spectra SP Series or Esprit control panels to support wireless hardware such as motion detectors and remote controls.
Features
Up to 32 wireless zones
Support for REM1 / REM2 / REM3 / REM15 / RAC1 / RAC2 remote controls
Support for wireless PGMs (EVO / SP Series only)
Support for all Magellan transmitters including 2WPGM
Support for two RPT1 and eight K32RF / K37 (SP Series only)
Support for SR150 Wireless Siren and RPT1 Wireless Repeater (SP Series only)
Support for PX8 Output Module
In-field firmware upgradeable through WinLoad via serial or 4-wire connection
RF jamming supervision
Low battery, tamper and check-in supervision
Transmitter signal strength display
3 PGM outputs and 1 optional output (not available on Imperial panels)
Noise level test and indicator
Included Items:
• 2 antennas
Required/Optional Items:
• Mounting hardware
• Optional 12Vdc external power supply (PS27D / PS17)
Compatibility:
• Imperial V32 panels
• EVO / DGP panels
• Spectra SP Series panels
• Esprit panels
Page 6
Page 6 Overview
1. LED display (see LED Feedback on page 8)
2. Firmware upgrade serial connection (see Firmware Upgrade on page 18)
3. Anti-tamper switch
4. PCB screw
5. Antennas
6. Mounting clips
7. Esprit Mode Programming button: Press to enter programming mode in Esprit mode (see Programming for Esprit and Stand Alone on page page 15). Also used for system reset (see System Reset on page 7).
8. Connect the Esprit 636/646 LED keypad to the “Program” connector to program in Esprit and St and Alone mode.
9. Wiring slot
2
8
7
1
5
4
3
9
6
Page 7
Installation Page 7
Chapter 2: Installation
1. Control panel Combus connection NOTE: If you are using the RTX3 as a stand-alone device, connect an external 12Vdc power supply to the RED and BLK terminals. Battery backup is recommended.
2. If the current draw exceeds 150mA on PGM1 or PGM2, use a relay. Connect the RTX3’s RED connector to the relay’s RED connector, and the PGM connector (PGM1 or PGM2) to the relay’s BLK connector.
3. Connect PGM3 and PGM4 to external power supplies if you need additional power. A PS-817 is recommended. Connect the PGM’s N/O connector to the external power supply’s “+” connection. Connect the power supply’s “-” connector to the device’s “-” connector. Connect the PGM’s COM connector to the device’s “+” connector. NOTE: Write down the serial number of all wireless modules to be used with the RTX3. If this installation replaces another RTX3, make sure the programming can be transferred.
System Reset
The system reset feature only functions during the first 30 seconds after RTX3 power up. In order to reset the system, press and hold the Programming button for 5 seconds, the BUS RX LED flashes. Release the button and press it again while the LED flashes to reset the module to its default values.
2
3
1
Page 8
Page 8 Programming
LED Feedback
Chapter 3: Programming
This chapter provides programming instructions for Imperia l, Spectra SP Series, EVO, Esprit, and stand alone installations.
Programming for Imperial
When connected to an Imperial panel, all RTX3 settings are programmed using BabyWare. For more detailed instructions on using BabyWare and programming remotes, refer to the Imperial System Guide.
All Panels
ERROR
Problem with the module
BUS RX
Receiving from panel
BUS TX
Transmitting to panel
RF RX
Receiving wireless
RF TX
Transmitting wireless
R
G
G
G
Y
EVO and SP Series only
ERROR BUS RX
BUS TX
Com fail: GRN/YEL short / no data
R
ERROR BUS RX BUS TX
Com fail: too many modules / wrong data
R
G
ERROR BUS RX
BUS TX
Com fail: GRN/ YEL reversed
G
R
G
ERROR BUS RX
BUS TX
Combus power too low
R
Legend R = Red
G = Green Y = Yellow
= Off
= On
= Flashing
Page 9
Programming Page 9
To program an RTX3 for an Imperial system:
1. When BabyWare is communicating with the V32 controller and an RTX3 module is connected to the Multibus, it automatically appears in the Modules display area. To view the Modules display area, click the Modules toggle button. Alternatively , you may wish to add a module to BabyW are before the module is physically connected to the system. Click the Add Item button and add the RTX3 from the Zone Expansion Modules list.
