DELAY-ON-REVERSE 1PH
Modification, K-Line
71-9092061
APPLICATION REQUIREMENTS:
This modification is available to models T, GT, J, H, GH, SD and GSD standard door operators
with 24V control circuits. This modification is standard on Model GH-300. Not for use with
Solid State Logic Control Boards (L).
The operator must have C2/B2 wiring (not for Medium Duty Operators).
Recommended for heavy doors and where frequent reversing may be expected due to
high usage.
FUNCTIONS:
Modifies the operator control circuit so the the door must stop for one second before reversing,
in either direction. This delay allows the door and operator to come to a more complete stop
than would happen if there was no delay.
Prevents shock loading of the door and operator especially if a safety device or other
open override is activated during closing, resulting in a longer life of the operator.
This delay has no effect on starting an operator that has been stopped for longer than
2 seconds.
PREPARATION:
Unpack kit to verify the parts listed below are included. Refer to installation instructions on
reverse side.
PACKING LIST:
PART NUMBER
01-11721
01-0171-A
*24-115-03
**24-230-5
24-264-4
27-10199
71-11606
82-PX06-06
84-ST-06
95-BL11-68
95-OR04-38
95-PU04-38
DELAY-ON-REVERSE INSTRUCTION SHEET 1PH OPERATORS
DELAY ON REVERSE 1PH WIRING DIAGRAM
RELAY, SMALL TPDT, 115V
RELAY, 3PDT (IR)
RELAY, 24VDC COIL, DPDT
WIRE TIES
TIME DELAY ASSEMBLY
SCREW, #6-32 x 3/8” PAN HEAD PHILLIPS
#6 TINNERMAN
WIRE, BLUE 11” 16GA. .250” FORK x .187” INS. FASTON
WIRE, ORANGE 4” 18GA. .187” FASTON x .187” INS.FASTON
WIRE, PURPLE 4” 18GA. .187” FASTON x .187” INS.FASTON.
DESCRIPTION
QUANTITY
1
1
1
1
1
3
1
4
4
1
1
1
* Used on 115V Operators
** Used on 230V Operators
INSTALLA TION INSTRUCTIONS
1. DISCONNECT POWER
2. Locate the IR (instant reverse) relay-line voltage
coil with 6 wires: 2 black, 1 red, 1 purple, 1 orange
and 1 yellow. Exchange this relay with the 3PDT
relay provided. Be sure that the new relay has the
same coil voltage as the existing relay. Connect the
wires from the original relay to the new relay (refer to
figure 1).
FIGURE 1
RED
INSTANT REVERSE
(IR) RELAY
YELLOW
NC
NC
NO
NO
C
COIL
C
PURPLE
BLACK
COIL VOLTAGE
SAME AS LINE
VOLTAGE
BLACK
ORANGE
3. Install the 24VDC relay in a convenient location, if
possible install close to the IR relay from step 2. This
is the TD relay.
4. Use figure 2 to assist with the rest of the
installation instructions.
5. Unplug the yellow wire from the IR relay and plug
it into the normally closed (NC) terminal of the TD
relay.
Install an orange jumper from the common (C)
terminal of the TD relay, that corresponds to the
yellow wire, to the normally open (NO) terminal of the
IR relay where the yellow wire was.
6. Unplug the red wire from the IR relay and plug it
into the normally closed (NC) terminal of the TD relay.
Install a purple jumper from the common (C) terminal
of the TD relay, that corresponds to the red wire, to
the normally open (NO) terminal of the IR relay where
the red wire was.
7. Plug the TD module onto the two coil terminals of
the TD relay. Connect the white into the wire nut that
contains at least 3 wires (1 yellow from transformer, 1
orange from open limit and 1 purple from close limit there may also be one or two red wires in this wire
nut). Be sure the other wires al remain in the wire
nut.
8..Connect the orange wire to the center of the
normally closed (NC) terminal of the IR relay.
9. Connect the blue wire from terminal 3 to the center
common (C) of the IR relay - this terminal
corresponds to the orange to the orange wire just
installed that came from the TD module.
10. Whenever the operator is running and the open
override is activated-safety edge or radio control or
open button, etc. - the delay provides for a delay
before the operator will open. This delay does not
delay the stopping action, just the restart. This delay
does not cause a delay on starting an operator from
rest as long as the operator has been at rest for over
the delay period.
TERMINAL
#3
NEW PURPLE JUMPER
PURPLE
RED FROM IR
BLACK
BLUE
01-11721D All Rights Reserved
NC
NC
NO C
NO C
ORANGE
COIL
IR RELAY
BLACK
ORANGE
NEW ORANGE JUMPER
© 1998, The Chamberlain Group, Inc.
TD RELAY
YELLOW FROM IR
NC
NO C
COIL
RED
ORANGE
PURPLE
YELLOW
MODULE
FIGURE 2
EXISTING
WIRE
NUT
WHITE
TD