Service Bulletin
SB Number:
Subject:
SB 2HG-006
Error code SC2102 after switching the main switch ON
Creation Date: 16/02/2010
Model: FS-C5400DN
Phenomenon Error code SC2102 (developer colour motor error) may occur, after switching the main switch
ON.
Cause The inner part of the case DLP may contact the magnet roller, due to resin shrinkage of the case
DLP. This results in increased load to the developer motor.
Solution 1. The thickness of the poly slider washer has been changed from 0.2mm to 0.13mm.
2. Grease has been applied to the shaft of the screw DLP B assy and the oil seal contact
parts.
3. To indicate that the DV-570 has been changed, a black mark has been added to the
barcode label.
The thickness of the poly slider washer has been changed from 0.2mm to 0.13mm.
Grease has been applied to the shaft of the screw DLP B assy and the oil seal contact parts.
To indicate that the DV-570 has been changed, a black mark has been added to the barcode label.
KMIS Service Department, Kyocera Mita Europe 9149 / SB 2HG-006
Page 1 of 2
Parts
Service Bulletin
No. Old Parts
No.
1 302HG93021
2HG93021
2 302HG93031
2HG93031
3 302HG93041
2HG93041
4 302HG93051
2HG93051
Serial numbers of affected units
Type Serial number
DV-570(K) WWR9Y05598
DV-570(Y) WWS9Y05598
DV-570(M) WWT9Y05598
DV-570(C) WWV9Y05598
Units produced after the above mentioned serial numbers, should not have the above mentioned phenomena.
New Parts
No.
302HG93022
2HG93022
302HG93032
2HG93032
302HG93042
2HG93042
302HG93052
2HG93052
Description Q’TY Interchange-
ability
Old New Old New
DV-570(K) 1 1 O O O
DV-570(Y) 1 1 O O O
DV-570(M) 1 1 O O O
DV-570(C) 1 1 O O O
SP
KMIS Service Department, Kyocera Mita Europe 9149 / SB 2HG-006
Page 2 of 2