2. When the RTX3 is added to the system, double-click the module’s icon. The RTX3 Programming window opens.
3. From the RTX3 Programming window, configure Input Setup and Input options. Click OK.
Programming for Spectra SP Series
When connected to a Spectra SP series panel, the wireless settings are programmed using control panel programming sections. Refer to the panel’s Programming Guide.
NOTE: Programming for a Spectra SP series system requires K32 or K10V/H keypads version 2.0 or higher.
NOTE: Only one RTX3 module can be connected to a Spectra SP Series panel.
Programming for EVO
When connected to an EVO panel, the wireless settings are programmed in Module Programming Mode.
To enter Module Programming Mode:
1. Press and hold the [0] key.
2. Enter your [
INSTALLER CODE].
3. Enter section [4003].
4. Enter the module’s [
SERIAL NUMBER]
5. Enter the required [
DATA].
NOTE: When used without a K641 or K641R keypad, enable EVO option [1] in section [3029].
After Programming for EVO
Program the zones, PGMs, and remotes into the EVO panel. Refer to EVO section [3034] and RTX3 section [001]* options [2] and [3] for wireless transmitter supervision options. * For instructions on entering 3-digit RTX3 section numbers, see RTX3 Programming Sections for EVO on page 10.
Page 10
Page 10 Programming
RTX3 Programming Sections for EVO
Section Feature Details
[001] RTX3 options
Option [1] Low battery
supervision
For RTX3 version 1.5 and higher, this option is always On
(default: On). Option [2] Check-in supervision default: Off Option [3] Check-in supervision
time interval
Off = 24 hours (default)
On = 80 minutes Option [4] RF Jamming
supervision
default: Off
Option [5] On-board module
tamper supervision
default: Off
Option [6] PGM1 initial state Off = Normally Open (default)
On = Normally Closed Option [7] PGM2 initial state Off = Normally Open (default)
On = Normally Closed Option [8] Transmitter tamper
signal
Off = RTX3 ignores tamper signal
(default)
On = RTX3 reports tamper signal
[002] Remote control options
Option [1] REM2 Visual and
auditory feedback compatibility options*
Off = Old visual and auditory
feedback (Supported by REM2 V2.00 or lower)
On = New visual and auditory
feedback (default) (Requires REM2 V2.01 or higher with K641 / K641R keypads)
[030] View transmitter, remote and
PGM serial numbers
To view a transmitter’s 6-digit serial
number, press and hold the
transmitter’s anti-tamper switch.
* The new visual and auditory feedback includes the following system statuses: stay armed, inst ant armed and exit delay. Other status feedback has not changed. Note that for REM2 versions 1.04 or older, st ay arm, inst ant arm and exit delay statuses are not supported, and a rejection beep will be heard when the system is in these statuses.
Page 11
Programming Page 11
[101] to [132]
Assign wireless transmitters [101] = Zone Input 1
[132] = Zone Input 32
Enter 6-digit serial number or press
and release the transmitter’s
tamper switch.
To delete an assigned transmitter,
enter 000000 as a serial number.
See text Remote controls To program remotes controls, refer
to User Code and Remote Control
Programming in the EVO
Programming Guide or program
remotes using WinLoad.
NOTE: If programming REM1 /
RAC1/ REM2 / RAC2 / REM15
remotes for a system that does not
include a K641/K641R keypad,
enable EVO option [1] in section
[3029] and refer to “RTX3 Remote
Programming for EVO - Without a
K641/K641R Keypad” on page 14.
[601] to [632]
Transmitter signal str ength [601] = Zone input 1
[632] = Zone input 32
3 or less = weak (move transmitter)
4 to 10 = OK
[701] to [732]
Current battery life [701] = Zone input 1
[732] = Zone input 32
View number of weeks the
batteries have been in the
transmitter.
[801] to [832]
Previous battery life [801] = Zone input 1
[832] = Zone input 32
View number of weeks the
previous batteries were in the
transmitter.
[671] to [678]
2WPGM signal strength [671] = PGM 1
[678] = PGM 8
3 or less = weak (move transmitter)
4 to 10 = OK
Section Feature Details
Page 12
Page 12 Programming
RTX3 PGM Options for EVO
[901] to [908]
Assign 2WPGMs [901] = PGM 1
[908] = PGM 8
Enter 6-digit serial number or press
and release the transmitter’s
tamper switch. To delete an
assigned 2WPGM, enter 000000
as a serial number. If a section
between [901] to [904] is empty , the
RTX3 will use the on-board PGM.
