LG Multi V ARNU07GTJ 2 Series, Multi V ARNU09GTJ 2 Series, Multi V ARNU12GTJ 2 Series Svc Manual

Multi V Air Conditioner
SVC MANUAL(Exploded View)
MODEL : ARNU07GTJ*2 ARNU09GTJ*2 ARNU12GTJ*2
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
http://biz.lgservice.com
1. Specification
* Model Name
A:Basic, C:Plasma
Type Model Unit
kW
Cooling Capacity kcal/h
Btu/h
kW
Heating Capacity kcal/h
Btu/h
Casing
Body
Dimensions (WxDxH)
Front Panel
Coil
Rows x Columns x FPI Face Area m
mm
inch
mm
inch
2
Type Motor Output x Number
W
Running Current A
Fan Air Flow Rate(H/M/L) CMM
cfm Drive Motor type
Temperature Control Sound Absorbing Thermal Insulation Material Safety Device
Liquid Side mm(inch)
Pipe Connections
Gas Side mm(inch) Drain Pipe(Internal Dia.)
mm
Net Weight Body kg(lbs) Noise Level
(Sound Press, 1.5m, H/M/L)
dB(A)
Power Supply Ø, V, Hz
Refrigerant Control Power cable Transmission cable Panel Color Panel Name(Acc'y)
1Way Ceiling Cassette
ARNU07GTJ*2 ARNU09GTJ*2 ARNU12GTJ*2
2.2 2.8 3.6 1,900 2,400 3,100 7,500 9,600 12,300
2.5 3.2 4.0 2,200 2,800 3,400 8,500 10,900 13,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
860x410x138 860x410x138 860x410x138
33.8x16.1x5.4 33.8x16.1x5.4 33.8x16.1x5.4 1,070x480x20 1,070x480x20 1,070x480x20
42.1x18.9x0.8 42.1x18.9x0.8 42.1x18.9x0.8 2x9x21 2x9x21 2x9x21
0.13 0.13 0.13
Cross Flow Fan Cross Flow Fan Cross Flow Fan
20.0 20.0 20.0
0.18 0.18 0.18
7.5/6.5/6 7.5/6.5/6 8/7/6
265/229/212 265/229/212 283/247/212
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Fuse Fuse Fuse Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
25.0 25.0 25.0
11.5(25.4) 11.5(25.4) 11.5(25.4) 40/38/37 40/38/37 41/39/37
1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C CVV-SB 1.25 x 2C
Morning fog Morning fog Morning fog
PT-HJ
*
Notes:-
1. Capacities are based on the following conditions: Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
- 2 -
Conversion Formula
kcal/h= kW x 860 Btu/h = kW x 3412 cfm = m3/min x 35.3 l/s = CMM x 1000/60
LGE Internal Use Only
2. List of Functions
FunctionCategory
Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right)
Air flow
Air purifying Plasma air purifier
Installation
Reliability Self diagnosis
Convenience Forced operation
Individual Deluxe wired remote controller control Simple wired remote controller
Special function kit
Auto swing(up & down) Airflow steps(fan/cool/heat) Chaos swing Chaos wind(auto wind) Jet cool(Power wind) Swirl wind Deodorizing filter
Prefilter(washable / anti-fungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start
Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock
Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Wide Character wired remote controller Picto wired remote controller
Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Zone control CTIE Electro thermostat
ARNU07GTJ*2, ARNU09GTJ*2, ARNU12GTJ*2
1
-
auto
-
O
4/5/4
X O O
-
X
Option
O O O X O O O O
O(only heat recovery)
X
O(only heat pump or cooling only)
O O O O O O O O
Accessory
Accessory
Accessory Accessory Accessory
X
Accessory
-
-
-
O : Applied X : Not applied – : No relation Option : Model name & price are different according to options, and assembled in factory with main unit. Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate