Kyocera FS-C8020MFP, FS-8025MFP SERVICEBULLETINS 2KZ 0029 C208

(Page.1/2)
Correction of the Service Manual (Initial Setting Values of the Maintenance Mode U161 and U101)
Model l:
FS-C8020MFP, FS-C8025MFP
Initial setting*
Initial setting
Section
Item No.
Content of maintenance item
20ppm
25ppm
20ppm
25ppm
Fuser
U161
Setting the fuser control temperature
210/210/240/240/190/ 190/95/100/85/90/110/ 115/135/140/140/145/ 140/145/115/120/135/ 140/240/240/85/90/40/ 45/200/200/85/90
210/240/190/ 95/85/110/ 135/140/140/ 115/135/240/ 85/40/200/85
210/240/190/ 100/90/115/ 140/145/145/ 120/140/240/ 90/45/200/90
Setting
Initial
Initial setting
Display
Description
range
setting
20ppm
25ppm
Copy Curb (Edge)
Prevention temperature of over­temperature rise under copy
100 to
250
210
210
210
Curb (Edge)
Prevention temperature of over­temperature rise
100 to
250
240
240
240
Return (Edge)
Return temperature of over­temperature rise
100 to
250
190
190
190
Ready (Edge)
Ready display temperature
0 to 200
140 95
100
Pressure (Press)
Pressurizing beginning temperature
0 to 200
100 85
90
High speed (Center)
Full speed shift temperature
0 to 200
130
110
115
Ready (Center)
Ready display temperature
100 to
200
150
135
140
Drive (Center)
The second stability temperature
100 to
200
160
140
145
Full speed (Center)
Print control temperature
100 to
200
160
140
145
Wait (Center)
Control temperature when being standing by
100 to
200
130
115
120
WarmUp Curb (Center)
Electric power control temperature at start-up
0 to 200
160
135
140
Curb (Center)
Prevention temperature of over­temperature rise
170 to
250
240
240
240
Low power (Center)
Low electric power control temperature
0 to 200
90 85
90
Ready (Press)
Ready display temperature
0 to 200
60 40
45
Curb (Press)
Prevention temperature of over­temperature rise
170 to
250
240
200
200
Wait Offset (Press)
Correction temperature when being standing by
0 to 200
100 85
90
Service Bulletin Ref. No. 2KZ-0029 (C208)
[Service Information] <Date> August 2, 2012
Topic
The initial setting values of the maintenance mode U161 and U101 mistakenly described in the Service Manual (Rev.6 and before) were corrected as follows. The correct values are already in the Service Manual (Rev.7: Revised in July, 2012).
Maintenance mode item list (in the Service Manual 1-3-1 (2))
(Wrong) (Correct)
* The initial settings for 20 ppm and 25 ppm were described together.
Content of the maintenance mode items (in the Service Manual 1-3-1 (3))
<U161: Setting the fuser control temperature> (Wrong) (Correct)
KYOCERA Document Solutions Europe
Technical Customer Service Division (TCSD)
(Page.2/2)
Setting
Initial Initial setting
Display
Description
range
setting
20ppm
20ppm
Full
Full speed printing
0 to 100
55 44
55
Half
Half speed printing
0 to 100
35 35
35
Setting
Initial Initial setting
Display
Description
range
setting
20ppm
25ppm
1st
Correction value (Yellow)
-50 to 50
0/-3 0/-2
0/-3
2nd
Correction value (Cyan)
-50 to 50
15/-3
12/-2
15/-3
3rd
Correction value (Magenta)
-50 to 50
5/-3 4/-2
5/-3
4th
Correction value (Black)
-50 to 50
20/-3
16/-2
20/-3
Setting
Initial Initial setting
Display
Description
range
setting
20ppm
20ppm
Value
Correction value
-50 to 50
10 8
10
Service Bulletin Ref. No. 2KZ-0029 (C208)
[Service Information] <Date> August 2, 2012
<U101: Setting the voltage for the primary transfer>
[Setting: Base (Standard value)] (Wrong) (Correct)
[Setting: 1st side/2nd side (Correction value of signal-side/duplex printing)] (Wrong) (Correct)
[Setting: B/W (Correction value of monochrome printing)] (Wrong) (Correct)
KYOCERA Document Solutions Europe
Technical Customer Service Division (TCSD)
Loading...