[910] to [989]
PGM programming Program the Two-Way PGM
activation event, deactivation event
and PGM Delay options. Refer to
RTX3 PGM Options for EVO.
[991] View two-way PGM tamper
trouble
PGM # in trouble will be displayed
[992] View tw o-way PGM s upervisi on
trouble
PGM # in trouble will be displayed
PGM Activation
PGM Number Event Group Feature
Group
Start # End #
PGM1 [910] [911] [912] [913] PGM2 [920] [921] [922] [923] PGM3 [930] [931] [932] [933] PGM4 [940] [941] [942] [943] PGM5 [950] [951] [952] [953] PGM6 [960] [961] [962] [963] PGM7 [970] [971] [972] [973] PGM8 [980] [981] [982] [983]
Default Data 000 000 000 000
NOTE: For a complete list of events, refer to the PGM programming section of
your DGP/EVO control panel’s Programming Guide.
Section Feature Details
Page 13
Programming Page 13
* In order to use the “Flexible PGM deactivation” option (option [8]), the “PGM deactivation after option” (option [1]) must be On.
PGM Deactivation
PGM Number Event
Group
Feature Group
Start # End
PGM1 [914] [915] [916] [917] PGM2 [924] [925] [926] [927] PGM3 [934] [935] [936] [937] PGM4 [944] [945] [946] [947] PGM5 [954] [955] [956] [957] PGM6 [964] [965] [966] [967] PGM7 [974] [975] [976] [977] PGM8 [984] [985] [986] [987]
Default Data 000 000 000 000
NOTE: For a complete list of events, refer to the PGM programming section
of your Digiplex or Digiplex EVO control panel’s Programming Guide.
PGM Delay
PGM Number Delay
(000 to 255)
Options
PGM1 [918] [919] PGM2 [928] [929] PGM3 [938] [939] PGM4 [948] [949] PGM5 [958] [959] PGM6 [968] [969] PGM7 [978] [979] PGM8 [988] [989]
Default Data 005 Off
The following options apply to sections [919], [929]... [989]: Option [1]: PGM deactivation after:
See table on right
Option [2]: PGM base time:
On = Minutes Off = Seconds (default)
Option [8]: Flexible PGM deactivation*:
See table on right
[1] [8]
Off Off Deactivation Event Off On Deactivation Event On Off PGM Timer On On PGM Timer or
Deactivation Event
Page 14
Page 14 Programming
RTX3 Remote Programming for EVO
- Without a K641/K641R Keypad
Section Feature Details
[040] to [043]
View or delete used remotes
[040] = remotes 1 to 8 [043] = remotes 25 to 32 After entering the section, select which of the eight remote positions you wish to delete. Any remote position displaying “ ” will be deleted when [
ENTER] is pressed.
[201] to [232]
Assign remote controls to the system
[201] = remote 01 [232] = remote 32 Enter the desired section and then press and hold a button on the remote control until you hear a confirmation beep.
[301] to [332]
Assign remotes controls to users
Assign the remote controls to users by entering a user number (001 to 255) in the appropriate section (Users 001 to 255, section [301] = remote 01, section [332] = remote 32.)
[401] to [432]
Program or delete remote
[401] = remote 01 [432] = remote 32
_____ / _____ / _____ / _____ / _____ / _____ / _____ / _____ (default: 15000000)
[0] = Button disabled [8] = Panic 2 (non­medical) [1] = Regular arm [9] = Panic 3 (fire) [2] = Stay arm [
STAY]= Smoke reset
[3] = Instant arm [
FORCE] = Utility key 1
[4] = Force arm [
ARM] = Utility key 2
[5] = Disarm [
DISARM]= Utility key 3
[6] = Stay / instant disarm [
BYP] = Utility key 4
[7] = Panic 1 (Police) [
MEM] = Utility key 5
[
CLEAR] = Exit without saving [ENTER] = Save data
N/A+N/A
N/A
N/A+N/A
N/A
Page 15
Programming Page 15
Programming for Esprit and Stand Alone
To enter programming mode with Esprit or in Stand Alone mode:
1. Connect an Esprit 636 or 646 to the “Program” connector.
2. Press the “Esprit Mode Programming” button.
3. Press [
ENTER] on your Esprit keypad and enter the installer code
(default: 757575).
