Service Bulletin
SB Number:
Subject:
SB 2KZ-015
The cooling capacity inside the Main body has been improved
Creation Date: 07/03/2012
Model: FS-C8020MFP/8025MFP
Contents of changes
The improve the cooling capacity inside the Main body, the following changes have been made:
The IH cooling fan has been discontinued and the Frame and Toner container cooling duct have been changed,
so that the Toner container cooling fan can cool the Toner container and IH coil.
1 The shape of the Toner container cooling duct has been changed (Part No.1/2).
2 Ventilation slits have been added to the Frame.
3 The Air in-take Fan has been discontinued (Part No. 3).
4 The Duct has been added to the ventilation (Item 2).
5 The Heat-insulating sheet has been discontinued (Part No. 4/5/6/7).
6 The Cooling fan has been changed (Part No. 8).
7 Due to the discontinuation of the Air in-take Fan (Item 3/Part No. 3), the Wire has been changed (Part No. 9).
Parts
No. Old Parts
No.
1 302K002800
2K002800
2 302K002810
2K002810
3 302K094310
2K094310
4 302K002D10
2K002D10
5 302K002E50
2K002E50
6 302K002E60
2K002E60
7 302K002E70
2K002E70
8 302LC94380
2LC94380
9 302K046170
2K046170
New Parts
No.
302MV33020
2MV33020
302MV33030
2MV33030
---------- PARTS FAN MOTOR SP 1 - X -
---------- SPONGE IH COVER 1 - X -
---------- SHEET DUCT IH A 1 - X -
---------- SHEET DUCT IH B 1 - X -
---------- SHEET DUCT IH C 1 - X -
302K994360
2K994360
302MV46540
2MV46540
Description Q’TY Interchange-
ability
Old New Old New
DUCT CONTAINER B 1 1 X X
DUCT CONTAINER C 1 1 X X
PARTS FAN COOLING LSU 60 SP 1 1 X X 3 2 Total
WIRE IH-DLP FAN 1 1 X X
Remarks
Notes: The above menttioned Parts are not listed in the Parts list. The old and latest type of the Parts have been
registered as Service parts.
KMIS Service Department, Kyocera Mita Europe C014 / SB 2KZ-015
Page 1 of 4
Service Bulletin
Classication
Field measure Field modication is not possible since the Frame has to be changed as well. Do not mix the old
Serial numbers of affected machines
Type Serial number
FS-C8020MFP/8025MFP Planned from January 2012 production*.
The above is the plan at the present moment. Please note that there is a possibility of change after giving this
information.
Ventilation has been applied to the Frame
Entire stock rework
type of the parts with the latest type of the parts.
In-eld modication at next visit
The air in-take Fan has been discontinued.
The heat-insulating sheet has been discontinued. (Part No.
5/6/7)
In-eld modication by case
X
No modication necessary
Note: The IH coil has been removed to view
the parts.
Changed Wire
(Part No. 9)
Shape of the Toner container cooling
duct has been changed.
Note: The Inner tray and Inner cover have
been removed to view the parts.
Changed
Cooling fan
(Part No.8)
KMIS Service Department, Kyocera Mita Europe C014 / SB 2KZ-015
Page 2 of 4