Liquid Controls SP1200 User Manual

INSTALLATION & OPERATION
MANUAL
MODEL SP1200
Flo-Calibration System
DOC#: MN-1200
WARNING
Never drop any component of the prover system-carefully place each component in desired location.
The Temperature Probe MUST be removed before installation or removal of transition piping. The probe is easily damaged by any type of shock.
All prover runs are to be made using temperature compensation.
PROCEDURES
Assemble prover piping on the discharge of the trailer to be proved. The prover MUST be
supported.
Install the temperature probe.
Connect all wiring to the prover.
Cool down piping by allowing liquid to flow. You may pump off for a short period of time to complete cool down.
DURING COOL DOWN
Note the calibration factor entered on the trailer’s totalizer.
Set up the SP1200 for the prover run.
the “CLEAR/FEED” key to erase the entire line typed, or press the “ typed. Press the “ENTER” key when the number is correct.
NOTE: Numerical data will be typed by pressing the desired digit keys. If a mistake is made, press
” key to erase the last number
INITIAL SET-UP MODE
<<<<<<<<>>>>>>>
Product
= Fact or
1 = Clock
3 = Factor
1 = Clock
3 = Factor
Hold down “RESET” key and turn power “ON” The prover “SET-UP” menu will be displayed.
Press “PRINT” key Set-up ticket will be printed.
Example:
2 = RTD
Fl o- cal set up
03: 35P 14-Jul -
4 = More
>
97
0 - LOX 1 - LIN 2 - LAR 3 - LCO2 4 - LN20 5 - CC02 6 - MAPP 7 - LPG
R = . 4063 T = . 779419 R = . 4063 T = . 63051 R = . 4063 T = . 761813 R = . 4063 T = . 057356 R = 0 T = 0 R = . 4063 T = . 057356 R = 0 T = 0 R = 0 T = 0
Note: Each SP1200 is factory calibrated for products and engineering units of total as specified by user.
Calibration Factors
Rate is always Gallons per minute (Gm) Rfactor = 60/K Totalization may be any engineering units. Tfactor - Engineering Units/K
The prover “SET-UP” menu will be displayed.
2 = RTD
4 = More
NOTE: If prover was factory calibrated DO NOT select Set-up option “3-Factor”. If printed set-up data is incorrect, incomplete or missing call factory.
Select “1-Clock” by pressing “1” key.
Minutes:
1-Am, 2-Pm
Date:
Month:
Year:
Hours:
Enter the correct hour (1-12). The number entered will be displayed on the second line of the display. Press “ENTER” key.
Enter the correct minutes (0-59). The minute entered will be displayed on the second line of the display. Press “ENTER” key.
Press “1” key if correct time is “AM” or Press “2” key if correct time is “PM”. Press “ENTER” key.
Enter the correct date (1-31). Press “ENTER” key.
Enter the correct month (1-12). Press “ENTER” key.
Enter the correct year (1-99). Press “ENTER” key.
“SET-UP” menu will
1 = Clock
3 = Factor
Product Number?
Product Number?
0 = LOX
Rfactor?
0 = LOX
Tfactor
PRODUCT SELECTOR
be displayed:
2 = RTD
4 = More
“2-RTD” should not be selected. This is a factory calibration function. Select “3-Factor” by pressing “3” key.
***NOTE: To exit the “SET-UP” menu press “RESET” key.
Select desired product and press corresponding key.
To retain displayed Rfactor: Press “RESET” key, display will advance. To change displayed Rfactor: Press “CLEAR/FEED” key. Enter new Rfactor, Press “ENTER” key, display will advance.
To retain displayed Tfactor: Press “RESET” key, display will advance. To change displayed Tfactor: Press “CLEAR/FEED” key, Enter new Tfactor, Press “ENTER” key, display will advance.
To continue “FACTOR”: Select desired product, press corresponding key. To exit the “FACTOR” menu: Press “RESET” key, “SET-UP” menu will be displayed:
0 = LOX 1 = LIN 2 = LAR 3 = LCO2 4 = N20 5 = CCO2 6 = MAPP 7 = LPG
.30456
.005076
Repeat.
1 - Meter
3 - Tractr
1 = Clock
3 = Factor
1 - Meter
3 - Tractr
1 - Meter
3 - Tractr
Plant:
2 = RTD
4 = More
Select “4=More” by pressing “4” key. “MORE” menu will be displayed.
2 - Plant
4 - Trailr
Select “1-Meter” by pressing “1” key.
Press “CLEAR/FEED” key: Enter serial number of turbine meter under test, Press “ENTER” key: “MORE” menu will again be displayed.
Select “2=Plant” by pressing “2” key
Press “CLEAR/FEED” key. Enter Plant number, Press “ENTER” key. “MORE” menu will again be displayed.
Meter:
2 - Plant
2 - Plant
4 - Trailr
4 - Trailr
Select “3 - Tractr” by pressing “3” key.
Tractor:
1 - Meter
3 - Tractr
1 - Meter
3 - Tractr
1 = Clock
3 = Factor
Press “CLEAR/FEED” key. Enter Tractor number, Press “ENTER” key. “MORE” menu will again be displayed.
2 - Plant
4 - Trailr
Select “4 - Trailr” by pressing “4” key.