4. Enter the desired section number.
Esprit Programming
Section Feature Details
[000] Installer code Set installer code (4 or 6 digits, default:
757575)
[004] PGM initial state
Option [6] PGM1 initial
state
Off = Normally open (default) On = Normally closed
Option [7] PGM2 initial
state
Off = Normally open (default) On = Normally closed
[301] to [332]
User code assignment [301] = User 01
[332] = User 32 Assign a valid user code from the Esprit Panel into the RTX3. To delete a user code, press [
2ND] and then [ENTER].
[201] to [232]
Remote control assignment
[201] = Remote control 01 [232] = Remote control 32 Press [
ENTER]. After the confirmation beep,
press and hold any button on the remote until you hear two beeps. To delete a remote control, press [
2ND]
followed by [
ENTER].
Page 16
Page 16 Programming
Section Feature Details
[401] to [432]
Remote Control Button Options
Option [4] To select
PGM, see section [011]
Enable button for PGM activation (default = On)
Option [5] To select
PGM, see section [012]
Enable button for PGM activation (default = On)
Option [6] To select
PGM, see section [013]
Enable button for PGM activation (default = On)
Option [7] To select
PGM, see section [014]
Enable button for PGM activation (default = On)
Option [8]
Enable button
+ for Panic Alarm
(default = On)
Option [1] Option [2] Option [3] Definition* Off Off Off No Arm or Disarm On Off Off
Button
= Regular Arm (default)
Off On Off
Button
= Regular Arm
On On Off
Button Button
= Regular Arm = Regular Arm
Off Off On
Button
= Force Arm
On Off On
Button Button
= Force Arm = Stay Arm
Off On On
Button Button
= Regular Arm = Stay Arm
On On On
Button
= Stay Arm
[401] = remote control 01 [432] = remote control 32
* Buttons used to arm the system are also used to disarm the system.
Page 17
Programming Page 17
Section Feature Details
[011] to [014]
PGM output activation
[01 1] = Remote Button [012] = Remote Button [013] = Remote Button [014] = Remote Button
Refer to section [401] to [432]
Option [1] Activate PGM
1 output
Default On in section [011]
Option [2] Activate PGM
2 output
Default On in section [012]
Option [3] Activate PGM
3 output
Default On in section [013]
Option [4] Activate PGM
4 output
Default On in section [014]
[021] to [024]
PGM latch / delay
[021] = PGM 1 [024] = PGM 4
(default)
Option [0] Latched Option [1] 1 second Option [2] 5 seconds Option [3] 10 seconds Option [4] 20 seconds Option [5] 40 seconds Option [6] 60 seconds Option [7] 2 minutes Option [8] 4 minutes
[001] Code length
Option [1] Code length On = 6-digit access code length
(default) Off = 4-digit access code length
Option [2] Panic alarm On = Panic alarm toggles PGM and
panic alarm (default) Off = Panic alarm toggles the PGM
Page 18
Page 18 Programming
Stand Alone Use
The RTX3 can be used as a Stand Alone module. The programming sections are the same as when used with an Esprit with the following exceptions:
In Stand Alone mode, section [001], option [1] and option [2] will not affect system use.
Panic alarms can only be used to toggle PGMs on the RTX3 in Stand Alone mode.
Sections [301] to [332] do not have to be programmed.
NOTE: To program wireless transmitters in Stand Alone mode, you must use a PX8 in conjunction with the RTX3. Refer to the PX8 Instructions for more information.
Firmware Upgrade
The RTX3 firmware can be upgraded using either a serial connection or a four­wire connection. For firmware upgrade instructions, refer to the Firmware Upgrade Instructions document which is available at paradox.com > Software > WinLoad. To upgrade an RTX3 on an Imperial system, refer to the RTX3 chapter in the Imperial System Guide.
