APPLICATION REQUIREMENTS:
This modification is available to models T, GT, J, H, GH, SD and GSD standard door operators with 24V control circuits. This modification is standard on Model GH-300. Not for use with Solid State Logic Control Boards (L).
The operator must have C2/B2 wiring (not for Medium Duty Operators). Recommended for heavy doors and where frequent reversing may be expected due to
high usage.
FUNCTIONS:
Prevents shock loading of the door and operator especially if a safety device or other open override is activated during closing, resulting in a longer life of the operator.
This delay has no effect on starting an operator that has been stopped for longer than 2 seconds.
PREPARATION:
Unpack kit to verify the parts listed below are included. Refer to installation instructions on reverse side.
PACKING LIST:
PART NUMBER
01-11721 01-0171-A *24-115-03 **24-230-5 24-264-4 27-10199 71-11606 82-PX06-06 84-ST-06 95-BL11-68
95-OR04-38 95-PU04-38
DELAY-ON-REVERSE INSTRUCTION SHEET 1PH OPERATORS DELAY ON REVERSE 1PH WIRING DIAGRAM RELAY, SMALL TPDT, 115V RELAY, 3PDT (IR) RELAY, 24VDC COIL, DPDT WIRE TIES TIME DELAY ASSEMBLY SCREW, #6-32 x 3/8” PAN HEAD PHILLIPS #6 TINNERMAN WIRE, BLUE 11” 16GA. .250” FORK x .187” INS. FASTON
WIRE, ORANGE 4” 18GA. .187” FASTON x .187” INS.FASTON WIRE, PURPLE 4” 18GA. .187” FASTON x .187” INS.FASTON.
DESCRIPTION
QUANTITY
1 1 1 1 1 3 1 4 4 1
1 1
* Used on 115V Operators ** Used on 230V Operators
INSTALLA TION INSTRUCTIONS
1. DISCONNECT POWER
2. Locate the IR (instant reverse) relay-line voltage coil with 6 wires: 2 black, 1 red, 1 purple, 1 orange and 1 yellow. Exchange this relay with the 3PDT relay provided. Be sure that the new relay has the same coil voltage as the existing relay. Connect the wires from the original relay to the new relay (refer to figure 1).
FIGURE 1
RED
INSTANT REVERSE (IR) RELAY
YELLOW
NC
NC
NO
NO
C
COIL
C
PURPLE
BLACK
COIL VOLTAGE SAME AS LINE VOLTAGE
BLACK
ORANGE
3. Install the 24VDC relay in a convenient location, if possible install close to the IR relay from step 2. This is the TD relay.
4. Use figure 2 to assist with the rest of the installation instructions.
5. Unplug the yellow wire from the IR relay and plug it into the normally closed (NC) terminal of the TD relay.
Install an orange jumper from the common (C) terminal of the TD relay, that corresponds to the yellow wire, to the normally open (NO) terminal of the IR relay where the yellow wire was.
6. Unplug the red wire from the IR relay and plug it into the normally closed (NC) terminal of the TD relay. Install a purple jumper from the common (C) terminal of the TD relay, that corresponds to the red wire, to the normally open (NO) terminal of the IR relay where the red wire was.
7. Plug the TD module onto the two coil terminals of the TD relay. Connect the white into the wire nut that contains at least 3 wires (1 yellow from transformer, 1 orange from open limit and 1 purple from close limit ­there may also be one or two red wires in this wire nut). Be sure the other wires al remain in the wire nut.
8..Connect the orange wire to the center of the normally closed (NC) terminal of the IR relay.
9. Connect the blue wire from terminal 3 to the center common (C) of the IR relay - this terminal corresponds to the orange to the orange wire just installed that came from the TD module.
10. Whenever the operator is running and the open override is activated-safety edge or radio control or open button, etc. - the delay provides for a delay before the operator will open. This delay does not delay the stopping action, just the restart. This delay does not cause a delay on starting an operator from rest as long as the operator has been at rest for over the delay period.
TERMINAL
#3
NEW PURPLE JUMPER
PURPLE
RED FROM IR
BLACK
BLUE
01-11721D All Rights Reserved
NC
NC
NO C
NO C
ORANGE
COIL
IR RELAY
BLACK
ORANGE
NEW ORANGE JUMPER
© 1998, The Chamberlain Group, Inc.