Trailer:
Press “CLEAR/FEED” key. Enter Trailer number, Press “ENTER” key. “MORE” menu will again be displayed.
2 - Plant
4 - Trailr
Press “RESET”. “SET-UP” menu will again be displayed:
2 = Intro
4 = More
Initial set-up is complete, Press “RESET” key to change to the OPERATING SET-UP MODE.
SET-UP OPERATING MODE
LIN 00:00P
00-Mar-00
Press any key
**Flo-Cal**
Press CLEAR to
Enter new
LIN
No T/C
LIN
to continue
SP1200 will alternate these 2 displays until “RESET” is pressed. Correct product must be displayed in the upper left hand corner.
Gm 0
No T/C GO PROVE
To change product, press key.
change product
Press “CLEAR/FEED” key.
product #
Enter product number desired:
PRODUCT SELECTOR 0 = LOX 1 = LIN 2 = LAR 3 = LCO2 4 = N20 5 = CCO2 6 = MAPP 7 = LPG
With correct product displayed, check in upper right hand corner of the display for a temperature reading or the words “No T/C”. If “No T/C” is displayed, press the “TC TOGGLE” key to switch on the temperature compensation.
Gm 0
GO PROVE
Gm 0
-198.8c GO PROVE
**All prover runs are to be made using temperature compensation. **If “+426H” is displayed, the temperature probe or cable is open. **If “-270.9L” is displayed, the temperature probe or cable is shorted.
PROVING MODE
Cool down is verified by the temperature display. The temperature displayed along with a small “c” indicates
LIN
LIN
LIN
LIN
Press any key
Start reading?
the prover piping is cooled down. The temperature displayed with “H” indicates temperature is high; with “L” indicates temperature is low (out of range).
Gm 0
-198.8c GO PROVE
NOTE: The temperature correction factor (TCF) may be viewed by pressing & holding the “ENTER” key.
TCF: 1
No T/C
TCF: 1.012512
-198.8c
Start trailer product pump. Once primed, turn on the trailer totalizer. After pumping 50 gallons, note the trailer totalizer reading as the START/STOP switch is pressed & released. This starts the prover run. Continue to pump another 500 gallons according to the trailer totalizer.
As the prover progresses, check the prover flow rate display (Gm). With 1 1/2” prover system, pump off rate should be at a normal 100 gallons per minute (Gm) and 180 gallons per minute (Gm) for a 2” system.
Gm 100
-198.8c Tt 125
After pumping at least 500 gallons or equivalent according to the trailer totalizer, depress and release the START/STOP switch. Note the trailer totalizer reading. The prover will display:
NOTE: The “Tt” will display the actual TOTAL for the prover run
.
Gm 100
Tt 500
Press any key. Enter data as prompted by the display:
Enter the trailer totalizer reading noted at the start of the prover. Press “ENTER” key.
Enter the CF from the trailer totalizer.
Enter the KF from the trailer totalizer.
Enter CF?
Enter KF?
Set new CF:
Set new KF:
Enter cal type
LIN
-198.8c
End reading?
Gm 120
GO PROVE
Enter the trailer totalizer reading noted at the end of the prover. Press “ENTER” key
0=CF / 1=KF?
Enter the type of Factor used to calibrate the trailer totalizer. Press “0” if CF (Calibration Factor = 1/K) or press “1” if KF (K-Factor direct entry for calibration) Press “ENTER” key
Press “ENTER”
Examples ONLY!
*********************** Calibration information 10:19A 11-Mar-97 Meter : 44795 Plant : 815 Tractor : 456 Trailer : 789
LIN -198.8c Delivry GPM: 100. Calib total: 101 Delivry TCF: 1.012512
- - ­Truck start: 0 Truck stop : 100 Truck total: 100 Truck C/K : CF Truck Factr: .1
- - ­Truck % err: -.990 Set new CF: .1010
XXXX
Press “ENTER”
XXXX
Press “PRINT” key
Additional prove tickets may
be printed by pressing the
“PRINT” key.
*********************** Calibration information 10:19A 11-Mar-97 Meter : 44795 Plant : 815 Tractor : 456 Trailer : 789
LIN -198.8c Delivry GPM: 100. Calib total: 101 Delivry TCF: 1.012512
- - ­ Truck start: 0 Truck stop : 100 Truck total: 100 Truck C/K : KF Truck Factr: 1
- - ­ Truck % err: -.990 Set new KF: .9901
***NOTE: If incorrect data was entered press “ENTER” & reinsert prove data. Dial the “New CF” or “New KF” into the trailer totalizer. Press “RESET” key.
Reprove the trailer.
Compare the prover totalizer reading to the trailer totalizer.
Truck % error should be within specified tolerance.
Repeat as necessary.
Proceed with sealing the trailer meter box.
Affix calibration decal.
Complete documentation. (Work order)
If several trailers will be proved, the prover piping should be assembled and cooled within 15 minutes. If this cannot be done, the piping will need to be blown dry using nitrogen. DO NOT USE SHOP AIR.
WARNING: Condensation will quickly form inside piping left unattended. This will cause ice to form on the turbine bearings, preventing rotation and rendering the prover inoperable.
When all proving has been completed, CLEAN and DRY prover system. Place all components including temperature probe and all cables in proper case for storage.
©2009
Pub. No. MN-1200-Rev
(09/09)