Section Feature Details
[002] PGM output on panic
Option [0] No PGM output on panic alarm Option [1] Toggle PGM 1 on panic alarm Option [2] Toggle PGM 2 on panic alarm Option [3] Toggle PGM 3 on panic alarm (default) Option [4] Toggle PGM 4 on panic alarm
[003] RF lockout on panic
Option [0] No RF signal lockout on panic alarm (default) Option [1] 30-second RF signal lockout on panic alarm Option [2] 60-second RF signal lockout on panic alarm Option [3] 90-second RF signal lockout on panic alarm Option [4] 120-second RF signal lockout on panic alarm
Page 19
Page 19
Index
Sections
2WPGM
Assigning
................................................................................................... 12
Signal strength ...........................................................................................11
A
Antennas .......................................................................................................... 6
Anti-tamper switch .............................................................................................6
Assign wireless transmitters ..............................................................................11
B
Battery life ......................................................................................................11
C
Check-in supervision ........................................................................................10
Check-in supervision time interval ......................................................................10
Code length ....................................................................................................17
Compatibility .....................................................................................................4
Consumption ................................................................ ..................................... 4
Current battery life ...........................................................................................11
Current consumption ..........................................................................................4
D
Dimensions ....................................................................................................... 4
E
Esprit .............................................................................................................15
Esprit mode ... ..................... ..................... ..................... ..................... ................6
EVO ................................................................................................. ................ 9
F
Firmware upgrade ............................................................................................ 18
Frequency ........................................................................................................4
I
Imperial ............................................................................................................8
Input voltage .....................................................................................................4
Installation ........................................................................................................7
Installer code ...................................................................................................15
Page 20
Page 20
K
K641 ................................................................................................................ 9
L
LED display .......................................................................................................6
LED feedback ................................................................................................6, 8
Low battery supervision ....................................................................................10
M
Module programming mode (EVO) .......................................................................9
Mounting clips ...................................................................................................6
O
On-board module tamper supervision .................................................................10
Operating temperature ........................................................................................ 4
P
Panic alarm ..................................................................................................... 17
PGM
Activation
................................................................................................... 12
Deactivation ...............................................................................................13
Delay ........................................................................................................13
initial state ............................................................................................10, 15
Latch / delay ...............................................................................................17
Options for EVO ............. .......................................... ...................................12
Output activation ........................................................................... ..............17
output on panic ........................................................................................... 18
outputs ........................................................................................................4
Programming ..............................................................................................12
Supervision trouble ......................................................................................12
Tamper trouble ........................................................................................... 12
Power input voltage ............................................................................................ 4
Previous battery life .......................................................................................... 11
Programming ....................................................................................................8
Programming button ........................................................................................... 6
R
REM2 visual and auditory feedback .................................................................... 10
Remote control assignment ...............................................................................15
Remote control button options ...........................................................................16
Remote controls ..............................................................................................11
Reset ............................................................................................................... 7
RF Jamming supervision ................................................................................... 10
RF lockout on panic ..........................................................................................18
Page 21
Page 21
S
Sensitivity .........................................................................................................4
Signal strength ................................................................................................11
Specifications .................................................................................................... 4
Spectra SP series ..............................................................................................9
Stand alone ...............................................................................................15, 18
System reset .....................................................................................................7
T
Temperature .....................................................................................................4
Transmitter signal strength ................................................................................11
Transmitter tamper signal ..................................................................................10
U
User code assignment ...................................................................................... 15
V
View serial numbers .........................................................................................10
Voltage .............................................................................................................4
W
Warranty .........................................................................................................22
Wireless transmitter supervision options ................................................................ 9
Wiring slot .........................................................................................................6
Page 22
Page 22
Patents:
One or mo r e o f the following US patents ma y a p p l y : 7046142, 6215399,
6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply.
Trademarks: Imperial, EVO, Spect r a SP Series and Esprit are trademarks of Paradox
Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
Certification: For the latest information on products approvals, such as UL and CE,
please visit www.paradox.com.
Warranty: For complete warranty information on this product please refer to the Limited
Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. © 2010 Paradox Security Systems Lt d . All r igh t s re se rve d. Specifications may change without prior noti c e.
Page 23
Page 24
RTX3-EI10 05/2010 PARADOX.COM Printed in Canada
For technical support in Canada or the U.S., call 1-800-791-1919,
Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. For technical
support outside Canada and the U.S., call 00-1-450-491-7444,
Monday to Friday from 8:00 a.m. to 8:00 p.m. EST.
Please feel free to visit our website at www.paradox.com.
Loading...