Kyocera FS-C5150, FS-C2026, FS-5250, FS-2126MFP ServiceBulletin 2KT-0010-B414 1

(Revised Issue 1) (Page.1/4)
Measures against the SC4600 Error (LSU Cleaning Motor Error)
(-->) and the SC420x Error (Laser Output Error)
Model l:
FS-C5150DN, FS-C5250DN, FS-C2026MFP, FS-C2126MFP, FS-C2026MFP+, FS-C2126MFP+, FS-C2526MFP, FS-C2626MFP
KDC’s Classification Entire Stock Rework In-Field modification at next visit
In-Field modification by case No modification necessary
Field Measure: No particular problem is expected.
Serial Nos. of the Affected Machines: (-->) Please refer to the pages 4 and 5.
LSU unit
Spacer removed
Old
New
Rib added
Lubricant disused
Service Bulletin Ref. No. 2KT-0010 (B414)
<Date> May 27, 2013
This time, the description with (-->) was revised from the previous information.
<Number of changes: 6> The content regarding the permanente measures for the SC420x error was added.
(-->)
Topic
The following changes were implemented as the permanent measures against the service call error SC4600 (LSU cleaning motor error) and SC420x (Laser output error). (For the temporary measures, please refer to the service bulletin SB-2KT-0006-B360.)
(-->) [Permanent measures against the service call error C4600]
The shape of the cleaning holder of the LSU cleaner was changed as the permanent measures. *As the temporary measures, the spacers to prevent the cleaning holder tilt and the lubricant to prevent abnormal sound. Due to the change above, the spacers and lubricant were abolished.
1. Disuse of the spacer and lubricant
2. Shape change of the cleaning holder
Kyocera Document Solutions Europe
Customer Services & Support Division (CSSD)
(Revised Issue 1) (Page.2/4)
No.
Old Part
No.
New Part
No.
Description
Q’
ty
Com
bi
pati­lity
Remarks
Old
New
Old
New
Permanente measures for the service call error C4600
1
302KT93022
2KT93022
302KT93023
2KT93023
LK-591A
1
1
O
O
*1
2
302KT93032
2KT93032
302KT93033
2KT93033
LK-591B
1
1
O
O
*1
3
302KV93022
2KV93022
302KV93023
2KV93023
LK-590A
1
1
O
O
*2
4
302KV93032
2KV93032
302KV93033
2KV93033
LK-590B
1
1
O
O
*2
Permanente measures for the service call error C420x
5
302KT93023
2KT93023
302KT93024
2KT93024
LK-591A
1
1
O
O
*1
6
302KT93033
2KT93033
302KT93034
2KT93034
LK-591B
1
1
O
O
*1
7
302KV93023
2KV93023
302KV93024
2KV93024
LK-590A
1
1
O
O
*2
8
302KV93033
2KV93033
302KV93034
2KV93034
LK-590B
1
1
O
O
*2
BD mirror
BD mirror leaf spring
Sheet abolished
Service Bulletin Ref. No. 2KT-0010 (B414)
<Date> May 27, 2013
(-->) [Permanent measures against the service call error C420x]
The BD sensors (U1 on the PWBs inside of the LSU) were relocated. *The sheet was abolished due to the change above while the sheet had been affixed to the seat of the BD mirror as
the temporary measures in order to prevent the BD mirror shift (informed by the service bulletin SB-2KT-0006­B360).
(Bottom of LSU without the bottom cover)
(-->)
*1 FS-C5150DN *2 FS-C5250DN, FS-C2026MFP, FS-C2126MFP, FS-C2526MFP, FS-C2626MFP, FS-C2026MFP+, FS-C2126MFP+