Service Bulletin
SB Number:
Subject:
SB 2HG-009
Error code SC2102 after switching the main switch ON
Creation Date: 25/08/2010
Model: FS-C5400DN
Phenomenon Error code SC2102 (developer colour motor error) may occur, after switching the main switch
ON.
Cause The inner part of the case DLP may contact the magnet roller, due to resin shrinkage of the case
DLP. This results in increased load to the developer motor.
Solution The inner dimension of the case DLP 302HG14041 has been changed.
Please see service bulletin 2HG-006 for the temporary solution.
The inner dimension of the case DLP 302HG14041 has been changed.
The width has been
reduced with 0.3mm.
Parts
No. Old Parts
No.
1 302HG93022
2HG93022
2 302HG93032
2HG93032
3 302HG93042
2HG93042
4 302HG93052
2HG93052
KMIS Service Department, Kyocera Mita Europe A144 / SB 2HG-009
New Parts
No.
302HG93023
2HG93023
302HG93033
2HG93033
302HG93043
2HG93043
302HG93053
2HG93053
Description Q’TY Interchange-
DV-570(K) 1 1 O O O
DV-570(Y) 1 1 O O O
DV-570(M) 1 1 O O O
DV-570(C) 1 1 O O O
Page 1 of 2
The width has been
reduced with 0.2mm.
SP
ability
Old New Old New
Service Bulletin
Classication
Field measure When the above mentioned phenomenon occurs, please replace the developer unit with the latest
Serial numbers of affected units
Type Serial number
DV-570(K/Y/M/C) June 2010 production.
Units produced after the above mentioned production date, should not have the above mentioned phenomena.
Entire stock rework
type.
In-eld modication at next visit
In-eld modication by case
X
No modication necessary
KMIS Service Department, Kyocera Mita Europe A144 / SB 2HG-009
Page 2 of 2