Overview

Overview
Components
The Leica DISTO™ isa laser distance meter oper­ating with a class 2 laser. See chapter Technical
data for scope of use.
5Add/ Navigate left
6Enter/ Equal
7Selection keys linked to symbols above
8Functions
9Subtract/ Navigate right
10Measuring reference/ Navigate downwar ds
Basic measuring screen
1Status bar
2Main line
3Active function
4Favorites
1Display
2ON/ Measure
3Clear/ OFF
4Memory/ Navigate upwards
2
Overview
Selection screen
1Function/ Settings
2Settings
3Help function
4Page indicator
Icons on status bar
Scrolldown for further results
Battery power
Bluetooth® isswitched on
Bluetooth® connectionestablished
Measuring reference
Device is measuring
Offset is activated and adds/substracts the defined value from measuring dis­tance
Device is levelled
Device is not levelled
3

Technical data

Tech nicaldata
General Accuracywith favourable conditions * 1 mm / 0.04" *** Accuracywith unfavourable conditions** 2 mm / 0.08" *** Range with favourable conditions* 0.05 - 150m / 0.16 - 500ft *** Range with unfavourable conditions ** 0.05 - 80m / 0.16 - 260ft *** Smallest unit displayed 0.1 mm / 1/32 in X-Range Power Technology yes Laser class 2 Laser type 635 nm, <1 mW ø laser point | at distances 6 /30 /60 mm | 10/ 50/ 100 m Tilt measuring tolerance to laser beam **** ± 0.2° Tilt measuring tolerance to housing **** ± 0.2° Tilt measuring range **** 360° Protection class IP65 (dust- and splash water protected) Auto. laser switch off after 90 s Auto. power switch off after 180 s
Bluetooth® Smart Bluetooth® v4.0
Power of Bluetooth® Smart 0.71 mW
Frequency of Bluetooth® Smart 2400 - 2483.5 MHz
Range of Bluetooth® Smart <10m
Battery durability(2 x AA) up to 4000 measurements
Dimension (H x D x W) 132 x 56 x 29 mm | 5.2 x 2.2 x 1.1 in
Weight ( with batteries) 184 g/ 6.49 oz
Temperature range Storage | Operation -25 to 70°C/ -13 to 158°F | -10 to 50°C/ 14 to 122°F
* favourable conditions are: white anddiffuse reflectingtarget (w hite painted wall), low background illu-
minationand moderate temperatures.
** unfavourable conditions are:targets w ith lower or higher reflectivity or high background illumination or
temperatures at the upper or l ower end of thespecified temperature range.
*** Tolerances apply from 0.05 m to 10 m with a confidencelevel of 95%.
With favourable conditions the tolerancem ay deteriorate by 0.10 m m/m for distances above 10 m.
With unfavourable conditions the tolerancem ay deteriorate by 0.15 m m/m for distances above 10 m.
**** after user calibration. Additional angle r elated deviation of +/-0.01° per degree up to +/-45° in each quad-
rant.
Applies at room temperature. For the whole operating temperature range the maximum deviation
increases by +/-0.1°.
4
Technical data
Func tions Distance measuring yes Min/Max measuring yes Permanent measuring yes Stake out yes Addition/Subtraction yes Area yes Room angle yes Volume yes Painter function (area with partial measurem.) yes Pythagoras 3-point Smart Horizontal Mode / Indirect height yes Level yes Memory yes Beep yes Illuminated colour display yes
Bluetooth® Smart yes
Personalized Favorites yes
Timer yes
Point to point function/ distance yes *****
Smart Area yes *****
***** In combination w ith Leica DST 360 adapter
5

Instrument Set-up

InstrumentSet-up
Introduction
The safety instructions (see Safety
Instructions) and the user manual
should be read through carefully before the product isused for the first time.
The person responsible for the product must ensure that all users understand these directions and adhere to them.
The symbols used have the following meanings:
WARNING
Indicatesa potentiallyhazardous situ­ation or an unintended use which, if not avoided, willr esult in death or ser­ious injury.
CAUTION
Indicatesa potentiallyhazardous situ­ation or an unintended use which, if not avoided, may result in minor injury and/or appreciable material, financial and environmental damage.
Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner.
6
Instrument Set-up
Insert batteries
To ensure a reliable use, we recommend using high quality Alkaline batteries. Change bat­teries when battery symbol is flashing.
Switching ON/OFF
Device is tur ned OFF.
7
Instrument Set-up
Clear
Undo last action. Leave actualfunction, go to default
operation mode.
Message Codes
If the message "i" appears with a number, observe the instruc­tions in Message Codes section. Example:
8
Instrument Set-up
Multifunctional endpiece
When measuring with 90° flipped-out endpiece please meake sure that it lies plane against the edge you measure from.
The orientation of the endpiece isautomaticallydetected and the zero point isadjusted accord­ingly.
Adjusting measuring reference
a) Distance ismeasured from the rear of the device (standard setting).
b) Distance ismeasured from the front of the device.
c) Distance is measured from the tri­pod thread.
d) Distance ismeasured from a Leica DISTO Adapter F TA 360.
Confirm setting.
If device isswitched off, ref­erence goes back to standard setting (rear of the device).
9

Settings

Settings
Overview
Tilt units
Distance units
Turning screen**
Beep
Bluetooth®
Bluetooth® settings
Illumination
Favorites
Keypad lock
Tilt calibration
Information / Serial number
Offset
Calibration of DST 360*
Reset
* Activatedwhenconnected to Leica DST 360
adapter
** F irmware update mi ght be requiredthrough the
Leica DISTO™PlanAppto getthis feature
10
Settings
Tilt units
Switch between the following units:
360.0°
0.00 %
Confirm setting. Exitsettings.
11
Settings
Distance units
Switch between the following units:
0.00 m
0.00 ft
0.000 m
0.000 in
0.0000 m
0'00" 1/32
0.0 mm
0 in 1/32
Confirm setting. Exitsettings.
12
Settings
Turning screen ON/OFF*
* Firmware update might be required through the
Leica DISTO™PlanAppto getthis feature
To switch ON, repeat procedure. Exitsettings.
13
Settings
Beep ON/OFF
To switch ON, repeat procedure. Exitsettings.
14
Settings
Bluetooth® ON/OFF
Bluetooth® isswitched on and blackBluetooth® icon is dis­played in status bar . If con­nection is established the color of the icon changes to blue.
To switch ON, repeat procedure. Exitsettings.
15
Settings
Bluetooth® Settings
Confirm setting. Select kind of decimalpoint for trans-
mitted value.
If activated in measuring mode, it allowsthe arr ow keys to move the cursor on your computer.
Short press: send the value of the main line to your computer. Long press: send allmeasurements and results to your computer .
Select ON or OFF .
If device isconnected, the favor­ites disappear and two softkeys appear:
Confirm setting. Select if unit is transmitted or not.
16
Settings
Confirm setting. Select termination of transmission. Confirm setting. Select if value is transmitted auto-
matically or manually.
Confirm setting. Exitsettings.
17
Loading...
+ 42 hidden pages